Manual Princeton 4411-0106

136 pages 5.19 mb
Download

Go to site of 136

Summary
  • Princeton 4411-0106 - page 1

    4411 -0106 Version 2. C July 2, 2013 *4411-0 106* ...

  • Princeton 4411-0106 - page 2

     Copyright 200 4-2013 Princeton I nstruments, a div ision of Roper Scien tific, Inc. 3660 Quakerbridg e Rd Trenton, NJ 08619 TEL: 800-874- 9789 / 609-587- 9797 FAX: 609-587- 1970 All rights reserv ed. No part of this publication may be reproduced by any means without the wr itten permission of Pri nceton Instrum ents, a division of Roper Scienti ...

  • Princeton 4411-0106 - page 3

    iii Table of Contents Chapter 1 Introduction ......................................................................................... 9 PIXI S .................................................................................................................................. 9 eXcelon ® .............................................................. ...

  • Princeton 4411-0106 - page 4

    iv PIXIS Sy stem Manual Version 2.C Chapter 6 Advanced Topics ............................................................................. 67 Introduction ....................................................................................................................... 67 Timing Modes .......................................................... ...

  • Princeton 4411-0106 - page 5

    Table of Conten ts v v Appendix C Adapte r Adjustment and F ocusing Procedures ...................... 109 Adjustable C- Mount Adapter .......................................................................................... 109 F-Mount Adapter Foc using Procedure ............................................................................ 110 Lens ...

  • Princeton 4411-0106 - page 6

    vi PIXIS Sy stem Manual Version 2. C Figure 23. WinX D et ector Tem per ature dialog .............................................................. 57 Figure 24. Array T erms for a CCD with a Dual Output Am pl ifier ................................ 59 Figure 25. Full Fram e a t Full Resolut ion ...................................................... ...

  • Princeton 4411-0106 - page 7

    Table of Conten ts vii vii Tables Table 1. USB Driv er Files and Loc ations ........................................................................ 26 Table 2. Exam ple of Controller Ga i n {Analog G ain} vs. Readout Port .......................... 64 Table 3. Cam era Timing Modes ................................................................... ...

  • Princeton 4411-0106 - page 8

    viii PIXIS Sy stem Manual Version 2.C This page intentionally left blank. ...

  • Princeton 4411-0106 - page 9

    9 Chapter 1 Introduction PIXIS Thank y ou for purchasing a PI X IS camera system from Princeton I nstruments. For over two dec ades Princeton I nstruments has been t he legendary nam e behind the m ost revolution ary spectroscopy and imaging pr oducts for cutting edge resea rch. PIXI S represents the most a dvanced cam era design and utilizes yea r ...

  • Princeton 4411-0106 - page 10

    10 PIXIS Sy stem Manual Version 2.C Grounding and Safety Before turning on the power supp ly (air-cooled system or liquid-cooled system with a CoolCUBE II circulator), th e ground prong of the power cord pl ug m ust be properly connected to the g round connector o f the wall out let. The wall ou t let must have a third prong, or must be properly co ...

  • Princeton 4411-0106 - page 11

    Chapter 1 Introduct ion 11 11 Cleaning Turn off all power to the equipm ent an d secure all cov ers before c leaning the units . Otherwise, dam age to the equipment or injury to you could occu r . Camera Although there is no periodic m ai ntenance that needs t o be perform ed on a PIXI S camera, users are advised to wipe it down with a c lean dam p ...

  • Princeton 4411-0106 - page 12

    12 PIXIS Sy stem Manual Version 2.C Chapter 1 , Int roduction prov ides an overv i ew of the PI X IS cam eras. Chapter 2, System Component D escriptions prov ides information abou t the camera, interfa ce card, cabl es and application software. Chapter 3, Insta llation Overv iew cross-reference s system setup ac tions with the relevant m anuals and ...

  • Princeton 4411-0106 - page 13

    13 Chapter 2 System Component Descriptions System Components Standard Components A typical air- cooled PIXI S system consists of the cam er a with a Cer tificate of Performance, a p ower supply , a USB 2.0 interfa ce cable for y our computer system , MCX to BNC adapte r cables, and the user manual. A typic al liquid-cooled PIXI S system consists of ...

  • Princeton 4411-0106 - page 14

    14 PIXIS Sy stem Manual Version 2.C PIXIS Camera CCD Array: The PI X IS cam era system offers both front- and back- illuminated CC Ds in a variety of array sizes that a llow you to preci sely match the sensor t o your applicat ion. Only scient ific-grade devices are used in order to ensure the hig hest imag e fidelity, resolution, and acquisition f ...

  • Princeton 4411-0106 - page 15

    Chapter 2 System Component Descri ptions 15 15 Fan : Ai r-c ool ed came ras co ntain an in tern al fa n. Its purp ose i s:  to remov e heat from the Pel tier device that coo l s the CC D array and  to cool the ele ctronics. An internal Pel tier device direct ly cools the co ld finger on which the CCD is m ount ed. The air drawn into the camer ...

  • Princeton 4411-0106 - page 16

    16 PIXIS Sy stem Manual Version 2.C Cables USB 2.0 Cable : The sta ndard 16.4' (5 m) cable (6050-0494) has USB conn ectors that interconnect the "USB 2.0" connecto r on the rear o f the PI XIS with a USB card in st alled in the host com put er. MCX to BNC Adapter Cab les : Two MCX to BNC adapter cab l es are provided with the PIXI S ...

  • Princeton 4411-0106 - page 17

    Chapter 2 System Component Descri ptions 17 17 Optional Components Application Software WinX: The PI XIS camera can be ope r ated by using either WinView/32 or WinSpec/32, Princ eton I nstrument's 32-bit Windows ® softw are packages des igned specifically fo r high-end imaging and s pectroscopy, re spectively . The Princeton Instrum ents&apos ...

  • Princeton 4411-0106 - page 18

    18 PIXIS Sy stem Manual Version 2.C Internal Shutte r Optional 25 or 45 m m internal shutter (dependent on C CD array size). Shutters are mechanical dev ices with a fini te lifetime, typically of the order of a million cy cles, although som e individual shutters m ay last a good dea l longer. How long a shutter last s in terms of experim ent al tim ...

  • Princeton 4411-0106 - page 19

    19 Chapter 3 Initial System Verification The list and diagrams below briefly describe the sequence of actions required to install your system and prepare to gather data. Refer to the indicated ref erences for more detailed in formation. Action Reference 1. If the system components hav e not already been u npacked, unpack them and inspec t their car ...

