Manual Sun Microsystems CP3000

72 pages 1.69 mb
Download

Go to site of 72

Summary
  • Sun Microsystems CP3000 - page 1

    Sun Microsystems, Inc. www .sun.com Submit comments about this document at: http://www.sun.com/hwdocs/feedback Sun Netra ™ CP3000 Adv anced Mezzanine Card PCIe Hard Dr iv e and SAS Controller User’ s Guide f or the AMC .1-HDD SAS Disk P ar t No . 820-7175-11 March 2010, Revision A ...

  • Sun Microsystems CP3000 - page 2

    Please Recycle Copyright © 2010 Sun Microsystems, Inc., 4150 Network Cir cle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun Microsystems, Inc. has intellectual pr operty rights relating to technology embodied in the product that is described in this document. In particular , and without limitation, these intellectual property righ ...

  • Sun Microsystems CP3000 - page 3

    iii Contents Preface vii 1. Getting Started 1–1 1.1 System Requirements 1–2 1.1.1 Operating Systems Compatibility 1–2 1.1.2 Chassis Compatibility 1–2 1.1.3 Blade Server Compatibility 1–2 1.1.4 Electrical and Environmental 1–3 1.2 Unpacking 1–3 1.3 Handling AMCs 1–4 1.4 AMC Faceplate 1–5 1.5 AMC LEDs 1–6 1.6 Removing and Installi ...

  • Sun Microsystems CP3000 - page 4

    iv Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.7 Enabling and Disabling SAS Ports 1–18 ▼ T o Enable AMC Port 2 (Driven by Port 1 of SAS Contr oller) 18 ▼ T o Enable AMC Port 3 (Driven by Port 2 of SAS Contr oller) 18 ▼ T o Disable AMC Port 2 (Driven by Port 1 of SAS Contr oller ...

  • Sun Microsystems CP3000 - page 5

    Contents v 4. Conf iguring the AMC 4–1 4.1 Configuration T ools 4–2 4.2 Boot BIOS Utility 4–2 4.2.1 Features and Conf igurations 4–3 4.2.2 Launching the Boot BIOS Utility 4–3 4.3 OpenBoot BIOS 4–5 4.4 Extensible Firmware Interface (EFI) BIOS 4–6 4.5 Enabling and Disabling Channel Ports 4–6 A. Connectors and Ports A–1 A.1 Connector ...

  • Sun Microsystems CP3000 - page 6

    vi Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 C.4.1 EN 55022 Emissions C–4 C.4.2 EN 55024 Immunity C–4 C.5 Regulatory Information C–5 C.5.1 FCC (USA) C–5 C.5.2 Industry Canada (Canada) C–5 Index Index–1 ...

  • Sun Microsystems CP3000 - page 7

    vii Pr eface The Netra™ CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User ’ s Guide describes the installation and configuration of the Sun Netra CP3000 AMC.1-HDD SAS disk. This guide also includes information about software, environment specif ications, connectors, and certifications. T ypographic Conventions Note – Char ...

  • Sun Microsystems CP3000 - page 8

    viii Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Related Documentation The following table lists the documentation for the AMC.1-HDD SAS disk. The online documentation is available at: http://docs.sun.com/app/docs/prod/cp3000.pcie#hic Thir d-Party W eb Sites Sun is not responsible for th ...

  • Sun Microsystems CP3000 - page 9

    Preface ix Sun W elcomes Y our Comments Sun is interested in impr oving its documentation and welcomes your comments and suggestions. Y ou can submit your comments by going to: http://www.sun.com/hwdocs/feedback Please include the title and part number of your document with your feedback: Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and ...

  • Sun Microsystems CP3000 - page 10

    x Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 ...

  • Sun Microsystems CP3000 - page 11

    1-1 CHAPTER 1 Getting Started This chapter provides information and procedur es needed to install and make the Sun Netra CP3000 AMC.1-HDD SAS disk operational. This chapter should be read before unpacking and installing the AMC. In addition to this chapter , refer to the following safety document: Important Safety Information for Sun Hardware Syste ...

  • Sun Microsystems CP3000 - page 12

    1-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.1 System Requir ements The following sections briefly describe the minimum system r equirements and the configurable featur es. Links are pr ovided to other chapters and appendixes containing more detailed information. 1.1.1 Operating Sys ...

