    6H128-08 and 6H129-08 Smar tSwitch 6000 Modules User’ s Guide 2 3 4 5 6 1 COM CPU RESET 2 3 4 5 6 1 COM CPU RESET 1 2 3 4 5 6 1 2 3 4 5 6 7 8 6H129-08 FAST ENET 7 8 6H128-08 FAST ENET 9032364-02 ...

  • Cabletron Systems 6H128-08 - page 2

    ...

  • Cabletron Systems 6H128-08 - page 3

    6H128-08 and 6H129-08 User’ s Guide i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes ha ve been made. The hardware, firmware, or software described i ...

  • Cabletron Systems 6H128-08 - page 4

    Notice ii 6H128-08 and 6H129-08 User’ s Guide INDUSTRY CANADA NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépas ...

  • Cabletron Systems 6H128-08 - page 5

    Notice 6H128-08 and 6H129-08 User’ s Guide iii CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE . You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. Y ou may not copy , reproduce or transmit any part of the Program except as permitted by the Copyright ...

  • Cabletron Systems 6H128-08 - page 6

    Notice iv 6H128-08 and 6H129-08 User’ s Guide SAFETY INFORMATION CLASS 1 LASER TRANSCEIVERS THE FE-100F3 FAST ETHERNET INTERFACE MODULE USES CLASS 1 LASER TRANSCEIVERS. READ THE FOLLOWING SAFETY INFORMATION BEFORE INSTALLING OR OPERATING THESE MODULES. The Class 1 laser transceiv ers use an optical feedback loop to maintain Class 1 operation limi ...

  • Cabletron Systems 6H128-08 - page 7

    Notice 6H128-08 and 6H129-08 User’ s Guide v DECLARATION OF CONFORMITY Application of Council Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer’ s Name: Cabletron Systems, Inc. Manufacturer’ s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representativ e Name: Mr. J. Solari European Representativ e Address: Cabletron Syst ...

  • Cabletron Systems 6H128-08 - page 8

    Notice vi 6H128-08 and 6H129-08 User’ s Guide ...

  • Cabletron Systems 6H128-08 - page 9

    6H128-08 and 6H129-08 User’ s Guide vii CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Guide ......................................................................... 1-1 1.2 Structure of This Guide................................................................ 1-1 1.3 6H12X-08 Overview ........................................................... ...

  • Cabletron Systems 6H128-08 - page 10

    Contents viii 6H128-08 and 6H129-08 User’ s Guide CHAPTER 4 T R OUBLESHOOTING 4.1 Using LANVIEW ........................................................................... 4-1 4.2 FE-100TX LED ............................................................................. 4-5 4.3 Troubleshooting Checklist ........................................... ...

  • Cabletron Systems 6H128-08 - page 11

    Contents 6H128-08 and 6H129-08 User’ s Guide ix 5.15 General Configuration Screen ................................................... 5-40 5.15.1 Setting the IP Address .................................................. 5-44 5.15.2 Setting the Subnet Mask ............................................... 5-46 5.15.3 Setting the Default Gateway .... ...

  • Cabletron Systems 6H128-08 - page 12

    Contents x 6H128-08 and 6H129-08 User’ s Guide 5.26 Switch Statistics Screen ............................................................. 5-86 5.26.1 Using the Clear Counters Command ............................ 5-87 5.27 Interface Statistics Screen ......................................................... 5-88 5.27.1 Displaying Interface Statis ...

  • Cabletron Systems 6H128-08 - page 13

    6H128-08 and 6H129-08 User’ s Guide 1-1 CHAPTER 1 INTR ODUCTION W elcome to the Cabletron Systems 6H128-08 and 6H129-08 SmartSwitch 6000 Modules User’s Guide . This guide describes the 6H128-08 and 6H129-08 interface modules and pro vides information concerning network requirements, installation, troubleshooting, and the use of Local Management ...

  • Cabletron Systems 6H128-08 - page 14

    Chapter 1: Introduction 1-2 6H128-08 and 6H129-08 User’ s Guide Chapter 3 , Installation , provides instructions on ho w to install the module in the chassis and connect segments to the de vice. Chapter 4 , T r oubleshooting , details the 6H12X-08 LANVIEW LEDs that enable quick diagnosis of network/operational problems. Chapter 5 , Local Manageme ...

  • Cabletron Systems 6H128-08 - page 15

    6H12X-08 Overview 6H128-08 and 6H129-08 User’ s Guide 1-3 1.3 6H12X-08 OVERVIEW The 6H12X-08 (the 6H128-08 is sho wn in Figure 1-1 ) is a Fast Ethernet interface module for the Cabletron Systems 6C105 chassis. The module has six switched fiber optic ports and two optional ports for F ast Ethernet Interface Modules. The 6H128-08 has six multimode ...

  • Cabletron Systems 6H128-08 - page 16

    Chapter 1: Introduction 1-4 6H128-08 and 6H129-08 User’ s Guide Figure 1-1 The 6H12X-08 23640101 7 8 6H128-08 FAST ENET COM CPU RESET Reset Button CPU LED Port Status LEDs Network Ports 1-6 Optional Fast Ethernet Module Ports 7 and 8 COM Port 2 3 4 5 6 1 1 2 3 4 5 6 ...

  • Cabletron Systems 6H128-08 - page 17

    6H12X-08 Overview 6H128-08 and 6H129-08 User’ s Guide 1-5 1.3.3 Runtime IP Address Disco very This feature enables the 6H12X-08 to automatically accept an IP address from a BootP server on the netw ork into NVRAM without requiring a user to enter an IP address through Local Management. When the 6H12X-08 is connected to the network and po wered up ...

  • Cabletron Systems 6H128-08 - page 18

    Chapter 1: Introduction 1-6 6H128-08 and 6H129-08 User’ s Guide 1.3.5 Remote Monitoring (RMON) The 6H12X-08 supports all Ethernet RMON groups, which include Statistics, Alarms, Events and History . These groups are enabled on all ports by default. Cabletron Systems RMON Actions is a vendor specific e xtension of RMON and provides the ability to ...

  • Cabletron Systems 6H128-08 - page 19

    Local Management Features 6H128-08 and 6H129-08 User’ s Guide 1-7 1.3.9 LANVIEW Diagnostic LEDs The v arious conditions of the LANVIEW diagnostic LEDs serve as important troubleshooting aids. The y provide an easy w ay to observe the transmit and recei ve status of indi vidual ports and overall netw ork operations such as system status, switching ...

  • Cabletron Systems 6H128-08 - page 20

    Chapter 1: Introduction 1-8 6H128-08 and 6H129-08 User’ s Guide 1.4.4 SmartT runk SmartT runk, also referred to as SmartTrunking, is Cabletron Systems’ terminology for load balancing or load sharing. SmartT runk technology provides an easy-to-implement mechanism to group, or aggre gate, multiple physical links together to scale the backbone ban ...

  • Cabletron Systems 6H128-08 - page 21

    Optional Features 6H128-08 and 6H129-08 User’ s Guide 1-9 T able 1-1 F ast Ethernet Interface Modules P/N Description Application FE-100TX Uses RJ45 connector Suppor ts Categor y 5 Unshielded T wisted P air (UTP) cabling, which has an impedance of 85 to 111 ohms. FE-100FX Uses SC connector Suppor ts multimode fiber optic cab ling. FE-100F3 Uses ...

  • Cabletron Systems 6H128-08 - page 22

    Chapter 1: Introduction 1-10 6H128-08 and 6H129-08 User’ s Guide 1.6 DOCUMENT CON VENTIONS The follo wing con ventions are used throughout this document: NO TE Note symbol. Calls the reader’ s attention to any item of inf ormation that may be of special impor tance. TIP Tip symbol. Conv eys helpful hints concerning procedures or actions. ! CA U ...

  • Cabletron Systems 6H128-08 - page 23

    Getting Help 6H128-08 and 6H129-08 User’ s Guide 1-11 1.7 GETTING HELP For additional support related to this de vice or document, contact the Cabletron Systems Global Call Center: Before calling the Cabletron Systems Global Call Center, have the following information ready: • Y our Cabletron Systems service contract number • A description of ...

  • Cabletron Systems 6H128-08 - page 24

    Chapter 1: Introduction 1-12 6H128-08 and 6H129-08 User’ s Guide 1.8 RELATED MANUALS The follo wing manuals may help the user to setup and manage the 6H12X-08: Cabletron Systems 6C105 SmartSwitch 6000 Overvie w and Setup Guide Cabletron Systems Networking Guide Cabletron Systems Guide to Network T r oubleshooting Cabletron Systems Local Managemen ...