  • Princeton 4411-0106 - page 20

    20 PIXIS Sy stem Manual Version 2.C Action Reference 14. Adjust the focus for the best im age or spectral l ines. If you are using WinSpec/32, y ou may want to use the Focus He l per function for spectroscopy app lications. If you are u sing LightField, you may want to use the Alig n Spectrom et er function. Chapter 5 Opera tion, page 45 or pag e 4 ...

  • Princeton 4411-0106 - page 21

    Chapter 3 Initial System Verifi cation 21 21 Figure 4. Typical Imaging Experiment Layo ut (Liquid -coo led Camera with CoolCUBE II ) Figure 5. Typical Spectroscopy Exp eriment Layout (Liquid -coo led Camera with CoolCUBE II ) ...

  • Princeton 4411-0106 - page 22

    22 PIXIS Sy stem Manual Version 2.C This page intentionally left blank. ...

  • Princeton 4411-0106 - page 23

    23 Chapter 4 System Setup To minimiz e risk to users or to sy st em equipm ent, turn the system OFF before any cables are connected or disconnected. Introduction A PIXIS camera sy stem consists of thre e hardware co mponents:  Camera head  Power supply  Cables All of the com ponents and cables required fo r your configura tion are included ...

  • Princeton 4411-0106 - page 24

    24 PIXIS Sy stem Manual Version 2.C Checking the Equipment and Parts Inventory Confirm that y ou have all of the equ i pment and par ts required to set up the PI X IS system . A complete syst em consists of: Standard System :  Camera and Power Supply  CoolCUBE II Circulator and hoses (for liquid-coole d system)  Host Computer: Can be purch ...

  • Princeton 4411-0106 - page 25

    Chapter 4 System Setup 25 25 Ventilation: Allow at least on e inch clearan ce for the side air vent s. Where the ca mera is inside an enclos ure, > 30 cfm air circulation and he at dissipation of 100W is req uir ed. Power: The PIXI S camera receives its powe r from the supp lied power supply which in turn plugs into an AC power source. Host Comp ...

  • Princeton 4411-0106 - page 26

    26 PIXIS Sy stem Manual Version 2.C Software Installation WinX Notes: 1. Before proceeding , please check t o see if your com puter supports USB 2.0. I f it do es not, install a USB 2. 0 i nterface c ard. Follow the m anufacturer’s instruction s . 2. Leave the USB c able disconnected f rom the cam era until you have installed WinView/32 or WinSpe ...

  • Princeton 4411-0106 - page 27

    Chapter 4 System Setup 27 27 LightField The following installation is perform ed via the LightF ield software installation C D. 1. Before starting the installation:  Verify that the computer op erating system is Windows Vista (64-bit ) or Windows 7 (64- bi t).  Confirm that your computer supports USB 2.0. If it do es not, please r efer to the ...

  • Princeton 4411-0106 - page 28

    28 PIXIS Sy stem Manual Version 2.C Notes: 1. Make sure that there are no kinks in the hoses that im pede the coolant flow. Lack of sufficient f low can seriously harm the detecto r and any resulting dam age is not covered under warr anty. 2. Damage caused by water leak ing into the PIXI S voids the warranty. 5. Unscrew the reserv oir cap (on top o ...

  • Princeton 4411-0106 - page 29

    Chapter 4 System Setup 29 29 Entering the Default Camera System Parameter s The following instructions assum e t hat you hav e perform ed the compute r interf ace installation. WinX 1. Ma ke s ur e the P I XI S is co nnec te d to t he h os t com pu ter an d th at i t is t ur ned o n. 2. R un t he W in X a pp lic at io n. Th e C am er a D et ec ti o ...

  • Princeton 4411-0106 - page 30

    30 PIXIS Sy stem Manual Version 2.C Figure 9. LightField Experiment Workspa ce 5. Because this is a new experim ent , the default set tings will autom ati cally be entered for the exp eriment device(s). These se ttings will allow you to beg in previewing ( Run butt on) or acquir ing ( Acquire button ) data. Note: For a step- by-step procedu re on b ...

  • Princeton 4411-0106 - page 31

    Chapter 4 System Setup 31 31 Attaching to an F-Mount Adapter F-mount adapte rs use the Nik on bayonet format. To mount the lens on the cam era: 1. Locate the large in di cator dot on t he side of the lens. 2. Note the correspo nding dot on the fr ont side of th e adapter. 3. Line up the dots and slide the lens i nto the adapte r. 4. Tu rn t he le n ...

  • Princeton 4411-0106 - page 32

    32 PIXIS Sy stem Manual Version 2.C 6. When you have f inished with focus i ng and rotational a l ignment, secu re the sliding tube in pl ace with the spe ctrograph setscrews. 7. If they hav e a lready been install ed, loosen the ada pter’s two re cessed locking setscrews (use a 0.050 hex key). If they hav e not been ins talled, insert the setscr ...

  • Princeton 4411-0106 - page 33

    Chapter 4 System Setup 33 33 Connecting an External Shutter Disconnecting or connecting the shutter cabl e to the cam era whil e the cam er a is ON can destroy the shutter or the shutter driv er in the cam era! Introduction Typically, PI X IS cam eras for imaging applicat ions are shipp ed with an inte rnal shutter. The 25 or 45 mm i nternal shutte ...

  • Princeton 4411-0106 - page 34

    34 PIXIS Sy stem Manual Version 2.C Overexposure Protection Cameras that are e xposed to room l ight or other cont inuous light so urces will quic kly become satura ted. This mos t often occurs whe n operating wit hout a shutter. I f the cam e r a is mounted to a spec trograph, clo se the entranc e slit of the spectrog raph to reduce the incident l ...

  • Princeton 4411-0106 - page 35

    35 Chapter 5 Operation Introduction Once the PI X IS camera has been installed as explained in the preceding chapters, operation o f the cam era is straightforward. I n most appli cations you sim pl y establish optimum performance using t he Focus mode (in WinX, for example), set th e t arget cam era t emperatur e, wait until the temperature has st ...

  • Princeton 4411-0106 - page 36

    36 PIXIS Sy stem Manual Version 2.C The remainder o f this chapter pr ovides "First Lig ht" procedures (these provide st ep- by - step instruction on how to initially verify system operation) and discus ses factors that affect exposure, r eadout, and digit ization of the in coming sig nal. By understandin g the ex posure, readout, and dig ...

  • Princeton 4411-0106 - page 37

    Chapter 5 Operation 37 37 Getting Started 1. Mount a test target i n front of th e camera. 2. Power ON the cam er a (i.e., switch the power sup ply ON). Note: The cam era must be turned on b efore WinX is opened, and WinX must be closed before the c amera is turned off. 3. Turn on the com put er power. 4. Start the applica tion software. Setting th ...

