Manual Lincoln Electric RANGER 9 SVM 110-A

134 pages 1.43 mb
Download

Go to site of 134

Summary
  • Lincoln Electric RANGER 9 SVM 110-A - page 1

    SVM 110-A January , 1996 Safety Depends on Y ou Lincoln arc welding and cutting equipment is designed and built with safety in mind. However , your overall safety can be increased by pr oper installation . . . and thoughtful operation on your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WITHOUT READ- ING THIS MANUAL AND THE SAFETY PREC ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 2

    SAFETY i i FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ____________________________________ ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 3

    SAFETY ii ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 4

    SAFETY iii iii FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer ’s recommendations. 8.c. Ground the equipment in accordance with the U.S. Nati ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 5

    SAFETY iv iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L ’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 6

    v v RANGER 9 RANGER 9 Page Safet y .................................................................................................................................................i-iv Installatio n ............................................................................................................................ . Section A Installation S ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 7

    T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 RANGER 9 RANGER 9 Installation T echnical Specifications .............................................................................................................A-2 Safety Precautions ........................................................................................... ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 8

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-2 A-2 RANGER 9 RANGER 9 TECHNICAL SPECIFICA TIONS - RANGER 9 INPUT - GASOLINE ENGINE Manufacturer Description Speed Displacement Ignition Capacities Onan 2 cyl., ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 9

    Read this entire installation section before you start installation. SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly r ead all the operation and maintenance manuals supplied with your machine. They include important safety precautions; detailed engine starting, operating, and maintenance instructions; and parts lis ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 10

    ST ACKING RANGER 9 machines CANNOT be stacked. TIL TING Place the machine on a secure, level surface whenev- er you use it or store it. Any surfaces you place it on other than the ground must be firm, non-skid, and structurally sound. The gasoline engine is designed to run in a level posi- tion for best performance. It can operate at an angle, but ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 11

    MUFFLER RELOCA TION Shut off the machine and allow the muf fler to cool before touching the muf fler . The RANGER 9 is shipped with the exhaust coming out on the left side. It can be changed to the right side by removing two scr ews that hold the exhaust port cover in place and installing the cover on the opposite side. NOTE: Operating the RANGER 9 ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 12

    WELDING CABLE CONNECTIONS CABLE SIZE AND LENGTH Be sure to use welding cables that ar e large enough. The correct size and length becomes especially impor- tant when you are welding at a distance fr om the welder . T able A.1 lists recommended cable sizes and lengths for rated current and duty cycle. Length r efers to the distance from the welder t ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 13

    When the RANGER 9 is mounted on a truck or a trailer , the machine generator ground stud MUST be secur ely connect- ed to the metal frame of the vehicle. See Figure A.1. The gr ound stud is marked with the ground symbol. If the RANGER 9 is connected to premises wiring such as a home or shop, it must be properly connected to the system earth ground. ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 14

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-8 A-8 RANGER 9 RANGER 9 LOAD 230 V olt 60 Hz. 3-Wire Ser vice 230 V OL T GROUNDED CONDUCT OR 115 V OL T 115 V OL T PO WER COMP ANY METER DOUBLE POLE DOUBLE THRO ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 15

    Section B-1 Section B-1 RANGER 9 RANGER 9 T ABLE OF CONTENTS - OPERA TION SECTION - Operation ............................................................................................................................... Section B Safety Instructions .................................................................................................. ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 16

    OPERA TING INSTRUCTIONS Read and understand this entire section befor e oper- ating your RANGER 9. SAFETY INSTRUCTIONS Do not attempt to use this equipment until you have thoroughly r ead all the operation and maintenance manuals supplied with your machine. They include important safety precautions; detailed engine starting, operating, and maintena ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 17

    RECOMMENDED APPLICA TIONS WELDER The RANGER 9 provides excellent constant current AC/DC welding output for stick (SMA W) welding and for TIG welding, and it offers constant voltage output for DC semiautomatic wire feed welding. For mor e details on using the machine as a welder , see WELD- ING OPERA TION in the Operation section of this manual. GEN ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 18

    • Quiet engine muf fler with reversible exhaust feature for right or left side. • All copper alternator windings and high quality insu- lation for dependable long life. • Automatic engine shutdown protection for low oil pressur e. • Automatic engine idler goes to low idle 10 to 14 seconds after welding for greater fuel economy; includes hig ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 19