  • Cabletron Systems 6H128-08 - page 25

    6H128-08 and 6H129-08 User’ s Guide 2-1 CHAPTER 2 NETW ORK REQUIREMENTS Before installing the 6H12X-08 or Fast Ethernet Interf ace Modules, re vie w the requirements and specifications referred to in this chapter concerning the follo wing: • SmartT runk ( Section 2.1 ) • 10B ASE-T T wisted Pair Network ( Section 2.2 ) • 100B ASE-TX T wiste ...

  • Cabletron Systems 6H128-08 - page 26

    Chapter 2: Network Requirements 2-2 6H128-08 and 6H129-08 User’ s Guide 2.3 100B ASE-TX NETW ORK The 6H12X-08, with an FE-100TX installed in ports 7 or 8, provides an RJ45 connection that supports UTP cabling with an impedance between 85 and 111 ohms. The de vice at the other end of the twisted pair segment must meet IEEE 802.3u 100B ASE-TX Fast ...

  • Cabletron Systems 6H128-08 - page 27

    6H128-08 and 6H129-08 User’ s Guide 3-1 CHAPTER 3 INSTALLATION This chapter cov ers the required tools and instructions for installing the 6H12X-08 module into the 6C105 SmartSwitch 6000 chassis. Follo w the order provided belo w to correctly install the 6H12X-08. • Unpacking the 6H12X-08 ( Section 3.1 ) • Installing options ( Section 3.2 ) ? ...

  • Cabletron Systems 6H128-08 - page 28

    Chapter 3: Installation 3-2 6H128-08 and 6H129-08 User’ s Guide 3. Carefully remove the module, which is wrapped in a non-conductive bag, from the shipping box. 4. Peel off the black and yellow tape seal on the non-conductive bag to remove the module. 5. Remove the module from the non-conductive bag. Observe all precautions listed on the non-cond ...

  • Cabletron Systems 6H128-08 - page 29

    Installing the 6H12X-08 into the 6C105 Chassis 6H128-08 and 6H129-08 User’ s Guide 3-3 3.3 INSTALLING THE 6H12X-08 INTO THE 6C105 CHASSIS The 6H12X-08 can be installed in any of the fiv e slots that are av ailable in the 6C105 chassis. T o install a module, proceed as follo ws: 1. Locate the antistatic wrist strap shipped with the 6C105 chassis. ...

  • Cabletron Systems 6H128-08 - page 30

    Chapter 3: Installation 3-4 6H128-08 and 6H129-08 User’ s Guide Figure 3-1 Installing an Interface Module 1 2 3 45 PS1 PS2 Plastic Locking T ab Slot Number 2159-02 2159-01 7 8 COM CPU 6H128-08 FAST ENET 2 3 4 5 6 1 RESET Circuit Card Card Guides Metal Back-Panel Plastic Locking T ab 1 2 3 4 5 6 ...

  • Cabletron Systems 6H128-08 - page 31

    Connecting to the Network 6H128-08 and 6H129-08 User’ s Guide 3-5 3.4 CONNECTING TO THE NETWORK This section provides the procedures for connecting fiber optic and twisted pair segments from the netw ork or other de vices to the 6H12X-08. Ports 1 through 6 hav e SC connectors for fiber . The 6H128-08 supports multimode fiber , and the 6H129-08 ...

  • Cabletron Systems 6H128-08 - page 32

    Chapter 3: Installation 3-6 6H128-08 and 6H129-08 User’ s Guide Fiber Optic Network Connection 1. Remove the protective rubber covers from the fiber optic ports on the applicable port on the module and from the ends of the SC connectors. 2. Insert one end of the SC connector into the port on the 6H12X-08 module. See Figure 3-2 . 3. At the other e ...

  • Cabletron Systems 6H128-08 - page 33

    Connecting to the Network 6H128-08 and 6H129-08 User’ s Guide 3-7 Figure 3-2 6H12X-08 Fiber P ort Connection 4. Verify that a link exists by checking that the port RX LED is on (flashing amber, blinking green, or solid green). If the RX LED is off and the TX LED is not blinking amber, perform the following steps until it is on: a. Ensure that the ...

  • Cabletron Systems 6H128-08 - page 34

    Chapter 3: Installation 3-8 6H128-08 and 6H129-08 User’ s Guide c. Make sure that the fiber connection meets dB loss specifications for a 100BASE-FX link as specified in the Cabletron Systems Cabling Guide . d. See Section 5.19 for information on how to manage the connected port. If a link has not been established, refer to Chapter 4 , before con ...

  • Cabletron Systems 6H128-08 - page 35

    Connecting to the Network 6H128-08 and 6H129-08 User’ s Guide 3-9 If a crossov er is required, b ut crossov er cabling is not a v ailable, use the switch on the FE-100TX to internally cross ov er the RJ45 port. Figure 3-4 sho ws ho w to properly set the FE-100TX crossov er switch. Figure 3-4 FE-100TX Crosso ver Switch When connecting a workstatio ...

  • Cabletron Systems 6H128-08 - page 36

    Chapter 3: Installation 3-10 6H128-08 and 6H129-08 User’ s Guide e. Confirm that the crossover switch is in the correct position. If a link has not been established, refer to Appendix B and Chapter 4 before contacting the Cabletron Systems Global Call Center . Refer to Section 1.7 for details. 3.4.3 Connecting a Fiber Optic Segment to the FE-100F ...

  • Cabletron Systems 6H128-08 - page 37

    Connecting to the Network 6H128-08 and 6H129-08 User’ s Guide 3-11 2. Insert one end of the SC connector into the FE-100FX or FE-100F3 installed in the 6H12X-08 module. See Figure 3-5 . 3. At the other end of the fiber optic cable, attach the SC connector to the other device. Figure 3-5 FE-100FX and FE-100F3 P ort Connection 4. Verify that a link ...

  • Cabletron Systems 6H128-08 - page 38

    Chapter 3: Installation 3-12 6H128-08 and 6H129-08 User’ s Guide a. Ensure that the po wer is turned on for the de vice at the other end of the link. b. Verify that the fiber strands between the applicable port on the 6H12X-08 and fiber optic device on the other end of the segment are properly crossed over. c. Make sure that the fiber connection ...

  • Cabletron Systems 6H128-08 - page 39

    6H128-08 and 6H129-08 User’ s Guide 4-1 CHAPTER 4 T R OUBLESHOOTING This chapter provides information concerning the follo wing: • Using the LANVIEW diagnostic and status monitoring system • T roubleshooting network and module operational problems • Using the RESET button For more troubleshooting information about other Cabletron products, ...

  • Cabletron Systems 6H128-08 - page 40

    Chapter 4: T roubleshooting 4-2 6H128-08 and 6H129-08 User’ s Guide Figure 4-1 LANVIEW LEDs 2159-07 7 8 COM CPU 6H128-08 FAST ENET RESET CPU LED Receive (RX) T ransmit (TX) 2 3 4 5 6 1 Receive (RX) T ransmit (TX) 1 2 3 4 5 6 ...

  • Cabletron Systems 6H128-08 - page 41

    Using LANVIEW 6H128-08 and 6H129-08 User’ s Guide 4-3 T able 4-1 LANVIEW LEDs LED Color State Recommended Action CPU Off P ow er off. P ower up chassis. Red Blinking . Hardware f ailure has occurred. Contact the Cabletron Systems Global Call Center . Solid . Resetting, normal power up reset. None . Amber Blinking . Cr ippled. Contact the Cabletro ...

  • Cabletron Systems 6H128-08 - page 42

    Chapter 4: T roubleshooting 4-4 6H128-08 and 6H129-08 User’ s Guide TX (T ransmit) LED f or por ts 1–6, also por ts 7 and 8, with optional FE-100FX or FE-100F3 Off P or t enabled, and no activity . Should flash green e v ery 2 seconds indicating BPDUs being sent if ST A is enabled and there is a valid link. 1. Ensure that the STA is enabled an ...

  • Cabletron Systems 6H128-08 - page 43

    FE-100TX LED 6H128-08 and 6H129-08 User’ s Guide 4-5 4.2 FE-100TX LED The optional FE-100TX for the 6H12X-08 has one LED labeled 10/100. The 10/100 LED together with the recei ve LED allo ws the user to determine the link status and the operating speed of the Fast Ethernet Interface Module. The 10/100 LED and the Recei ve (RX) LED are sho wn in F ...

  • Cabletron Systems 6H128-08 - page 44

    Chapter 4: T roubleshooting 4-6 6H128-08 and 6H129-08 User’ s Guide 4.3 T ROUBLESHOOTING CHEC KLIST If the 6H12X-08 is not working properly , refer to T able 4-4 for a checklist of possible problems, causes, and recommended actions to resolve the problem. T able 4-4 T roubleshooting Chec klist Prob lem P ossible Cause Recommended Action All LEDs ...