  • Princeton 4411-0106 - page 38

    38 PIXIS Sy stem Manual Version 2.C Experiment Se tup Main tab (Acquis ition|Experimen t Setup…):  Exposure Time: 100 ms  Accumulations & Number of I mages: 1 Experiment Se tup ROI t ab (Acqu i sition|Expe riment Setup… ): Use this function to define the region of inte rest (ROI ).  Imaging Mode: S elect thi s mode if you are run n ...

  • Princeton 4411-0106 - page 39

    Chapter 5 Operation 39 39 Spectroscopy The foll ow ing par ag raphs prov ide ste p- by-s tep in stru cti ons for op era ting PIXI S i n a spe ctrosc opy se tup f or th e fi rst t im e. Th e i nt ent o f thi s s im ple p roced ure is to help yo u g ain bas ic fam ilia ri ty w ith th e o pera tion o f y our sy stem and to s how tha t it i s fun ction ...

  • Princeton 4411-0106 - page 40

    40 PIXIS Sy stem Manual Version 2.C  Internal Slit Shut ter: A shutter m ounted internally has an externa l shutter connector in the sidewall of the spectrograph. Connect a shutter cable f rom the PIXI S Shutter connector to tha t connector. 6. Power ON the cam er a (i.e., switch the power sup ply ON). Note: With USB 2.0, t he cam era must be tu ...

  • Princeton 4411-0106 - page 41

    Chapter 5 Operation 41 41 Experiment Se tup Main tab (Acquis i tion|Experimen t Setup…):  Exposure Time: 100 ms  Accumulations & Number of I mages: 1 Experiment Se tup ROI tab (Acqu i sition|Experi ment Setup…): Use this function to define the region of inte rest (ROI ).  Spectroscopy Mode: Selected  Clicking on Fu ll loads the ...

  • Princeton 4411-0106 - page 42

    42 PIXIS Sy stem Manual Version 2.C th e pro bl em is f ixe d, st op a cqu is iti on o r co nt in u e to th e “ F oc us ing ” t op ic on pa g e 42 ; ot her wis e, s to p d at a ac qu isi tio n and c on ti nu e to St ep g .  If you do not he ar a shutter operating and you have don e St eps a-e, stop da ta acquisition and cont inue to Step g. ...

  • Princeton 4411-0106 - page 43

    Chapter 5 Operation 43 43 2. With the spec trograph properly conn ected to the c amera, turn the powe r on, wait f or the spectrograph to i nitialize. 3. Select Define f rom the Spectrograph m enu, click on Install/ Remove Spectrogra ph , highlight the appropriate spectrograph name (for example, Acton SP300i for an Act on SP-2300i spec trograph) in ...

  • Princeton 4411-0106 - page 44

    44 PIXIS Sy stem Manual Version 2.C N o te : Wh en a lig nin g ot he r a cce ss ori es , su ch as fi be rs, le ns es, o pt ic al fi ber a da pt er s, fi rs t al ig n the sp ec tro gr ap h to th e s lit . Th en al ig n the a cce sso ry wi th ou t dis tu rbi ng th e ca m era po si tio n. Th e pro ce du re i s i den ti ca l to t hat u sed t o fo cu s ...

  • Princeton 4411-0106 - page 45

    Chapter 5 Operation 45 45 LightField First Light Instructions Imaging This sec tio n p rov ides ste p- by-s tep in stru ctio ns for acqui ring an im aging mea sur em ent in Lig htFi eld fo r the f irst tim e. Th e in tent of this proc edure is to he lp you gain basi c fam iliar ity wit h t he opera tio n o f yo ur sy stem and to show th at it i s f ...

  • Princeton 4411-0106 - page 46

    46 PIXIS Sy stem Manual Version 2.C 1. After LightFiel d opens, you shou ld see an icon repre senting y our camera in the Available D evices area. In the figure abov e, t he cam era is a PIXIS:512B eXcelon ® . 2. Drag the icon int o the Experiment D evices area. Figure 14 . Experiment D evices Area 3. Note that the Experi ment S ettings stack on t ...

  • Princeton 4411-0106 - page 47

    Chapter 5 Operation 47 47 Figur e 15 . View Area 3. Click on the Run bu t ton to star t Preview m ode. In this mode, imag es will be continuously ac quired and dis played. Figure 16 . View Area Displaying a n Image 4. Adjust the lens a perture, intensity sc aling, and focu s for the best image as v i ewed on the computer m oni tor. Som e i maging t ...

  • Princeton 4411-0106 - page 48

    48 PIXIS Sy stem Manual Version 2.C  C he ck th e br ig hte st r eg ion s o f th e im ag e to de ter mi ne if th e A /D co nv er te r i s at fu ll- sc al e. A 16 -b it A/ D i s at fu ll s ca le wh en th e b ri gh te st pa rt s of th e i ma ge re ac h an i nte ns ity o f 6 55 35 . A dju st t he ap er tur e to wh er e it is j us t sli gh tl y sm a ...

  • Princeton 4411-0106 - page 49

    Chapter 5 Operation 49 49 6. The spectrograph h as an entrance slit shutter that is being contro lled by the PIXI S via the Shutter connector. If the PI X IS has an internal shutte r, DO NOT USE the Shutter con nector to drive a spectrograph en trance slit shutter. I f bot h the cam era and the spectrograph hav e shutters, the ent rance slit shutte ...

  • Princeton 4411-0106 - page 50

    50 PIXIS Sy stem Manual Version 2.C 1. After LightFiel d opens, you shou ld see icons repres enting your cam era a nd the spectrograph in the Available Devices area. I n the figure above, the cam er a is a PIXI S:400BR eX celon ® and the spectrog r aph is an SP - 2356. 2. Drag the icons in to the Experi ment Devices area. Figure 18 . Experiment D ...

  • Princeton 4411-0106 - page 51

    Chapter 5 Operation 51 51 Confirming the Setup 1. Turn on the light source at t he spectrograph e ntrance slit. 2. Click on Run to beg i n previewing th e data. Depend ing on the display se ttings, you should see ei ther a spectral b and (image) or a graph. Background noi se will decrease as the camera cool s to its default tem per ature. 3. Turn o ...

  • Princeton 4411-0106 - page 52

    52 PIXIS Sy stem Manual Version 2.C Focusing The detector m ounting hardware p rovides two degre es of freedom : focus and rotation . In this contex t, focus mean s to physically m o ve the detector back and forth through the focal plane of the spectrograph. The appr oac h taken is to slowly m o ve the detecto r in and out of focus and ad justing f ...

