R DO NOT DISCARD THIS MANUAL CAUTION • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. HOT SURF ACES! Glass and other surfaces are hot during operation AND cool down. W ARNING Hot glass will cause burns. • Do not touch glass until it is cooled • NEVER allow childre ...
-
Quadra-Fire 3100-I - page 2
3100-I ACT WOOD INSERT Page 2 September 1, 2008 R 250-6381D and Welcome to the Quadra-Fire Family ! H earth & Home T echnologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality , durability , and performance. This commitment begins with our research of the market, ...
-
Quadra-Fire 3100-I - page 3
Page 3 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D SAFETY & OVER VIEW OF APPLIANCE Serial Number /Listing Label Location ------------------ 2 Dimensions ----------------------------------------------------- 4 Minimum Clearances to Combustibles ------------------ 5 Installation Recommendations ---------------------------- 6 Listings & ...
-
Quadra-Fire 3100-I - page 4
3100-I ACT WOOD INSERT Page 4 September 1, 2008 R 250-6381D INSERT DIMENSIONS T OP VIEW SIDE VIEW FRONT VIEW A B C L 27-7/16" (697mm) 14-1/8" (359mm) 38-7/8" (987mm) 12-3/16" (310mm) 8-5/8" (219mm) 5-3/8" (137mm) 22-7/16" (570mm) 23-1/8" (587mm) 21-1/2" (546mm) 20-3/8" (518mm) 26-1/4" (667mm) 7 ...
-
Quadra-Fire 3100-I - page 5
Page 5 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Hearth Extension A B C D F E Insert SideW all Maximum Mantel Depth - 10" (254mm) Fascia or T rim Mantel Thermal Protection USA & Canada USA CANADA A Sidewall to Stove 16" 16" (406mm) B Mantel Clearances *No Mantel Shield 33" 34" (864mm) with 5" Mantel Defle ...
-
Quadra-Fire 3100-I - page 6
3100-I ACT WOOD INSERT Page 6 September 1, 2008 R 250-6381D A VOID FIRE: T o ensure that insulation or any other combustible material does not contact the chimney , a chimney inside the house must have at least 2 inches (51mm) of air space clearance around t he chimney . A chimney outside the house must have at least 1 inch (25mm) clearance to the ...
-
Quadra-Fire 3100-I - page 7
Page 7 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D IF INST ALLING THIS MODEL TO A MASONR Y CHIMNEY , AL W A YS BE SURE THE CHIMNEY IS IN GOOD CONDITION AND THA T IT MEETS THE MINIMUM ST ANDARDS OF THE NA TIONAL FIRE PROTECTION ASSOCIA TION (NFP A) ST ANDARD 21 1. A F ACTOR Y BUIL T CHIMNEY MUST BE 6 INCH (152mm) UL 103 HT AND ULC S629. THIS ...
-
Quadra-Fire 3100-I - page 8
3100-I ACT WOOD INSERT Page 8 September 1, 2008 R 250-6381D Floor Ceiling Caulk Floor (second Story) Non-Combustible Firestopping Material Minimum 1 inch (25mm) clearance from exterior chimney to sheathing Firestopping 2 inch (51mm ) A chimney must be the required height above the roof or other obstruction for safety and for proper draft oper - ati ...
-
Quadra-Fire 3100-I - page 9
Page 9 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D MASONR Y FIREPLACE USING DIRECT -CONNECT METHOD Refer to: Clearances to Combustibles on page 5, Canadian Installation requirements on page 1 1, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 14. Figure 9A - Installation Into Masonry Fireplace Direct Connect ...
-
Quadra-Fire 3100-I - page 10
3100-I ACT WOOD INSERT Page 10 September 1, 2008 R 250-6381D The following modications of factory built replaces are permissible: 1) removal of damper; 2) removal of smoke shelf or bafe; 3) removal of ember catches; 4) removal of re grate; 5) removal of viewing screen/curtain; and, 6) removal of doors. NOTE: Installation into replace ...
-
Quadra-Fire 3100-I - page 11
Page 1 1 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D INST ALLA TION IN CANADA MASONR Y and HEA T -CIRCULA TING (INST ALLA TIONS INTO F ACTORY -BUIL T FIREPLACES ARE PROHIBITED IN CANADA) Whether installed in a masonry or heat-circulating replace, this replace insert must be installed with a continuous chim- ney liner of 6” (152mm) d ...
-
Quadra-Fire 3100-I - page 12
3100-I ACT WOOD INSERT Page 12 September 1, 2008 R 250-6381D Vi ew of "L" Bracket installed Kit Includes: ( 2) Side Panels, left & right; (1) Panel T op & Fastener package; (2) Side T rim, left & right; (1) T rim T op & Fastener package. T ools Needed: Powered Phillips head screw driver . 1. Install the 2 side panels on th ...
-
Quadra-Fire 3100-I - page 13
Page 13 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Included in Kit: (2) Fan mounts & fan assemblies; (1) Speed Control, Power Cord/wire assembly; (1 set) Fan Connector wires, must be high temperature wire; and (1) Strain relief. T ools Needed: Large Phillips screwdriver , pliers F AN (BLOWER) INST ALLA TION INSTRUCTIONS Part No. 831-1 ...