  • Cabletron Systems 6H128-08 - page 45

    Using the RESET Button 6H128-08 and 6H129-08 User’ s Guide 4-7 4.4 USING THE RESET BUTTON The RESET button located near the upper plastic locking tab of the module (refer to Figure 4-3 ) resets the 6H12X-08 processor without af fecting the NVRAM. Figure 4-3 RESET Button T o reset the 6H12X-08 processor, press and release the RESET b utton. A non- ...

  • Cabletron Systems 6H128-08 - page 46

    Chapter 4: T roubleshooting 4-8 6H128-08 and 6H129-08 User’ s Guide ...

  • Cabletron Systems 6H128-08 - page 47

    6H128-08 and 6H129-08 User’ s Guide 5-1 CHAPTER 5 LOCAL MANAGEMENT This chapter explains ho w to set up a management terminal to access 6H12X-08 Local Management, and ho w to use the Local Management screens and commands. This chapter also pro vides instructions for attaching an Uninterruptible Po wer Supply to the 6H12X-08 using the Console Cabl ...

  • Cabletron Systems 6H128-08 - page 48

    Chapter 5: Local Management 5-2 6H128-08 and 6H129-08 User’ s Guide • Configure optional Fast Ethernet Interf ace Modules installed in the 6H12X-08. • Clear NVRAM. There are three ways to access Local Management: • Locally using a VT type terminal connected to the COM port of the 6H12X-08. • Remotely using a VT type terminal connected th ...

  • Cabletron Systems 6H128-08 - page 49

    Local Management Ke yboard Con ventions 6H128-08 and 6H129-08 User’ s Guide 5-3 5.2 LOCAL MANAGEMENT KE YBOAR D CON VENTIONS All ke y names appear as capital letters in this manual. T able 5-1 explains the ke yboard con ventions and the ke y functions that are used. T able 5-1 K eyboar d Conventions Ke y Function ENTER K e y RETURN K e y These ar ...

  • Cabletron Systems 6H128-08 - page 50

    Chapter 5: Local Management 5-4 6H128-08 and 6H129-08 User’ s Guide 5.3 MANAGEMENT T ERMINAL SETUP Use one of the follo wing systems to access Local Management: • An IBM or compatible PC running a VT series emulation software package • A Digital Equipment Corporation VT100 type terminal • A VT type terminal running emulation programs for th ...

  • Cabletron Systems 6H128-08 - page 51

    Management T erminal Setup 6H128-08 and 6H129-08 User’ s Guide 5-5 Figure 5-1 Management T erminal Connection 2364-10 1 23 45 PS1 PS2 FAST ENET 2 1 7 8 6E128-08 ETHERNET COM CPU 2 3 4 5 6 1 RESET COM Port 6H128-08 CPU RESET PC RJ45 COM Port RJ45-to-DB9 PC Adapter to PC UTP Cable with RJ45 Connectors 1 2 3 4 5 6 ...

  • Cabletron Systems 6H128-08 - page 52

    Chapter 5: Local Management 5-6 6H128-08 and 6H129-08 User’ s Guide 5.3.2 Management T erminal Setup P arameters T able 5-2 lists the setup parameters for the local management terminal. T able 5-2 VT T erminal Setup Display Setup Men u Columns -> Controls -> A uto Wrap -> Scroll -> T e xt Cursor -> Cursor Style -> 80 Columns Int ...

  • Cabletron Systems 6H128-08 - page 53

    Management T erminal Setup 6H128-08 and 6H129-08 User’ s Guide 5-7 5.3.3 T elnet Connections Once the module or chassis has a v alid IP address, the user can establish a T elnet session with Local Management from an y TCP/IP based node on the network. T elnet connections to the 6H12X-08 require the community name passwords assigned at the SNMP Co ...

  • Cabletron Systems 6H128-08 - page 54

    Chapter 5: Local Management 5-8 6H128-08 and 6H129-08 User’ s Guide Figure 5-2 Uninterruptible P ower Supply (UPS) Connection 5.4 ACCESSING LOCAL MANAGEMENT Access to Local Management is controlled through the Local Management Passw ord screen, Figure 5-3 . Whene ver a connection is made to the 6H12X-08 the Local Management Passw ord screen displ ...

  • Cabletron Systems 6H128-08 - page 55

    Accessing Local Management 6H128-08 and 6H129-08 User’ s Guide 5-9 Figure 5-3 Local Management P assw ord Screen 2. Enter the Password and press ENTER. The default super-user access password is “ public ” or press ENTER. • If an in valid password is entered, the terminal beeps and the cursor returns to the beginning of the passw ord entry ? ...

  • Cabletron Systems 6H128-08 - page 56

    Chapter 5: Local Management 5-10 6H128-08 and 6H129-08 User’ s Guide 5.4.1 Navigating Local Mana gement Screens The 6H12X-08 Local Management application consists of a series of menu screens. Navigate through Local Management by selecting items from the menu screens. The 6H12X-08 supports three modes of switch operation. The switching modes are a ...

  • Cabletron Systems 6H128-08 - page 57

    Accessing Local Management 6H128-08 and 6H129-08 User’ s Guide 5-11 Figure 5-4 802.1D Switching Mode, LM Screen Hierar ch y Figure 5-5 802.1Q Switching Mode, LM Screen Hierar ch y Module Configuration Menu 2364_43 Module Specific Configuration Network T ools SmartTrunk Configuration Port Redirect Function System Resources Flash Download Broadca ...

  • Cabletron Systems 6H128-08 - page 58

    Chapter 5: Local Management 5-12 6H128-08 and 6H129-08 User’ s Guide Figure 5-6 SecureFast VLAN Mode , LM Screen Hierar ch y 5.4.2 Selecting Local Management Menu Screen Items Select items on a menu screen by performing the follo wing steps: 1. Use the arrow keys to highlight a menu item. 2. Press ENTER. The selected menu item displays on the s ...

  • Cabletron Systems 6H128-08 - page 59

    Accessing Local Management 6H128-08 and 6H129-08 User’ s Guide 5-13 Using the RETURN Command 1. Use the arrow keys to highlight the RETURN command at the bottom of the Local Management screen. 2. Press ENTER. The previous screen in the Local Management hierarchy displays. 3. Exit from 6H12X-08 Local Management by repeating steps 1 and 2 until the ...

  • Cabletron Systems 6H128-08 - page 60

    Chapter 5: Local Management 5-14 6H128-08 and 6H129-08 User’ s Guide 5.5 THE MAIN MENU SCREEN The Main Menu screen is the access point for all Local Management screens for the module and the 6C105 chassis. Figure 5-7 sho ws the Main Menu screen. Figure 5-7 Main Menu Screen The follo wing explains each Main Menu screen menu item as sho wn in Figur ...

  • Cabletron Systems 6H128-08 - page 61

    Chassis Menu Screen 6H128-08 and 6H129-08 User’ s Guide 5-15 5.6 CHASSIS MENU SCREEN The Chassis Menu screen, Figure 5-8 , provides access to Local Management screens that allo w you to configure and monitor operating parameters, modify SNMP community names, set SNMP traps, monitor the 6C105 en vironmental status, and perform port redirect funct ...

  • Cabletron Systems 6H128-08 - page 62

    Chapter 5: Local Management 5-16 6H128-08 and 6H129-08 User’ s Guide SNMP COMMUNITY NAMES The SNMP Community Names screen allo ws the user to enter ne w , change, or re vie w the community names used as access passwords for de vice management operation. Access is limited based on the password le vel of the user . F or details, refer to Section 5. ...

  • Cabletron Systems 6H128-08 - page 63

    Chassis Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-17 5.7 CHASSIS CONFIGURATION SCREEN The Chassis Configuration screen, Figure 5-9 , allo ws the user to set the chassis date and time, screen refresh and lockout time, IP address, subnet mask, the Operational Mode of all modules installed in the chassis, and to vie w the chassis ...

  • Cabletron Systems 6H128-08 - page 64

    Chapter 5: Local Management 5-18 6H128-08 and 6H129-08 User’ s Guide Subnet Mask (Read-Only) Displays the subnet mask for the chassis. A subnet mask “masks out” the network bits of the IP address by setting the bits in the mask to 1 when the network treats the corresponding bits in the IP address as part of the network or subnetwork address, ...

  • Cabletron Systems 6H128-08 - page 65

    Chassis Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-19 Screen Lock out Time (Modifiable) Contains the maximum number of minutes that the Local Management application displays a module’ s screen while aw aiting input or action from a user . For e xample, if the number 5 is entered in this field, the user has up to five minutes ...

  • Cabletron Systems 6H128-08 - page 66

    Chapter 5: Local Management 5-20 6H128-08 and 6H129-08 User’ s Guide 5.7.1 Setting the IP Address T o set the IP address, perform the following steps: 1. Use the arrow keys to highlight the IP Address field. 2. Enter the IP address into this field using Decimal Dotted Notation (DDN) format. For example: 134.141.79.120 3. Press ENTER. If the IP ad ...