  • Sun Microsystems CP3000 - page 13

    Chapter 1 Getting Star ted 1-3 1.1.4 Electrical and Envir onmental See Appendix B for electrical and environmental r equirements. Caution – None of the integrated chips junction temperature should exceed 125˚C. The AMC requir es air flow to meet this requirement. T esting should be done in the shelf to find the quantity of air f low needed. The ...

  • Sun Microsystems CP3000 - page 14

    1-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.3 Handling AMCs Caution – The system is sensitive to static electricity . T o prevent damage to the assembly , always connect an antistatic wrist strap between you and the system. A void touching areas of integrated circuitry . Static d ...

  • Sun Microsystems CP3000 - page 15

    Chapter 1 Getting Star ted 1-5 ■ Do not use an oscilloscope probe on the components. The soldered pins ar e easily damaged or shorted by the probe point. ■ T ransport an AMC in an antistatic bag. 1.4 AMC Faceplate The following shows the faceplate of the Sun Netra CP3000 AMC.1-HDD SAS disk. FIGURE 1-1 AMC.1-HDD SAS Disk Faceplate Note – The A ...

  • Sun Microsystems CP3000 - page 16

    1-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.5 AMC LEDs The following tables give status information for all of the LEDs on the AMC. T ABLE 1-1 describes the LEDs defined by A TCA to monitor board status. T ABLE 1-2 describes in detail the differ ent hot-swap BLUE LED states. T ABLE ...

  • Sun Microsystems CP3000 - page 17

    Chapter 1 Getting Star ted 1-7 Note – An AMC should be hot-swapped only when the LED is solid blue. T ABLE 1-2 Hot-Swap BLUE LED States Order Visible State State Description 1 Solid M1 FRU Inactive The Intelligent Platform Management Interface (IPMI) microcontr oller is booted, but the payload is not. The bottom latch is not fully closed or the a ...

  • Sun Microsystems CP3000 - page 18

    1-8 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1.6 Removing and Installing AMCs This section describes how to remove and install AMCs. The AMC.1-HDD SAS disk can be installed into an A TCA shelf (chassis) with sites that support AMC.1 PCI Express signaling. The site height must properly ...

  • Sun Microsystems CP3000 - page 19

    Chapter 1 Getting Star ted 1-9 Note – Depending on how the Shelf controls deactivation, the Shelf might not initiate deactivation when you disengage the ejector latch. If so, either conf igure the Shelf to allow deactivation via latch opening or deactivate by other methods. 4. For the AMC, initiate the hot-swap deactivation sequence by pulling th ...

  • Sun Microsystems CP3000 - page 20

    1-10 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 FIGURE 1-2 Deactivating the AMC Figure Legend 1 Fully In (IN) When IN, the module communicates to the shelf manager that the module is not in the hot-sw ap state, and the shelf manager communicates with the MMC . This position is for norma ...

  • Sun Microsystems CP3000 - page 21

    Chapter 1 Getting Star ted 1-11 7. Remove the AMC. FIGURE 1-3 Removing the AMC 8. Replace the AMC with another AMC ( FIGURE 1-7 ) or install a f iller panel. Note – Be sure to follow handling instructions. See Section 1.3, “Handling AMCs” on page 1-4 . ...

  • Sun Microsystems CP3000 - page 22

    1-12 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Caution – Failure to f ill all slots with AMCs or cover with filler panels can negatively impact the cooling of the system. 1.6.2 Removing a Blade Server and AMC Following are the instructions for r emoving a blade server and installed A ...

  • Sun Microsystems CP3000 - page 23

    Chapter 1 Getting Star ted 1-13 Note – Depending on how the Shelf controls deactivation, the Shelf might not initiate deactivation when you disengage the ejector latch. If so, either conf igure the Shelf to allow deactivation via latch opening or deactivate by other methods. 3. Disconnect all cables connected to the switch. 4. Loosen the two boar ...

  • Sun Microsystems CP3000 - page 24

    1-14 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 3. Obtain the AMC card from the ship kit. Note – Be sure to follow unpacking and handling instructions. See Section 1.2, “Unpacking” on page 1-3 and Section 1.3, “Handling AMCs” on page 1-4 . FIGURE 1-5 Sample T op V iew Note – ...

  • Sun Microsystems CP3000 - page 25

    Chapter 1 Getting Star ted 1-15 FIGURE 1-6 Opening the Injector/Ejector Latch Figure Legend 1 Fully In (IN) When IN, the module communicates to the shelf manager that the module is not in the hot-sw ap state, and the shelf manager communicates with the MMC . This position is for normal operation. 2 Half W ay (HW) When in the HW position, the hot-sw ...

