Manual SMC Networks SMC TigerStack III SMC6826MPE

94 pages 1.9 mb
Download

Go to site of 94

Summary
  • SMC Networks SMC TigerStack III SMC6826MPE - page 1

    T igerStack III 10/100 24- Po r t Fa s t E t h e rn e t S w i tch ◆ 24 au to-MDI/MDI-X 1 0B ASE-T/100B ASE-TX ports ◆ 10B AS E-T/10 0B AS E-TX ports sup port PoE ca pabilit ies ◆ 2 Gigabi t combo ports ( RJ-45/ SFP) ◆ 8.8 Gbp s of aggreg ate ba ndwidth ◆ Stacks up t o 8 units ◆ Non-blo cking switching archi tecture ◆ Spanning T ree Pr ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 2

    ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 3

    38 T esla Irvi ne, CA 92618 Phone: (949) 679-80 00 T igerStack III 10/100 Installation Guide From SMC’ s T iger line of feature-rich w o rkgro up LAN solutions Jun e 2005 Pub. # 15020 0037700A ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 4

    Infor mation fur nished by SMC Networks , In c . (SMC) is believed to be accurate and reliable . H o w eve r , no responsibility is assumed by SMC for its use, no r for any infrin geme nts of p atents or othe r righ ts of third par ties which may result from its use. No license is g rante d by implicatio n or othe rwise u nder an y pate nt or pat e ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 5

    i L IMITED W ARRANTY Limited W ar ranty Statement: SMC Ne tworks , Inc. (“S MC”) war r ants its p roduc ts to be fre e from defects i n wor kmanship and materials , under nor mal use and ser vice , for the applicable warranty ter m. All SMC products carr y a standard 90-da y limited warranty from the date of purchase from SMC or its A uthorize ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 6

    L IM IT ED W AR RANTY ii WARRA NTI ES E X C LUSIV E: IF AN SMC PR ODUCT DOES NOT OPERA TE AS W ARRANTED ABO VE, CUSTOMER’ S SOLE REM ED Y SHALL BE R EP AIR OR REPLA CEMENT OF THE PR OD UCT I N QUES TION , A T SMC’S OPTION . THE FOREG OING W ARRANTIES AND R EMEDI ES AR E EX C L USIV E AND A RE I N LI EU OF ALL OTHER W ARRANTIES OR CONDITION S , ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 7

    i C OMPLIANCES FCC - C lass A This equi pment generate s , us es , and can rad iate rad io fre quency en erg y and, if not inst alled and used i n accor dance with t he instr ucti on man ual, may cause int erferenc e to ra dio comm u- nications . It has been te ste d and found t o co mply with t he limits fo r a Class A compu ting device pursuant t ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 8

    C OMPLIANCES ii CE Mark Declaratio n of Confor mance for EMI and Safety (EEC ) This inform ation te chnolo g y equipment compli es with th e requirements of the Council Directi ve 8 9/336/EEC on the Appro x imation of the la w s of t he Member St ates relating to Elect romagneti c Com patibilit y and 73/23 /EEC f or elect rical equipm ent used with ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 9

    C OMPLIANCES iii Australia A S/NZS 3548 (1995) - Clas s A SMC contact for products in A ustralia is: SMC Communic ations Pty . Lt d. Suit e 1 8, 1 2 Tryo n Roa d, Lindfield NSW2 070, Phone: 61-2-94160437 F ax: 61-2-9416 0474 Safety Compliance W a rn i n g : F i b e r O p t i c P o rt S a f e t y Avertissment: Ports pour fibres optiques - sécuri t? ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 10

    C OMPLIANCES iv • The socket outlet must be near to the unit and easily accessibl e. You can only remove power from the unit by di sconnecting the power cor d from the ou tlet. • This unit oper ates under SE LV (Safety Extra Low Voltage ) conditions according to IEC 60950. The conditions are onl y maintained i f the equipment to which it is con ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 11

    C OMPLIANCES v • Le coupleu r d’appareil (le connect eur du gr oupe et non pas la pri se murale) doit respecter une configurat ion qui perme t un branchement sur une entr ée d’appareil EN 6032 0/IEC 320. • La prise secteur doit se trouver à proximité de l’appareil et son accès doit ê tre facile. Vous ne pouvez mettre l’apparei l ho ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 12

    C OMPLIANCES vi • Die Ne tzsteck dose mu ß in der Nähe des Geräts und leicht zu gänglic h sein. Die Strom versorgu ng de s Geräts kann nur du rch He rausziehe n des Geräte netzkabel s aus d er Netzste ckdose u nterbr ochen w erden. • Der Bet rieb d ieses Geräts er folgt unter den SELV-Bed ingungen (Sicherheitskl einstspannung) gemäß IE ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 13

