Manual IMC Networks iMcV-LIM

20 pages 0.55 mb
Download

Go to site of 20

Summary
  • IMC Networks iMcV-LIM - page 1

    iMcV-LIM Operation Manual ...

  • IMC Networks iMcV-LIM - page 2

    ii FCC Radio Frequency Inter ference Statem ent This equipment has been tested and found t o comply with the limits for a Class B computing device, pur suant to Part 15 of the F CC Rul es. These limits are designed to pr ovide reasonable protection against harmful interference when the equipment is operat ed in a com mercia l environment. This equi ...

  • IMC Networks iMcV-LIM - page 3

    iii Table of Cont ents FCC Radio Fre quency Inter ference Stateme nt .................................................... ii Warranty ............ ................................................................. ............................... ii About the iMcV-LIM ............................................................ ...................... ...

  • IMC Networks iMcV-LIM - page 4

    1 Abo ut the i McV- LIM Th e iMcV- LIM is a Fa st Eth ern et modu le wh ich pro vid es a s ingle c onve rsio n bet ween 100Base-TX twi sted pair an d 100Ba se-FX/SX si ngle-mode or multi -mode fiber. Each iMcV- LIM includes one RJ -45 conn ector and o ne pair of ST or SC fiber optic connecto rs, and/or a n SFP port, which can support any fiber type ...

  • IMC Networks iMcV-LIM - page 5

    2 Managed Modules To manage one or m ore iMcV-LIM(s), an S N MP agent must be present in the chassis. To c onfi gure M ana ged M odu le s, in st all the m o dule fir st, a nd the n c onf igu re u sin g the management software . Fib er type, ser ial number and dat e code are now load ed into the NVR AM during manufacturing. This is viewed only via i ...

  • IMC Networks iMcV-LIM - page 6

    3 - If another ty pe of m odule is in stalled in to the same slot in a ch assis, t he iMcV-LIM clears the mem ory of the prev ious config uration for th at slot; th e settings of a new module are a dopted and st ored in the iMcV-LIM Th e SNMP Write L ock switch does no t impact any iMcV-Module o r iMcV-Mod ule with Configurat ion Co ntrol . Removin ...

  • IMC Networks iMcV-LIM - page 7

    4 iMcV-LIM DIP Switch on S1 Feature Default Se tting 1 Auto Negotiation (AN) ON 2 Far E nd Fault (FEF) OFF 3 FX LinkLoss (FXLL) OFF 4 TX LinkLoss (TXLL) OFF 5 FiberAlert (FA) OFF 6 Factor y Def ault OFF 7 Factor y Def ault OFF 8 Factor y Def ault OFF BEST PRACTICES When possible, it i s always a good idea to configure DIP Switches to match software ...

  • IMC Networks iMcV-LIM - page 8

    5 iMcV-LIM wit h SFP a nd C onfiguration Control DIP Switch on S1 Feature Default Se tting 1 Auto Negotiation (AN) ON 2 Far E nd Fault (FEF) OFF 3 FX LinkLoss (FXLL) OFF 4 TX LinkLoss (TXLL) OFF 5 FiberAlert (FA) OFF 6 Factor y Def ault OFF 7 Enable TX port ON 8 Enable FX port ON ...

  • IMC Networks iMcV-LIM - page 9

    6 FX Lin kLoss, TX LinkLoss, Li nk Fault Pas s-Through, Far End Fa ult and Fibe rA lert iMcV-LIM modules include the tro ubleshooting features FiberAlert, TXLL, FXLL, FEF and LFPT that help locate silent failure s on a network. Before attem pting to install the module(s), understan d how these fe atures work and re act to a specific network configu ...

  • IMC Networks iMcV-LIM - page 10

    7 Link F ault P ass-T hrou gh ( LFPT ) Link Fault Pass-Through (LFPT) is a trou bleshooting feature that combines TX and FX LinkLoss from bot h the local an d remote i McV-LIM mo dules. LFPT is enable d by turning on b oth FX and T X LinkLoss on both m odules. This feature all ows either end of the conversion to de tect a link fault occurring at th ...

  • IMC Networks iMcV-LIM - page 11

    8 FiberAlert and Far End Fault Modules s hip fr om the f actory wit h troubl eshootin g features disable d. Refer to the help file to e nable/di sable this f eature. Fibe rA lert (F A) Fib erAlert minimizes th e problems asso ciated wi th th e loss of one strand of fiber. If a strand is una vailable, the IMC Networks de vice at the receiver end not ...

  • IMC Networks iMcV-LIM - page 12

    9 FEF versus FA FEF is preferred when the devices at both ends of the fiber can interpret the FEF signal. This all ows FEF t o be turned on at both ends, whic h will engage t he FEF regardless of which directi on the fault occurs. (Please refer to dia gram on previous pag e) For exa mple if a f ault shou ld occur on segment 2 in the dir ection of s ...

