  • Agilent Technologies 6000 Series - page 1

    Agilent T echnologies Agilent 6000 Series Oscilloscopes Programmer’ s Quick Start Guide ...

  • Agilent Technologies 6000 Series - page 2

    2 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide Notices © Agilent T echnologies, Inc. 2005-2007 N o p a rt o f t h i s m a n u a l m a y be r e p r o d u c e d i n any form or by any means (including elec- tronic storage and retrieval or translation into a foreign language) without prior agree- ment and written consen t from A ...

  • Agilent Technologies 6000 Series - page 3

    Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 3 Programming the Osc illoscope—At a Glance Y ou can automat e 6000 Series oscilloscop e setup and data capture by running programs on a controller PC. Just inst all the A gilent IO Libraries Suite software , connect the osci lloscope (using USB, L AN, or GPIB int erfaces), and be ...

  • Agilent Technologies 6000 Series - page 4

    4 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide In This Book This Progr ammer’s Quick Start Guide is your introduction to programming the oscillo scope using an instr ument controller PC. This book and the Progr ammer’s Refer ence , which is supplied as a Microsoft Windows help file on CD, describes the 6000 Series os cillo ...

  • Agilent Technologies 6000 Series - page 5

    Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 5 Contents 1S e t t i n g U p Step 1. Install Agilent IO Libraries Suite software 8 Step 2. Connect and set up the oscilloscope 8 Using the USB (Device) Interface 9 Using the LAN Interface 9 Using the GPIB Interface 10 Step 3. V erify the oscilloscope connection 11 Step 4. Access th ...

  • Agilent Technologies 6000 Series - page 6

    6 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide Reading Definite-Length Block Query Response Data 26 Sending Multiple Queries and Reading Results 27 Checking Instrument Status 27 Other W ays of Sending Commands 28 Te l n e t S o c k e t s 28 Sending SCPI Commands using Browser Web Control 28 Index ...

  • Agilent Technologies 6000 Series - page 7

    7 Agilent 6000 Series Oscilloscopes Programmer’s Qu ick Start Guide Agilent T echnologies 1 Setting Up Step 1. Install Agil ent IO Libraries Suite software 8 Step 2. Connect and set up the oscilloscope 8 Step 3. V erify the oscilloscope connect ion 11 Step 4. Acc ess the Pr ogrammer’ s Reference 14 This chapter explains how to install t he Agil ...

  • Agilent Technologies 6000 Series - page 8

    8 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 1 Setting Up Step 1. Install Agilent IO Libraries Suite software Inser t th e Aut om at io n-R ea dy CD that was shipped wit h y our oscilloscope into t he controller PC’s CD-ROM driv e, and follo w its inst allation instr uctions. Y ou can also do wnload the A gilent IO Librari ...

  • Agilent Technologies 6000 Series - page 9

    Setting U p 1 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 9 Using the USB (Device) Interface 1 Connect a USB cable from the con troller PC’s USB port t o the “USB DEVICE” port on the back of t he oscilloscope. This is a USB 2.0 high speed por t. 2 On the osci lloscope, verify that t he controller inter face is enabled: ...

  • Agilent Technologies 6000 Series - page 10

    10 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 1 Setting Up Using the GPIB Interface 1 Con nec t a GP IB c able fro m the cont rol ler PC’s GPIB inte r fa ce to th e “G PIB” port on t he back of t he oscilloscope. 2 On the osci lloscope, verify that t he controller inter face is enabled: a Press the Utility butt on. b U ...

  • Agilent Technologies 6000 Series - page 11

    Setting U p 1 Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 11 Step 3. V erify the oscilloscope connection 1 On the controller PC, click on th e Agilent IO Control icon in the t askbar and choose A gilent Connection Expert from the popup menu. 2 In the A gilent Connection Exper t applic ation, instruments connected to t he con ...

  • Agilent Technologies 6000 Series - page 12

    12 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 1 Setting Up Y ou must manually add instru ments on LAN int er faces: a Right-click on the L AN inter face, choose Add In s tr u m en t from t he popup menu, and click OK in the resulti ng dialog (because the desired inter face is already selected). b In the next L AN Instr ument ...

