    Operating and Installation Instr uctions V entilation System D A 249-4 T o pr event accidents and machine damage, read these instructions before installation or use. UV M.-Nr . 06 712 720 ...

  • Miele DA 249-4 - page 2

    2 ...

  • Miele DA 249-4 - page 3

    IMPORT ANT SAFETY INSTR UCTIONS Guide to the hood Functional description Operation T urning on the fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Selecting the power level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Delayed Shut Down . . . . . . ...

  • Miele DA 249-4 - page 4

    Read these Operating Instructions carefully bef ore installing or using the V entilation System. This appliance is intended for residential use only . Use the appliance only for its intended purpose. The manufacturer cannot be held responsible for damages caused by improper use of the hood. This appliance complies with current safety requir ements. ...

  • Miele DA 249-4 - page 5

    This equipment is not designed for maritime use or for use in mobile installations such as recr eational vehicles or aircraft. However , under certain conditions it may be possible for installation in these applications. Please contact the nearest Miele dealer or the T echnical Service Department with specific requir ements. Before servicing or cle ...

  • Miele DA 249-4 - page 6

    , W ARNING - T O REDUCE THE RISK OF A COOKT OP GREASE FIRE: Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers may ignite. Heat oils slowly on low or medium settings. Always turn the hood on when cooking at high heat or when cooking flaming foods. Clean ventilation fans frequently . Grease should no ...

  • Miele DA 249-4 - page 7

    Installation , W ARNING T o reduce the risk of fire only use metal ductwork. When installing the hood, follow the recommended minimum safety distances between a Miele cooktop and the hood: – 22" (55 cm) above electric cooktops, – 26" (65 cm) above gas cooktops, – 26" (65 cm) above an open grill. If local building codes requir e ...

  • Miele DA 249-4 - page 8

    Guide to the hood 8 ...

  • Miele DA 249-4 - page 9

    a Chimney e xtension b Recirculation vent For recir culation use with optional accessories c Chimney d Canopy e Overhead lighting f Active Charcoal Filter Available to pur chase, for use in the recir culation mode. g Grease filter h Decor cover i Light button This button turns the light on and off and also dims the light. The lighting can be used i ...

  • Miele DA 249-4 - page 10

    The hood offers two modes of operation: Air extraction The air is drawn in and cleaned by the decor panel and the grease filter and directed outside. The hood comes equipped with a non-return flap . This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur . When the hood is turned on, the ...

  • Miele DA 249-4 - page 11

    T urning on the fan ^ Press the On/Of f button. The fan runs at power level "2". The On/Off indicator lights. Selecting the power le vel ^ Use the " –/+ " controls to select the desired power level. + = increases the fan speed – = decreases the fan speed Level "1" to "3" (green indicators) ar e usually su ...

  • Miele DA 249-4 - page 12

    If the power level indicators "1" and "4" flash, the automatic switch back is not activated. ^ T o activate the automatic switch back press the "+" button. The power level indicators "1" and "4" light continuously . ^ T o deactivate the automatic switch back press the "–" button. ^ T o s ...

  • Miele DA 249-4 - page 13

    Delay ed Shut Down If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes. ^ Press the Delayed Shut Down button while the fan is still running. Press once = 5 minute delay (left indicator lights) Press twice = 15 minute ...

  • Miele DA 249-4 - page 14

    T urning the lighting on/off The overhead lighting can be turned on and off independently of the fan. ^ Press the light button briefl y to turn on the lighting. The light button indicator illuminates. ^ Press the light button briefl y again to turn off the lighting. The light button indicator will go out. Dimming the lighting The brightness of the ...

  • Miele DA 249-4 - page 15

    Filter timers Grease filter A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation. The grease filter must then be cleaned. After the grease filter have been cleaned and put in place, the grease filter timer must be reset. ^ T o do this, press the gr ease filter button for about 3 sec ...

  • Miele DA 249-4 - page 16

    Reprogramming the timer s The grease filter timer is pr eset to 30 hours. This time can be lengthened or shortened to 20, 30, 40 or 50 hours. – A time of 20 hours should be programmed in kitchens with frequent pan or deep frying. – A time of 20 hours should also be programmed if the kitchen is only used occasionally . Otherwise grease which has ...

  • Miele DA 249-4 - page 17

    Reprogramming the c harcoal filter timer The active charcoal filter can only be used in recir culation mode and can not be used to exhaust fumes. The charcoal filter timer is not not preset . Before using the hood in r ecirculation mode, the charcoal filter timer must be programmed. ^ T urn off the fan using the On/Off button. ^ Press the Delayed S ...

  • Miele DA 249-4 - page 18

    Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet or manually "tripping" the circuit breaker . Cleaning the casing W arning: Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. They will damage the surface. ^ All ...

  • Miele DA 249-4 - page 19

    Grease filter The decor panel and reusable metal grease filter r emove solid particles from the vented kitchen air (grease, dust, etc). The grease filter is visible when the decor cover is removed. The grease filter should be cleaned every 3 - 4 weeks or whenever the grease filter indicator lights. Always clean both the decor panel and the grease f ...

  • Miele DA 249-4 - page 20

    Cleaning the grease filters ^ By hand: use a scrub brush with a solution of warm water and mild detergent. Do not use the pure detergent, aggessive all purpose cleaners, oven sprays or limescale removers. They could destroy the filters. ^ In a dishwasher: place the filters vertically in the lower basket, making sure that the spray arm is not blocke ...

