    Seri e s P 200A Updated 6/00 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual For Models: P217 P218 P219 P220 P221 P223 Contents: Installation Instructions: page 2 Pump Specifications: pages 3- 8 Parts List: page 9 Exploded View: page 10 Kits & Torque Specifications: page 11 Repair Instructions: pages 12-13 Trouble ...

  • Giant P219 - page 2

    2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc. to further reduce system pulsa- tion. Dampeners can also reduce the severity of pr ...

  • Giant P219 - page 3

    3 P217A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 1725 1.7 1.2 1.8 2.4 3.0 3000 3.0 2.1 3.1 4.2 5.2 3200 3.2 2.2 3.3 4.4 5.5 3450 3.4 2.3 3.5 4.7 5.9 Specifications Model P217A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotat ...

  • Giant P219 - page 4

    4 NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Exchange the oil fill and the oi ...

  • Giant P219 - page 5

    5 Specifications Model P219A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Excha ...

  • Giant P219 - page 6

    6 Specifications Model P220A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crank- case and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position. Excha ...

  • Giant P219 - page 7

    7 Specifications Model P221A V olume ................................................................................................... Up to 2.21 GPM Discharge Pressure ................................................................................ Up to 2500 PSI * Inlet Pressure .................................................................. ...

  • Giant P219 - page 8

    8 Specifications Model P223A V olume ................................................................................................... Up to 3.0 GPM Discharge Pressure ................................................................................ Up to 3000 PSI * Inlet Pressure ................................................................... ...

  • Giant P219 - page 9

    9 ITE M PART NO. DESCRIPTION QTY. 16A 06562 Plunger Base (P223 Only) 3 16B 08455 Plunger Pipe (Excluding P223) 3 16B 07778 Plunger Pipe (P223 Only) 3 16C 08456 Tension Screw 3 16D 07676 Copper Gasket 3 17 08442 Wrist Pin 3 18 07770 O-Ring 3 19 08356-0010 Oil Seal 3 20 08444 Seal Case (Excluding P223) 3 20 06563 Seal Case (P223 Only) 3 21 08443 O-Ri ...

  • Giant P219 - page 10

    10 Exploded View - P200A Series ...

  • Giant P219 - page 11

    11 P200A SERIES REPAIR KITS Plunger Packing Kit Part # 09164 (Excluding P223) Item # Qty. Part # Description 23 3 08477 V-Sleeve, weep 23A 3 08087 V-Sleeve, brown 24 3 07904 Pressure Ring Plunger Packing Kit Part #09525 (P223 Only) Item # Qty. Part # Description 23 6 06315 V -Sleeve 24 3 06920 Pressure Ring Oil Seal Kit Part # 09144 Item # Qty. Par ...

  • Giant P219 - page 12

    12 NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.e., the elastomers) from cutting and scoring. 1. With a 22mm socket wrench, remove the (3) discharge valve plugs and (3) inlet valve plugs (32) Inspe ...

  • Giant P219 - page 13

    13 Reassembly sequence of the P200A series pump 1) If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing. 2) Replace seal case (20) with o-rings (21) over plungers. Generously lubricate o-rings and oil seal before reassembly. Replace v-sleeve (23) over plungers (16).. 3) Generously lubricate v-sle ...

  • Giant P219 - page 14

    14 PUMP SYSTEM MALFUNCTION MALFUNCTION The Pressure and/or the Delivery Drops Water in crankcase Noisy Operation Rough/Pulsating Operation with Pressure Drop Pressure Drop at Gun Excessive Leakage High Crankcase Temperature CAUSE Worn packing seals Broken valve spring Belt slippage Worn or Damaged nozzle Fouled discharge valve Fouled inlet strainer ...

  • Giant P219 - page 15

    15 NOTES P200A DIMENSIONS (inches) ...

  • Giant P219 - page 16

    GI ANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period. If they ever fail, we will replace them free of char ...

Manufacturer Giant Category Septic System

Documents that we receive from a manufacturer of a Giant P219 can be divided into several groups. They are, among others:
- Giant technical drawings
- P219 manuals
- Giant product data sheets
- information booklets
- or energy labels Giant P219
All of them are important, but the most important information from the point of view of use of the device are in the user manual Giant P219.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Giant P219, service manual, brief instructions and user manuals Giant P219. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Giant P219.

Similar manuals

A complete manual for the device Giant P219, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Giant P219 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Giant P219.

A complete Giant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Giant P219 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Giant P219, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Giant P219, that we can find in the current document
3. Tips how to use the basic functions of the device Giant P219 - which should help us in our first steps of using Giant P219
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Giant P219
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Giant P219 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Giant P219?

Use the form below

If you did not solve your problem by using a manual Giant P219, ask a question using the form below. If a user had a similar problem with Giant P219 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)