  • Princeton 4411-0106 - page 53

    Chapter 5 Operation 53 53 6. Make sure that the spectroscopy-m ount adapter moves freely at the spectrograph. 7. Se lect Align Sp ectrometer… from the Experiment Options menu. Rev iew the displayed info r mation and then cl ick on the Beg in button. Typica lly, this feature creates three 1-row high ROI s (one near the top of the array, one i n th ...

  • Princeton 4411-0106 - page 54

    54 PIXIS Sy stem Manual Version 2.C 9. Next adjust the rotation. You can do th i s by rotating the cam er a while watching a live display of th e line (you m a y need to loosen two setscrews securing the spectrograph adapte r). Click on the peak y ou want to monitor during the rotational alignm ent. This positions the larg e cursor to provide a ver ...

  • Princeton 4411-0106 - page 55

    Chapter 5 Operation 55 55 IsoPlane SCT-320 Spec trograph Because the PI XIS is mounted directly to the m ounti ng plate on the I soPl ane, focusing and alignm ent is different from the way that focusing and alig nment are perform ed for an Acton Series spec t rograph. The following info rmation assum es that you are fam iliar with the locations of ...

  • Princeton 4411-0106 - page 56

    56 PIXIS Sy stem Manual Version 2.C Exposure and Signal Introduction The following topics address f actors that can a ffect the signal acquired on the CCD array. These factors incl ude array arch itecture, exposur e time, CC D temperature, dark charge, and saturation. CCD Array Architecture Charge coupled d evices (CC Ds) can be roug hly thought of ...

  • Princeton 4411-0106 - page 57

    Chapter 5 Operation 57 57 Continuous Exposure (No Shuttering) For full-frame im aging CCDs, the standard PI XIS camera for imaging i s equipped with an integral shutt er. However, in asmuch as it is possible to order the camera wi thout a shutter, the follow ing general d i scussion of uns huttered operat ion is provided. Slow scan scientifi c came ...

  • Princeton 4411-0106 - page 58

    58 PIXIS Sy stem Manual Version 2.C Once the target a rray tem perature {Temperature Setpo int} has been set, t he software controls the cam era's cooling ci rcuits to reach s et array tem per ature. On reach i ng that temperature, the control loo p locks to that tem per ature for stable and r eproducible performance. When t emperatur e lock h ...

  • Princeton 4411-0106 - page 59

    Chapter 5 Operation 59 59 For signal lev els low enough to be readout-noise lim it ed, longer exposu r e times, a nd therefore longer s ignal accum ula tion in the CCD, will improv e t he S/N ratio approximately l inearly with the length of exp osure time. Ther e is, however, a maxim um time limit for o n-chip accum ulation, determined by ei ther t ...

  • Princeton 4411-0106 - page 60

    60 PIXIS Sy stem Manual Version 2.C Full Frame Readout The upper left drawing i n Figure 25 represents a CCD after exposure but before the beg inning of readout. The capital letters repr esent diff erent amounts of charge, i ncludin g both signal and dark charge. Thi s section explains readou t at full reso lution, where every pixel i s digitized s ...

  • Princeton 4411-0106 - page 61

    Chapter 5 Operation 61 61 The readout tim e i s approxi mately g iven by: (2) where N x is the smaller dim ension of the CCD N y is the larg er dimension of the CCD t sr is the tim e needed to shift one pixe l out of the sh ift register t v is the tim e needed to digi tize a pixel t i is the tim e ne eded to shift one line into the sh ift register ...

  • Princeton 4411-0106 - page 62

    62 PIXIS Sy stem Manual Version 2.C pixels, the binning of large section s may result in s aturation and “b l ooming ”, or spilling of charge back in to the im age area. Figure 26 shows an example of 2  2 bi nning. Each pix el of the im age displayed by the software represen t s 4 pixels of th e CCD array. R ectangular bins of any size are p ...

  • Princeton 4411-0106 - page 63

    Chapter 5 Operation 63 63 Figure 27 . Binning a nd Array Orientation Note: You can e asily switch between t hese orienta tions by rotat i ng the cam er a 90° and changing the binn i ng param et ers in the applicat ion software. Output Amplifier {Quality} Selection The output am pl ifier amplifies the collected charge from t he output node and outp ...

  • Princeton 4411-0106 - page 64

    64 PIXIS Sy stem Manual Version 2.C Controller Gain Controller gain (a func tion of the pr eamplifier) is software-selectable a nd is used to change the rela tionship betw een the number of el ectrons acqui red on the CCD and the Analog- to -Digital Units (A DUs or counts) generated. Selecting the amount of g ain is done on the Acq uisition|Experim ...

  • Princeton 4411-0106 - page 65

    Chapter 5 Operation 65 65 Digitization (Rate) Introduction After gain has be en applied to the s i gnal, the Ana log- to -D igital Converter (AD C) converts that analog i nformation (cont inuous amplitud es ) into a dig ital data (quan t ified, discrete steps) that can be read, d i splayed, and stored by t he application sof t ware. The number of b ...

  • Princeton 4411-0106 - page 66

    66 PIXIS Sy stem Manual Version 2.C This page intentionally left blank. ...

  • Princeton 4411-0106 - page 67

    67 Chapter 6 Advanced Topics Introduction Pr e vi o us c h ap t er s h a ve d is c us s ed s e tt i n g up t h e h ar dw ar e an d t he s of t war e fo r b as i c op e ra ti o n . T his c ha pt e r d i sc us s es to pi c s a ss o ci a te d wi t h e x pe ri me n t s yn c hr on i za t io n . Sy n c hr on i za ti o n is se t u p o n t h e E x pe r ime ...

  • Princeton 4411-0106 - page 68

    68 PIXIS Sy stem Manual Version 2.C Timing Modes Overview The basic PIXI S timing modes are Free Run {No Resp onse}, External Sy nc {Readout Per Trigg er}, and External Sync {R eadout Per Trigg er } with Continuous Clea ns {Clean Until Trigg er }. These timing m odes are combined wi th the Shutter opt ions to prov i de the widest variety of t iming ...

  • Princeton 4411-0106 - page 69

    Chapter 6 Advanced Topic s 69 69 Free Run {No Response} In the Free Run {No R esponse} m ode t he camera does not synchronize with the experiment in any way. The shutter opens as soon as the prev ious readout is complete, and remains open for t he exposure tim e, t exp . Any External Sync sig nals are ig nored. This mode is useful for expe riments ...

