    Model ST-2400S Horsepower Computer System User Manual In the USA: Star Test Dynamometer, Inc. 712 Thistlewood Court Normal, IL 61761 Phone: (309) 826-1484 In Mexico, Central & South America: Negociaciones Fuentes S.A. DE CV Av. La Luz 4549 Col. Cortijo del Rio Monterey, N.L. Mexico 64890 Phone: 81.8349.1416 Manufacturered by: Ries Labs, Inc. 22 ...

  • Ries Labs Horsepower Computer System ST-2400S - page 2

    Table of Contents Description ------------- --------------------------------------- ------------ 3 Installation ---------- ------------------------------------------- ----------- 3 Power Supply ---------- --------------------------------------- -------- 4 Operation of the unit from 220-260 VAC 50-60 Hz ----------- 4 Operation -------------- ------- ...

  • Ries Labs Horsepower Computer System ST-2400S - page 3

    Description: The function of the Model 2400S Horsepower Co mputer is to provide the operator w ith a continuous digital readout of the RPM, TO RQUE, POWER (Horsepower or Kilowatts) and percentage of Torque Rise ( % TORQUE RISE) when properly attached to a compatible dynamometer. The RPM readout shows the operator the rota tion speed (rotations per ...

  • Ries Labs Horsepower Computer System ST-2400S - page 4

    Power Supply: The Model 2400S horsepower computer is normally operated from 110 to 125 VAC (60 Hz) using the outlet mounted pow er supply that is supplied with the unit. The power consumption of the comput er is very low and the unit has a very high tolerance for power supply variati ons, so nearly any standard 115 VAC utility power outlet should p ...

  • Ries Labs Horsepower Computer System ST-2400S - page 5

    values are computed and displayed. This process is repeated continuously while the unit is in operation. Computer Function Switch: The computer function switch is used to turn the system power ON/OFF and to control the functional operati on of the horsepower computer. The function switch has four positions ( “OFF”, “ZERO”, “CHECK”, and ...

  • Ries Labs Horsepower Computer System ST-2400S - page 6

    10,000 3750 2856 CHECK readings using Ft .-Lbs. & Horsepower 6 ...

  • Ries Labs Horsepower Computer System ST-2400S - page 7

    Load Cell Rating (Ft.-Lbs.) Torque (N-M) Power (KW) 100 (135.5 N-M) 50.84 21.30 200 (271 N-M) 101.6 42.60 500 (677.5 N-M) 254.2 106.5 1,000 (1355 N-M) 508.4 213.0 2,000 (2710 N-M) 1016 426.0 5,000 (6775 N-M) 2542 1065 10,000 (13550 N-M) 5084 2130 CHECK readings using Newt on-Meters and Kilowatts The ZERO and CHECK positions of the computer function ...

  • Ries Labs Horsepower Computer System ST-2400S - page 8

    The torque set switch is used to set the torque reference which is used to compute the % Torque Rise reading. To set the torque reference, proceed as follows: Run the engine at it rated speed, load ed at rated power or torque output. This represents the 100% torque output cond ition for the engine. With the engine running at its rated speed and loa ...

  • Ries Labs Horsepower Computer System ST-2400S - page 9

    When the horsepower computer is used with a companion personal computer, a standard (9 pin) RS-232-C extension cable is used to connect the two computers together. This exte nsion cable is normally 10 feet long, but can be up to 50 feet long (and ev en longer if special “long range” RS- 232-C extension cables are used). The print rate and manua ...

  • Ries Labs Horsepower Computer System ST-2400S - page 10

    recording can be controlled fr om the 2400S horsepower computer and / or using the personal computer’s keyboard or mouse. Recorded data can be printed on th e PC’s printer and / or can be easily “imported” into Micros oft Excel (or other analysis programs) for further operations such as graphing, etc. Dyno32 is compatible with m ost Windows ...