    C OMPLIANCES vii Wa r n i n g s (in Ge r man) En vironmental Statement The manufact urer of t his product en deavours to susta in an environmen tally- friend ly policy throughout the ent ire pr oduction pr ocess. This is achieved tho ugh the fol lowing mean s: • Adherence to national legis lation and regulations on environmental production standa ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 14

    C OMPLIANCES viii Audie nce This guide is for system administrators with a w orking knowledge of network management. Y o u shou ld be familia r wit h swit ching and net w o rking conce pts. Zielgr uppe Dies er Anlei tung i st fuer S ys temadmi nistr atoren mi t Erfahrung i m Netzwer k- mangement. Sie sollte n mit Sw itch - und N etzw erkk onzepten ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 15

    ix T ABLE OF C ONTENTS 1 About the TigerStack III 10/100 . . . . . . . . . . . . . . . . . . . 1-1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Switch Architectu re . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Power-o ver-Etherne t Capability . . ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 16

    T ABLE OF C ONTENTS x Mountin g . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Rack Mou nting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Deskt op or Shel f Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7 Installing an SFP ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 17

    T ABLE OF C ONTENTS xi A PPEN DICES : A Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Diagnos ing Switch Ind icators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 Diagnos ing Power Pro blems with the LED Indic ators . . . . . . . . . A-2 Power and Cooling Prob lems . . . . . . . . . . ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 18

    xii T ABLES Table 1-1 Port Statu s LED In dicato rs . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Table 1-2 Syste m Status LED In dicato rs . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Table 3-1 Serial C able Wirin g . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-13 Table 4-1 Maximum 1000BASE-T Gigab it Ethernet ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 19

    xiii F IGUR ES Figure 1-1 Front and Rear Panel s. . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Figur e 1-2 Port L ED Indica tors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Figure 1-3 System L ED Indica tors . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Figur e 1-4 Stack Ma ster Butto n . . . . . . . . . . . ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 20

    F IGU RES xiv ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 21

    1-1 C HAPTER 1 A BO UT THE T IGER S TACK III 10/100 Overvi ew SMC’ s Tig erStack III 10/100 SMC6826MPE is a 24-P or t F ast Ether net P oE Switch with 24 10B ASE-T/100B ASE -TX RJ-45 ports and two combination por ts — 10/100/1000B ASE -T ports that operate in combin ati on with Smal l F or m Fact or Plug gable (SFP) tra nscei v er sl ots * . An ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 22

    A BOUT THE T IGE R S TAC K III 10 /100 1-2 Figure 1-1 Front and Rear Panels. Switch Architecture Th e swit c h em plo ys a wir e-speed , non-block ing sw itching fabr ic . Th is per mits simultaneous wire-spee d tran s por t of multiple packets at low latency on all por ts . T he switch also features full-duplex capability on all ports , whic h eff ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 23

    O VER VI EW 1-3 from the switc h o ver th e Ethernet cab le wit hout requirin g its o wn separa te po w er source . This cap ab ili ty gi v es netw ork admini st rator s c entra lized po w er con trol f or devices s uch as I P phon es an d wi reless access poi nts , which translate s into g reater n etw o rk av ailability . F or each attac hed 802. ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 24

    A BOUT THE T IGE R S TAC K III 10 /100 1-4 Description of Hard ware 10/10 0BASE -T Port s The P oE switch base unit contains 24 10B ASE-T/100B ASE-TX RJ-45 ports . Al l ports s upport aut omat ic MDI/ MDI- X op eratio n, s o y o u can us e straigh t-thr ough cab les fo r all network conn ection s to PCs or ser vers, or to other switches or hubs . ( ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 25

    D ESCRIPTION OF H ARD W ARE 1-5 Port and System Stat us LED Indicat ors Th e switc h base unit also includes a display panel for key syste m and port indic ations tha t simplify installa tion and ne tw ork trou bles hooting . Th e LED ind icators , which are locat ed on th e front pa nel for easy viewing, are shown below a nd des cribed in th e fol ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 26

    A BOUT THE T IGE R S TAC K III 10 /100 1-6 1~24 (PoE Mode) On Green Powered device is conne cted, but not dra wing power. Flashing G reen Powered d evice is receivi ng power. Flashing Amber Port has de tected a power ove r load or short circuit and sh ut down the por t’s powe r. On Am ber The power bu dget for the switch has bee n exceede d and t ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 27

    D ESCRIPTION OF H ARD W ARE 1-7 Figure 1-3 System LED Indicators Table 1-2 System Status LED Indicators LED Co ndition Status PWR On Green Unit’s int ernal power supp ly is operating normally. Off Unit has no powe r connected. Diag On Green Syst em diagnosti c test successfu lly completed. Flashing Green S ystem diag nostic test is in progress. O ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 28

