Manual Zephyr ZMI-M90AS

20 pages 0.77 mb
Download

Go to site of 20

Summary
  • Zephyr ZMI-M90AS - page 1

    Use, Care, and Installation Guide www .zephyronline.com Model number: Serial Number: FEB09.0201 © Zephyr Corporation Milano W all ZMI-M90AS ZMI-M90AG ...

  • Zephyr ZMI-M90AS - page 2

    www .zephyronline.com ...

  • Zephyr ZMI-M90AS - page 3

    1 SAFETY NOTICE ................................................................. 2-3 LIST OF MA TERIALS ....................................................... 4 INST ALLA TION Ducting Calculation Sheet ....................................... 5 Mounting Height & Clearance ................................ 6 Ducting Options ..................... ...

  • Zephyr ZMI-M90AS - page 4

    Important Safety Notice READ AND SA VE THESE INSTRUCTIONS 2 www .zephyronline.com W ARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS F AN WITH ANY SOLID-ST A TE CONTROL DEVICE. W ARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSER VE THE FOLLOWING: a. Use this unit only in the manner intended by the man ...

  • Zephyr ZMI-M90AS - page 5

    Important Safety Notice 3 W ARNING TO REDUCE THE RISK OF FIRE, USE ONL Y MET AL DUCTWORK. CAUTION T o reduce risk of fi re and to properly exhaust air outside - Do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces or garages. OPERA TION Always leave safety grilles and fi lters in place. Without these components, operat ...

  • Zephyr ZMI-M90AS - page 6

    List of Materials 4 www .zephyronline.com (3) Wire Nuts (3) M4 x 1-1/2” (2) M4 x 1” (4) 3/16” x 8 (4) M3.5 x 8 P ARTS NOT SUPPLIED - Ducting, conduit and all installation tools - Cable connector (if required by local codes) - Duct cover extension accessory - Z1C-00MI - Recirculating kit accessory - ZRC-0040 HARDW ARE P ACKAGE CONTENTS MODELS: ...

  • Zephyr ZMI-M90AS - page 7

    5 Duct pieces To t a l Equivalent number length x used = 3- 1/ 4” x 10” Rect., straight 1 Ft. x ( ) = Ft. 8” Round, straight 1 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 90 0 elb ow 15 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 45 0 elb ow 9 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. 90 0 flat elb ow 24 Ft. x ( ) = Ft. 3- 1/ 4” x 10” Rect. wall ...

  • Zephyr ZMI-M90AS - page 8

    Installation – Mounting Height & Clearance 6 www .zephyronline.com DUCTING A minimum of 6” round duct must be used to maintain maximum air fl ow ef fi ciency . Always use rigid type metal ducts only . Flexible ducts could restrict air fl ow by up to 50%. Use calculation worksheet to compute total duct work (Page 5). AL WA YS, when possib ...

  • Zephyr ZMI-M90AS - page 9

    7 W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only . Fasten all connections with sheet metal screws and tape all joints w/ certi fi ed Silver T ...

  • Zephyr ZMI-M90AS - page 10

    8 www .zephyronline.com Installation – Hood Speci fi cations 23 15/16” min. ducted - 26 1/2” min. recirc. - 30” max. - 49” 10 1/2” elec. k/o 4” 8 1/2” 35 7/16” 14” 20 1/2” 6” Ø top of hood front of hood side of hood ...

  • Zephyr ZMI-M90AS - page 11

    9 1. Measure from range top to hood bottom and mark line A. (28” minimum from range top) . 2. Plum and mark center line. 3. Mark mounting height line B. (15-3/8” from line A) 4. Mark mounting spread from C/L. (8-7/8”) 5. Fasten (2) M4 x 1-1/2” screws into studs on line B but do not tighten all the way . Note: Wood blocking may need to be ad ...

  • Zephyr ZMI-M90AS - page 12

    10 www .zephyronline.com (blower housing) Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is ...

