  • Lincoln Electric 500 - page 1

    VA N T A G E 5 0 0 OPERA TOR’S MANUAL IM957 April, 2009 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS M ...

  • Lincoln Electric 500 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric 500 - page 3

    ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Us e suitable clothing made from durable flame-resistant material to protect your skin and that of ...

  • Lincoln Electric 500 - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric 500 - page 5

    iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les ...

  • Lincoln Electric 500 - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric 500 - page 7

    vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications ....................................................................................................... A-1 Machine Specification ...................... ...

  • Lincoln Electric 500 - page 8

    vii vii T ABLE OF CONTENTS Maintenance ......................................................................................................Section D Safety Precautions ................................................................................................D-1 Routine Maintenance ............................................................ ...

  • Lincoln Electric 500 - page 9

    VANTAGE ® 500 (1) Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced. (2) Reduced to less than 30V in the CC-stick Mode when VRD (VOLTAGE REDUCTION DEVICE) is on. (3) Maximum per circuit breaker rating ...

  • Lincoln Electric 500 - page 10

    A-2 INST ALLA TION VANTAGE ® 500 A-2 RECEPTACLES AUXILIARY POWER CIRCUIT Breaker OTHER CIRCUIT BREAKERS MACHINE SPECIFICA TIONS (2)120VAC Duplex (5-20R) GFCI Protected (1) 120/240 VAC Dual Voltage Full KVA (14-50R) (1) 240VAC 3-Phase (15-50R) Two 20AMP for Two Duplex Receptacle (1) 50AMP for Dual Voltage and for 3-Phase (3-pole) 10AMP for Battery ...

  • Lincoln Electric 500 - page 11

    A-3 INST ALLA TION VANTAGE ® 500 A-3 SAFETY PRECAUTIONS Only qualified personnel should install, use, or service this equipment. Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintena ...

  • Lincoln Electric 500 - page 12

    A-4 INST ALLA TION VANTAGE ® 500 A-4 HIGH ALTITUDE OPERATION At higher altitudes, output derating may be necessary. For maximum rating, derate the machine 1.0% for every 2000 ft. (610m) up to 6000 ft. (1828m) and 2.0% for every 2000 ft. (610m) over 6000 ft. (1828m). Due to new EPA and other local emissions regulations, modifications to the engine ...

  • Lincoln Electric 500 - page 13

    The standard muffler included with this welder does not qualify as a spark arrester. When required by local regulations, a suitable spark arrester, such as the K903-1 must be installed and properly maintained. An incorrect spark arrestor may lead to damage to the engine or adversely affect performance. ---------------------------------------------- ...

  • Lincoln Electric 500 - page 14

    A-6 INST ALLA TION VANTAGE ® 500 A-6 ELECTRICAL CONNECTIONS MACHINE GROUNDING Because this portable engine driven welder creates its own power, it is not necessary to connect its frame to an earth ground, unless the machine is connected to premises wiring (home, shop, etc.) To prevent dangerous electric shock, other equipment to which this engine ...

  • Lincoln Electric 500 - page 15

    ST ANDBY POWER CONNECTIONS The VANTAGE® 500 is suitable for temporary, stand- by or emergency power using the engine manufactur- er’s recommended maintenance schedule. The VANTAGE® 500 can be permanently installed as a standby power unit for 240 VAC, 3 wire, single phase, 50 amp service. Connections must be made by a licensed electrician who ca ...

  • Lincoln Electric 500 - page 16

    A-8 INST ALLA TION VANTAGE ® 500 A-8 CONNECTION OF V ANT AGE 500 TO PREMISES WIRING W ARNING • Only a licensed, certified, trained electrician should install the machine to a premises or residential electrical system. Be certain that: • The installation complies with the National Electrical Code and all other applicable electrical codes. • T ...

  • Lincoln Electric 500 - page 17

    A-9 INST ALLA TION VANTAGE ® 500 A-9 CONNECTION OF LINCOLN ELECTRIC WIRE FEEDERS Connection of LN-7 or LN-8 to the VANTAGE® 500 1. Shut the welder off. 2. Connect the LN-7 or LN-8 per instructions on the appropriate connection diagram in Section F. 3. Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as req ...

  • Lincoln Electric 500 - page 18

    A-10 INST ALLA TION VANTAGE ® 500 A-10 Spool Gun (K487-25) and Cobramatic to VAN- TAGE® 500 • Shut the welder off. • Connect per instructions on the appropriate connec- tion diagram in Section F. Connection of the LN-25 to the VANTAGE® 500 Shut off welder before making any electrical con- nections. ------------------------------------------- ...

  • Lincoln Electric 500 - page 19

    B-1 OPERA TION VANTAGE ® 500 B-1 SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists. ------------------------------------------ ...