    A BOUT THE T IGE R S TAC K III 10 /100 1-8 Stack Master Button Th e unit a lso incl udes a Sta c k Ma ster butt on shown in the fo llo wing diag ra m. Figure 1-4 Stack Master Button Th e Stack Mast er but ton ena bles one switch in the stack to be se lected as the mas ter . Stacking On Green This switch is acting as the mas ter unit in the stac k. ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 29

    D ESCRIPTION OF H ARD W ARE 1-9 Mode PoE/Li nk Button Th e Mod e P o E/Li nk butt on is loca ted on the fro nt pane l. Figure 1-5 Mode Selection Th e Mod e P o E/L ink bu tton is used t o tog g le betwee n the tw o por t stat us LED display modes (see “P o rt Status LED Indicators ” on pag e 1-5). Pres sing this button chang es fr om one d ispl ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 30

    A BOUT THE T IGE R S TAC K III 10 /100 1-10 togethe r using stac king cables (one s tac king c able is in cluded w ith eac h optio nal sta c ki ng tran sceiver). T he pu sh butt on on the sw itch’ s fron t pane l ena bles one swit ch in the stack to be sel ected as th e mast er . ( See “S tack Mast er Butt on” on pa ge 1- 8.) Power Supply Soc ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 31

    F EATURES AND B ENEFITS 1-11 • Uns hielded (U TP) cable support ed on all RJ-45 ports: Ca tegory 3 or better for 10 Mbps connections, Category 5 or b etter for 100 Mbps connections, and Category 5, 5e o r 6 for 1000 Mbps connections • IEEE 802.3-2002 Ethernet, Fast E thernet, Gigabit Ethernet, and flow control c ompliance ensures comp atibility ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 32

    A BOUT THE T IGE R S TAC K III 10 /100 1-12 Management • “At -a-glance ” LED i ndicat ors for ea sy trouble shoo ting • Network manageme nt agent: - Manages swit ch (or entire stac k) in-band o r out- of-band - Supports console, Telnet, SSH, SNMP v1/v2c/v3, 4 RMON group s and we b-base d inter face ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 33

    2-1 C HAPTER 2 N ETWORK P LANNING Introd ucti on to Switchi ng A network swit c h allows s im ultaneous tran smission of multiple packets via non-cr ossbar switching . This means that it can par tition a network more effi cientl y th an br idges o r rout ers . The sw itc h has , the refo re, been recog nized as o ne of th e most i mpor tant bu ildi ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 34

    N ETWORK P LANNING 2-2 Applicat ion Examp les Th e swit c h is no t only de signed to segm ent your network, but al so to provide a wide rang e of opt ions in se tting up net w ork con nectio ns . So me typical app lications are described below . Supplying PoE Th e switch is an ex cellent choice for supplying po wer to connect ed P o E devices suc ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 35

    A PPL IC AT IO N E XAM PL ES 2-3 Collapsed Backbone The switc h is an ex cellent c h oi ce for m ix ed E thernet, F ast Ethe r net, and Gig abit Ethe rn et installations in which significant g rowth is expecte d in the near future . Y o u can easily build on th is basic configuration, adding direct full- dupl ex con nect ions t o w orkstatio ns or ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 36

    N ETWORK P LANNING 2-4 Network Aggregation Plan With 24 parallel brid ging por ts (i.e., 24 distinct collisio n domains) , the switch can collapse a co mplex network down into a single effic ient bridg ed node, in crea sing overall ban dwidth a nd thro ugh put. When up to e igh t sw itc h u nit s are s tac ked t ogether , th ey form a sin gle “vi ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 37

    A PPL IC AT IO N E XAM PL ES 2-5 Remote Connections with Fiber Cable Fiber optic t echnolo g y allows for lo ng er cabli ng than any o ther me dia type. Using a 1000B A SE-SX m u ltimode fiber (MMF) SFP tran sceiv er, you ca n r un a link up to 550 m, a 1000B ASE-LX single-mode fiber (SMF) link can r un up to 5 km, and a 1000B ASE-LH single-mode fi ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 38

    N ETWORK P LANNING 2-6 Makin g VL AN Co nnectio ns This s wit ch supports VL ANs whi ch can b e used t o organiz e a ny group o f network no des into sepa rate broa dcas t domains. VLANs co nfine broad cast traffic to the or iginating g r oup , and ca n elim inat e broad cast stor ms in la rge networks . Thi s provides a more sec ure an d clea ner ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 39