  • Sun Microsystems CP3000 - page 26

    1-16 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 6. Carefully align the edges of the AMC with the guides in the appropriate site. It might be helpful to look into the enclosure to verify correct alignment of the rails in the guides. Caution – Do not force the AMC into the site. If it d ...

  • Sun Microsystems CP3000 - page 27

    Chapter 1 Getting Star ted 1-17 FIGURE 1-7 Inserting the AMC Into a Blade Server 8. Push the ejector latch in fully . If system power is on and AMC is installed properly , the AMC board Hot-Swap LED lights up. The Hot-Swap LED blinks for several seconds, then goes off. If the Hot-Swap LED does not go of f after several seconds, push firmly on the i ...

  • Sun Microsystems CP3000 - page 28

    1-18 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Caution – Failure to f ill all slots with AMCs or cover with filler panels can negatively impact the cooling of the system. 9. Power on the system, if necessary . Refer to your system manual for instructions on correctly powering on the ...

  • Sun Microsystems CP3000 - page 29

    Chapter 1 Getting Star ted 1-19 Note – This utility has many other uses and adjustable values. Parameter adjustments are permanently committed to flash memory , and affect futur e behavior of the AMC. Only advanced users who fully understand the technical implications should modify parameters. A full description of parameters and functions is in ...

  • Sun Microsystems CP3000 - page 30

    1-20 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 ...

  • Sun Microsystems CP3000 - page 31

    2-1 CHAPTER 2 Overview This chapter introduces the key featur es of the AMC. This chapter includes a product def inition, a list of product features, and functional block diagrams with brief descriptions. This chapter can be used to compare the features of the AMC against the needs of a specific application. This chapter contains the following topi ...

  • Sun Microsystems CP3000 - page 32

    2-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 2.1 Featur es Part of Sun’s A TCA platform, the Sun Netra CP3000 AMC.1-HDD SAS disk complies with PICMG 3.0 AdvancedTCA Specification R2.0 ECN002 and the following specifications: ■ PICMG AMC.0 Rev . 2.0 ■ AMC.1 Revision 1, PCI Expres ...

  • Sun Microsystems CP3000 - page 33

    Chapter 2 Overview 2-3 ■ Support for SA T A, as defined in the Serial A T A Specification, version 1.0a. 2.2 Key Components The following figur e and sections describe key components of the Sun Netra CP3000 AMC.1-HDD SAS disk. FIGURE 2-1 T op-Level AMC Layout 2.2.1 Har d Drive Disk The Sun Netra CP3000 AMC.1-HDD SAS disk provides a single SAS har ...

  • Sun Microsystems CP3000 - page 34

    2-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 2.2.3 SAS Contr oller The AMC.1-HDD SAS disk incorporates a PCIe-to-SAS host controller manufactured by LSI Corporation, device model LSI-SAS1064E. The controller provides host access to SAS and SA T A disks. The controller features four la ...

  • Sun Microsystems CP3000 - page 35

    Chapter 2 Overview 2-5 ■ e-Keying as described in the AMC.0 specification ■ FRU information ■ LED indicators for hot-swap and OOS (out of service) 2.2.6 Port Connectors The AMC includes connectors to communicate with the host board and take its interfaces outside the A TCA chassis. Refer to Appendix A for complete connector descriptions and p ...

  • Sun Microsystems CP3000 - page 36

    2-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 Figure Legend Indicator Color State Description and Function 1 OOS Red On Out of Service: fault set by shelf manager , or 12V payload po wer not detected. Off No module f ault. 12V payload po wer is being supplied to board. 2 OK Green On Mo ...

  • Sun Microsystems CP3000 - page 37

    Chapter 2 Overview 2-7 2.4 Functional Diagram FIGURE 2-3 AMC SAS-HDD Functional Block Diagram 2.5 T echnical Support and W arranty If you have any technical questions or support issues that are not addressed in the Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Contr oller documentation set or on the web site, contact your local S ...

  • Sun Microsystems CP3000 - page 38

    2-8 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 When you call Sun Services, indicate if the Sun Netra CP3000 AMC.1-HDD SAS disk was purchased separately and is not associated with a system. Have the proper AMC identification information ready . Be prepared to give the r epresentative the ...