  • Agilent Technologies 6000 Series - page 13

    Setting U p 1 Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 13 b In th e Agil ent Inter acti ve IO a ppli cati on, enter comm ands in th e Command fi eld and press Send Command , Read Response , or Send & Read . c Choose Connect>Exit fr om th e men u to e xit th e Agil ent I nter acti ve IO application. 4 In the A gilen ...

  • Agilent Technologies 6000 Series - page 14

    14 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 1 Setting Up Step 4. Access the Programmer’ s Reference The Pr og ram m er ’s Re fere nc e is supplied on CD as a help f ile readable with the Microsoft Windo ws help view er . The Pr ogrammer’s Ref erence help file describes oscilloscope comm and syntax and st atus reporti ...

  • Agilent Technologies 6000 Series - page 15

    15 Agilent 6000 Series Oscilloscopes Programmer’s Qu ick Start Guide Agilent T echnologies 2 Getting Started Basic Oscilloscope Program Structure 16 Programming the Oscilloscope 18 This chapter gives y ou an ov erview of programming the 6000 Series oscilloscopes. It describes basic oscilloscope program str ucture and sho ws ho w to program t he o ...

  • Agilent Technologies 6000 Series - page 16

    16 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 2 Getting Started Basic Oscilloscope Program Structure The f ollowing figure shows the basic stru cture of ev er y program you will write for the oscilloscope. Initializing T o ensure consistent, repeat able per for mance, you need to star t the prog ram, controller , and oscillo ...

  • Agilent Technologies 6000 Series - page 17

    Getting Started 2 Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 17 Capturing Data Once yo u initialize the oscilloscope, you can be gin capturing data for anal ysis. Remember t hat while the osc illoscope is responding t o commands from the controller , it is not per forming acqu isitions. Also, when you change the oscilloscop ...

  • Agilent Technologies 6000 Series - page 18

    18 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 2 Getting Started Programming the Oscilloscope Referencing the IO Library No matter which instr ument programming libr ar y you use (SICL, VISA, or VISA COM), you mu st refe rence the librar y fr om your pr ogram. In C/C++, y ou must tell the compiler where to find the include an ...

  • Agilent Technologies 6000 Series - page 19

    Getting Started 2 Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 19 Opening the Oscilloscope Conne ction via the IO Library PC controllers communicate with t he oscilloscope by sending and receiving messages o ver a remote inter face. Once you ha ve opened a connection to the oscilloscope ov er t he remote int erface, prog ramm ...

  • Agilent Technologies 6000 Series - page 20

    20 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 2 Getting Started Initializing the Interface and the Oscill oscope T o make sure the bus and all appropriate interfaces are in a known state, begin ev er y program wit h an initialization statement. W hen using the Agilent VISA COM library , you can use the resource session objec ...

  • Agilent Technologies 6000 Series - page 21

    Getting Started 2 Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 21 Using Other Oscillosc ope Setup Commands A typical oscilloscope setup would set the vertical range and of fset voltage, the horizontal ra nge, dela y ti me, delay ref erence, trigge r mode, trigger lev el, and slope. An example of the comm ands that might b e s ...

  • Agilent Technologies 6000 Series - page 22

    22 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 2 Getting Started Capturing Data with the :DIGitize Command The :DIGitize comm and captures dat a that meets t he specif ications set up by the :A CQuire subsystem. When the digitize process is com plete, the acquisition is stopped. The captured dat a can then be measured by the ...

  • Agilent Technologies 6000 Series - page 23

    Getting Started 2 Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 23 The f ollowing pr og ram exampl e shows a typical setup: myScope.WriteString ":ACQUIRE:TYPE AVERAGE" myScope.WriteString ":ACQUIRE:COMPLETE 100" myScope.WriteString ":ACQUIRE:COUNT 8" myScope.WriteString ":DIGITIZE CHANNEL1&qu ...

