  • Westinghouse UL-ES-TurboSwirl-WH05 - page 1

    UL-ES-T urboSwirl-WH05 OWNER'S MANUAL MANUAL DEL USUARIO MR N.W . : 5.2 KGS G.W . : 5.7 KGS T urbo Swirl TM Please write model number here for future reference: / Por favor , incluya el número del modelo aquí para futura referencia: UL_TurboSwirl 1/18/05 12:15 PM Page 1 ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 2

    2 UL-ES-T urboSwirl-WH05 1. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFPA 70-1996), including fire-rated construction. 2. Use this unit only in the manner intended by the manufacturer . If you have any questions contact the manufacturer . 3. After making ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 3

    3 UL-ES-T urboSwirl-WH05 1. El trabajo de instalación y el cableado eléctrico los deben efectuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFPA 70-1996), incluyendo las de incendio. 2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante. 3. Desp ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 4

    4 UL-ES-T urboSwirl-WH05 FEA TURES CARACTERÍSTICAS DOWNROD INST ALLATION INST ALACIÓN CON V ARILLA VERTICAL For normal ceilings Para cielorrasos normales V AUL TED CEILING INST ALLATION INST ALACIÓN PARA CIELORRASOS ABOVEDADOS May require a longer downrod (sold separately) Podría requerir una varilla vertical más larga (se vende por separado) ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 5

    5 UL-ES-T urboSwirl-WH05 Unpack and inspect fan carefully to be certain all contents are included. Tu rn off power at fuse box to avoid possible electrical shock. 1 Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structura ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 6

    6 UL-ES-T urboSwirl-WH05 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE 3 Remove the screws and star washers from the two mating holes (1) on the canopy . Loosen (do not remove) the screws in the mating slots (2) on the canopy . Rotate the mounting bracket counter -clockwise and remove from the canopy . Quite los tornillos y ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 7

    7 UL-ES-T urboSwirl-WH05 MOUNTING BRACKET INST ALLA TION INST ALACIÓN CON SOPOR TE DE MONT AJE Install mounting bracket to outlet box in ceiling using the screws and washers provided with the outlet box. Instale el soporte de montaje a la caja de embutir del cielorraso con la tornillería suministrada con la caja de embutir . 4 5 MOUNTING OPTIONS ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 8

    8 8 UL-ES-T urboSwirl-WH05 FLUSH MOUNT OPTION OPCIÓN DE INST ALACIÓN AL RAS 6 Guide motor wires through the base of the canopy as shown and attach canopy directly to top of motor housing with flush mount screws and lock washers provided. Tighten screws securely . Deslice los cables del motor a través de la base del dosel como se indica y fije el ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 9

    9 UL-ES-T urboSwirl-WH05 8 2 1 3 Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in yoke. PROCEED TO ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 10

    10 UL-ES-T urboSwirl-WH05 EXTENDED DOWNROD OPTION OPCIÓN CON V ARILLA VER TICAL MÁS LARGA 10 Slide downrod ball (1) off of downrod and remove pin (2). Deslice la esfera de la varilla vertical (1) hasta separarla de la varilla vertical y quite el pasador (2). 2 1 11 Re-install pin into extended downrod, and slide downrod ball up to the top of the ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 11

    11 UL-ES-T urboSwirl-WH05 12 Feed motor lead wires through downrod/canopy assembly and insert downrod into downrod yoke. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yoke and downrod. Insert clamp pin (2) into cross pin until it snaps into place. Tighten set screws (3) in yoke. Pase los hilos ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 12

    12 UL-ES-T urboSwirl-WH05 MOUNTING MONT AJE 14 With bracket holding fan assembly , make electrical connections using the following step for wiring instructions. Con la pieza de montaje sujetando el conjunto del ventilador , haga las conexiones eléctricas de acuerdo a las siguientes instrucciones de cableado. 13 1 2 Carefully lift fan assembly onto ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 13

    13 UL-ES-T urboSwirl-WH05 WIRING OPTIONS OPCIÓN DE CABLEADO 16 White (common) Black (hot) Blue* (hot) Main (ground) White (common) Fan Switch (hot) Light Switch (hot) Green (ground) From Fan: From House: (connect) (connect) (connect) (connect) *Attach blue wire only if attaching light kit with fan. Wall Control Follow diagram above to make wiring ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 14

    14 UL-ES-T urboSwirl-WH05 The canopy has two mating slots (1) and two mating holes (2). Position both slots on canopy directly under and in line with two screws in the mounting bracket (3). Lift the canopy , allowing the two screws and star wahers to slide into the mating slots. Rotate the canopy clockwise until both screws from the mounting bracke ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 15