  • Princeton 4411-0106 - page 70

    70 PIXIS Sy stem Manual Version 2.C External synchron ization depends on an edge trigger (negativ e- or positive-going) w hich must be supplied to the EXT SYNC connec t or on the back of the cam era. The type of edge m ust be identified in the applicat ion software to e nsur e that the shutter opening is initiated by the c orrect edge (in WinX, thi ...

  • Princeton 4411-0106 - page 71

    Chapter 6 Advanced Topic s 71 71 The PreOpen {Open B efore Trigg er } mode is useful in cases whe re an External Sync pulse cannot be pr ovided 8 ms or ~ 20 ms (the length of time the 25 m m or 45 mm mechanical shu tter takes to open) before the ac t ual signal oc curs. Its m ai n drawback i s that the CCD is exposed to any ambient light while the ...

  • Princeton 4411-0106 - page 72

    72 PIXIS Sy stem Manual Version 2.C Figure 32 . Continuous Clean s {Clean Un til Trigger} Flo wchart Once the Extern al Sync pulse i s received, clean i ng of the array stops as soon as the current row is sh ifted, and fram e col lection beg i ns. With N ormal Shutter {Normal} operation the shut ter is opened for the s et exposure tim e. W ith PreO ...

  • Princeton 4411-0106 - page 73

    Chapter 6 Advanced Topic s 73 73 Figure 33 . WinX Continu ous Cleans Timing Diagra m Figure 34 . LightField Clean Until Trigger (CUT) Timin g Diagram EXT SYNC Trigger Input The sele cte d Timi ng Mod e { Trigg er Re spo nse} deter m ine s h ow t he cam era w ill res pon d to an E xte rn al Sy nc p ulse tha t is inp ut at the E XT SYN C co nne ctor ...

  • Princeton 4411-0106 - page 74

    74 PIXIS Sy stem Manual Version 2.C Fast and Safe Modes Introduction The PIXIS has been d esigned to allow the grea test possib le flexibility when synchronizing da ta collection with an experim ent. The fundamental diffe rence between the Fast and Safe m odes is how often the acquisi tion start and a cquisition stop com mands are sent by the com p ...

  • Princeton 4411-0106 - page 75

    Chapter 6 Advanced Topic s 75 75 Figure 36 . Chart of S afe and Fast Mod e Operation ...

  • Princeton 4411-0106 - page 76

    76 PIXIS Sy stem Manual Version 2.C LOGIC OUT Control The TTL- compatible logic lev el output (0 to +3.3 V) from the LOGIC OUT connector on the rear pane l can be used to m onit or cam era status and con t rol externa l devices. By def ault , t he l ogi c o ut put leve l is h igh whil e t he a cti on is occur rin g. The tim ing of the level changes ...

  • Princeton 4411-0106 - page 77

    Chapter 6 Advanced Topic s 77 77 Kinetics Mode In the past, Kinetics Mode was a purchased option fo r WinView/32. Kinet ics Mode is now included in the standard Li ghtField and WinX applications. Introduction Kinetics m ode uses the CCD to expose and store a lim i ted number of images in rapid succession. The t ime it takes to shift each line (or r ...

  • Princeton 4411-0106 - page 78

    78 PIXIS Sy stem Manual Version 2.C Kinetic Timing Modes and Shutter Control Kinetics m ode operates wit h three timing modes: Free R un {No Response}, Single Trigger {Readou t Per Trigger}, and Mu ltiple Trigg er {Shift Per Trigg er} . Fre e r un { No Re spo nse} mod e is use d for ex perim ents that do n ot requ ire an y s yn chron izati on with ...

  • Princeton 4411-0106 - page 79

    Chapter 6 Advanced Topic s 79 79 Wi nd ow S iz e. Integrate sig nal s (SHUTTER {Shut ter Open}) or Rea dout signals (N OT SCAN {Not Reading Out}) are prov ided at the LOGIC OUT connector fo r timing measurem ents. Ex am pl e: Re fer ri ng t o t he r ead ou t sh ow n in Figure 38, th ere a re 6 pi xe ls pe rp end ic ul ar t o th e shi ft r eg is ter ...

  • Princeton 4411-0106 - page 80

    80 PIXIS Sy stem Manual Version 2.C In m ultiple trigger mode, the shutter i s opened when A cquire or Focus {Run} is cl i cked and each “exposure - shi ft” cycle in the acquisition is trigg ered independently by a pul se ap plied at the EXT SY NC connector. This mode is u seful when e ach subfram e needs to be synchronized wi t h a puls ed ext ...

  • Princeton 4411-0106 - page 81

    Chapter 6 Advanced Topic s 81 81 Software Settings Princeton I nstruments does not en courage users to chang e these parameter set tings. For most application s, the default sett ings will giv e the best result s. We strongly advise contacting the fac tory for guidan ce before custom i zing the chip definit ion. In W inX , i f Cust om Ch ip h as be ...

  • Princeton 4411-0106 - page 82

    82 PIXIS Sy stem Manual Version 2.C Custom Timing Notes: 1. This mode is standa rd with LightFie ld for full fram e CCD cam eras. 2. This option is ful l y supported by WinX Version 2.5. 18.1 (and higher). 3. This option is no t supported by WinX for 5 MHz systems.. In LightField, Cus t om Timing is access ed via the Custom Sen sor button on th e S ...

  • Princeton 4411-0106 - page 83

    83 Chapter 7 Troubleshooting Do not attach or r emov e any cables while th e camera system i s powered on. Introduction The following issues have c orresponding troubl es hooti ng sections in this chap t er. Acquisition Sta rted but View er Contents Do Not Up date Page 84 Baseline Signal Su ddenly Changes Page 84 Camera Stops Work ing Page 84 Camer ...

  • Princeton 4411-0106 - page 84

    84 PIXIS Sy stem Manual Version 2.C Acquisition Started but Viewer Contents Do Not Update In LightField, liv e da ta is norm all y displayed in the Ex peri ment wo r kspace viewe r as it is being acquired (P review or Acquire mode). I f t he viewer is no t being updated a nd acquisition is oc curring, check to see if there is a f ilenam e in the to ...

  • Princeton 4411-0106 - page 85

    Chapter 7 Troubleshoot ing 85 85 Camera1 (or similar name) in Camera Name field Figure 51 . Camera 1 in Camera Name Field When the Cam era Detection Wiz ard installs a n ew cam era, the camera is autom ati cally named “Cam er a#” (where # = 1, 2 , or 3.., dependi ng on the num ber of cam eras detected) This nam e will appear in the Hard ware Se ...

