Manual APC C5

24 pages 1.27 mb
Download

Go to site of 24

Summary
  • APC C5 - page 1

    C T ype P o wer Filter Owner’ s Manual Models C5 and C5BLK ...

  • APC C5 - page 2

    ...

  • APC C5 - page 3

    i Safety Inf ormation 1. Read this manual - Read all of the safety and operating instructions before installing and operating this device. 2. Keep this manual - Retain this manual, and all of the safety infor mation that came with this device. 3. W arnings - Compl y with all warnings presented in this manual, as w ell as any found on the device. 4. ...

  • APC C5 - page 4

    ii Safety Inf ormation (continued) 14. Overloading - Do not o verload the wall outlet w here this de vice is bein g connected. Do not o verload this device. Ensure the total load to this de vice doe s not exceed that w hich is listed in the Specifications section of this manual. 15. Servicing - There are no user -ser viceable components within thi ...

  • APC C5 - page 5

    iii Registration V erification Confirmation By registering your purchase no w, it guarantees you will receive all the information and special offers y ou qualify for as the owner of this product. By registering your purchase no w, you have a way to confirm y ourself as the owner of the product in the event of fire, theft or loss. By registering y ...

  • APC C5 - page 6

    iv Class B Labeling and Instruction Manual Requirements De vices subject to Cer tification must be labeled with an FCC Identifier . De vices subject to V er ification or Cer tification must be labeled with the f ollowing compliance statement: This device complies with P ar t 15 of the FCC Rules. Operation is subject to the follo wing two condit ...

  • APC C5 - page 7

    v T able of Contents Safety Inf ormation i Protect Y our In vestment iii Class B Labeling and Instruction Manual Requirements vi Introduction 1 Prov en Exper tise…Prov en Reliability 1 Saf ety Precautions 2 P ackage Contents 2 Unit P ower Capacity 2 Features 3 Surge Protection 3 Isolated Noise Filter Banks (INFB) 3 10 Outlets 3 T op P anel 4 T op ...

  • APC C5 - page 8

    vi ...

  • APC C5 - page 9

    - 1 - Intr oduction Congratulations on your purchase of APC’ s C5 Po wer Filter (Figure 1). This unit will protect your high performance audio and video (A V) system from damaging po wer surges, spik es and lightning. Protection is guaranteed. Isolated noise filter banks will eliminate EMI/RFI as a source of audio and video signal degradation. D ...

  • APC C5 - page 10

    - 2 - Safety Pr ecautions Please ensure you hav e read and understand all of the safety information located at the front of this manual. If you hav e any questions about the safety information, or are concerned that your home may not be properly wired for this equipment, please contact APC T echnical Support or a qualified and licensed electrician ...

  • APC C5 - page 11

    - 3 - F eatures The follo wing are major features of the Model C5: Surge Pr otection The C5 Po wer Filter provides a high le vel of sur ge protection for the voltage going into the unit, thus protecting the de vices connected to the unit. Additionally , surge protected coax/radio frequency (RF) connectors are protected against sur ges trav eling ov ...

  • APC C5 - page 12

    - 4 - T op Panel The follo wing section describes the controls and indicators on the top panel. T op P anel Controls and Indicators The top panel controls and indicators for the C5 Po wer Filter are detailed in Figure 2. Each numbered callout refers to the numbered description found immediately belo w the picture. Figure 2. C5 Fr ont Panel Controls ...

  • APC C5 - page 13

    - 5 - Wiring OK Status Indicator When lit, the receptacle the C5 is plugged into is properly wired. If not lit, one of three wiring problems exists in the building wiring circuit: missing ground, o verloaded neutral, or re versed polarity . An electrician should be consulted to resolve the problem. Protection On Status Indicator When lit, the C5 is ...

  • APC C5 - page 14

    - 6 - Outlet Panel and Side P anel The follo wing section describes the functionality of the outlet and side panels. Outlet Panel The outlet panel for the C5 Po wer Filter is deteailed in Figure 3. Each numbered callout refers to the numbered description found in the fol- lo wing pages. Figure 3. C5 Outlet P anel 1 2 2 4 3 5 ...

