  • Omron RX-1 - page 1

    1 English Page 2 - 10 Deutsch Seite 1 1 - 19 Nederlands Pagina 20 - 28 Français Page 29 - 37 Italiano Pagina 38 - 46 Español Página 47 - 55 Instruction Manual RX-I Fully automatic blood pressure monitor for measurement on the wrist Gebrauchsanweisung RX-I Vollautomatisches Blutdruckmeßgerät zur Messung am Handgelenk Gebruiksaanwijzing RX-I Vol ...

  • Omron RX-1 - page 2

    English 2 The OMRON RX-I is a very compact, fully automatic wrist blood pressure monitor . Operating on the oscillometric principle, it measures your blood pressure and pulse simply and quickly from the wrist. This means the monitor detects the pressure in your artery and converts the information into a digital reading. This monitor does not requir ...

  • Omron RX-1 - page 3

    English 3 Important: • RX-I Blood pressure measurements are not possible in cases of severe arteriosclerosis (hardening of the arteries). • The pulse display is not suitable for measuring the frequency of cardiac pacemakers. • Please be sure to wrap the cuff around your wrist before starting to mea- sure. Furthermore, do not inflate the cuff ...

  • Omron RX-1 - page 4

    English 4 2. Fitting the cuff 10 - 15mm Place the cuff on your left wrist with your thumb pointing up. Align the edge of the cuff as shown in the diagram. Place the wrist cuff on bare skin. Keep it clear of your clothing but do not roll up your sleeve. Hold the bottom part of the cuff as shown in the diagram and wrap it around your wrist while pull ...

  • Omron RX-1 - page 5

    English 5 When you press the ON/OFF(O/I)button, all the symbols on the display light up briefly . This serves to check the display . Then all the symbols go out and the air release sym- bol ( ) begins to flash. When the symbol ( )appears, the monitor is ready to begin measurement. Y our blood pressure is measured during inflation, so it is importan ...

  • Omron RX-1 - page 6

    English 6 3. Memory function The measured and displayed blood pressure and pulse values are auto- matically stored in the memory . The memory can store the values of up to 7 measurements. Once the memory has 7 measurement values the next reading will be stored and the oldest reading will be erased. The measured values stored in the memory will not ...

  • Omron RX-1 - page 7

    English 7 Possible faults, their causes and rectification Faults and their possible causes Incorrect measurement is indicated by E , EE or E A correct reading was not possi- ble because measurement was impaired by movement or spea- king, or owing to a very weak arterial pulse. Possibly the cuff was also not fitted correctly . The cuff pressure does ...

  • Omron RX-1 - page 8

    English 8 Calibration The accuracy of this blood pressure monitor has been carefully tested and is designed for a long service life. It is generally recommended to have the moni- tor inspected every two years to ensure correct functioning and accuracy . Please consult your authorised dealer for the OMRON Customer Service at the address given on the ...

  • Omron RX-1 - page 9

    English 9 General information about blood pressure The blood circulation is responsible for supplying the body with oxygen. Blood pressure is the pressure exerted on the arteries when the blood flows through them. The higher blood pressure value (= systolic pressure or top value) signifies the blood pressure produced by contraction of the heart mus ...

Manufacturer Omron Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Omron RX-1 can be divided into several groups. They are, among others:
- Omron technical drawings
- RX-1 manuals
- Omron product data sheets
- information booklets
- or energy labels Omron RX-1
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron RX-1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron RX-1, service manual, brief instructions and user manuals Omron RX-1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron RX-1.

Similar manuals

A complete manual for the device Omron RX-1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron RX-1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron RX-1.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron RX-1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron RX-1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron RX-1, that we can find in the current document
3. Tips how to use the basic functions of the device Omron RX-1 - which should help us in our first steps of using Omron RX-1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron RX-1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron RX-1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron RX-1?

Use the form below

If you did not solve your problem by using a manual Omron RX-1, ask a question using the form below. If a user had a similar problem with Omron RX-1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)