  • Cabletron Systems 6H128-08 - page 67

    Chassis Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-21 3. Press ENTER. If the subnet mask is valid, the cursor returns to the beginning of the Subnet Mask field. If the entry is not valid, the Event Message Line displays “INVALID SUBNET MASK OR FORMAT ENTERED”. Local Management does not alter the current value, but it does ref ...

  • Cabletron Systems 6H128-08 - page 68

    Chapter 5: Local Management 5-22 6H128-08 and 6H129-08 User’ s Guide 5.7.4 Setting the Chassis Time T o set the chassis time, perform the following steps: 1. Use the arrow keys to highlight the Chassis Time field. 2. Enter the time in a 24-hour format: HH:MM:SS. 3. Press ENTER to set the chassis clock to the time in the input field. 4. Use the ar ...

  • Cabletron Systems 6H128-08 - page 69

    Chassis Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-23 4. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER. If the time entered is within the 3 to 99 seconds range, the Event Message Line at the top of the screen displays “SA VED OK”. If the entry is not v alid, Local Management does ...

  • Cabletron Systems 6H128-08 - page 70

    Chapter 5: Local Management 5-24 6H128-08 and 6H129-08 User’ s Guide 3. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER. The warning screen in Figure 5-10 displays: Figure 5-10 Operational Mode W arning Screen 4. Use the arrow keys to highlight the YES command and press ENTER. The changes are saved, an ...

  • Cabletron Systems 6H128-08 - page 71

    SNMP Community Names Screen 6H128-08 and 6H129-08 User’ s Guide 5-25 5.8 SNMP COMMUNITY NAMES SCREEN The SNMP Community Names screen allo ws the user to set community names. Community names act as passwords to Local/Remote Management and determine the le vel of security access to the 6C105. Access to the 6C105 is controlled by enacting any of thr ...

  • Cabletron Systems 6H128-08 - page 72

    Chapter 5: Local Management 5-26 6H128-08 and 6H129-08 User’ s Guide The follo wing explains each SNMP Community Names screen field: Community Name (Modifiab le) Displays the user-defined name through which a user accesses 6C105 management. Any community name assigned here acts as a passw ord to Local/Remote Management. Access P olicy (Read-On ...

  • Cabletron Systems 6H128-08 - page 73

    SNMP Community Names Screen 6H128-08 and 6H129-08 User’ s Guide 5-27 5.8.1 Establishing Comm unity Names The password used to access Local Management at the P assword screen must hav e super-user access in order to vie w and edit the SNMP Community Names screen. Using a community name with read-only or read-write access does not allo w the user t ...

  • Cabletron Systems 6H128-08 - page 74

    Chapter 5: Local Management 5-28 6H128-08 and 6H129-08 User’ s Guide 5.9 SNMP T RAPS SCREEN Since the 6C105 is an SNMP compliant de vice, it can send messages to multiple Network Management Stations to alert users of status changes. The Chassis SNMP T raps screen is shown in Figure 5-12 . Access the Chassis SNMP T raps screen from the Chassis Men ...

  • Cabletron Systems 6H128-08 - page 75

    SNMP T raps Screen 6H128-08 and 6H129-08 User’ s Guide 5-29 Enable T raps (T oggle) Enables transmission of the traps to the network management station with the associated IP address. This field toggles between YES and NO. 5.9.1 Configuring the T rap T able T o configure the T rap table, proceed as follows: 1. Using the arrow keys, highlight t ...

  • Cabletron Systems 6H128-08 - page 76

    Chapter 5: Local Management 5-30 6H128-08 and 6H129-08 User’ s Guide 5.10 CHASSIS EN VIRONMENTAL SCREEN The Chassis En vironmental screen allows the user to vie w chassis en vironmental information. T o access the Chassis Environmental Information screen from the Chassis Configuration screen, use the arro w ke ys to highlight the CHASSIS ENVIR O ...

  • Cabletron Systems 6H128-08 - page 77

    P or t Redirect Function Screen 6H128-08 and 6H129-08 User’ s Guide 5-31 Chassis Fan Status (Read-Only) Displays the current status of the 6C105 fan tray . This field displays either “Normal”, “Fault”, or “Not Installed”. 5.11 P ORT REDIRECT FUNCTION SCREEN The Port Redirect Function screen, Figure 5-14 , allo ws the user to set each ...

  • Cabletron Systems 6H128-08 - page 78

    Chapter 5: Local Management 5-32 6H128-08 and 6H129-08 User’ s Guide T o access the Port Redirect Function screen from the Chassis Menu screen, use the arro w ke ys to highlight the POR T REDIRECT FUNCTION menu item and press ENTER. The Port Redirect Function screen, Figure 5-14 , displays. Figure 5-14 P ort Redirect Function Screen The follo win ...

  • Cabletron Systems 6H128-08 - page 79

    P or t Redirect Function Screen 6H128-08 and 6H129-08 User’ s Guide 5-33 Remap Error s (Read-only) Displays whether the corresponding source modules and ports are configured to send errored frames to the destination modules and ports, or to drop all errored frames before forwarding traf fic. Source Module [ n ] (Selectable) Allo ws a selected m ...

  • Cabletron Systems 6H128-08 - page 80

    Chapter 5: Local Management 5-34 6H128-08 and 6H129-08 User’ s Guide 5.11.1 Displaying the Sour ce and Destination Entries There can be more than one Port Redirect Function screen depending on the number of port redirect entries. Each screen displays up to ten port redirect entries. If there is more than one screen of redirect entries, the NEXT a ...

  • Cabletron Systems 6H128-08 - page 81

    Module Selection Screen 6H128-08 and 6H129-08 User’ s Guide 5-35 8. Use the SPACE bar or BACKSPACE to step to the appropriate interface number for the destination interface. 9. Use the arrow keys to highlight the Errors field. 10. Use the SPACE bar to select either the ON or OFF option and press ENTER. ON forces the source module and port to forw ...

  • Cabletron Systems 6H128-08 - page 82

    Chapter 5: Local Management 5-36 6H128-08 and 6H129-08 User’ s Guide Figure 5-15 Module Selection Screen The follo wing explains each Module Selection screen field as sho wn in Figure 5-15 . SLO T # (Selectable) The module number displays the slot number in which the module is installed. The module number enclosed in < > characters indicat ...

  • Cabletron Systems 6H128-08 - page 83

    Module Menu Screen 6H128-08 and 6H129-08 User’ s Guide 5-37 5.12.1 Selecting a Module T o select an individual module to perform Local Management functions, proceed as follo ws: 1. Use the arrow keys to highlight the desired module number in the SLOT # field. 2. Press ENTER, the applicable Module Menu screen displays. Proceed to Section 5.13 . 5. ...

  • Cabletron Systems 6H128-08 - page 84

    Chapter 5: Local Management 5-38 6H128-08 and 6H129-08 User’ s Guide The follo wing explains each Module Menu screen field as sho wn in Figure 5-16 : MODULE CONFIGURA TION The Module Configuration screen provides access to the Local Management screens that are used to configure the 6H12X-08, and also to the Module Specific Configuration scre ...

  • Cabletron Systems 6H128-08 - page 85

    Module Configuration Menu Screen 6H128-08 and 6H129-08 User’ s Guide 5-39 T o access the Module Configuration Menu screen from the Module Menu screen, use the arro w ke ys to highlight the MODULE CONFIGURA TION menu item and press ENTER. The Module Configuration screen displays. Figure 5-17 Module Configuration Menu Screen The follo wing brie ...

  • Cabletron Systems 6H128-08 - page 86

    Chapter 5: Local Management 5-40 6H128-08 and 6H129-08 User’ s Guide SNMP TRAPS The SNMP T raps screen provides display and configuration access to the table of IP addresses used for trap destinations and associated community names. For details, refer to Section 5.17 . SWITCH CONFIGURA TION The Switch Configuration screen provides basic setup o ...

  • Cabletron Systems 6H128-08 - page 87

    General Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-41 Figure 5-18 General Configuration Screen The follo wing briefly explains each General Configuration screen field: MA C Address (Read-Only) Displays the base physical address of the module. IP Address (Modifiab le) This display allo ws the IP address to be set for the 6H12 ...

  • Cabletron Systems 6H128-08 - page 88

    Chapter 5: Local Management 5-42 6H128-08 and 6H129-08 User’ s Guide Default Gatewa y (Modifiab le) Displays the default gate way for the 6H12X-08. This field is not defined until an appropriate v alue is entered. For details about why and ho w to set the default gate way , refer to Section 5.15.3 . TFTP Gatewa y IP Addr (Modifiab le) Display ...