  • Princeton 4411-0106 - page 86

    86 PIXIS Sy stem Manual Version 2.C Controller Is Not Responding If this messag e pops up when y ou click on OK after selecting the "I nt erface Ty pe" during Ha rdware Setup (under t he WinX Setup m enu), the system has not been ab le to communicate w ith the cam era. Check to see i f camera has be en turned ON and if the USB 2.0 interfa ...

  • Princeton 4411-0106 - page 87

    Chapter 7 Troubleshoot ing 87 87 Cooling Troubleshooting Temperature Lock Cannot be Achieved or Maintained. Possible causes for not bein g able to achiev e or maintain lock could include:  Ambient tem per ature greater than + 23°C. This condition affec t s TE-cooled cameras. If am bient is greater than +23° C, you will need to cool the camera ...

  • Princeton 4411-0106 - page 88

    88 PIXIS Sy stem Manual Version 2.C Gradual Deterioration of Cooling Capability While unlikely w ith the PIXI S camera (guaranteed p ermanent v acuum for the lif e of the camera), if you se e a gradual dete rioration of the cooli ng capability, there m ay be a gradual deteriorat i on of the camera’s vacuum . This can affect temperature pe rforman ...

  • Princeton 4411-0106 - page 89

    Chapter 7 Troubleshoot ing 89 89 Data Overrun Has Occurred message Because of mem ory constraints and the way that USB transfers data, a "Da t a overrun has occurred" m essage may be displayed during data acquisition. I f t his messag e is display ed, take one or m or e of the follow ing actions: 1. Minimiz e the number of prog r ams runn ...

  • Princeton 4411-0106 - page 90

    90 PIXIS Sy stem Manual Version 2.C  C an cel t he lo ad . Ca nc el lin g a lo ad m ean s tha t the l ast u sed ex pe rim en t w ill n ot be lo ad ed a ut om ati ca lly wh en Lig htF ie ld op en s. Ho wev er , y ou c an lo ad t he ex pe rim ent af te r al l th e d ev ic es ar e av ail ab le, y ou c an s ta rt a n ew ex pe ri m en t d es ign , o ...

  • Princeton 4411-0106 - page 91

    Chapter 7 Troubleshoot ing 91 91 Program Error message Figure 56 . Program E rror dialog This dialog m a y appear if you hav e t ried to acqu ire a test im age, acquire data, o r run in focusing m ode a nd the DMA buffer size is too small. To correct the p roblem: 1. Click on OK . 2. Reboot the WinX app l ication. 3. Note the array size (on the Set ...

  • Princeton 4411-0106 - page 92

    92 PIXIS Sy stem Manual Version 2.C Serial violations have occurred. C heck interface cable. Figure 57 . Serial Vio lations Have Occurred dialog This error m essage dialog will appe ar if you try to acquire an image or focus the cam era and either (or both ) of the follow i ng conditions exists:  The camera syst em is not turned ON .  There i ...

  • Princeton 4411-0106 - page 93

    93 Appendix A Basic Specifications Note: This appendix pr ovides som e of the basic sp ecifications of a PI X IS sy st em. If the information you a r e lookin g for is not here, i t may be av ai lable in Appendix B, "Outline Drawings" or on the appropriate dat a sheet. Data she ets can be dow nloaded from t he Princeton I nstruments webs ...

  • Princeton 4411-0106 - page 94

    94 PIXIS Sy stem Manual Version 2.C Shutter Typically, PI X IS cam eras for imaging applicat ions are shipp ed with an internal shutter.  P IX IS: 51 2/1 02 4 : I nt er na l, win do wl es s, 1 in (2 5 m m) ap ert ur e, 8 ms o pen t ime , 8 ms cl os e t im e  P IX IS: 20 48 : I nte rn al, w in dow le ss, 1 .8 in ( 45 mm ) ap ert ure , ~ 2 0 ms ...

  • Princeton 4411-0106 - page 95

    Appendix A Basic Specif ications 95 95 USB 2.0 (USB B Female): Data link to computer via U SB cable inserted at this connector. Cab le length of 5 meters is standard. Other lengths m ay be available. Contact Custom er Support for m or e inform ation. USB A/B cable supplied w i th system. Power (DIN): 12 VDC ( 6.6A max) input from pow er supply. Pin ...

  • Princeton 4411-0106 - page 96

    96 PIXIS Sy stem Manual Version 2.C C o ol CU BE II C i r cu la t or w i th P IX IS -c om pa ti b le H os es (PN 7 56 7- 0002) Closed loop system Hoses: CoolCUBE II an d PIXIS-Compatible 3/8" I D, with no-drip quick disconn ect s at the circulator en ds and 1/4” CPC quick disconnects a t the camera ends. Coolant: 50:50 ethy l ene gly col and ...

  • Princeton 4411-0106 - page 97

    97 Appendix B Outline Drawings NOTE: Dimensions are in inche s [mm]. PIXIS Camera: C-mount (Air-Cooled) Figure 58 . Adjustab le C-Mount: In ternal Shutter (Air-co oled) ...

  • Princeton 4411-0106 - page 98

    98 PIXIS Sy stem Manual Version 2.C Figure 59 . Fixed C-Mou nt: Internal Shutter (Air-cooled) ...

  • Princeton 4411-0106 - page 99

    Appendix B Outline Drawings 99 99 PIXIS Camera: C-mount (Liquid-Cooled) Figure 60 . Adjustab le C-Mount: In ternal Shutter (Liquid -cooled) ...

  • Princeton 4411-0106 - page 100

    100 PIXIS Sy stem Manual Version 2.C Figure 61 . Fixed C-Mou nt: Internal Shutter (Liquid -coo led) ...

  • Princeton 4411-0106 - page 101

    Appendix B Outline Drawings 101 101 PIXIS Camera: F-mount (Air-Cooled) Figure 62 . F-Mou nt: Internal Shutter (Air -cooled) ...

  • Princeton 4411-0106 - page 102

    102 PIXIS Sy stem Manual Version 2.C PIXIS Camera: F-mount (Liquid-Cooled) Figure 63 . F-Mou nt: Internal Shutter (Liquid -coo led) ...

  • Princeton 4411-0106 - page 103

    Appendix B Outline Drawings 103 103 PIXIS Camera: 2048 F-mount (Air-Cooled) Figure 64 . F-Mou nt: 2048x2048 , Internal Shutter (Air-co oled) ...

  • Princeton 4411-0106 - page 104

    104 PIXIS Sy stem Manual Version 2.C PIXIS Camera: 2048 F-mount (Liquid-Cooled) Figure 65 . F-Mou nt: 2048x2048, Interna l Shutter (Liquid -cooled ) ...