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-5 B-5 RANGER 9 RANGER 9 AC DC+ DC- LINCOLN ELECTRIC RANGER 9 W ARNING RANGE 175 125 90 70 50 16 to 25 225 AC 210 DC 1 2 3 4 5 10 max 9 8 7 6 3 2 1 7 8 CHOKE AUTO HIG ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 20

    7. 20 AMP , 115 VOL T DUPLEX RECEPT ACLES: Connection point for supplying 115 volt power to operate one or two electrical devices. 8. 50 AMP , 230 VOL T RECEPT ACLE: Connection point for supplying 230 volt power to operate one electrical device. 9. WELD OUTPUT TERMINAL (TO WORK) WITH FLANGE NUT : Provides the connection point for the work cable. 10 ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 21

    GASOLINE ENGINE CONTROLS See Figure B.2 for the location of the following fea- tures: 1. ENGINE CHOKE CONTROL: Provides a richer air/fuel mixture for cold engine starting conditions. See the topic ENGINE OPERA TION, below , for details on setting the choke. 2. IDLER CONTROL SWITCH: Adjusts the running speed of the engine. The switch has two positio ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 22

    BEFORE ST ARTING THE ENGINE Check and fill the engine oil level: 1. Be sure the machine is on a level surface. 2. Remove the engine oil dipstick and wipe it with a clean cloth. Reinsert the dipstick and check the level on the dipstick. On the Onan engine, the oil fill cap and dipstick are a unit. See Figur e D.1 in the Maintenance section of this m ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 23

    OPERA TION B-9 B-9 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE B.1 TYPICAL RANGER 9 FUEL CONSUMPTION ONAN P218 PERFORMER Low Idle – No Load, 2150 RPM .40 Gallons/hour (1.5 liters/hour) High Idle ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 24

    WELDING OPERA TION GENERAL INFORMA TION • Do not touch electrically live parts or elec- trodes with your skin or wet clothing. • Do not breathe welding fumes or gases. • Use ventilation or exhaust to remove welding fumes from the br eathing area. • Keep flammable material away . • W ear eye, ear , and body protection. The RANGER 9 can del ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 25

    T o Use the RANGER 9 for AC/DC TIG (Constant Current) Welding: 1. Connect the K930-1 TIG Module to the RANGER 9. Follow the installation instructions provided with the kit. Also be sure to follow the special machine grounding instructions given in the man- ual. 2. Refer to the instruction manual with the TIG mod- ule (IM 528) for operation with a R ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 26

    T o Use the RANGER 9 for DC Wire Feed Welding (Constant V oltage): 1. Connect one of the following: the LN-25, LN-7, LN-8, or LN-742 Wire Feeder . Follow the installa- tion instructions in the ACCESSORIES section of this manual. 2. Some recommended Innershield electrodes are: NR-211MP , NR-311, NR-203 series, as well as Lincore ® 33 and 55 har dfa ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 27

    SUMMAR Y OF WELDING PROCESSES AND MACHINE SETTINGS T able B.3 summarizes the requir ements for various welding processes you can perform with the RANGER 9. OPERA TION B-13 B-13 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Retu ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 28

    AUXILIAR Y POWER Be sure that any electrical equipment plugged into the generator AC power receptacles can withstand a ±10% voltage and a ±3% frequency variation. GENERAL INFORMA TION The RANGER 9 generator is rated at 9000 continuous watts. It provides both 115 volt and 230 volt power . Y ou can draw up to 80 amps total from the 115 volt recepta ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 29

    OPERA TION B-15 B-15 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE B.5 - SIMUL T ANEOUS WELDING AND AUXILIAR Y POWER Output Selector Welding Permissible Power in W atts Permissible Auxiliary Current ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 30

    T ABLE B.6 TYPICAL GENERA TOR POWER APPLICA TIONS Suggested Power Applications Running W atts *Start-up Watts *Air Compressor - 3/4 HP 1,250 3,100 - 5,000 *Airless Sprayer - 1/3 HP 600 1,500 - 2,400 Chain Saw 1,200 Circular Saw 1,200 Coffee Maker 1,000 *Deep Freezer 500 750 - 2,000 *Electric Motor - 1 HP 1,000 2,500 - 4,000 Electric Range (1 elemen ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 31

    T ABLE OF CONTENTS - ACCESSORIES - Accessories ........................................................................................................................... Section C Options/Accessories...................................................................................................................C-2 TIG W elding .................. ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 32