-
Quadra-Fire 3100-I - page 14
3100-I ACT WOOD INSERT Page 14 September 1, 2008 R 250-6381D ZERO CLEARANCE ADJUST ABLE TRIM SUPPORT , 2” to 10” Part No. 841-0990, size 9” x 45” and Part No. ADJSPT -12, size 12” x 50” Included in Kit: ( 1) T rim T op, (1) T rim Front, (2) T rim Sides, Double-Sided T ape (already installed) T ools Needed: Phillips Head Screwdriver , Sh ...
-
Quadra-Fire 3100-I - page 15
Page 15 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D WOOD SELECTION AND STORAGE Burn only dry seasoned wood. Dry , well-seasoned wood will not only minimize the chance of creosote formation but will give you the most efcient heat output. Even dry wood contains at least 15% moisture by weight and should be burned hot enough to keep the chi ...
-
Quadra-Fire 3100-I - page 16
3100-I ACT WOOD INSERT Page 16 September 1, 2008 R 250-6381D BURN RA TES ST ARTING FIRE : Open both controls (push in) completely . After a wood load has been burning on high for 5 to 15 minutes or longer for very large pieces, close the Start-Up Air Control (right side) by pulling it out. HIGH: Leave the Primary Air Control fully open (immediately ...
-
Quadra-Fire 3100-I - page 17
Page 17 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D AIR qUALITY AND YOUR qUADRA-FIRE INSERT In recent years there has been an increasing concern about the quality of our air . Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve this situation we at Quadra-Fire have developed cl ...
-
Quadra-Fire 3100-I - page 18
3100-I ACT WOOD INSERT Page 18 September 1, 2008 R 250-6381D MAINTENANCE CARE AND CLEANING OF PLA TED SURF ACES IMPORT ANT : Y ou must clean all the ngerprints and oils from the plated surfaces before ring the insert for the rst time. Use warm soapy water and a soft rag, glass cleaner and a paper towel, or vinegar and a paper towel to remo ...
-
Quadra-Fire 3100-I - page 19
Page 19 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D BAFFLE REMOV AL & INST ALLA TION NOTE : The bafe in the 3100-I ACT Insert is 2700° Fiber Board. Removing hardware exposed to combustion processes can be frustrating. If your reason for removing the bafe is simply to clean the chimney , you have alternatives which will save time ...
-
Quadra-Fire 3100-I - page 20
3100-I ACT WOOD INSERT Page 20 September 1, 2008 R 250-6381D EXPLODED VIEW 1 9 10 11 2 4 3 8 6 7 5 Item Description Item Description 1 T rim Ring, Louver 7 Screen, Left/Right (interchange - able) 2 Manifold T ubes, Back (3) 8 Speed Control 3 Manifold T ube, Front (1) 9 Bafe, Fiberboard 4 Spring Handle, 1/4” (2) 10 Blanket, Ceramic 5 Blower Ass ...
-
Quadra-Fire 3100-I - page 21
Page 21 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Item # Part Description Alphabetical Order SKU 9 Bafe, Fiberboard 831-1800 10 Blanket, Ceramic, 1 inch thick 832-3401 Blower Assembly , with Wire Harness 831-1 101 Blower Cord with Speed Control & Wire Harness 832-1400 5 Blower Assembly 831-1 101 Blower Replacement (1) 832-3190 1 1 ...
-
Quadra-Fire 3100-I - page 22
3100-I ACT WOOD INSERT Page 22 September 1, 2008 R 250-6381D 1 T rim Ring for Louver, Gold 430-2691 1 T rim Ring for Louver, Nickel 430-5430 Upgrade Kit to Nickel, Door UK-DRNL 14 W asher, Spacing SAE 3/8 for Door Handle 220-0010 Item # Part Description Alphabetical Order SKU ACCESSORIES 15 16 17 18 19 20 21 22 12 13 14 Item Description Part No. 12 ...
-
Quadra-Fire 3100-I - page 23
Page 23 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Date of Service Performed By Description of Service Service And Maintenance Log ...
-
Quadra-Fire 3100-I - page 24
3100-I ACT WOOD INSERT Page 24 September 1, 2008 R 250-6381D Date of Service Performed By Description of Service Service And Maintenance Log (Cont’d) ...
-
Quadra-Fire 3100-I - page 25
Page 25 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D Homeowner ’ s Notes ...
-
Quadra-Fire 3100-I - page 26
3100-I ACT WOOD INSERT Page 26 September 1, 2008 R 250-6381D W arranty Policy Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United Sta ...
-
Quadra-Fire 3100-I - page 27
Page 27 September 1, 2008 3100-I ACT WOOD INSERT R 250-638D HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identication label furnished with the ...
-
Quadra-Fire 3100-I - page 28
Page 28 September 1, 2008 250-6381D R • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instruci- tons for safe installation and operation. • Leave this manual with party responsible for use and operation. CAUTION This product may be covered by one or more of the f ...
Do you have a question concerning Quadra-Fire 3100-I?
Use the form below
If you did not solve your problem by using a manual Quadra-Fire 3100-I, ask a question using the form below. If a user had a similar problem with Quadra-Fire 3100-I it is likely that he will want to share the way to solve it.