  • Zephyr ZMI-M90AS - page 13

    11 Lights On/Dim/Off 15 Min Delay Off Display (speed level, delay off, filter clean/change) Adjust 6 Speed Levels Blower On/Off 1. Blower On/Off By pressing the blower is switched on and off. When switched on, the blower starts up on speed level 3. 2. Speed Selection The 6 speed levels are selected by pressing to decrease and to increase speed leve ...

  • Zephyr ZMI-M90AS - page 14

    Features & Controls – Charcoal Filter Change Reminder 12 www .zephyronline.com Charcoal Filter Change Reminder (charcoal filter , if installed) When your hood is installed as a recirculating unit, it is fitted with a set of charcoal filters to purify exhaust and fumes from cooking, then re-circulates the air within the home. These charcoal fi ...

  • Zephyr ZMI-M90AS - page 15

    Features & Controls – Metal Mesh Filter Clean Reminder 13 Metal Filter Clean Reminder (metal mesh filter) Whether your hood is installed as an exhaust or purifying unit, a set if metal mesh filters are fitted by the factory , These metal mesh filters are intended to filter out residue from cooking. They need not be replaced on a regular basis ...

  • Zephyr ZMI-M90AS - page 16

    14 www .zephyronline.com SURF ACE MAINTENANCE: Clean periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent , or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser . After cleaning it is recommended that you use non-abrasive stainless steel polish/clean ...

  • Zephyr ZMI-M90AS - page 17

    Maintenance - Lights 15 of the REPLACING LIGHT BULBS CAUTION: Light bulb becomes extremely hot when turned on. DO NOT touch bulb until switched off and cooled. T ouching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. Remove by turning bulb counter clockwise. Note: Bulb does not unscrew; it turns 60 deg ...

  • Zephyr ZMI-M90AS - page 18

    16 www .zephyronline.com T roubleshooting TROUBLESHOOTING PROCEDURES FOR MILANO W ALL Issue Cause What to do After installation, the unit doesn’t work. 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s power is ON. 2. The power line and the cable locking connector is not connecting properly . 2. Check the pow ...

  • Zephyr ZMI-M90AS - page 19

    List of Parts & Accessories 17 DESCRIPTION P ART# Replacement Parts Light Bulb GU-10 50W (each) Z0B-0020 Metal Mesh Filter (each) 5020001 1 Optional Accessories Recirculating Kit ZRC-0040 Replacement Charcoal Filter Z0F-C002 Duct Cover Extension Z1C-00MI T o order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8 ...

  • Zephyr ZMI-M90AS - page 20

    1-888-880-8368 STAPLE YOUR RECEIPT HERE TO OBTAIN SERVICE UNDER WARRANTY OR FOR ANY SERVICE RELATED QUESTIONS, please call: Zephyr Corporation (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be fre ...

Manufacturer Zephyr Category Ventilation Hood

Documents that we receive from a manufacturer of a Zephyr ZMI-M90AS can be divided into several groups. They are, among others:
- Zephyr technical drawings
- ZMI-M90AS manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr ZMI-M90AS
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr ZMI-M90AS.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr ZMI-M90AS, service manual, brief instructions and user manuals Zephyr ZMI-M90AS. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr ZMI-M90AS.

Similar manuals

A complete manual for the device Zephyr ZMI-M90AS, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr ZMI-M90AS by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr ZMI-M90AS.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr ZMI-M90AS - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr ZMI-M90AS, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr ZMI-M90AS, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr ZMI-M90AS - which should help us in our first steps of using Zephyr ZMI-M90AS
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr ZMI-M90AS
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Zephyr ZMI-M90AS in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Zephyr ZMI-M90AS?

Use the form below

If you did not solve your problem by using a manual Zephyr ZMI-M90AS, ask a question using the form below. If a user had a similar problem with Zephyr ZMI-M90AS it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)