    A PP LICA T IO N N OTES 2-7 Applic ation N otes 1. Ful l-duplex operation on ly applies to point -to-point access (such as when a switc h is attac hed t o a w orkstation, ser v er or another switc h ). When the switc h is co nnec ted t o a hub , both device s m ust opera te i n half-duplex mo de . 2. A void usin g fl ow control o n a por t conne ct ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 40

    N ETWORK P LANNING 2-8 ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 41

    3-1 C HAPTER 3 I NSTALLI NG THE S WITC H Selecting a Site Switch units ca n be moun ted in a standard 19-inch equipment rack or on a flat s urface . Be sure to follow the guidelin es below when choosing a locatio n. •T h e s i t e s h o u l d : - be at the cent er of all the d evices you want to l ink and ne ar a pow er outl et. - be able to main ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 42

    I NS TA LLI NG THE S WITCH 3-2 • As with any equipment, usin g a filter or surge suppress or is reco mmende d. Ethe rnet Ca bling T o ens ure proper operation when installing the switch into a network, mak e sur e tha t the current cables are suit able fo r 10B ASE-T or 100B ASE-TX operation. Chec k the follo wing criteria against the cur rent in ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 43

    E QUIPMEN T C HECKLIST 3-3 Equi pmen t Chec klist Aft er unp ack ing t his s witc h, ch eck t he co nten ts t o be that sure y ou hav e recei ved all the c omp onent s . Then, before begi nni ng t he in stal lat ion , be sure t hat you have all ot her ne cessa r y inst allat ion equ ipm ent. Package Contents • 2 4 - Po r t Fa s t E t h e r n e t ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 44

    I NS TA LLI NG THE S WITCH 3-4 Mount ing This s witc h can be mount ed in a stand ard 19-in ch equi pmen t rac k or on a desk top o r shelf . M ount ing inst r ucti ons for e ac h ty pe of sit e fo llo w . Rack Mounting Bef ore rack mou nti ng t he switch, pay par ticular attention to the following factors : • Temp erature: Since the tem peratur ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 45

    M OUNTING 3-5 Figure 3-2 Attaching the Brackets 2. Mount th e device in the rack, using four r ack-mounting s crews (no t provide d). Figure 3-3 Installi ng the Switch in a Rack 3. If in stalling a single switch only , tur n to “Connect ing to a P ow er Sour ce” at t he en d of thi s chapte r . 4. If in stalling multiple switches , mount them i ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 46

    I NS TA LLI NG THE S WITCH 3-6 Mont age (Rack Mounti ng In str u ctions - Ge r ma n) Switch- Einheiten k önnen an ein standardmäßig es 19-Z oll Einric htungsrac k, einen Arbeitstisc h oder ein R egal montiert werden. F olgend finden Sie die Montageanweisungen für jeden P ositio nsty p . Rack -Mon t a ge Beach ten Sie die folgenden F akt oren, b ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 47

    M OUNTING 3-7 Desktop or Sh elf Mounting 1. Attach the fou r adhesive feet to th e bottom of the first s witch. Figure 3-4 Attaching the Adhesive Feet 2. Set the device on a flat surfac e near an A C pow er s ource , making sure ther e are at leas t two inches of space on all s ides fo r prop er air f l ow . 3. If ins talling a single sw itch only ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 48

    I NS TA LLI NG THE S WITCH 3-8 Inst alling an SFP Transceiver Figure 3-5 Install ing an SFP Transceiver The SFP s lot s su pport th e fo llo wi ng o ption al SFP t ra nscei v ers: • 1000BASE-SX • 1000BASE-LX • 1000BASE-LH T o in stall an SFP transceiv e r , pe rfor m the following ste ps: 1. Con sider your netw ork and cabling requirement s t ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 49

    S TAC KIN G S WI TC HE S 3-9 Stacking Switches Th e swit c h su ppor ts s tacking up t o eight units throug h an optio nal SF P stac king t rans cei v e r . Eac h stac king conn ecti on pro vid es a 2 Gb ps high -speed link u sin g USB st acki ng cables . The stac king transc eive r must be ins talled in the por t 2 5 SFP slo t. Each stacking tran ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 50

    I NS TA LLI NG THE S WITCH 3-10 Connecting Switches in a Stack Figure 3-7 Connecting Switches in a Stack Note: The stacking tran sceiver must on ly be installed in the port 25 SFP slot. T o connect up t o eigh t sw itc h es i n a s tac k, pe rfor m th e foll ow ing s teps: 1. Install S FP stacking tr ansceiv ers in to the po rt 25 sl ot for e ach s ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 51