    OPTIONS/ACCESSORIES The following options/accessories are available for your RANGER 9 from your local Lincoln Distributor . T wo-Wheel T railer (K768-2) – For in-plant or yard towing of the RANGER 9. (Not intended for highway towing as equipped. For highway use of this trailer , consult applicable federal, state, and local laws about possible req ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 33

    TIG WELDING TIG Module (K930-1) - The TIG Module is an acces- sory that provides high fr equency and shielding gas control for AC and DC GT AW (TIG) welding applica- tions. It provides contactor contr ol of constant curr ent welding power sources having an internal contactor . The K930-1 TIG Module is supplied without accessories. Arc Start switche ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 34

    ELECTRIC SHOCK can kill. • Do not operate with panels open. • Disconnect NEGA TIVE (-) BA TTER Y LEAD before servicing. • Do not touch electrically live parts. MOVING P ARTS can injure. • Keep guards in place. • Keep away from moving parts. • Only qualified personnel should install, use or service this equipment. CONNECTION OF THE RANGE ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 35

    7. Place the WELDING TERMINALS switch in the “REMOTEL Y CONTROLLED” position. 8. Adjust wire feed speed at the wir e feeder and set the welding voltage with the output “CONTROL” to a CV (constant voltage) position at the welder . NOTE: If optional remote control is used, place the output control switch in the “CON- TROL REMOTE” position ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 36

    CONNECTION OF THE LN-25 TO THE RANGER 9 WITH 42 VOL T REMOTE OUTPUT CONTROL MODULE (SEE FIGURE C.3.) 1. Shut the welder off. 2. Connect the electrode cable from the K626-XX Input Cable Assembly to the “ELECTRODE” termi- nal of the welder and to the LN-25 wire feeder . Connect the work cable to the “TO WORK” termi- nal of the welder . NOTE: ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 37

    ACCESSORIES C-7 C-7 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-7 TO THE RANGER 9 USING K584 INPUT CABLE ASSEMBL Y (SEE FIGURE C.4.) NOTE: If your LN-7 comes equipped with a K291 or K ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 38

    ACCESSORIES C-8 C-8 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-7 TO THE RANGER 9 USING K867 UNIVERSAL ADAPTER (SEE FIGURE C.5.) 1. Shut the welder off. 2. Connect the electrode cable ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 39

    ACCESSORIES C-9 C-9 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-8 TO THE RANGER 9 (SEE FIGURE C.6.) 1. Shut the welder off. 2. Connect the electrode cable from the LN-8 to the “ELEC ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 40

    ACCESSORIES C-10 C-10 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE LN-742 TO THE RANGER 9 (SEE FIGURE C.7.) 1. Shut the welder off. 2. Connect the electrode cable fr om the LN-742 to the ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 41

    ACCESSORIES C-11 C-11 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC CONNECTION OF THE K488 SG CON- TROL MODULE AND K487 MAGNUM SPOOL GUN TO THE RANGER 9 (SEE FIGURE C.8.) 1. Shut the welder off. 2. Connect ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 42

    Section D-1 Section D-1 RANGER 9 RANGER 9 T ABLE OF CONTENTS -MAINTENANCE- Maintenance ......................................................................................................................... Section D Safety Precautions................................................................................................................. ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 43

    SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • T ur n the engine off before working inside the machine. • Remove guar ds only when necessary to perform maintenance and replace them when the mainte- nance requiring their r emoval is complete. • If guards ar e missing from the machine, get r eplac ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 44

    CHANGE THE OIL FIL TER Change the oil filter the first time after 25 hours of operation. Then, under normal operating conditions, change the oil filter after every other oil change. If the engine is operated under heavy load or in high ambi- ent temperatures, change the oil filter mor e frequently . See T able D.3 for recommended maintenance inter- ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 45

    AIR CLEANER : Y our air cleaner may have only the paper element, or it may have the cartridge and a foam preclean- er . If it has the precleaner , service the element every 50 hours and the pre- cleaner every 25 hours. If the air cleaner doesn’t have the precleaner , service the element every 25 hours. Under dusty conditions, service more often. ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 46

    CRANKCASE BREA THER: The Onan engine is equipped with a crankcase breather that pr events pressur e from building up inside the crankcase, pre- vents moisture contamination fr om moisture, gasoline vapors, or combustion vapors. If the breather valve becomes sticky , it can cause oil leaks, oil consump- tion, rough idle, r educed power , and sludge ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 47