  • Sun Microsystems CP3000 - page 39

    Chapter 2 Overview 2-9 FIGURE 2-4 Sun Netra CP3000 AMC.1-HDD SAS disk Barcode Labeling Figure Legend 1 Final Assembly Number: • Assembly process label, wher e xxx denotes disk drive capacity • Rzz = Assembly Revision (Refer to Bill Of Material) wher e zz is a numeric revision 2 Sub-Assembly Number: • P/N = sub assembly Part Number 600-05101x ...

  • Sun Microsystems CP3000 - page 40

    2-10 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 2.7 Disposal The AMC might contain materials that require r egulation upon disposal. Please dispose of this product in accor dance with local rules and regulations. For disposal or recycling information, please contact your local authoriti ...

  • Sun Microsystems CP3000 - page 41

    3-1 CHAPTER 3 Managing the AMC This chapter describes the AMC management software. The Sun Netra CP3000 AMC.1-HDD SAS disk includes an IPMI-based Module Management Controller (MMC) that meets all requir ements set out in the PICMG AMC.0 specification. The MMC allows detection of the module by the carrier board and manages communication between the ...

  • Sun Microsystems CP3000 - page 42

    3-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 3.1 Monitoring and Contr ol Functions The MMC is responsible for communicating module status information to the carrier board, and also has some contr ol at the module level. The 10GbE local PHY is held in reset until the AMC Carrier IPMI u ...

  • Sun Microsystems CP3000 - page 43

    Chapter 3 Managing the AMC 3-3 Get Device SDR 29.3 S/E 21h Mandatory Reserve Device SDR Repository 29.4 S/E 22h Mandatory Get Sensor Reading Factors 29.5 S/E 23h Optional Set Sensor Hysteresis 29.6 S/E 24h Optional Get Sensor Hysteresis 29.7 S/E 25h Optional Set Sensor Threshold 29.8 S/E 26h Optional Get Sensor Threshold 29.9 S/E 27h Optional Set S ...

  • Sun Microsystems CP3000 - page 44

    3-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 3.3 FRU Information Board information such as serial number , date of manufacture, OEM name, part number , and so on is retrievable from the FRU EEPROM integrated into the MMC. FRU information stored onboar d the AMC.1-HDD SAS disk complies ...

  • Sun Microsystems CP3000 - page 45

    Chapter 3 Managing the AMC 3-5 3.4 Sensors The AMC.1-HDD SAS disk module management is connected to sensors monitoring key board voltages and temperatur es. Data recor ds from the following sensors ar e accessible using IPMI commands: ■ Hot-swap ■ +12V payload power ■ +3.3V management power ■ Board and inlet temperatur e ■ +1.2V onboard v ...

  • Sun Microsystems CP3000 - page 46

    3-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 3.5 Firmwar e and Software Upgrades For up-to-date instructions on upgrading the firmwar e and software, r efer to the following documentation: ■ Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller Product Notes (8 ...

  • Sun Microsystems CP3000 - page 47

    4-1 CHAPTER 4 Conf iguring the AMC This chapter describes how to configur e the AMC using the SAS Boot BIOS Configuration Utility , the OpenBoot ™ BIOS, and the Extensible Firmware Interface (EFI) Boot Services Driver . This chapter contains the following topics: ■ Section 4.1, “Configuration T ools” on page 4-2 ■ Section 4.2, “Boot BIO ...

  • Sun Microsystems CP3000 - page 48

    4-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 4.1 Conf iguration T ools The configuration tools ar e preloaded on a f lash ROM device embedded on the AMC. A MicroTCA or host carrier CPU can r ead the code to facilitate booting from SAS drives. The BIOS contains an embedded configuratio ...

  • Sun Microsystems CP3000 - page 49

    Chapter 4 Configuring the AMC 4-3 4.2.1 Featur es and Conf igurations The Boot BIOS supports the following: ■ Using multiple AMC.1 SAS modules ■ Applying global properties stored in f lash ■ Selecting and configur e up to 256 adapters ■ Automatic INT13 drive mapping for SAS drives ■ SAS topology discovery , including expander traversal ? ...

  • Sun Microsystems CP3000 - page 50

    4-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 FIGURE 4-1 Boot BIOS Main Menu The menu displays a scrolling list of all the AMC SAS modules visible in the system, with PCI Express (PCIe) identif ication information. 3. Use the arrow keys to highlight the AMC module you want to conf igur ...