    S TAC KIN G S WI TC HE S 3-11 5. Complete th e sta ck co nnect ions by plu g ging one e nd of a stack cabl e into th e Tx por t on the bott om unit and the other e nd into th e Rx por t on the top unit . 6. Select the Mast er unit in th e sta ck b y pressing the p ush but ton i n on only one o f the swi tc hes . Only on e swit ch in the s tac k can ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 52

    I NS TA LLI NG THE S WITCH 3-12 Connect ing to a Pow er Source T o connect a switc h to a po w er sou rce: 1. Insert the p ow er cable plu g di rectly into t he A C sock et locate d at the back of the swit ch. Figure 3-8 Power Socket 2. Plug the ot her e nd of the cable in to a g r ounded , 3-pin soc k et, A C po w er source . Note: For inte rnati ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 53

    C ONNECTING TO THE C ONSOLE P ORT 3-13 Conne ctin g to the Co nsol e Port The DB-9 seria l po r t o n the s witc h’ s fron t panel i s used t o co nnect to th e switch for out- of-ban d conso le conf igura tion. T he comma nd-line config urati on prog r am can be accesse d from a te r minal or a PC r u nning a ter minal e mulatio n prog ra m. Th ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 54

    I NS TA LLI NG THE S WITCH 3-14 •S t o p b i t — O n e • Data bits—8 • Flow control—n one ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 55

    4-1 C HAPTER 4 M AKING N ETWORK C ONNECTI ONS Conne ctin g Network Device s The swit c h is designed to be connected to 10 or 100 Mbp s netwo rk cards in PCs an d ser ve rs , as well as to other switc h es an d hubs . It may also be connected to remote devices using the optional 1000B ASE -X, or 100B ASE-FX SFP transcei ve rs . If 802.3af-compliant ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 56

    M AKI NG N ETWORK C ONNECTIONS 4-2 Power-over-Ethernet Connections The P oE switch automatically detects an 802.3af-compliant device b y its auth enti cate d P oE s ign ature and se nses its req uir ed l oad be fore t urning o n DC power to the por t. T his detection mechanism prevents damag e to other netw ork equipment that is not 802.3af complia ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 57

    T WISTED -P AI R D EV IC ES 4-3 Cabling Guidelines Th e RJ-45 por ts on the switch supp ort aut omatic MD I/MDI- X pinout config urati on, s o you c an u se st andar d str aight-th rough twist ed-pa ir ca bles to co nnect to any o ther net w ork d evice (PCs , s er ve rs , switc hes , r outer s , or hub s). See Appen dix B for further infor mation ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 58

    M AKI NG N ETWORK C ONNECTIONS 4-4 3. If the devi ce i s a ne tw ork card an d the s witc h i s in t he wiri ng cl oset , attach t he othe r end of th e cab le se gment to a modu lar wall ou tlet th at is co nnect ed to the wirin g clos et. (See t he s ection “Netw ork Wiri ng Conn ectio ns” on page 4- 4) O ther wis e, atta c h th e ot her en d ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 59

    T WISTED -P AI R D EV IC ES 4-5 Figure 4-2 Network Wiring Connections Equipment Rack (side view) Switch Patch Panel Punch-Down Block Wa l l 12 3 4 56 7 89 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 26 Console 25 1 2 11 12 13 14 23 24 Link/Act PoE 25 26 Pwr Diag Stack Mode PoE/Link RPS ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 60

    M AKI NG N ETWORK C ONNECTIONS 4-6 Fiber Optic Devices An optional slide-in 1000B ASE-SX, 1000B ASE-LX, 1000BASE -LH, or 100B ASE-FX SFP transcei v er ma y be used for bac kbone o r remote conn ection s , or for conne cting t o a high-sp eed se r ver . Each single-mode fiber o ptic port requires 9/125 micro n single-mode fibe r optic cabling w ith ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 61

    C ONNEC TI VITY R ULES 4-7 3. Connect o ne en d of t he cab le t o the LC p ort on the swi tc h and the other end t o th e port on th e other device. Since LC conn ec tors are ke yed, the cabl e ca n be a ttac hed in on ly one o rien tati on. Figure 4-3 Making Fiber Port Connections 4. As a conn ection is made , chec k the g reen Lin k LED o n the ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 62

    M AKI NG N ETWORK C ONNECTIONS 4-8 1000BASE-T Cable R equirements All Categ or y 5 UTP cab les that are used for 100B A SE-TX connections should also w ork for 1000B A SE-T , providing that all four wire pairs a re conne cted. Howev er , it is recomme nded that for all critical con nections, or any new cabl e inst allat ions , Categor y 5e (enh anc ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 63