  • Princeton 4411-0106 - page 105

    Appendix B Outline Drawings 105 105 PIXIS Camera: Spectroscopy mount (Air- Cooled) Figure 66 . Spec troscopy-Mount: No In ternal Shutter, 3.60 bolt circle (Ai r -cooled) ...

  • Princeton 4411-0106 - page 106

    106 PIXIS Sy stem Manual Version 2.C PIXIS Camera: Spectroscopy mount (Liquid-Cooled) Figure 67 . Spec troscopy-Mount: No In ternal Shutter, 3.60 bolt circle (L iquid -co oled) ...

  • Princeton 4411-0106 - page 107

    Appendix B Outline Drawings 107 107 Figure 68 . Spectrosco py-Mount: In ternal Shutter (3.60" and 3.8 8" bolt circles) (Air -coo led) ...

  • Princeton 4411-0106 - page 108

    108 PIXIS Sy stem Manual Version 2.C CoolCUBE II Circulator Figure 69 . CoolCUBE II Circulator ...

  • Princeton 4411-0106 - page 109

    109 Appendix C Adapter Adjustment and Focusing Procedures Adjustable C-Mount Adapter PIXI S cameras are now available w i th an adjustable C- mount adapter. The camera is adjusted at the fa ctory for s t andard C-mount focusing distance. How ever, you m ay want to adjust the focus ing distance for y our application. Tools Required  Spanner (supp ...

  • Princeton 4411-0106 - page 110

    110 PIXIS Sy stem Manual Version 2.C F-Mount Adapter Focusing Procedure Note: This proce dure sets the fo cus for the F-m ount adapt er, not the lens. Once set, it should not need to b e disturbed ag ain. 1. The lens should be m ounted to the camera as desc ribed in Chapter 4. 2. The F-m ount adapter is in two sec tions: the adapte r body (into wh ...

  • Princeton 4411-0106 - page 111

    Appendix C Adapter Adjust ment and F ocusing Procedures 111 111 Lens Focusing Procedure Except for the lens m ount focus procedure th at applies to F-mount lenses as descri bed above, there is no difference betw een focusing considerations fo r an F-mount lens and a C-mount lens. Sim pl y use the focus i ng ring on the lens to pr oduce the sharp es ...

  • Princeton 4411-0106 - page 112

    112 PIXIS Sy stem Manual Version 2.C This page intentionally left blank. ...

  • Princeton 4411-0106 - page 113

    113 Appendix D Spectrograph Adapters Princeton I nstruments offer s a variety of spec tro graph adapters for PI X IS system s . T he mounting instruc tions for these ada pters are o rganized by spectrograph model, detecto r type, and adap ter kit number. The table below cros s-references these item s with the page number for the appr opriate ins tr ...

  • Princeton 4411-0106 - page 114

    114 PIXIS Sy stem Manual Version 2.C Acton Series Spectrograph (PIXIS with Flange) Qty P/N Description 1. 3 2826-0120 Screw, 10-32  1 / 2, Hex Head, St ainless Steel Assembly Instruct i ons 1. Make sure that the shipping cover has been rem oved from the detector po rt on the spectrograph. 2. If the spacer pla te has been rem oved, reinstall it o ...

  • Princeton 4411-0106 - page 115

    Appendix D Spectrograph Adapters 115 115 Acton Series Spectrograph (PIXIS with 3.60/3.88 Bolt Circles) Qty P/N Description 1. 3 2826-0127 Screw, 10-32  1/4, Bu t ton H ead Allen Hex, Stain l ess Steel Assembly Instruct i ons 1. Make sure that the shipping cover has been rem oved from the detector po rt on the spectrograph. 2. Loosen the setsc re ...

  • Princeton 4411-0106 - page 116

    116 PIXIS Sy stem Manual Version 2.C Acton Series Spectrograph (PIXIS with C-Mount) Qty P/N Description 1. 1 8401-071-01 Adapter Plate 2. 1 8401-071-02 Threaded C- Mount Adapter 3. 3 2826-0127 Screw, 10-32  1/4, Bu t ton H ead Allen Hex, Stain l ess Steel Assembly Instruct i ons 1. Make sure that the shipping cover has been rem oved from the det ...

  • Princeton 4411-0106 - page 117

    Appendix D Spectrograph Adapters 117 117 Acton SP-2350/SP-2550 Adjustable C- to Spectroscopy-Mount Adapter (Adapter Kit 7050 - 0104) Qty P/N Description 1. 1 Adapter Plate 2. 1 2518-1284 1.25” -32 Threaded I nsert Assembly Instruct i ons 1. Make sure that the shipping cover has been rem oved from the detector po rt on the spectrograph. 2. Place t ...

  • Princeton 4411-0106 - page 118

    118 PIXIS Sy stem Manual Version 2.C Acton SP-2150/SP-2750 Adjustable C- to Spectroscopy-Mount Adapter (Adapter Kit 7050 - 0107) Qty P/N Description 1. 1 Adapter Plate 2. 1 2518-1284 1.25” - 32 Threaded Insert Assembly Instruct i ons 1. Make sure that the shipping cover has been rem oved from the detector po rt on the spectrograph. 2. Place the f ...

  • Princeton 4411-0106 - page 119

    Appendix D Spectrograph Adapters 119 119 IsoPlane SCT-320 (PIXIS with Flange) Qty P/N Description 1. 3 2826-0120 Screw, 10-32  1 / 2, Hex Head, St ainless Steel Assembly Instruct i ons 1. Make sure that the shipping cover has been rem oved from the detector m ount ing plate on the IsoPlan e. 2. Leaving 1/4" of t hread exp osed, screw the th ...

  • Princeton 4411-0106 - page 120

    120 PIXIS Sy stem Manual Version 2.C This page intentionally left blank. ...

  • Princeton 4411-0106 - page 121

    121 Appendix E C ro ss- Re fe ren cin g o f W in X a nd L ig htF ie ld T er ms WinX- to -LightField WinX LightField Active Rows Pa rallel to Shi ft Register Active Height Active Shift Reg i ster Colum ns Active Width ADC Rate Speed ADC Resolution Bit Depth Continuous Clean s Clean Until Trigger Controller Gain Analog Gain Custom Chip Custom Sensor ...

  • Princeton 4411-0106 - page 122

    122 PIXIS Sy stem Manual Version 2.C WinX LightField Minimum Block Size Final Section Heig ht Multiple Trigg er (Kinetics) Shift Per Trig ger (Kinetics) Normal Shutter Normal (Shutter) Number of Block s Final Section Coun t Number of Cleans Number of Clean Cy cles Number of Strips per Clean Clean Cycle Heig ht Post-Dummy Rows Parallel to Shift Regi ...