  • Ries Labs Horsepower Computer System ST-2400S - page 11

    2.) The instrument has been moved (re -installed) from one dynamom eter to another. 3.) The load cell of the dynamometer has been replaced, overloaded, dropped or otherwise mistreated. 4.) The power supply to the unit has been repaired or replaced. 5.) Prior to any measurements that requ ire especially high accuracy. 6.) The instrument has been rep ...

  • Ries Labs Horsepower Computer System ST-2400S - page 12

    the torque arm of the dynamometer to insure that there is no force being applied to the load cell (which would result in an inaccurate zero calibration). Remove the calib ra tion access cover panel and s et the calibration mode switch to the ZERO position. Also, be sure that the shunt resistor switch is set to th e OFF position. At this time note t ...

  • Ries Labs Horsepower Computer System ST-2400S - page 13

    positive and negative torque to the u n it) and ver ify that the torque reading returns closely to the same value. A failure he re indicates a likely problem with the dynamometer. Have the dynamometer checked by your dealer or dyno service person. 1.3 Make sure that the load has been comp letely removed from the load cell. Disconnect the load cell ...

  • Ries Labs Horsepower Computer System ST-2400S - page 14

    dynamometer. The calibration torque produ ced is equal to the sum of the torque produced by the Torque Test Bar itself plus the torque produced by the test weight(s) – which is equal to the tota l weight of the test weight(s) times the horizontal distance from the center line of the dyno to the position of the test weights. For example, assume th ...

  • Ries Labs Horsepower Computer System ST-2400S - page 15

    In Case of Difficulty: The following is a troubleshooting guide that will help you to resolve any problems that may arise. The Model 2400S Horsepower Computer contains no user serviceable parts. If it needs to be repaired you may return the unit to your dealer (who can also assist you with other repair problems such as problem diagnosis , replacem ...

  • Ries Labs Horsepower Computer System ST-2400S - page 16

    The following table is useful for you to de termine that cause of any problems that you might be able to fix yourself. Problem Possible causes and remedies No indication on displays. Power LED is not lit. There is likely no power to th e unit. Check the power supply to be sure it is plugged in. Ch eck the fuse on the front panel of the unit. Replac ...

  • Ries Labs Horsepower Computer System ST-2400S - page 17

    and the RPM sensor gear. Make sure that they are not loose and that the runout of the RPM gear is not excessive. Check the RPM sensor connector to be sure that it is tight. Check the cable from the RPM pickup to the horsepower computer. Check the power supply to the horsepower computer. Have the horsepower computer checked. Torque readings are inac ...

Manufacturer Ries Labs Category Power Supply

Documents that we receive from a manufacturer of a Ries Labs Horsepower Computer System ST-2400S can be divided into several groups. They are, among others:
- Ries Labs technical drawings
- Horsepower Computer System ST-2400S manuals
- Ries Labs product data sheets
- information booklets
- or energy labels Ries Labs Horsepower Computer System ST-2400S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Ries Labs Horsepower Computer System ST-2400S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Ries Labs Horsepower Computer System ST-2400S, service manual, brief instructions and user manuals Ries Labs Horsepower Computer System ST-2400S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Ries Labs Horsepower Computer System ST-2400S.

A complete manual for the device Ries Labs Horsepower Computer System ST-2400S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Ries Labs Horsepower Computer System ST-2400S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Ries Labs Horsepower Computer System ST-2400S.

A complete Ries Labs manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Ries Labs Horsepower Computer System ST-2400S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Ries Labs Horsepower Computer System ST-2400S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Ries Labs Horsepower Computer System ST-2400S, that we can find in the current document
3. Tips how to use the basic functions of the device Ries Labs Horsepower Computer System ST-2400S - which should help us in our first steps of using Ries Labs Horsepower Computer System ST-2400S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Ries Labs Horsepower Computer System ST-2400S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Ries Labs Horsepower Computer System ST-2400S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Ries Labs Horsepower Computer System ST-2400S?

Use the form below

If you did not solve your problem by using a manual Ries Labs Horsepower Computer System ST-2400S, ask a question using the form below. If a user had a similar problem with Ries Labs Horsepower Computer System ST-2400S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)