    C AB LE L ABELIN G AND C ONNECTION R ECO RDS 4-9 Table 4-4 Maximum 1000BASE-LH Gigabit Ethernet Cable Length 100 Mbps Fast Ether net Collision Domain Table 4-5 Maximum Fast Ethernet Cable Lengths 10 Mbps Ethern et Collision Domain Table 4-6 Maximum Ethernet Cable Length Cable L abeli ng and Conne ctio n Recor ds Whe n planning a netw ork ins tallat ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 64

    M AKI NG N ETWORK C ONNECTIONS 4-10 T o best man age th e ph ysical im pl ement ati ons of y our netw or k, fol lo w these g uidelines: • Cle arly lab el th e opp osing ends of each ca ble. • Using your buil ding ’s flo or pl ans, draw a map of th e lo cation of al l netwo rk-conn ected e quipm ent. F or ea ch piece of eq uipmen t, ide nti fy ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 65

    A-1 A PPENDI X A T ROUBLESHOOTING Diagnosi ng Switc h Indica tors Table A-1 Tr oubleshooting Chart Symptom Action PWR LED is Off • Intern al power s upply may be di sconnected . Check c onnections between t he swit ch, the power cor d and t he wall outlet . Diag LED i s Amber • The sy stem has d etecte d a faul t. Power cycl e the sw itch to t ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 66

    T R OUBLESHOOTING A-2 Diagnosing Power Problems with th e LED Indicators Th e P ower and RPU LED indicators work in combination to indicate pow er status as follows . Table A-2 Power/RPU LED Indicators Power and Coolin g Problems If the power ind icator does not tu r n on when the power cord is pl ug ge d in, y ou ma y hav e a prob lem w ith th e p ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 67

    I NSTALLATION A-3 Inst allatio n V erify that all syst em co mponen ts ha v e been pr operly ins talled. If on e or more c ompon ents ap pear to be m alfunct ioni ng (such a s the power c ord or netw ork cabl ing) , tes t th em in an alt ernate en vi r onment wher e y ou are sure tha t al l the o ther components ar e funct ion ing p roperl y . In-B ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 68

    T R OUBLESHOOTING A-4 Stack Tr oubleshooting If a stack fails to initialize or fun ction, first check the following items : • Check that all s tacking cables are pr operly conne cted. • Check if any stac king cab les app ear damaged . • Check that only o ne Mas ter S elect butto n is p resse d in . • Chec k that all switc hes in the stack a ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 69

    B-1 A PPEND IX B C ABLES Twi sted-Pai r Cable and Pin Assi gnments F or 10/100 B A SE-TX c onnec tions, the twiste d-pair cabl e must have tw o pairs of wires . F or 1000B A SE-T connections the twisted-pair cable m ust hav e fou r pairs of wir es . E ach wire pa ir is ident ified b y tw o different col ors . F or exam ple, on e wir e mig ht be g r ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 70

    C AB LES B-2 10/100BASE-TX P in Assign ments Use unshield ed twisted-pair (UTP) or shielded t wisted-pair (STP) ca ble for RJ-45 connections: 100-ohm Categ or y 3 or better cable for 10 Mbps connectio ns , or 100-o hm Categ or y 5 or be tter cabl e for 100 Mbps conn ection s . Al so be s ure that the len g th of any twist ed-p air conn ection does ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 71

    T WISTED -P AI R C AB LE AND P IN A SSIGNMENTS B-3 Straight-Thr ough Wiring If the twis ted-pair cable is to join two port s and only o ne of the por ts has an inter nal crossover (MDI-X ), the two pairs of wires mus t be st raight -th roug h. ( Whe n auto -negoti atio n is en abl ed for a ny RJ-45 port on this swit ch, you can use ei the r str aig ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 72

    C AB LES B-4 Cros sover Wirin g If the twisted-p air cable is to jo in tw o por ts and either both p ort s are labeled with an “X” (MDI-X) or neit her por t is labeled with an “X” (MDI), a cros so ver must be imple mente d in the wi ring . (When au to- nego tia tion is ena ble d for a ny RJ -45 port on t his s witch, you c an use eith er st ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 73

    T WISTED -P AI R C AB LE AND P IN A SSIGNMENTS B-5 1000BASE-T Pin As signments All 1000B A SE-T ports suppor t automatic MDI/MDI-X operatio n, so y ou can use st raig ht-t hr ough cabl es for all netw ork conn ection s to PCs or ser v ers , or to ot he r swit ch es or hub s . The table below shows the 1000B ASE-T MD I-X and MDI port pinouts . Th es ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 74

    C AB LES B-6 Table B-2 1000BASE-T M DI-X and MDI Port Pinouts Cable Testing for Existing Category 5 Cable Installed Categ or y 5 cabling must pass tes ts for Attenuation, Near-End Cros stalk (NEXT), and F ar-En d Crosstalk ( FEXT). This cable testing infor mation is spe cified in the AN SI/TIA/E IA- TSB-67 st andard. Ca bles must also pa ss test pa ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 75