    15 UL-ES-T urboSwirl-WH05 A. B. Attach motor pads to blade holders by pushing or threading screws first through the blade holders, then through pads (inset A). The pads will hold the motor screws in place during installation. Attach blade assembly to motor using the noise dampening motor gaskets and motor screws and locking washers provided. Tighte ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 16

    16 UL-ES-T urboSwirl-WH05 LIGHT FIXTURE INST ALLA TION INST ALACIÓN DEL AR TEF ACTO LUMINOSO Install bulb (60 watt max., not included). Instale la lámpara (60 vatios máx, no incluida). 20 21 Attach glass to light fixture by inserting neck of glass into light fixture, keeping two spring clips inside the neck of the glass. Pull the glass shade tow ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 17

    17 UL-ES-T urboSwirl-WH05 Assemble decorative fob and extension chains from hardware bag to fan pull chains by inserting end of chain into chain coupling. Confirm chains are held by lightly pulling both chains in coupling. Sujetar las cadenas largas de tiro con las piezas finales correspondientes, a las cadenas del ventilador , introduciendo el ext ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 18

    18 UL-ES-T urboSwirl-WH05 Operation Tu rn on the power and check operation of fan. The pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool weather depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls directio ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 19

    19 UL-ES-T urboSwirl-WH05 Operación Encienda el ventilador y verifique su funcionamiento. La cadenilla de tiro controla las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado. Las velocidades para clima cálido o frío dependen de factores como el tamaño de la habit ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 20

    20 UL-ES-T urboSwirl-WH05 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly , installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this T rouble Shooting Chart. If a problem cannot be remedied, p ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 21

    21 UL-ES-T urboSwirl-WH05 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado, instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar probl ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 22

    22 UL-ES-T urboSwirl-WH05 UL_TurboSwirl 1/18/05 12:15 PM Page 22 ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 23

    23 UL-ES-T urboSwirl-WH05 PA RT S LIST LIST A DE REPUESTOS # Description 1 . . . . . . . . . . . . . . . . . Mounting Bracket 2 . . . . . . . . . . . . . . . . . Blade Bracket 3 . . . . . . . . . . . . . . . . . Blade 4 . . . . . . . . . . . . . . . . . Glass 5 . . . . . . . . . . . . . . . . . Fan Speed Switch 6 . . . . . . . . . . . . . . . . . L ...

  • Westinghouse UL-ES-TurboSwirl-WH05 - page 24

    UL-ES-T urboSwirl-WH05 W estinghouse Lighting Corporation 12401 McNulty Road Philadelphia, P A 19154 U.S.A. W estinghouse Lighting Corporation, a Westinghouse Electric Corporation licensee is a registered trademark of W estinghouse Electric Corporation Made in China © 2005 W estinghouse Lighting Corporation W estinghouse Lighting Corporation 12401 ...

Manufacturer Westinghouse Category Outdoor Ceiling Fan

Documents that we receive from a manufacturer of a Westinghouse UL-ES-TurboSwirl-WH05 can be divided into several groups. They are, among others:
- Westinghouse technical drawings
- UL-ES-TurboSwirl-WH05 manuals
- Westinghouse product data sheets
- information booklets
- or energy labels Westinghouse UL-ES-TurboSwirl-WH05
All of them are important, but the most important information from the point of view of use of the device are in the user manual Westinghouse UL-ES-TurboSwirl-WH05.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Westinghouse UL-ES-TurboSwirl-WH05, service manual, brief instructions and user manuals Westinghouse UL-ES-TurboSwirl-WH05. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Westinghouse UL-ES-TurboSwirl-WH05.

A complete manual for the device Westinghouse UL-ES-TurboSwirl-WH05, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Westinghouse UL-ES-TurboSwirl-WH05 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Westinghouse UL-ES-TurboSwirl-WH05.

A complete Westinghouse manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Westinghouse UL-ES-TurboSwirl-WH05 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Westinghouse UL-ES-TurboSwirl-WH05, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Westinghouse UL-ES-TurboSwirl-WH05, that we can find in the current document
3. Tips how to use the basic functions of the device Westinghouse UL-ES-TurboSwirl-WH05 - which should help us in our first steps of using Westinghouse UL-ES-TurboSwirl-WH05
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Westinghouse UL-ES-TurboSwirl-WH05
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Westinghouse UL-ES-TurboSwirl-WH05 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Westinghouse UL-ES-TurboSwirl-WH05?

Use the form below

If you did not solve your problem by using a manual Westinghouse UL-ES-TurboSwirl-WH05, ask a question using the form below. If a user had a similar problem with Westinghouse UL-ES-TurboSwirl-WH05 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)