  • Sun Microsystems CP3000 - page 51

    Chapter 4 Configuring the AMC 4-5 FIGURE 4-2 Adapter Properties Menu 5. Using the arrow keys, select the item of interest. 6. Press ENTER to display the next screen. 4.3 OpenBoot BIOS For information about the OpenBoot BIOS, refer to the Sun Solaris OS and SP ARC documentation. The documentation is available at the following site: http://www.sun.co ...

  • Sun Microsystems CP3000 - page 52

    4-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 4.4 Extensible Firmwar e Interface (EFI) BIOS The AMC.1-HDD SAS disk includes an EFI boot services driver for use with A TCA blades that feature Intel® IA64 processors. Additional information is available at http://www.lsi.com . 4.5 Enabli ...

  • Sun Microsystems CP3000 - page 53

    A-1 APPENDIX A Connectors and Ports This appendix describes the connectors and ports you can use to communicate with the host board and application-specific devices. A brief description of each connector and port is given, and a detailed description and pinout given for each connector . This appendix contains the following topics: ■ Section A.1, ...

  • Sun Microsystems CP3000 - page 54

    A-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 A.1 Connector Locations and Assignments This module is AMC.1 and AMC.3 compliant and can use ports 2 and 3, as defined in the AMC.3 specification. A.2 Connector Pinouts The AMC.1-HDD SAS disk includes an AMC connector , which conforms to th ...

  • Sun Microsystems CP3000 - page 55

    Appendix A Connectors and P or ts A-3 9 12V 54 'PCIe_RX1_N' 99 No Connect 144 No Connect 10 GND 55 GND 100 No Connect 145 No Connect 1 1 No Connect 56 'IPMI_SCL_L' 101 GND 146 GND 12 No Connect 57 12V 102 No Connect 147 No Connect 13 GND 58 GND 103 No Connect 148 No Connect 14 No Connect 59 'PCIe_TX2_P' 104 GND 149 GND ...

  • Sun Microsystems CP3000 - page 56

    A-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 A.3 SAS Contr oller Ports The AMC.1-HDD SAS disk incorporates four dedicated SAS controller ports as follows. These SAS ports are shipped with PHY’s disabled and are not driving AMC ports 2 and 3. This default configura- tion avoids incom ...

  • Sun Microsystems CP3000 - page 57

    Appendix A Connectors and P or ts A-5 A.4 e-Keying Ports The AMC.1-HDD SAS disk connects up to two SAS ports on the AMC connector . These ports are def ined by the AMC.3 specification for serial storage. The module designates four PCI Express ports, per AMC.1 specif ication. The link type and link type extension are def ined in the following table. ...

  • Sun Microsystems CP3000 - page 58

    A-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 ...

  • Sun Microsystems CP3000 - page 59

    B-1 APPENDIX B Envir onment Specifications This appendix describes the electrical, environmental, and mechanical specifications. It includes illustrations of the board dimensions. This appendix contains the following topics: ■ Section B.1, “Electrical and Envir onmental” on page B-2 ■ Section B.2, “Reliability” on page B-4 ■ Section B ...

  • Sun Microsystems CP3000 - page 60

    B-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 B.1 Electrical and Envir onmental The following sections provide tables and illustrations showing the electrical and environmental specif ications. B.1.1 Electrical The AMC.1-HDD SAS disk shall consume no more than the following fr om the s ...

  • Sun Microsystems CP3000 - page 61

    Appendix B Environment Specifications B-3 V ibration Operating 1 G (20 to 300 Hz) Nonoperating 5 G (20 to 300 Hz) Shock Operating 100 G/1ms duration Nonoperating 400 G/1ms duration Altitude Operating –1,000 to +10,000 feet Nonoperating –1,000 to +40,000 feet Performance RPM 10,025 rpm Seek time avg Read/write 4.5 m/s (typical) Seek time max Rea ...

  • Sun Microsystems CP3000 - page 62

    B-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 B.1.3 Absolute Maximum Ratings The following values are str ess ratings only . Do not operate at these maximums. See Section B.1.4, “Normal Operating Ranges” on page B-4 for normal operating conditions. B.1.4 Normal Operating Ranges *Th ...

  • Sun Microsystems CP3000 - page 63

    Appendix B Environment Specifications B-5 B.3 Mechanical This section includes the mechanical specifications for dimensions and weight. The AMC.1-HDD SAS disk meets the PICMG 3.0 AdvancedTCA Specification R2.0 ECN002 and AMC.0 R2.0 for all mechanical parameters. B.3.1 Board Dimensions and W eight The AMC.1-HDD SAS disk is 181.5 mm by 73.5mm and con ...