    F IBER S TAN DAR DS B-7 Adjusting Exi sting Category 5 Cabling to Run 1000BASE-T If y our existing Cat egor y 5 inst allat ion does not meet one o f the test parameters for 1000B ASE-T , there are basically three measures that can be applied to tr y to c or rect the problem: 1. R eplace any Categor y 5 patch cable s with hi gh -perf or mance Catego ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 76

    C AB LES B-8 ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 77

    C-1 A PPENDIX C S PECIFICATIONS Physical Chara c teristi cs Po r t s 24 10/100B ASE-TX, with auto-neg otiation 2 1000B ASE-T/SFP combination por ts Network Interface P or ts 1-24: RJ-45 connector , auto MDI/X 10B ASE-T : RJ-45 (100-ohm, UTP cable; Categ ories 3 or b etter) 100B ASE-TX: RJ-45 (100-ohm, UTP cable; Categ or y 5 or better) P or ts 25, ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 78

    S PE CIF IC AT I O NS C-2 P ow er Consumption 48 W a tts (Sw itching syst em) 375 W att s (P ower -ove r-Ethern et) Maximum C ur rent 6.8 A @ 100 V A C 3.2 A @ 240 V A C LED Indicators System: PWR, Diag, RPS , Stacking Po r t s : Link/Act, P oE We i g h t 5.76 kg (12.70 lbs) Size 44.0 x 41.0 x 4.3 cm (17.32 x 16.14 x 1.69 in.) Te m p e r a t u r e ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 79

    M ANAG EMEN T F EAT UR E S C-3 Manage ment Feat ures In-Band Managem ent W eb , T elnet, SSH, or SNMP manager Out-of-Band Mana gement RS-232 DB-9 console port Software Load ing TFTP i n- band, o r XM odem out-of -band Standards IEEE 802.3-2002 Ethe rnet, F ast E thernet, Gigabi t Et hernet, Full-d uplex f low control IEEE 802.3af P ower -o v er-Eth ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 80

    S PE CIF IC AT I O NS C-4 Compliance s CE Mark Emissi ons Indu str y Cana da Cla ss A EN55022 (CISPR 22) Class A FCC Clas s A Indu str y Cana da Cla ss A EN55022 (CISPR 22) Class A EN 61000-3-2/3 V CCI Class A C-Tick - AS/NZS 3548 (199 5) Class A Immunity EN 61000-4-2/3/4/5/6/8/11 Safety CSA/CUS (CSA60950-1 & UL60950-1) TÜV/GS (EN60950-1) CB ( ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 81

    D-1 A PPEND IX D O RDERING I NFORMATION Table D-1 Tiger Stack III 10 /100 Products and Accessories Product Numb er Description SMC6826MPE 24-port 10/100 stackable PoE swi tch with 2 Gigabit combination 1000BASE- T/SFP ports SMC6824S-P Tig erStack III 10 /100 Stack ing Kit (in cludes 1 m stacking cable ) SMCBGSLCX1 1-p ort 1000BASE-SX Small Form Plu ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 82

    O RDER ING I NFOR MATION D-2 ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 83

    Glossary-1 G LOSSARY 10BASE-T IEEE 802.3 specification for 10 Mbps Ethern et o v er tw o pairs of Categ or y 3, 4, or 5 UTP cable . 100BASE-FX IEEE 802.3u specification for F a st Ethernet ov er tw o strands o f 50/125, 62.5/125 or 9/125 micron co re fiber cable . 100BASE-TX IEEE 802.3u specification for 100 Mbps Ethern et o v er tw o pairs of Cate ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 84

    G LOSSAR Y Glossary-2 Auto-Negot iation Sign alling meth od allowing each nod e to select its opti mu m ope ratio nal mode (e.g ., spe ed and duplex mod e) based on the capabilit ies of the nod e to whic h it is connect ed. Bandwidth The differ ence b etween t he h igh est a nd l ow est frequ encie s a vaila ble for network sign als . A lso sy nony ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 85

    G LOSSAR Y Glossary-3 Fast Ethernet A 100 Mbps network c ommunication system based o n Ether net and the CSMA/CD access method. Gigabit Ethernet A 1000 Mbps network c ommunication system based on Ethernet and the CSMA/CD access method. Full Duplex T ransmi ssion meth od that al lows tw o network device s to tra nsmit and recei ve c oncurrently , ef ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 86