  • Cabletron Systems 6H128-08 - page 89

    General Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-43 In 802.1D SWITCHING mode, the 6 fiber ports and the 2 optional Interface Module ports are bridged to each other . In 802.1Q SWITCHING mode, the 6H12X-08 is able to increase its switching functionality by creating and maintaining IEEE port based VLANs. When the operational mod ...

  • Cabletron Systems 6H128-08 - page 90

    Chapter 5: Local Management 5-44 6H128-08 and 6H129-08 User’ s Guide Application (T oggle) Displays the application set for the COM port. This field allo ws you to set the application that the COM port will support, which includes: • Local Management (LM) via a terminal or modem connection • Uninterruptible Po wer Supply (UPS) The UPS settin ...

  • Cabletron Systems 6H128-08 - page 91

    General Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-45 2. Enter the IP address into this field using Decimal Dotted Notation (DDN) format. For example: 134.141.79.120 3. Press ENTER. If the IP address is a valid format, the cursor returns to the beginning of the IP address field. If the entry is not valid, the Event Message Line d ...

  • Cabletron Systems 6H128-08 - page 92

    Chapter 5: Local Management 5-46 6H128-08 and 6H129-08 User’ s Guide 5.15.2 Setting the Subnet Mask If the management workstation that is to recei ve SNMP traps from the 6H12X-08 is located on a separate subnet, the subnet mask for the 6H12X-08 must be changed from its default. T o change the subnet mask from its default, or if a separate subnet ...

  • Cabletron Systems 6H128-08 - page 93

    General Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-47 3. Press ENTER. If the default gateway entered is a valid format, the cursor returns to the beginning of the Default Gateway field. If the entry is not valid, the Event Message Line displays “INVALID DEFAULT GATEWAY OR FORMAT ENTERED”. Local Management does not alter the c ...

  • Cabletron Systems 6H128-08 - page 94

    Chapter 5: Local Management 5-48 6H128-08 and 6H129-08 User’ s Guide 5.15.5 Setting the Module Date The modules are year 2000 compliant, so the module date may be set beyond the year 1999. T o set the module date, perform the following steps: 1. Use the arrow keys to highlight the Module Date field. 2. Enter the date in this format: MM/DD/YYYY 3. ...

  • Cabletron Systems 6H128-08 - page 95

    General Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-49 3. Press ENTER to set the module time to the time in the input field. 4. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER. If the time entered is a v alid format, the Ev ent Message Line at the top of the screen displays “SA VED OK ...

  • Cabletron Systems 6H128-08 - page 96

    Chapter 5: Local Management 5-50 6H128-08 and 6H129-08 User’ s Guide 5.15.8 Setting the Screen Lockout Time The screen lockout time can be set from 1 to 30 minutes with a default of 15 minutes. T o set a ne w lockout time, perform the follo wing steps: 1. Use the arrow keys to highlight the Screen Lockout Time field. 2. Enter a number from 1 to 3 ...

  • Cabletron Systems 6H128-08 - page 97

    General Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-51 2. Press the SPACE bar to step to the appropriate operation mode, ( 802.1D SWITCHING , 802.1Q SWITCHING , or SECURE FAST VLAN ). 3. Use the arrow keys to highlight the SAVE command at the bottom of the screen and press ENTER. The warning screen shown back in Figure 5-19 displa ...

  • Cabletron Systems 6H128-08 - page 98

    Chapter 5: Local Management 5-52 6H128-08 and 6H129-08 User’ s Guide 3. Use the arrow keys to highlight the SAVE command at the bottom of the screen. Then press ENTER. The warning screen shown back in Figure 5-19 displays. 4. Use the arrow keys to highlight the YES command and press ENTER. The changes are saved to memory, and the module reboots. ...

  • Cabletron Systems 6H128-08 - page 99

    General Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-53 Figure 5-20 COM P ort W arning Screen 3. Use the arrow keys to highlight YES . Press ENTER. ! CA UTION If the COM por t is reconfigured without a valid IP address set on the module or chassis, the message sho wn in Figure 5-20 displa ys. Do not contin ue unless the outcome of ...

  • Cabletron Systems 6H128-08 - page 100

    Chapter 5: Local Management 5-54 6H128-08 and 6H129-08 User’ s Guide 4. If you ENABLED the port, proceed to Section 5.15.11.1 , Changing the Com Port A pplication . If you DISABLED the port, use the arrow keys to highlight SAVE at the bottom of the screen, then press ENTER.When the message “SAVED OK” displays, the edits are saved. 5.15.11.1 C ...

  • Cabletron Systems 6H128-08 - page 101

    General Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-55 5. When the message “SAVED OK” appears, the edits you made are saved. 5.15.12 Clearing NVRAM Clearing NVRAM allo ws the user to clear all user-entered parameters, such as IP address and Community Names from NVRAM. Clear NVRAM as follo ws: 1. Use the arrow keys to highlight ...

  • Cabletron Systems 6H128-08 - page 102

    Chapter 5: Local Management 5-56 6H128-08 and 6H129-08 User’ s Guide 5. Press YES and the message “CLEARING NVRAM. REBOOT IN PROGRESS...” displays. The 6H12X-08 will clear NVRAM and reboot. All user-entered parameters default to factory settings. 5.15.13 Enabling/Disabling IP Fra gmentation T o enable or disable IP fragmentation, proceed as f ...

  • Cabletron Systems 6H128-08 - page 103

    SNMP Community Names Screen 6H128-08 and 6H129-08 User’ s Guide 5-57 T o access the SNMP Community Names screen from the Module Configuration Menu screen, use the arro w ke ys to highlight the SNMP COMMUNITY NAMES menu item and press ENTER. The SNMP Community Names screen, Figure 5-22 , displays. Figure 5-22 SNMP Community Names Screen NO TE If ...

  • Cabletron Systems 6H128-08 - page 104

    Chapter 5: Local Management 5-58 6H128-08 and 6H129-08 User’ s Guide The follo wing explains each SNMP Community Names screen field: Community Name (Modifiab le) Displays the user-defined name through which a user accesses 6H12X-08 management. Any community name assigned here acts as a passw ord to Local/Remote Management. Access P olicy (Read ...

  • Cabletron Systems 6H128-08 - page 105

    SNMP Community Names Screen 6H128-08 and 6H129-08 User’ s Guide 5-59 T o establish community names, proceed as follows: 1. Use the arrow keys to highlight the Community Name field adjacent to the selected access level. 2. Enter the password in the field (maximum 31 characters). 3. Press ENTER. 4. Repeat steps 1 through 3 to modify the other commu ...

  • Cabletron Systems 6H128-08 - page 106

    Chapter 5: Local Management 5-60 6H128-08 and 6H129-08 User’ s Guide 5.17 SNMP T RAPS SCREEN Since the 6H12X-08 is an SNMP compliant de vice, it can send messages to multiple Network Management Stations to alert users of status changes. The SNMP Traps screen is sho wn in Figure 5-23 . Access the SNMP T raps screen from the Module Configuration M ...

  • Cabletron Systems 6H128-08 - page 107

    SNMP T raps Screen 6H128-08 and 6H129-08 User’ s Guide 5-61 T rap Comm unity Name (Modifiable) Displays the Community Name included in the trap message sent to the Network Management Station with the associated IP address. Enable T raps (T oggle) Enables transmission of the traps to the network management station with the associated IP address. ...

  • Cabletron Systems 6H128-08 - page 108

    Chapter 5: Local Management 5-62 6H128-08 and 6H129-08 User’ s Guide 5.18 SWITCH CONFIGURATION SCREEN The Switch Configuration screen, Figure 5-24 , provides the basic setup options to make a switch operational in your network. T o access the Switch Configuration screen from the Module Configuration Menu screen, use the arro w keys to highligh ...

  • Cabletron Systems 6H128-08 - page 109

    Switch Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-63 Figure 5-24 Switch Configuration Screen The follo wing describes each field of the Switch Configuration screen: Switch Address (Read-Only) Displays the base MA C address of the switch. Number of P or ts (Read-Only) Displays the total number of switched ports on the module. T ...

  • Cabletron Systems 6H128-08 - page 110

    Chapter 5: Local Management 5-64 6H128-08 and 6H129-08 User’ s Guide Age Time (sec) (Modifiable) Allo ws the user to set the amount of time (in seconds) the 6H12X-08 will keep an address in its switch table before discarding it. The modules will discard an address from their switch table if they do not recei ve a v alid Bridge Protocol Data Unit ...

  • Cabletron Systems 6H128-08 - page 111

    Switch Configuration Screen 6H128-08 and 6H129-08 User’ s Guide 5-65 5.18.1 Setting the ST A The Spanning T ree Algorithm (ST A) setting allows the user to set the method that the switches use to decide which is the controller (Root) switch when two or more switches are in parallel. The av ailable selections are IEEE, DEC, and NONE. T o set the ...