  • IMC Networks iMcV-LIM - page 13

    10 Auto Nego tiation on i McV-LIM iMcV-L IM modules i nclude the f eatur e Auto Negoti ation. When Au to Negotiat ion is enabled, the mo dule negotiates as a 100 Mb ps full-duplex device. If the conne cted device can operate at 100 Mb ps full-duplex, a link is established. A uto Negotiation (DIP Switch #1) is enabled by default. If th e twist ed pa ...

  • IMC Networks iMcV-LIM - page 14

    11 LED Operation Each iMcV-LIM module features diagn ostic LEDs that provide information on features and ports. FEF Glows green w hen a fiber en d fault is dete ct ed . TXLL Glows green when TX LinkLoss i s enabled on the port. Blinks when a fault occurs on the copper port and ac tively di sables the fiber port. LNK Glows green when fiber link is e ...

  • IMC Networks iMcV-LIM - page 15

    12 Installat ion Tro ubles hoot ing • During installation, first test the fiber and twiste d pair connecti ons with all troubleshooting features disable d, then enable these features, if desire d, just before final in stallati on. This will reduce the fe atures’ interference wi th testing. • Whe n working wi th unit s where t he feat ur es ca ...

  • IMC Networks iMcV-LIM - page 16

    13 Spec if icat io ns Environmental Operatin g Temp eratur e +32°F to +122°F (0°C to +50°C) Storage T empe rat ure -13°F to +158 °F (-25°C to +7 0°C) Humidity: 5 - 95% (non-condensing) DC Inp ut iMcV- LIM w/L FPT: 0. 80 Amp @ 5V Fiber Optic Specifications For fiber optic specifications, please visi t: htt p:/ /w ww. im c ne tw orks .c om /a ...

  • IMC Networks iMcV-LIM - page 17

    14 Fiber Op tic Cleaning Guidelines Fiber Optic tran smitters an d receivers are e xtremely susce ptible to c ontamination by particles of d irt or dust, which can obst ruct the optic path and cause performance degradation. Good system performan ce requires clean optics and c onnector ferrules. 1. Use fiber patch cord s (or connectors, if you ter m ...

  • IMC Networks iMcV-LIM - page 18

    15 El ectro stati c Dis charg e Preca utions Electrostatic discharge (ESD) can cause dama ge to any product, add- in module s or stand alone units, containing ele ctronic componen ts. Always observe the following precauti ons when installing or han dling these kinds of products 1. Do not remove unit from its protecti ve pa ckagin g until ready t o ...

  • IMC Networks iMcV-LIM - page 19

    16 Certi fic at ions CE: The products described herein co mply with the Council Directive on Electromagne tic Compat ibility (2004/ 108/EC). European Directive 2002/96/EC (WEEE) requir es that any equipment that bears this symbol on product or pa ckagin g must n ot be d ispose d of wi th unsor ted munic ipal waste. This symbol in dicates that the e ...

  • IMC Networks iMcV-LIM - page 20

    19772 Pauling • Foothill Ranc h, CA 92610-26 11 USA TEL: (94 9) 465 -3000 • FAX: (9 49) 465 -3020 www.imcnetworks.com © 2010 I MC Networks. Al l rights r eserved. The info rmation in this docum ent is subject to change with out no tice. IMC Networks assumes no responsibi lity for any errors that may appear in this docume nt. iMcV-LIM is a trad ...

Manufacturer IMC Networks Category Network Card

Documents that we receive from a manufacturer of a IMC Networks iMcV-LIM can be divided into several groups. They are, among others:
- IMC Networks technical drawings
- iMcV-LIM manuals
- IMC Networks product data sheets
- information booklets
- or energy labels IMC Networks iMcV-LIM
All of them are important, but the most important information from the point of view of use of the device are in the user manual IMC Networks iMcV-LIM.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals IMC Networks iMcV-LIM, service manual, brief instructions and user manuals IMC Networks iMcV-LIM. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product IMC Networks iMcV-LIM.

A complete manual for the device IMC Networks iMcV-LIM, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use IMC Networks iMcV-LIM by users. Manuals are usually written by a technical writer, but in a language understandable to all users of IMC Networks iMcV-LIM.

A complete IMC Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual IMC Networks iMcV-LIM - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the IMC Networks iMcV-LIM, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the IMC Networks iMcV-LIM, that we can find in the current document
3. Tips how to use the basic functions of the device IMC Networks iMcV-LIM - which should help us in our first steps of using IMC Networks iMcV-LIM
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with IMC Networks iMcV-LIM
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of IMC Networks iMcV-LIM in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning IMC Networks iMcV-LIM?

Use the form below

If you did not solve your problem by using a manual IMC Networks iMcV-LIM, ask a question using the form below. If a user had a similar problem with IMC Networks iMcV-LIM it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)