  • Sun Microsystems CP3000 - page 64

    B-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 ...

  • Sun Microsystems CP3000 - page 65

    C-1 APPENDIX C Agency Certif ications This appendix lists standards agencies and the certif ications related to the Sun Netra CP3000 AMC.1-HDD SAS disk. This product was tested in an EMC-compliant chassis and meets the r equirements for EN55022 Class A equipment. Compliance was achieved under the following conditions: ■ Conductive chassis rails c ...

  • Sun Microsystems CP3000 - page 66

    C-2 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 C.1 CE Certif ication The Sun Netra CP3000 AMC.1-HDD SAS disk meets the intent of Directive 89/336/EEC for Electromagnetic Compatibility [EN55024:1998, EN55022:2006] and Low-V oltage Directive 73/23/EEC for Product Safety [EN60950-1:2001]. ...

  • Sun Microsystems CP3000 - page 67

    Appendix C Agency Cer tifications C-3 C.3 Safety ■ UL/cUL 60950--1 Safety for Information T echnology Equipment (UL File #E138926) ■ EN/IEC 60950-1:2001, 1 ST ED CB/CCA –scheme, Safety for Information T echnology Equipment (TUV CB certificate and r eport) The following group and/or national deviations were consider ed: ■ CENELEC Common Modi ...

  • Sun Microsystems CP3000 - page 68

    C-4 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 C.4 Emissions T est Regulations ■ FCC Part 15, Subpart B Class A Commercial Equipment ■ Industry Canada ICES-003:2004 Class A Commercial Equipment ■ CISPR 22/EN 55022:2006 Class A Radiated, Power line Conducted ■ VCCI, Japanese V -3 ...

  • Sun Microsystems CP3000 - page 69

    Appendix C Agency Cer tifications C-5 C.5 Regulatory Information Caution – If you make any modification to the AMC not expr essly approved by Sun, you could void your warranty and/or regulatory authority to operate the component. C.5.1 FCC (USA) This product has been tested and found to comply with the limits for a Class A digital device pursuant ...

  • Sun Microsystems CP3000 - page 70

    C-6 Sun Netra CP3000 Advanced Mezzanine Card PCIe Hard Drive and SAS Controller User’s Guide • March 2010 1. Ce dispositif peut ne pas causer l'interférence nocive. 2. Ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée. ...

  • Sun Microsystems CP3000 - page 71

    Index-1 Index Numerics 10GbE local PHY, 3-2 A absolute maximum ratings, B-4 AMC flexing, preventing, 1-4 antistatic bag, 1-3 B board status, 1-6 board voltages, monitoring, 2-4 C cable management bracket lowering, 1-12 cable management bracket, lowering, 1-12 certification, C-2 comments, about this book, ix connector locations, A-2 D deactivating ...

  • Sun Microsystems CP3000 - page 72

    Index-2 Sun Netra CP3000 Adv anced Mezzanine Card PCIe Hard Drive and SAS Controller User’ s Guide • March M MAC address label, 2-8 management voltage, B-4 maximum power consumption, B-4 Module Management Controller (MMC), 2-4, 3-1 module status, 3-2 N NEBS/ETSI, C-2 nominal operating voltage, B-4 noncondensing relative humidity, B-4 normal ope ...

Manufacturer Sun Microsystems Category Computer Drive

Documents that we receive from a manufacturer of a Sun Microsystems CP3000 can be divided into several groups. They are, among others:
- Sun Microsystems technical drawings
- CP3000 manuals
- Sun Microsystems product data sheets
- information booklets
- or energy labels Sun Microsystems CP3000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sun Microsystems CP3000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sun Microsystems CP3000, service manual, brief instructions and user manuals Sun Microsystems CP3000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sun Microsystems CP3000.

A complete manual for the device Sun Microsystems CP3000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sun Microsystems CP3000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sun Microsystems CP3000.

A complete Sun Microsystems manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sun Microsystems CP3000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sun Microsystems CP3000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sun Microsystems CP3000, that we can find in the current document
3. Tips how to use the basic functions of the device Sun Microsystems CP3000 - which should help us in our first steps of using Sun Microsystems CP3000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sun Microsystems CP3000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sun Microsystems CP3000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sun Microsystems CP3000?

Use the form below

If you did not solve your problem by using a manual Sun Microsystems CP3000, ask a question using the form below. If a user had a similar problem with Sun Microsystems CP3000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)