  • Cabletron Systems 6H128-08 - page 112

    Chapter 5: Local Management 5-66 6H128-08 and 6H129-08 User’ s Guide 5.18.3 Setting (Enabling or Disabling) the P or t Status T o set the status of an interface (port), proceed as follows: 1. Use the arrow keys to highlight the Status field of the port. 2. Use the SPACE bar to toggle to either ENABLED or DISABLED . 3. Use the arrow keys to highli ...

  • Cabletron Systems 6H128-08 - page 113

    Ethernet Interface Configuration 6H128-08 and 6H129-08 User’ s Guide 5-67 Figure 5-25 Ethernet Interface Configuration Screen for the 6H12X-08 The follo wing section briefly e xplains each field of the Ethernet Interface Configuration screen: P or t Num (Read-only) Displays the port number of the front panel interface. P or t T ype (Read-Onl ...

  • Cabletron Systems 6H128-08 - page 114

    Chapter 5: Local Management 5-68 6H128-08 and 6H129-08 User’ s Guide Current Oper . Mode (Read-only) This field displays the current operating mode of a port. Depending on the interface installed (100B ASE-FX or 100B ASE-TX), this field displays the follo wing: • 100Base-TX interface – Auto-Ne g, Unkno wn (if there is no link), 10Base-T , 1 ...

  • Cabletron Systems 6H128-08 - page 115

    Ethernet Interface Configuration 6H128-08 and 6H129-08 User’ s Guide 5-69 Advertised Ability (Selectable) During auto-negotiation, the FE-100TX “tells” the de vice at the other end of the segment what its capabilities are. The capabilities of a port with an FE-100TX installed are 10B ASE-T , 10B ASE-TFD (full duplex mode), 100B ASE-TX and 10 ...

  • Cabletron Systems 6H128-08 - page 116

    Chapter 5: Local Management 5-70 6H128-08 and 6H129-08 User’ s Guide 5.19.2 Configuring an FE-100TX Interface In normal operation, a port with an FE-100TX interface automatically establishes a link with the de vice at the other end of the segment and no user setup is required. Section 5.19.3 and Section 5.19.4 provide instructions for manually c ...

  • Cabletron Systems 6H128-08 - page 117

    Module Specific Configuration Menu 6H128-08 and 6H129-08 User’ s Guide 5-71 4. Use the SPACE bar to select Enabled or Disabled . Press ENTER. 5. Use the LEFT-ARROW key to move back to the Advertised Ability selection and use the SPACE bar to select the next mode to enable or disable. Continue this process until you have completed enabling or di ...

  • Cabletron Systems 6H128-08 - page 118

    Chapter 5: Local Management 5-72 6H128-08 and 6H129-08 User’ s Guide The follo wing briefly explains each screen accessible from the Module Specific Configuration Menu screen: SYSTEM RESOURCES The System Resources screen provides processor and FLASH memory information on the 6H12X-08, and allo ws Peak Utilization to be reset. For details, refe ...

  • Cabletron Systems 6H128-08 - page 119

    System Resources Screen 6H128-08 and 6H129-08 User’ s Guide 5-73 Figure 5-27 System Resources Screen The follo wing briefly e xplains each field of the System Resources screen. CPU T ype (Read-only) Indicates the microprocessor used in the 6H12X-08. Flash Memory Installed (Read-only) Indicates the amount of FLASH memory installed in the 6H12X-0 ...

  • Cabletron Systems 6H128-08 - page 120

    Chapter 5: Local Management 5-74 6H128-08 and 6H129-08 User’ s Guide P eak Switch Utilization (Read-only) Sho ws the peak percentage of maximum switching capacity , since last reset. Reset P eak Switch Utilization (T oggle) Allo ws the user to reset the Peak Switch Utilization field. The switch may be set to either YES or NO as described in Sect ...

  • Cabletron Systems 6H128-08 - page 121

    Flash Download Screen 6H128-08 and 6H129-08 User’ s Guide 5-75 T o access the Flash Download screen from the Module Specific Configuration screen, use the arro w ke ys to highlight the FLASH DO WNLO AD menu item and press ENTER. The Flash Download screen displays. Figure 5-28 Flash Download Screen The follo wing briefly explains each field of ...

  • Cabletron Systems 6H128-08 - page 122

    Chapter 5: Local Management 5-76 6H128-08 and 6H129-08 User’ s Guide Reboot After Download (Modifiab le only when RUNTIME is chosen) This field notifies the user that the 6H12X-08 will reboot after the do wnload is complete. If a R UNTIME Download is performed this field toggles between YES and NO. If YES is selected, the module reboots after ...

  • Cabletron Systems 6H128-08 - page 123

    Flash Download Screen 6H128-08 and 6H129-08 User’ s Guide 5-77 4. Set the IP address of the TFTP gateway server (this defaults to the same IP address as that set in the TFTP Gateway IP Addr field on the General Configuration screen). 5. Use the arrow keys to highlight the Download Server IP field. 6. Enter the IP address of the TFTP server using ...

  • Cabletron Systems 6H128-08 - page 124

    Chapter 5: Local Management 5-78 6H128-08 and 6H129-08 User’ s Guide 8. Enter the IP address of the TFTP server using the DDN format. For example: 134.141.79.121 9. Use the arrow keys to highlight the Download File Name field. 10. Enter the complete path and file name of the image stored on the download server. For example: /tftpboot/6H128.fls 11 ...

  • Cabletron Systems 6H128-08 - page 125

    P or t Redirect Function Screen 6H128-08 and 6H129-08 User’ s Guide 5-79 5.23 P ORT REDIRECT FUNCTION SCREEN The Port Redirect Function screen, Figure 5-29 allo ws the user to set each one of the ports on the 6H12X-08 as a source or destination port. A port can be set to hav e one or more destination ports. For example, port 1 can be set as a sou ...

  • Cabletron Systems 6H128-08 - page 126

    Chapter 5: Local Management 5-80 6H128-08 and 6H129-08 User’ s Guide Figure 5-29 P ort Redirect Function Screen The follo wing definitions briefly explain each field of the Port Redirect Function screen: Source P ort (Read-only) Sho ws which ports are currently set as source ports. Destination P or t (Read-only) Sho ws which ports are currentl ...

  • Cabletron Systems 6H128-08 - page 127

    P or t Redirect Function Screen 6H128-08 and 6H129-08 User’ s Guide 5-81 Error s (T oggle) Allo ws the user to configure the source ports to either send errored frames to selected destination ports, or to drop errored frames, and send only v alid traffic to the destination ports. The default setting of this field is ON. For information on ho w ...

  • Cabletron Systems 6H128-08 - page 128

    Chapter 5: Local Management 5-82 6H128-08 and 6H129-08 User’ s Guide 5. Use the arrow keys to highlight the Errors field. 6. Use the SPACE bar to select either the ON or OFF option and press ENTER. ON forces the source module and port to forward errored frames and valid traffic to the destination module(s) and port(s). OFF forces the errored fram ...

  • Cabletron Systems 6H128-08 - page 129

    Broadcast Suppression Screen 6H128-08 and 6H129-08 User’ s Guide 5-83 Figure 5-30 Broadcast Suppression Screen The follo wing explains each field of the Broadcast Suppression screen: P or t # (Read-only) Identifies the number of the port. T otal RX (Read-Only) Displays the total number of broadcast frames recei ved. P eak Rate (Read-Only) Displ ...

  • Cabletron Systems 6H128-08 - page 130

    Chapter 5: Local Management 5-84 6H128-08 and 6H129-08 User’ s Guide 5.24.1 Setting the Threshold T o set the Threshold, proceed as follo ws: 1. Use the arrow keys to highlight the Threshold field for the selected port. 2. Type in the numbers for the desired limit in increments of 10 (for example, 10, 20, 30, etc.). 3. Use the arrow keys to highl ...

  • Cabletron Systems 6H128-08 - page 131

    Module Statistics Menu Screen 6H128-08 and 6H129-08 User’ s Guide 5-85 T o access the Module Statistics Menu from the Module Menu screen, use the arro w ke ys to highlight the MODULE ST A TISTICS menu item and press ENTER. The Module Statistics Menu screen displays. Figure 5-31 Module Statistics Menu Screen The Module Statistics Menu screen displ ...

  • Cabletron Systems 6H128-08 - page 132

    Chapter 5: Local Management 5-86 6H128-08 and 6H129-08 User’ s Guide 5.26 SWITCH STATISTICS SCREEN The Switch Statistics screen, Figure 5-32 , lists the number of frames recei v ed, transmitted, filtered, and forw arded by each interf ace, including backplane interfaces. T o access the Switch Statistics screen from the Module Statistics Menu scr ...