    G LOSSAR Y Glossary-4 IEEE 802.3x Defi nes Ethe r net fr ame sta rt/sto p r equest s a nd ti mer s u sed f or flo w control on full-duplex links . (Now incorporated in IEEE 802.3-2002.) IEEE 802.3z Defin es CSMA/ CD acce ss met hod a nd ph ysical l ayer specificat ions fo r 1000B ASE Gigabit Ether net ov er fiber cabling . (Now inco rporated in IEE ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 87

    G LOSSAR Y Glossary-5 Network Diameter Wire distan ce between tw o end stations in the same col lision domain. Redundant Power Supply (RPS) A backup pow e r supply unit that automat ically takes o ver in case th e primar y power supply should fail. RJ-45 Connector A co nnect or fo r twi ste d-pa ir wi r ing . Switched Ports P or ts th at are on sep ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 88

    G LOSSAR Y Glossary-6 ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 89

    Index-1 Numeri cs 10 Mbps conne ctivity rules 4-6 100 Mbps conn ectivity rules 4-6 1000 Mbps conn ectivity rules 4-5 100BASE cable leng ths 4-6 100BASE-TX p orts 1-3 10BASE cabl e lengths 4- 6 10BASE-T ports 1-3 A adhesi ve feet, attachin g 3-6 air flow requirements 3 -1 applica tions central wiring cl oset 2- 3 collapse d backbone 2-2 remote conne ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 90

    I ND EX Index-2 I IEEE 802.3x flow control 1- 3 indicators , LED 1-3 installatio n connecting devices to the switch 4-2 network wiring conn ections 4-3 port connect ions 4-1 power requirements 3-1 problems A-2 rack mounting 3-3 SFP transceivers 3-7 site requirements 3-1 L laser safe ty 4-4 LED indicators Diag 1-5 Power 1-5 problems A-1 Stack 1-5 lo ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 91

    I NDEX Index-3 stan dards compliance C-2 IEEE C- 3 status L EDs 1- 3 surge supp ressor, using 3-1 switch a rchitecture 1-2 switching introduc tion to 2-1 method 1 -2 T Telnet A-3 te mp era tu r e w it hi n a rac k 3-3 trouble shooting in-ba nd access A -3 power and cooling proble ms A-2 switch ind icators A-1 twisted- pair connections 4-1 W web-ba ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 92

    I ND EX Index-4 ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 93

    ...

  • SMC Networks SMC TigerStack III SMC6826MPE - page 94

    38 T e sla Irvine, CA 9 2618 Phone: (949) 679-800 0 Model Num ber: SMC6826M PE Pub .Numbe r: 150200 037700A E062005 -R01 FOR TECHNICAL SUPPOR T , CALL: From U. S.A. and Cana da (24 hou rs a day , 7 da ys a week) (800) SMC- 4-Y OU; (94 9) 679-8000; F ax: (949 ) 679-1481 From Europe (8: 00 AM - 5:30 PM UK T ime) 44 (0) 118 97 4 8700; Fax: 44 (0) 118 ...

Manufacturer SMC Networks Category Switch

Documents that we receive from a manufacturer of a SMC Networks SMC TigerStack III SMC6826MPE can be divided into several groups. They are, among others:
- SMC Networks technical drawings
- SMC TigerStack III SMC6826MPE manuals
- SMC Networks product data sheets
- information booklets
- or energy labels SMC Networks SMC TigerStack III SMC6826MPE
All of them are important, but the most important information from the point of view of use of the device are in the user manual SMC Networks SMC TigerStack III SMC6826MPE.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals SMC Networks SMC TigerStack III SMC6826MPE, service manual, brief instructions and user manuals SMC Networks SMC TigerStack III SMC6826MPE. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product SMC Networks SMC TigerStack III SMC6826MPE.

A complete manual for the device SMC Networks SMC TigerStack III SMC6826MPE, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use SMC Networks SMC TigerStack III SMC6826MPE by users. Manuals are usually written by a technical writer, but in a language understandable to all users of SMC Networks SMC TigerStack III SMC6826MPE.

A complete SMC Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual SMC Networks SMC TigerStack III SMC6826MPE - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the SMC Networks SMC TigerStack III SMC6826MPE, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the SMC Networks SMC TigerStack III SMC6826MPE, that we can find in the current document
3. Tips how to use the basic functions of the device SMC Networks SMC TigerStack III SMC6826MPE - which should help us in our first steps of using SMC Networks SMC TigerStack III SMC6826MPE
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with SMC Networks SMC TigerStack III SMC6826MPE
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of SMC Networks SMC TigerStack III SMC6826MPE in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning SMC Networks SMC TigerStack III SMC6826MPE?

Use the form below

If you did not solve your problem by using a manual SMC Networks SMC TigerStack III SMC6826MPE, ask a question using the form below. If a user had a similar problem with SMC Networks SMC TigerStack III SMC6826MPE it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)