    MAINTENANCE D-6 D-6 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE D.2 ONAN ENGINE MAINTENANCE SCHEDULE FREQUENCY MAINTENANCE REQUIRED Daily or Before Starting Engine • Fill fuel tank. • Check oil ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 48

    BA TTER Y MAINTENANCE GASES FROM BA TTERY can explode. • Keep sparks, flame, and cigarettes away from battery . T o prevent EXPLOSION when: • INST ALLING A NEW BA TTER Y - Disconnect the negative cable from the old battery first and connect to the new battery last. • CONNECTING A BA TTER Y CHARGER - Remove the battery from the welder by disco ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 49

    T o reinstall the brushes, pr ess them upward and slide a cable tie or wooden stick through the brush holder tabs. See Figure D.4. Install the brush holder into position and secure with the scr ews previously removed. Remove the cable tie or wooden stick and the brushes will seat onto the slip rings. RECEPT ACLES: Keep the electrical receptacles in ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 50

    MAINTENANCE D-9 D-9 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE D.6 - MAJOR COMPONENT LOCA TIONS 7 8 12 9 10 11 1 2 3 4 5 6 1. OUTPUT TERMINALS (LOCA TION) 2. ENGINE CONTROLS 3. AUXILIAR Y POWER RE ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 51

    Section E-1 Section E-1 RANGER 9 RANGER 9 Theory of Operation ............................................................................................................. Section E Battery , Starter , Engine, Rotor , Stator , and Idler Solenoid ...................................................................................................E-2 R ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 52

    BA TTER Y , ST ARTER, ENGINE, ROTOR, ST A TOR, AND IDLER SOLENOID The 12VDC battery powers the starter motor . When the engine is started and running, the battery circuit voltage is fed, through the printed cir cuit board, to the rotating field coil in the r otor via a brush and slip ring configuration. This excitation (“flashing”) voltage mag- ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 53

    ROTOR FIELD FEEDBACK, AUXILIAR Y , AND WIRE FEEDER POWER The AC voltage developed in the field winding is fed to the full wave field bridge. The DC output of the bridge is filtered by the field capacitor and contr olled by the printed circuit boar d according to the output contr ol setting. This filtered and contr olled voltage is fed to the rotor ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 54

    WELD WINDING, REACTOR, AND RANGE SWITCH The stator weld winding is connected to the reactor and range switch. The inductance in the reactor of fers an impedance to current flow . The reactor coil is tapped at various points. As the range switch is ro- tated, differ ent amounts of reactor coil ar e brought into the current path. As mor e tur ns of r ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 55

    OUTPUT BRIDGE, CHOKE, POLARITY SWITCH, AND OUTPUT TERMINALS The AC voltage developed in the stator weld winding is delivered, thr ough the reactor and range switch, to the output bridge and polarity switch. Depending upon the setting of the polarity switch, either AC volt- age or DC voltage is delivered thr ough the output con- tactor , which is ac ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 56

    Section F-1 Section F-1 RANGER 9 RANGER 9 T roubleshooting & Repair Section ................................................................................. Section F How to Use T roubleshooting Guide ......................................................................................F-2 PC Board T roubleshooting Pr ocedures ................ ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 57

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC HOW TO USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory T rained Personnel. Unauthorized repairs performed on this equipment may ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 58

    ELECTRIC SHOCK can kill. Have an electrician install and service this equipment. T ur n the machine OFF before working on equipment. Do not touch electrically hot parts. Sometimes machine failures appear to be due to PC board failur es. These problems can sometimes be traced to poor electrical connections. T o avoid prob- lems when troubleshooting ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 59

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-4 F-4 RANGER 9 RANGER 9 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 60

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-5 F-5 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 61

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-6 F-6 RANGER 9 RANGER 9 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 62

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-7 F-7 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 63

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-8 F-8 RANGER 9 RANGER 9 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 64

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-9 F-9 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 65

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-10 F-10 RANGER 9 RANGER 9 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 66

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-11 F-11 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 67

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-12 F-12 RANGER 9 RANGER 9 TROUBLESHOOTING & REP AIR TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 68

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-13 F-13 RANGER 9 RANGER 9 Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE A ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 69

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-14 F-14 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE A ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 70

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-15 F-15 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE A ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 71