  • Princeton 4411-0106 - page 123

    Appendix E C ro ss- Re fe ren ci ng o f W in X an d Li gh tF ie ld T erm s 123 123 LightField- to -WinX LightField WinX Active Area: Bottom Margin Post-Dummy Rows Parallel to Shift Register Active Area: Lef t Margin Pre-Dummy Shif t Register Colum ns Active Area: Rig ht Margin Post-Dummy Shif t Register Colum ns Active Area: Top Ma r gin F.T. Dumm ...

  • Princeton 4411-0106 - page 124

    124 PIXIS Sy stem Manual Version 2.C LightField WinX Output Signal: N ot Reading Out Logic Out: Not Sc an Output Signal: Shu t ter Open Logic Out: Shut ter Preview Focus Quality Readout Port Readout Per Trigg er External Sync Readout Per Trigg er (Kinetics) Single Trigg er (Kinetics) Sensor Readout Reg ion expander fun ctions Easy Bin Shift Per Tri ...

  • Princeton 4411-0106 - page 125

    125 Declaration of Conformity This section of the PIXI S system manual contains the Decla ration(s) of Conform it y for PIXI S systems. ...

  • Princeton 4411-0106 - page 126

    126 PIXIS Sy stem Manual Version 2.C ...

  • Princeton 4411-0106 - page 127

    Declaration of Conformity 127 127 ...

  • Princeton 4411-0106 - page 128

    128 PIXIS Sy stem Manual Version 2.C This page intentionally left blank. ...

  • Princeton 4411-0106 - page 129

    129 Warranty & Service Limited Warranty Princeton I nstruments, a div i sion of Roper Sc ientific, Inc. ("Pr inceton Instrum ents", "us", "we", "our") mak es t he following l imited warrant ies. These lim i ted warrantie s extend to the original purch aser ("Yo u", "you") only and no o ...

  • Princeton 4411-0106 - page 130

    130 PIXIS Sy stem Manual Version 2.C Sealed Chamber Integrity Limited 12 Month Warranty Princeton I nstruments warrants the sealed cham ber integrity of all our produ cts for a period of twelv e (12) months afte r shipment. I f, at anytime within tw el ve (12) m ont hs from the date of d elivery, the detector should exper ience a sealed c hamber fa ...

  • Princeton 4411-0106 - page 131

    Warranty & Service 131 131 Owner's Manual and Troubleshooting You should read the owner’s m anual t horoughly befo re operating this pro duct. I n the unlikely event that you should en counter difficu lty operating this p r oduct, the own er ’s manual should be consulted befo re contacting the P rinceton I nstruments technica l support ...

  • Princeton 4411-0106 - page 132

    132 PIXIS Sy stem Manual Version 2.C 10. Al l w ar ra nt ie s im pl ie d b y sta te la w o r no n-U . S. la ws , in clu din g th e im pl ie d w ar ra nt ie s of m erc han ta bil ity an d fit nes s for a pa rti cu lar p urp os e, a re ex pre ssl y li m it ed t o t he d ur at io n of th e li m it ed w ar ra nt ie s set f or th ab ov e. W ith t he ex ...

  • Princeton 4411-0106 - page 133

    133 Index A-B A/D converters 65, 95 AC power requirements 25 Ac ces so ri es, al ign men t of 44, 54 Acquisition started, vie wer conten ts do not update 84 Adapter instructions 114, 115, 116 Ac ton Se ri es s pec tr ogra phs 11 4, 115 , 11 6, 117 , 1 18 ad jus ta ble C- to sp ect ros copy -m ount 7050 - 0104 117 7050 - 0107 118 Is oPl ane SC T- 32 ...

  • Princeton 4411-0106 - page 134

    134 PIXI S System Manual V ersion 2.C Connectors EX T S YNC 14 ex te rnal sh utt er 14, 94 L EMO 14 LO GIC OU T 14 pow er 1 4, 95 US B 14, 95 Connectors LOGIC OUT 94 Contact infor mation 132 Continuous Cleans 71 Controller gain 6 3, 64 CoolCUBE II 18 h os e c onn ect ion s 27 ou tl ine d raw ing 108 s pe ci f ic at io ns 96 Cooling 15 co ol an t mi ...

  • Princeton 4411-0106 - page 135

    Index 135 135 L-N LEMO connector 14 Le nse s, m oun ting 31 LightField 17 LOGIC 0 output level 76, 94 LOGIC 1 output level 76, 94 Logic Out levels Alw ays Hig h 76 Alw ays Low 76 Bu sy 76 LO GIC 0 76 , 94 LO GIC 1 76 , 94 No t R ead ing Ou t 76 NO T R EAD Y 76 , 9 4 NO T S CAN 76 , 94 S HU TTER 76 , 9 4 Sh utt er Op en 76 Low noise amplifier 63 Mai ...

  • Princeton 4411-0106 - page 136

    136 PIXI S System Manual V ersion 2.C T Technical support 132 Temperature co nt ro l p rob lem s 87 op era tin g 95 s pe cif ica ti ons 95 th ermal cu tout sw itch 87 Temperature control 57 ef fe ct of va cuum d ete rio rat ion 88 Temperature lock 58 The rm al c utou t sw itch 8 7 Timing control 74 Timing modes 68 Trigger modes m ulti pl e t rigg e ...

Manufacturer Princeton Category Digital Camera

Documents that we receive from a manufacturer of a Princeton 4411-0106 can be divided into several groups. They are, among others:
- Princeton technical drawings
- 4411-0106 manuals
- Princeton product data sheets
- information booklets
- or energy labels Princeton 4411-0106
All of them are important, but the most important information from the point of view of use of the device are in the user manual Princeton 4411-0106.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Princeton 4411-0106, service manual, brief instructions and user manuals Princeton 4411-0106. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Princeton 4411-0106.

Similar manuals

A complete manual for the device Princeton 4411-0106, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Princeton 4411-0106 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Princeton 4411-0106.

A complete Princeton manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Princeton 4411-0106 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Princeton 4411-0106, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Princeton 4411-0106, that we can find in the current document
3. Tips how to use the basic functions of the device Princeton 4411-0106 - which should help us in our first steps of using Princeton 4411-0106
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Princeton 4411-0106
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Princeton 4411-0106 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Princeton 4411-0106?

Use the form below

If you did not solve your problem by using a manual Princeton 4411-0106, ask a question using the form below. If a user had a similar problem with Princeton 4411-0106 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)