  • APC C5 - page 15

    - 7 - A C-Po wered Outlets The C5 Po wer Filter provides for connection of up to ten (10) A C-powered de vices. The outlets are arranged according to the type of filtering protection provided for a gi ven applica- tion. These Isolated Noise Filter Banks eliminate electromag- netic and radio frequency interference (EMI/RFI) that can negati vely imp ...

  • APC C5 - page 16

    - 8 - Side Panel Contr ols and Indicators The side panel connectors for the C5 Po wer Filter are detailed in Figure 4. Each numbered callout refers to the numbered description found in the follo wing pages. Figure 4. C5 Side P anel Connectors 1 2 4 3 5 1 4 ...

  • APC C5 - page 17

    - 9 - Surge Pr otected CO AX/RF Connectors The C5 provides sur ge protection for your CA TV system, Cable Modem, DSS, or Antenna system. The sur ge protection feature pre vents sur ges trav eling ov er Coaxial data lines from damaging the system. Connect the coaxial cable from the CA TV or Cable Modem provider to the connector mark ed “IN. ” Co ...

  • APC C5 - page 18

    - 10 - Installation The installation of the C5 consists of the follo wing steps: 1. Make connections 2. Apply po wer Make Connections Prior to connecting equipment to the C5 Po wer Filter , ensure the unit is functional by connecting the A C Power Cord (pro vided) on the side panel ( , Figure 4). Once po wer is applied to the unit, and the unit is ...

  • APC C5 - page 19

    - 11 - T echnical Specifications The follo wing table contains the specifications for the C5 and C5BLK. Item Specification INPUT Input V oltage Range for Opera- tion (on utility) 92V - 140V Nominal V oltage 120 V ac Allo wable Input Frequenc y for Operation (on utility) 40 - 70 Hz Rated Input Current 15 Amps Input Circuit Break er Rating 15 Amps ...

  • APC C5 - page 20

    - 12 - F ederal Communications Commission (FCC) Compliance Inf ormation This de vice complies with Part 68 and P art 15 of the FCC rules. Operation is subject to the follo wing two conditions: (1) This device must not cause harmful interference, and (2) This de vice must accept any interference recei ved, including interference that may cause undes ...

  • APC C5 - page 21

    - 13 - T r oubleshooting This section describes possible causes and solutions for the follo wing problems: • Unit will not turn on. • “W iring OK Indicator” LED is not illuminated. Unit will not turn on. Probable Cause: Input po wer cord is not connected properly . Solution: Ensure supplied po wer cord is connected firmly to the wall outle ...

  • APC C5 - page 22

    - 14 - “Wiring OK Indicator” LED is not illuminated. Probable Cause: There are 3 reasons why this LED would not be illuminated: 1. Re versed polarity e xists at the wall outlet. 2. Neutral wire is ov erloaded. 3. Earth ground is missing at the wall outlet. Solution: Operating the unit under such conditions may impact its surge protection perfor ...

  • APC C5 - page 23

    - 15 - ...

  • APC C5 - page 24

    - 16 - 990-2377 Copyright © 2005 American P ower Con version All rights reserved. The APC A V logo is a registered trademark of American P ower Con version. All other trademarks are the property of their respective owner s. ...

Manufacturer APC Category Surge Protector

Documents that we receive from a manufacturer of a APC C5 can be divided into several groups. They are, among others:
- APC technical drawings
- C5 manuals
- APC product data sheets
- information booklets
- or energy labels APC C5
All of them are important, but the most important information from the point of view of use of the device are in the user manual APC C5.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals APC C5, service manual, brief instructions and user manuals APC C5. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product APC C5.

Similar manuals

A complete manual for the device APC C5, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use APC C5 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of APC C5.

A complete APC manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual APC C5 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the APC C5, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the APC C5, that we can find in the current document
3. Tips how to use the basic functions of the device APC C5 - which should help us in our first steps of using APC C5
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with APC C5
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of APC C5 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning APC C5?

Use the form below

If you did not solve your problem by using a manual APC C5, ask a question using the form below. If a user had a similar problem with APC C5 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)