Manual UltraViolet Devices Air Disinfection

12 pages 0.44 mb
Download

Go to site of 12

Summary
  • UltraViolet Devices Air Disinfection - page 1

    Document No. 98-1 137A1 • Revised September 2007 • © 2003-2007 Atlantic Ultraviolet Corporation ultraviolet.com 375 Marcus Boulevard • Hauppauge, NY 1 1 788 • USA 63 1 .273.0500 • Fax: 63 1 .273.077 1 e-mail: info@ultraviolet.com Extensive Product Information A vailable at: ...

  • UltraViolet Devices Air Disinfection - page 2

    2 T ABLE OF CONTENTS SAFETY W ARNINGS .....................................................................................................................................................3 SAFETY INSTRUCTIONS ............................................................................................................................................4 ...

  • UltraViolet Devices Air Disinfection - page 3

    3 SAFETY W ARNINGS • All personnel should be alerted to the potential hazards indicated by the product safety labeling on this fixture. • The following conventions are used to indicate and classify precautions in this manual and on product safety labeling. Failure to observe precautions could result in injury to people or damage to property . ! ...

  • UltraViolet Devices Air Disinfection - page 4

    4 PRODUCT APPLICA TION C ONSTRUCTION The Hygeaire ® brand fixtures are categorized as indirect type germicidal fixtures, which utilize germicidal lamp(s) with a series of louvers to direct ultraviolet rays to the upper areas of a room, thereby destroying bacteria and viruses that are carried into the ultraviolet field by convection currents or air ...

  • UltraViolet Devices Air Disinfection - page 5

    5 INST ALLA TION L OCA TION • The Hygeaire ® fixture is recommended for use in rooms with good ventilation, with a ceiling height of 9 feet or more and where occupants remain for prolonged periods. • Access to the room does not need to be controlled while the fixture is operating. • The louver panels of the Hygeaire ® fixtures protect room ...

  • UltraViolet Devices Air Disinfection - page 6

    6 INST ALLA TION I NST ALLA TION OF LIND 24-EVO Figure 1 - LIND 24-EV O Installation 1. The fixture is to be mounted on a plumb, vertical surface, at a minimum height of 6 ½ to 7 feet from the floor . Installation must be able to support approximately 16 pounds. 2. Remove thumbscrews and open fixture to expose interior lamp holders and reflectors. ...

  • UltraViolet Devices Air Disinfection - page 7

    7 I NST ALLA TION OF LIND 24-EVO-2PM Figure 2 - LIND 24-EV O-2PM Installation 1. Installation and all wiring should confirm to state and local electrical codes as well as the current National Electrical Code (NEC). Installation must be able to support approximately 32 pounds. 2. After fixture is mounted and wired, open louver panels by removing thu ...

  • UltraViolet Devices Air Disinfection - page 8

    8 MAINTENANCE The Hygeaire ® is designed to operate with a minimal amount of maintenance. Besides occasional ultraviolet measure- ments to insure that ultraviolet intensities in the treated areas remain within the allowable exposure limits and above minimum levels, a regular cycle of cleaning, the germicidal lamp and interior reflectors, should be ...

  • UltraViolet Devices Air Disinfection - page 9

    9 TROUBLESHOOTING CAUTION: Always disconnect power to the fixture, before performing any service. • IMPOR T ANT : This fixture is to be serviced ONL Y by qualified, and appropriately licensed, personnel. T able 1 - T roubleshooting ! Use personal protection equipment , such as gloves; long sleeves with no gaps between cuf fs and gloves, and ultra ...

  • UltraViolet Devices Air Disinfection - page 10

    10 REPLACEMENT P ARTS LIND 24-EVO Figure 3 - Replacement parts Model LIND 24-EV O Other replacement parts are available. Consult the Factory for specific requirements. Item No.: Description: Quantity: Part No. 1 Germicidal Ultraviolet Lamp, G24T6L 1 05-1348 Electronic V ariable Output Ballast, 120v 50/60Hz 10-0056B 2 Electronic V ariable Output Bal ...

  • UltraViolet Devices Air Disinfection - page 11

    11 REPLACEMENT P ARTS LIND 24-EVO-2PM Figure 4 - Replacement parts Model LIND 24-EV O-2PM Other replacement parts are available. Consult the Factory for specific requirements. Item No.: Description: Quantity: Part No. 1 Germicidal Ultraviolet Lamp, G24T6L 2 05-1348 Electronic V ariable Output Ballast, 120v 50/60Hz 10-0056B 2 Electronic V ariable Ou ...

  • UltraViolet Devices Air Disinfection - page 12

    12 W ARRANTY W e warrant that this product will be free from defects in material and workmanship for a period of one year from the date of shipment thereof or the product’ s total rated life, whichever first occurs. Within the warranty period we shall repair or replace such products, which are returned to us with shipping charges prepaid, and whi ...

Manufacturer UltraViolet Devices Category Air Cleaner

Documents that we receive from a manufacturer of a UltraViolet Devices Air Disinfection can be divided into several groups. They are, among others:
- UltraViolet Devices technical drawings
- Air Disinfection manuals
- UltraViolet Devices product data sheets
- information booklets
- or energy labels UltraViolet Devices Air Disinfection
All of them are important, but the most important information from the point of view of use of the device are in the user manual UltraViolet Devices Air Disinfection.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals UltraViolet Devices Air Disinfection, service manual, brief instructions and user manuals UltraViolet Devices Air Disinfection. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product UltraViolet Devices Air Disinfection.

A complete manual for the device UltraViolet Devices Air Disinfection, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use UltraViolet Devices Air Disinfection by users. Manuals are usually written by a technical writer, but in a language understandable to all users of UltraViolet Devices Air Disinfection.

A complete UltraViolet Devices manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual UltraViolet Devices Air Disinfection - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the UltraViolet Devices Air Disinfection, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the UltraViolet Devices Air Disinfection, that we can find in the current document
3. Tips how to use the basic functions of the device UltraViolet Devices Air Disinfection - which should help us in our first steps of using UltraViolet Devices Air Disinfection
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with UltraViolet Devices Air Disinfection
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of UltraViolet Devices Air Disinfection in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning UltraViolet Devices Air Disinfection?

Use the form below

If you did not solve your problem by using a manual UltraViolet Devices Air Disinfection, ask a question using the form below. If a user had a similar problem with UltraViolet Devices Air Disinfection it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)