  • Lincoln Electric 500 - page 20

    B-2 OPERA TION B-2 WELDING CONTROLS (Figure B.1) 1 . OUTPUT CONTROL- The OUTPUT dial is used to preset the output voltage or current as dis- played on the digital meters for the five welding modes. When in the CC-STICK, ARC GOUGING or CV-WIRE modes and when a remote control is con- nected to the 6-Pin or 14-Pin Connector, the auto- sensing circuit ...

  • Lincoln Electric 500 - page 21

    B-3 OPERA TION B-3 4. ARC CONTROL - The ARC CONTROL dial is active in the CV-WIRE, CC-STICK and DOWNHILL PIPE modes, and has different functions in these modes. This control is not active in the TIG and ARC GOUGING mode. CC-STICK mode: In this mode, the ARC CONTROL dial sets the short circuit current (arc-force) during stick welding to adjust for a ...

  • Lincoln Electric 500 - page 22

    TYPICAL V ANT AGE® 500 FUEL CONSUMPTION TABLE B.2 PERKINS 404D-22T Gal./Hr (Liters/Hr) .38(1.44) .59(2.23) 2.15(8.14) 1.91(7.23) 1.30 (4.92) Running Time for 20 gallons / hours 52.63 33.90 9.30 10.47 15.38 Low Idle - No Load 1400 R.P.M. High Idle - No Load 1850 R.P.M. DC Weld Output 500 Amps @ 40Volts 20,000 Watts 3 Phase 12,000 Watts 1 Phase NOTE ...

  • Lincoln Electric 500 - page 23

    WELDER OPERA TION DUTY CYCLE Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For example a 60% duty cycle, represents 6 minutes of load and 4 minutes of no load in a 10 minute period. ELECTRODE INFORMATION For any electrode the procedures should be kept with- in the rating of the machine. For information on ele ...

  • Lincoln Electric 500 - page 24

    When in the TOUCH START TIG mode and when a Amptrol is connected to the 6-Pin connector the OUT- PUT CONTROL dial is used to set the maximum cur- rent range of the current control of the Amptrol. The ARC CONTROL is not active in the TIG mode. To STOP a weld, simply pull the TIG torch away from the work. When the arc voltage reaches approximately 30 ...

  • Lincoln Electric 500 - page 25

    Carbon Diameter Current Range (DC, electrode positive) 1/8"(3.2mm) 60-90 Amps 5/32"(4.0mm) 90-150 Amps 3/16"9(4.8mm) 200-250 Amps 1/4"(6.4mm) 300-400 Amps 3/8"(10.0mm) 400-Max.Amps AUXILIAR Y POWER: Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the wel ...

  • Lincoln Electric 500 - page 26

    C-1 ACCESSORIES C-1 VANTAGE ® 500 FIELD INST ALLED OPTIONS / ACCESSORIES are available at www .lincolnelectric.com. Follow these steps: 1. Go to www.lincolnelectric.com 2. At the top of the screen in the Search field type E6.214 click on Search Icon. 3 . On the results screen click on Engine Driven Welders: Vantage 500 4. On this results screen wh ...

  • Lincoln Electric 500 - page 27

    D-1 MAINTENANCE D-1 VANTAGE ® 500 SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • Turn the engine off before working inside the machine or servicing the engine. • Remove guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is complete. If ...

  • Lincoln Electric 500 - page 28

    D-2 MAINTENANCE D-2 ENGINE OIL CHANGE Drain the engine oil while the engine is warm to assure rapid and complete draining. It is recommended that each time the oil is changed the oil filter be changed as well. • Be sure the unit is off. Disconnect the negative bat- tery cable to ensure safety. • Locate oil drain hose and valve in bottom of base ...

  • Lincoln Electric 500 - page 29

    D-3 MAINTENANCE D-3 VANTAGE ® 500 Unfasten or unlatch the service cover . Because the filter fits tightly over the outlet tube to create the critical seal, there will be some initial resistance, similar to breaking the seal on a jar . Gently move the end of the filter back and forth to break the seal then rotate while pulling straight out. Avoid k ...

  • Lincoln Electric 500 - page 30

    D-4 MAINTENANCE D-4 COOLING SYSTEM HOT COOLANT can burn skin. • Do not remove cap if radiator is hot. ------------------------------------------------------------------------ Check the coolant level by observing the level in the radiator and recovery bottle. Add 50/50 antifreeze / water solution if the level is close to or below the "LOW&quo ...

  • Lincoln Electric 500 - page 31

    D-5 MAINTENANCE D-5 FUEL FIL TER 1 . Check the fuel filter and fuel pre-filter for water accumulation or sediment. 2. Replace the fuel filter if it is found with excessive water accumulation or sediment. Empty fuel pre-fil- ter. ENGINE ADJUSTMENT Adjustments to the engine are to be made only by a Lincoln Service Center or an authorized Field Servic ...