  • Cabletron Systems 6H128-08 - page 133

    Switch Statistics Screen 6H128-08 and 6H129-08 User’ s Guide 5-87 The Switch Statistics screen displays the follo wing fields: Po r t # (Read-Only) Identifies the port number . Frames Rcvd (Read-Only) Displays the number of frames recei ved by the port. Frames Txmtd (Read-Only) Displays the number of frames transmitted by the port. Frames Fltrd ...

  • Cabletron Systems 6H128-08 - page 134

    Chapter 5: Local Management 5-88 6H128-08 and 6H129-08 User’ s Guide 5.27 INTERFACE STATISTICS SCREEN The Interface Statistics screen is used to gather MIB-II statistics for all of the 6H12X-08 interfaces (ports 1 through 6, optional F ast Ethernet Interface Modules, and all backplane interfaces). T o access the Interface Statistics screen, use t ...

  • Cabletron Systems 6H128-08 - page 135

    Interface Statistics Screen 6H128-08 and 6H129-08 User’ s Guide 5-89 Name (Read-only) The Name field displays the type of interface for which statistics are being displayed. InOctets (Read-only) This field displays the total number of octets (bytes) that hav e been recei ved on the interf ace. This includes all octets from bad frames, and frami ...

  • Cabletron Systems 6H128-08 - page 136

    Chapter 5: Local Management 5-90 6H128-08 and 6H129-08 User’ s Guide OutNonUnicast (Read-only) This field displays the total number of frames transmitted to a broadcast or multicast address. OutDiscards (Read-only) The OutDiscards field displays the total number of outbound frames that were discarded, e ven though the frames contained no errors ...

  • Cabletron Systems 6H128-08 - page 137

    Interface Statistics Screen 6H128-08 and 6H129-08 User’ s Guide 5-91 Link Status (Read-only) This field displays the current link status of the interface. This field will read either “Link” or “No Link”. Duplex Mode (Read-only) This field indicates whether the interface is operating in normal or full duplex mode. This field will read ...

  • Cabletron Systems 6H128-08 - page 138

    Chapter 5: Local Management 5-92 6H128-08 and 6H129-08 User’ s Guide 5.28 RMON STATISTICS SCREEN RMON statistics for each interface, on a interface-by-interf ace basis, are vie wed through the RMON Statistics screen sho wn in Figure 5-34 . T o access the RMON Statistics screen, use the arrow ke ys to highlight the RMON ST A TISTICS menu item on t ...

  • Cabletron Systems 6H128-08 - page 139

    RMON Statistics Screen 6H128-08 and 6H129-08 User’ s Guide 5-93 Data Source (Read-only) This field displays the source of the statistics data that is currently being displayed on the screen. Figure 5-34 sho ws that the data source for this RMON index is Interf ace 1 (Port 1) by displaying the name IfIndex.1. If the screen was displaying RMON sta ...

  • Cabletron Systems 6H128-08 - page 140

    Chapter 5: Local Management 5-94 6H128-08 and 6H129-08 User’ s Guide Undersized Pkts (Read-only) The Undersized Pkts field displays the number of frames recei ved whose size was less than the minimum Ethernet frame size of 64 bytes, not including preamble, but ha ve a v alid CRC. Oversized Pkts (Read-only) The Oversized Pkts field displays the ...

  • Cabletron Systems 6H128-08 - page 141

    RMON Statistics Screen 6H128-08 and 6H129-08 User’ s Guide 5-95 128 - 255 Octets (Read-only) Displays the total number of frames, including bad frames, recei ved that were between 128 and 255 bytes in length (excluding framing bits, b ut including FCS bytes). 256 - 511 Octets (Read-only) Displays the total number of frames, including bad frames, ...

  • Cabletron Systems 6H128-08 - page 142

    Chapter 5: Local Management 5-96 6H128-08 and 6H129-08 User’ s Guide 5.28.2 Using the Clear Counters Command T o reset all the statistics counters of the selected interface to zero, perform the follo wing steps: 1. Use the arrow keys to highlight the CLEAR COUNTERS field. 2. Press ENTER, the counters for the selected index are reset to zero. 5.29 ...

  • Cabletron Systems 6H128-08 - page 143

    Network T ools 6H128-08 and 6H129-08 User’ s Guide 5-97 The Network T ools functions are performed using a series of commands. Entering commands in Network T ools in volv es typing the command to be ex ecuted at the Network T ools prompt, adding any desired or required extensions, and pressing ENTER. There are two cate gories of commands in the c ...

  • Cabletron Systems 6H128-08 - page 144

    Chapter 5: Local Management 5-98 6H128-08 and 6H129-08 User’ s Guide 5.29.1 Built-In Commands The built-in commands listed in this section acti vate functions on the LM managed de vice or de vices being accessed through Network T ools. arp: Syntax: arp [options] Description: The arp command provides access to the ARP (Address Resolution Protocol) ...

  • Cabletron Systems 6H128-08 - page 145

    Network T ools 6H128-08 and 6H129-08 User’ s Guide 5-99 Example: bridge: Syntax: bridge [EN ABLE/DISABLE] [IFNUM/ALL] Description: The bridge command allo ws each bridge port to be enabled or disabled at the user’ s request, either one at a time or all at once. Specifying a single interface number will af fect the bridging status of that interf ...

  • Cabletron Systems 6H128-08 - page 146

    Chapter 5: Local Management 5-100 6H128-08 and 6H129-08 User’ s Guide defroute: Syntax: defroute [interface number] [IP address] Description: The defroute command allo ws the user to view , set or delete the default IP route to a managed de vice through the specified interface. Options: Not Applicable Example: netstat: Syntax: netstat [option] D ...

  • Cabletron Systems 6H128-08 - page 147

    Network T ools 6H128-08 and 6H129-08 User’ s Guide 5-101 Example: ping: Syntax: ping [IP address] Description: The ping command generates an outbound ping request to check the status (ali ve/not ali v e) of a de vice at a specified IP address. Options: Not Applicable Example : -> netstat -i Interface + Description # 1 (ethernet -csmacd) # 2 ( ...

  • Cabletron Systems 6H128-08 - page 148

    Chapter 5: Local Management 5-102 6H128-08 and 6H129-08 User’ s Guide reset: Syntax: reset Description: The reset command allo ws a soft reset of the de vice. The user will be queried to confirm the reset command to insure against unwanted resets. Options: Not Applicable Example: show: Syntax: sho w [PR O TOCOL] [T ABLE] Description : The sho w ...

  • Cabletron Systems 6H128-08 - page 149

    Network T ools 6H128-08 and 6H129-08 User’ s Guide 5-103 Example: traceroute: Syntax: traceroute [IP address] Description: The traceroute command generates a TRA CER OUTE request to a specified IP address and provides a display of all ne xt-hop routers in the path to the de vice. If the device is not reached, the command displays all next-hop ro ...

  • Cabletron Systems 6H128-08 - page 150

    Chapter 5: Local Management 5-104 6H128-08 and 6H129-08 User’ s Guide soft_reset: Syntax: soft_reset Description: This command restarts the software image, which restores the user configuration settings from NVRAM. The user will be queried to confirm the reset command to ensure against unwanted resets. Options: Not Applicable Example: t elnet: ...

  • Cabletron Systems 6H128-08 - page 151

    Network T ools 6H128-08 and 6H129-08 User’ s Guide 5-105 Example: link_trap: Syntax: link_trap [enable/disable/status] <POR T/all> Description: The link_trap command allo ws link traps to be enabled or disabled when specifying a single port, or simultaneously when specifying “all” or no ports. When one or all ports are specified to ena ...

  • Cabletron Systems 6H128-08 - page 152

    Chapter 5: Local Management 5-106 6H128-08 and 6H129-08 User’ s Guide 5.29.2 Special Commands done, quit, exit: Syntax: done Description: The done command enables the user to exit from Network T ools and return to the Main Menu screen. Options: Not Applicable Example: -> done 051472 ...

  • Cabletron Systems 6H128-08 - page 153

    6H128-08 and 6H129-08 User’ s Guide A-1 APPENDIX A SPECIFICATIONS This appendix provides operating specifications for the Cabletron Systems 6H128-08 and 6H129-08 Interface Modules. Cabletron Systems reserves the right to change these specifications at an y time without notice. A.1 DEVICE SPECIFICATIONS A.2 PHYSICAL PR OPER TIES A.3 EN VIRONMENT ...

  • Cabletron Systems 6H128-08 - page 154

    Appendix A: Specifications A-2 6H128-08 and 6H129-08 User’ s Guide A.4 INPUT/OUTPUT P OR TS 6H128-08 and 6H129-08 Specifications A.5 COM P OR T PINOUT ASSIGNMENTS The COM port is a serial communications port that supports Local Management or connection to a UPS. The COM port has the follo wing pin assignments: Ports 1 through 6 Fast Ethernet (1 ...