  • Agilent Technologies 6000 Series - page 24

    24 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 2 Getting Started Reading Query Responses from the Oscilloscope Aft er receiving a que r y (command header follo w ed by a question mark), the in strume nt in terr ogate s the r eque sted func tion and plac es the answ er in i ts output queue. The answ er remains in the output qu ...

  • Agilent Technologies 6000 Series - page 25

    Getting Started 2 Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 25 Reading Query Results in to String V ariab les The output of th e instrument may be nu meric or charact er dat a depending on what is queried. Refer to the spe cific comm and descriptions in the online Progr ammer’s Refer ence for the f or mats and types of d ...

  • Agilent Technologies 6000 Series - page 26

    26 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 2 Getting Started Reading Definite-Length Bl ock Query Response Data Definite-lengt h block query response dat a allo ws any type of device-dependent d a t a t o b e t r a n s m i t t e d ov e r t h e s y s t e m i n t e r f a c e a s a s e r i e s o f 8 - b i t b i n a r y d a t ...

  • Agilent Technologies 6000 Series - page 27

    Getting Started 2 Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 27 Sending Multiple Queries and Reading Results Y ou can send multiple queries to t h e instrument wit hin a single command string, but you must also read them back as a single quer y result. This can be accomplished b y reading t hem back into a sing le string va ...

  • Agilent Technologies 6000 Series - page 28

    28 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide 2 Getting Started Other W ays of Sending Commands Standard Commands for Programmable Instrument ation (SCPI) can be sent via a T elnet socket or through the Bro wser W eb Control. Te l n e t S o c k e t s The f ollowing information is pro vided f or those programmers who wish to ...

  • Agilent Technologies 6000 Series - page 29

    Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 29 Index Numerics 82350A GPIB inte rface , 4 A ACQuire subsystem , 22 Addresses softkey , 9 Agilent Connecti on Expert , 11 Agilent In teractive IO applic ation , 13 Agilent IO Control ico n , 11 Agilent IO Librarie s Suite , 3 , 4 , 7 , 18 , 20 installing , 8 analyzing captur ed d ...

  • Agilent Technologies 6000 Series - page 30

    30 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide Index ReadString method , 19 , 24 resource session object , 20 ResourceManager object , 19 S sample programs , 14 SCPI commands , 28 set up oscilloscope , 8 SICL library , 3 status registers , 27 status reporting data structures , 14 string variables , 25 reading multiple query r ...

  • Agilent Technologies 6000 Series - page 31

    Agilent 6000 Series Oscilloscopes Programmer’s Quick S tart Guide 31 Index ...

  • Agilent Technologies 6000 Series - page 32

    32 Agilent 6000 Series Oscilloscopes Programmer’s Quick Start Guide Index . ...

Manufacturer Agilent Technologies Category Sprinkler

Documents that we receive from a manufacturer of a Agilent Technologies 6000 Series can be divided into several groups. They are, among others:
- Agilent Technologies technical drawings
- 6000 Series manuals
- Agilent Technologies product data sheets
- information booklets
- or energy labels Agilent Technologies 6000 Series
All of them are important, but the most important information from the point of view of use of the device are in the user manual Agilent Technologies 6000 Series.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Agilent Technologies 6000 Series, service manual, brief instructions and user manuals Agilent Technologies 6000 Series. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Agilent Technologies 6000 Series.

A complete manual for the device Agilent Technologies 6000 Series, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Agilent Technologies 6000 Series by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Agilent Technologies 6000 Series.

A complete Agilent Technologies manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Agilent Technologies 6000 Series - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Agilent Technologies 6000 Series, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Agilent Technologies 6000 Series, that we can find in the current document
3. Tips how to use the basic functions of the device Agilent Technologies 6000 Series - which should help us in our first steps of using Agilent Technologies 6000 Series
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Agilent Technologies 6000 Series
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Agilent Technologies 6000 Series in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Agilent Technologies 6000 Series?

Use the form below

If you did not solve your problem by using a manual Agilent Technologies 6000 Series, ask a question using the form below. If a user had a similar problem with Agilent Technologies 6000 Series it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)