  • Lincoln Electric 500 - page 32

    D-6 MAINTENANCE D-6 VANTAGE ® 500 GFCI MODULE TESTING AND RESETTING PROCEDURE The GFCI module should be properly tested at least once every month or whenever it is tripped. To properly test and reset the GFCI module: • If the module has tripped, first carefully remove any load and check it for damage. • If the equipment has been shut down, it ...

  • Lincoln Electric 500 - page 33

    E-1 TROUBLESHOOTING E-1 VANTAGE ® 500 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair p ...

  • Lincoln Electric 500 - page 34

    E-2 TROUBLESHOOTING E-2 VANTAGE ® 500 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ...

  • Lincoln Electric 500 - page 35

    E-3 TROUBLESHOOTING E-3 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SYMPTOMS) POS ...

  • Lincoln Electric 500 - page 36

    E-4 TROUBLESHOOTING E-4 VANTAGE ® 500 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ...

  • Lincoln Electric 500 - page 37

    E-5 TROUBLESHOOTING E-5 VANTAGE ® 500 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ...

  • Lincoln Electric 500 - page 38

    E-6 TROUBLESHOOTING E-6 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS (SYMPTOMS) POS ...

  • Lincoln Electric 500 - page 39

    F-1 DIAGRAMS F-1 VANTAGE ® 500 ...

  • Lincoln Electric 500 - page 40

    F-2 DIAGRAMS F-2 VANTAGE ® 500 ...

  • Lincoln Electric 500 - page 41

    F-3 DIAGRAMS F-3 VANTAGE ® 500 ...

  • Lincoln Electric 500 - page 42

    F-4 DIAGRAMS F-4 VANTAGE ® 500 ...

  • Lincoln Electric 500 - page 43

    F-5 DIAGRAMS F-5 VANTAGE® 500 ...

  • Lincoln Electric 500 - page 44

    F-6 DIAGRAMS F-6 VANTAGE® 500 ...

  • Lincoln Electric 500 - page 45

    F-7 DIAGRAMS F-7 VANTAGE® 500 ...

  • Lincoln Electric 500 - page 46

    F-8 DIAGRAMS F-8 VANTAGE® 500 2 9/03 ...

  • Lincoln Electric 500 - page 47

    F-9 DIAGRAMS F-9 VANTAGE® 500 ...

  • Lincoln Electric 500 - page 48

    F-10 WIRING DIAGRAM F-10 VANTAGE ® 500 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is included with the machine. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number. ...

  • Lincoln Electric 500 - page 49

    F-11 DIMENSION PRINT F-11 VANTAGE ® 500 L13699 B 25.82 655.8 27.00 685.8 55.50 1409.7 2.25 57.2 5.75 146.0 35.94 913.0 24.00 609.6 39.41 1001 20.60 523.3 28.95 735.3 36.06 915.9 60.00 1524.0 N.A. NOTES: N.A. CENTER OF GRAVITY W ITH OIL IN ENGINE, COO L ANT IN RA DIATOR, AND EMPTY FUEL TANK. 1.27 32.3 46.62 1184.15 16.75 425.4 30.69 779.5 ...

  • Lincoln Electric 500 - page 50

    NOTES VANTAGE ® 500 ...

  • Lincoln Electric 500 - page 51

    NOTES VANTAGE® 500 ...

  • Lincoln Electric 500 - page 52

    WA R N I N G A VISO DE PRECAUCION A TTENTION WA R N U N G A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ...

  • Lincoln Electric 500 - page 53

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish F rench German P ortuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric 500 - page 54

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Manufacturer Lincoln Electric Category Welder

Documents that we receive from a manufacturer of a Lincoln Electric 500 can be divided into several groups. They are, among others:
- Lincoln Electric technical drawings
- 500 manuals
- Lincoln Electric product data sheets
- information booklets
- or energy labels Lincoln Electric 500
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lincoln Electric 500.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lincoln Electric 500, service manual, brief instructions and user manuals Lincoln Electric 500. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lincoln Electric 500.

A complete manual for the device Lincoln Electric 500, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lincoln Electric 500 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lincoln Electric 500.

A complete Lincoln Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lincoln Electric 500 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lincoln Electric 500, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lincoln Electric 500, that we can find in the current document
3. Tips how to use the basic functions of the device Lincoln Electric 500 - which should help us in our first steps of using Lincoln Electric 500
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lincoln Electric 500
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lincoln Electric 500 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lincoln Electric 500?

Use the form below

If you did not solve your problem by using a manual Lincoln Electric 500, ask a question using the form below. If a user had a similar problem with Lincoln Electric 500 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)