  • Cabletron Systems 6H128-08 - page 155

    Regulatory Compliance 6H128-08 and 6H129-08 User’ s Guide A-3 A.6 REGULATORY COMPLIANCE This equipment meets the follo wing safety and electromagnetic compatibility (EMC) requirements: Safety UL 1950, CSA C22.2 No. 950, EN 60950, IEC 950 and 73/23/EEC Electromagnetic Compatibility FCC Part 15, EN 50082-1, EN 55022, VCCI V -3, CSA C108.8, AS/NZS 3 ...

  • Cabletron Systems 6H128-08 - page 156

    Appendix A: Specifications A-4 6H128-08 and 6H129-08 User’ s Guide ...

  • Cabletron Systems 6H128-08 - page 157

    6H128-08 and 6H129-08 User’ s Guide B-1 APPENDIX B FE-100TX, FE-100FX AND FE-100F3 SPECIFICATIONS The 6H12X-08 supports three Fast Ethernet Interf ace Modules: • FE-100TX ( Section B.1 ) • FE-100FX ( Section B.2 ) • FE-100F3 ( Section B.3 ) This appendix provides the specifications for these modules. B.1 FE-100TX The slide switch on the FE ...

  • Cabletron Systems 6H128-08 - page 158

    Appendix B: FE-100TX, FE-100FX and FE-100F3 Specifications B-2 6H128-08 and 6H129-08 User’ s Guide B.1.1 A uto-Negotiation When using the optional FE-100TX Fast Ethernet Interf ace Modules, these twisted pair ports hav e the ability to auto-negotiate the type of connection required to provide a link to another de vice. During Auto-Negotiation, t ...

  • Cabletron Systems 6H128-08 - page 159

    FE-100FX 6H128-08 and 6H129-08 User’ s Guide B-3 B.2 FE-100FX The FE-100FX sho wn in Figure B-2 uses an SC style connector that supports multimode fiber optic cabling. Specifications for the FE-100FX are listed belo w . Figure B-2 FE-100FX Table B-1 Transmitter Power Cable T ype W orst Case Budget T ypical Budget 50/125 µm fiber 6.0 dB 9.0 dB ...

  • Cabletron Systems 6H128-08 - page 160

    Appendix B: FE-100TX, FE-100FX and FE-100F3 Specifications B-4 6H128-08 and 6H129-08 User’ s Guide B.3 FE-100F3 The FE-100F3 sho wn in Figure B-3 uses an SC style connector that supports single mode fiber optic cabling. Specifications for the FE-100F3 are listed in T able B-2 below . Figure B-3 FE-100F3 Table B-2 Transmitter Power Cable T ype ...

  • Cabletron Systems 6H128-08 - page 161

    6H128-08 and 6H129-08 User’ s Guide C-1 APPENDIX C OPTIONAL INSTALLATIONS AND MODE SWITCH BANK SETTINGS This appendix cov ers the follo wing items: • Required tools ( Section C.1 ) • Locations, functions, and settings for the mode switches ( Section C.2 ) • Installing optional Fast Ethernet Interf ace Modules ( Section C.3 ) C.1 REQUIRED T ...

  • Cabletron Systems 6H128-08 - page 162

    Appendix C: Optional Installations and Mode Switch Bank Settings C-2 6H128-08 and 6H129-08 User’ s Guide Figure C-1 sho ws the location of the mode switches and the switch settings for normal operation. Figure C-1 6H12X-08 Mode Switch Location/Component La yout Switch definitions and positions are as follo ws: • Switches 1 through 4 – For Ca ...

  • Cabletron Systems 6H128-08 - page 163

    Setting the Mode Switch 6H128-08 and 6H129-08 User’ s Guide C-3 • Switch 7 – Clear NVRAM. Changing the position of this switch resets NVRAM on either the next po wer up or the next operation of the front panel RESET switch. ALL user entered parameters, such as IP addresses, subnet masks, SNMP traps, and switching functions are restored to the ...

  • Cabletron Systems 6H128-08 - page 164

    Appendix C: Optional Installations and Mode Switch Bank Settings C-4 6H128-08 and 6H129-08 User’ s Guide C.3 INSTALLING OPTIONAL FAST ETHERNET INTERFACE MODULES Figure C-2 sho ws the location of the Fast Ethernet Interf ace Module connectors on the 6H12X-08 board for port slots 7 and 8. Figure C-2 Fast Ethernet Interface Module Connector Location ...

  • Cabletron Systems 6H128-08 - page 165

    Installing Optional Fast Ethernet Interface Modules 6H128-08 and 6H129-08 User’ s Guide C-5 T o install a Fast Ethernet Interface Module in port slot 7 or 8 of the 6H12X-08, proceed as follo ws: 1. Remove the coverplate from the port slot where the Fast Ethernet Interface Module will be installed. To remove a coverplate, refer to Figure C-3 and p ...

  • Cabletron Systems 6H128-08 - page 166

    Appendix C: Optional Installations and Mode Switch Bank Settings C-6 6H128-08 and 6H129-08 User’ s Guide Figure C-3 Coverplate Remo v al 2. Remove the screw from the rear standoff. Save the screw. 3. See Figure C-4 . Gently pull the faceplate of the 6H12X-08 forward to allow room for the Fast Ethernet Interface Modules to be aligned over the conn ...

  • Cabletron Systems 6H128-08 - page 167

    Installing Optional Fast Ethernet Interface Modules 6H128-08 and 6H129-08 User’ s Guide C-7 4. Carefully lower the Fast Ethernet Interface Module onto the standoffs while inserting the module connector into the associated motherboard connector. See Caution below. Figure C-4 Installing the Fast Ethernet Interface Module 5. Press down firmly on the ...

  • Cabletron Systems 6H128-08 - page 168

    Appendix C: Optional Installations and Mode Switch Bank Settings C-8 6H128-08 and 6H129-08 User’ s Guide ...

  • Cabletron Systems 6H128-08 - page 169

    6H128-08 and 6H129-08 User’ s Guide Index-1 INDEX Numerics 100BASE-FX cable length 2-2 10BASE-T connection 3-5, 3-8 802.1Q VLAN configuration 5-16 A Access policy 5-26, 5-58 B Broadcast Suppression Screen 5-82, 5-83 C Cable specifications 100BASE-FX MMF 2-2 100BASE-TX network 2-2 chassis date 5-18 Chassis Environmental Information Power Supply #X ...

  • Cabletron Systems 6H128-08 - page 170

    Index Index-2 6H128-08 and 6H129-08 User’ s Guide H Help 1-11 related manuals 1-12 I Installation Fast Ethernet Interface Module C-4 IP address 5-17, 5-41, 5-44 setting 5-20 IP Fragmentation 5-44 K Keyboard conventions 5-3 L LANVIEW LEDs 4-1 Local Management exiting 5-12 TELNET 5-4, 5-7 M MAC Address 5-17 Module Configuration Menu screen fields 5 ...

  • Cabletron Systems 6H128-08 - page 171

    Index 6H128-08 and 6H129-08 User’ s Guide Index-3 DRAM installed 5-73 Flash memory installed 5-73 NVRAM installed 5-73 peak switch utilization 5-74 reset peak switch utilization 5-74 T Trap table configuration 5-29, 5-61 Traps 5-29 Troubleshooting 4-1 checklist 4-6 U Uninterruptible Power Supply COM configuration for 5-7 connection of 5-7 Unpacki ...

  • Cabletron Systems 6H128-08 - page 172

    Index Index-4 6H128-08 and 6H129-08 User’ s Guide ...

Manufacturer Cabletron Systems Category Switch

Documents that we receive from a manufacturer of a Cabletron Systems 6H128-08 can be divided into several groups. They are, among others:
- Cabletron Systems technical drawings
- 6H128-08 manuals
- Cabletron Systems product data sheets
- information booklets
- or energy labels Cabletron Systems 6H128-08
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cabletron Systems 6H128-08.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cabletron Systems 6H128-08, service manual, brief instructions and user manuals Cabletron Systems 6H128-08. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cabletron Systems 6H128-08.

A complete manual for the device Cabletron Systems 6H128-08, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cabletron Systems 6H128-08 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cabletron Systems 6H128-08.

A complete Cabletron Systems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cabletron Systems 6H128-08 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cabletron Systems 6H128-08, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cabletron Systems 6H128-08, that we can find in the current document
3. Tips how to use the basic functions of the device Cabletron Systems 6H128-08 - which should help us in our first steps of using Cabletron Systems 6H128-08
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cabletron Systems 6H128-08
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cabletron Systems 6H128-08 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cabletron Systems 6H128-08?

Use the form below

If you did not solve your problem by using a manual Cabletron Systems 6H128-08, ask a question using the form below. If a user had a similar problem with Cabletron Systems 6H128-08 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)