  • Miele DA 249-4 - page 21

    Active char coal filters In recir culation mode an active charcoal filter must be used in addition to the grease filter . The charcoal filter is designed to absorb cooking odors. Replacement active charcoal filters can be order ed from the Miele T echnical Service Department. U 1-800-999-1360 V 1-800-565-6435 ^ The decor cover must be removed to ac ...

  • Miele DA 249-4 - page 22

    Replace the active charcoal filter when the char coal filter indicator lights. Replace the filter at least every 6 months or when it no longer absorbs odors efficiently . The old charcoal filter can be disposed of in the household waste. ^ After replacing the char coal filters, press and hold the char coal filter button for about 3 seconds to reset ...

  • Miele DA 249-4 - page 23

    Changing the light bulbs Before changing the light bulbs, disconnect the hood from the power supply by either removing the fuse, unplugging it, or manually "tripping" the circuit br eaker . When in use halogen bulbs become extremely hot, and they can burn your hands. Do not attempt to change the bulbs until they have had sufficient time t ...

  • Miele DA 249-4 - page 24

    Repairs In the event of a fault which you cannot easily fix yourself, please contact the Miele T echnical Service Department at the address on the back of this booklet. ^ When contacting the T echnical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease f ...

  • Miele DA 249-4 - page 25

    Installation Instr uctions ...

  • Miele DA 249-4 - page 26

    26 ...

  • Miele DA 249-4 - page 27

    Disposal of packing material The cardboar d box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Please recycle. T o prevent suf focation of children, ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of their reach. Disposal of an old appliance ...

  • Miele DA 249-4 - page 28

    Installation accessories 28 ...

  • Miele DA 249-4 - page 29

    a 2 protective shields prevent scratches to the chimney during installation. b 2 hose clips for securing the ducting. c 1 reducing collar for use with 5" (125 mm) exhaust ducting. d Upper retaining plate secures the chimney extension. e Middle retaining plate for additional stability of the chimney . f Lower retaining plate secur es the canopy ...

  • Miele DA 249-4 - page 30

    The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the requir ed locations, a plywood backing (min. 1 / 2 " (13 mm) thick) spanning at least two studs must be installed. Failure to adequat ...

  • Miele DA 249-4 - page 31

    All electrical work should be perfor med by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufactur er can not be held responsible for unauthorized work. Ensure that power to the appliance is OFF while installation or repa ...

  • Miele DA 249-4 - page 32

    Appliance dimensions 32 ...

  • Miele DA 249-4 - page 33

    1) Air outlet installed upwards for recir culation mode 2) and 3) Cut out area in wall or ceiling for entrance of 6" (150 mm) ductwork or 5" (125 mm) ductwork with a reducing collar . For recir culation mode only 2) and outlet installation are necessary . Do not install this exhaust hood over cooktops burning solid fuel. When installing t ...

  • Miele DA 249-4 - page 34

    Installation instructions ^ See the enclosed installation instruction sheet. ^ Please read the "Important Safety Instructions" and Installation instructions before installing this hood. Protective film The casing is covered with a pr otective film to prevent scratching during transport. ^ Peel off the film befor e installing the casing pa ...

  • Miele DA 249-4 - page 35

    , W ARNING Danger of toxic fumes. Gas cooking appliances release carbon mono xide that can be harmful or fatal if inhaled. The exhaust gases extracted b y the hood should be vented outside of the building onl y . Do not terminate the exhaust ducts in attics, garages, crawlspaces, etc. T o reduce the risk of fire, onl y use metal ductwork. Please re ...

  • Miele DA 249-4 - page 36

    If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue. Never connect an exhaust hood to an active chimney , dryer vent, vent flue, or room venting ductwork. Seek professional advice befor e connecting an exhaust hood vent to an existing, inactive chimney or vent flue. Important! If the d ...

  • Miele DA 249-4 - page 37

    37 ...

  • Miele DA 249-4 - page 38

    38 ...

  • Miele DA 249-4 - page 39

    39 ...

  • Miele DA 249-4 - page 40

    M.-Nr . 06 712 720 / 00 e n-U S Alteration rights reserved / 1106 ...

Manufacturer Miele Category Ventilation Hood

Documents that we receive from a manufacturer of a Miele DA 249-4 can be divided into several groups. They are, among others:
- Miele technical drawings
- DA 249-4 manuals
- Miele product data sheets
- information booklets
- or energy labels Miele DA 249-4
All of them are important, but the most important information from the point of view of use of the device are in the user manual Miele DA 249-4.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Miele DA 249-4, service manual, brief instructions and user manuals Miele DA 249-4. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Miele DA 249-4.

Similar manuals

A complete manual for the device Miele DA 249-4, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Miele DA 249-4 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Miele DA 249-4.

A complete Miele manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Miele DA 249-4 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Miele DA 249-4, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Miele DA 249-4, that we can find in the current document
3. Tips how to use the basic functions of the device Miele DA 249-4 - which should help us in our first steps of using Miele DA 249-4
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Miele DA 249-4
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Miele DA 249-4 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Miele DA 249-4?

Use the form below

If you did not solve your problem by using a manual Miele DA 249-4, ask a question using the form below. If a user had a similar problem with Miele DA 249-4 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)