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-16 F-16 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE A ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 72

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-17 F-17 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE A ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 73

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-18 F-18 RANGER 9 RANGER 9 TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE A ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 74

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-19 F-19 RANGER 9 RANGER 9 ROTOR VOL T AGE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthor ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 75

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-20 F-20 RANGER 9 RANGER 9 ROTOR VOL T AGE TEST (continued) FIGURE F .1 - LOCA TION OF LEAD 200A AND 219 FOR ROTOR VOL T AGE TEST Lead #219A Lead #200A TROUBLESHOOTING & REP ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 76

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ROTOR RESIST ANCE TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may r esult in ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 77

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-22 F-22 RANGER 9 RANGER 9 ROTOR RESIST ANCE TEST (continued) FIGURE F .2 – LOCA TION OF ROTOR SLIP RINGS TEST PROCEDURE 1. With the 5/16” nut ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 78

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-23 F-23 RANGER 9 RANGER 9 13. Measure the r esistance to ground. A. Set the ohmmeter on the high scale (X100,000). B. Place one pr obe on either o ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 79

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-24 F-24 RANGER 9 RANGER 9 W ARNING AUXILIAR Y AND FIELD WINDING TEST Service and repair should be performed by only Lincoln Electric factory train ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 80

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-25 F-25 RANGER 9 RANGER 9 AUXILIAR Y AND FIELD WINDING TEST (continued) FIGURE F .3 – LOCA TION OF LEADS #3 AND #5 Lead #3 Lead #5 1 15V Recepta ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 81

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-26 F-26 RANGER 9 RANGER 9 AUXILIAR Y AND FIELD WINDING TEST (continued) Retaining Ta b Field Bridge Rectifier 7 9 Capacitor 201 201A 200 200A 200B ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 82

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-27 F-27 RANGER 9 RANGER 9 AUXILIAR Y AND FIELD WINDING TEST (continued) Z W Y X K B I H N L C D M G E F J A FIGURE F .4A - 14 PIN AMPHENOL PIN ASS ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 83

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-28 F-28 RANGER 9 RANGER 9 AUXILIAR Y AND FIELD WINDING TEST (continued) If the voltage readings ar e within specifica- tions, then the windings ar ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 84

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-29 F-29 RANGER 9 RANGER 9 W ARNING OUTPUT RECTIFIER BRIDGE TEST Service and repair should be performed by only Lincoln Electric factory trained pe ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 85

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-30 F-30 RANGER 9 RANGER 9 OUTPUT RECTIFIER BRIDGE TEST (continued) FIGURE F .5 – LOCA TION OF OUTPUT RECTIFIER LEADS Ohmmeter Probes + Pigtail D ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 86

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-31 F-31 RANGER 9 RANGER 9 W ARNING CHARGING CIRCUIT TEST Service and repair should be performed by only Lincoln Electric factory trained personnel ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 87

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-32 F-32 RANGER 9 RANGER 9 CHARGING CIRCUIT TEST (continued) FIGURE F .6 – LOCA TION OF VOL T AGE REGULA TOR A C Lead DC Lead A C Lead V oltage R ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 88

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-33 F-33 RANGER 9 RANGER 9 W ARNING ENGINE THROTTLE ADJUSTMENT TEST Service and repair should be performed by only Lincoln Electric factory trained ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 89

    TROUBLESHOOTING & REP AIR F-34 F-34 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ENGINE THROTTLE ADJUSTMENT TEST (continued) FIGURE F .7 – BLOWER P ADDLE MARKED FOR STROBE-T ACH METHOD Blow er P addl ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 90

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-35 F-35 RANGER 9 RANGER 9 ENGINE THROTTLE ADJUSTMENT TEST (continued) Thro ttle Linkage Choke Cable 3/8" High Idle Adjus tment Nut Housing So ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 91

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-36 F-36 RANGER 9 RANGER 9 ENGINE THROTTLE ADJUSTMENT TEST (continued) Oscilloscope Method: 1. Connect the oscilloscope to the 115 V AC receptacle, ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 92

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-37 F-37 RANGER 9 RANGER 9 This is the typical auxiliary output voltage generated from a pr operly operating machine. Note that each vertical divis ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 93

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-38 F-38 RANGER 9 RANGER 9 This is the typical CV output voltage generated from a pr operly operating machine. Note that each vertical division rep ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 94

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-39 F-39 RANGER 9 RANGER 9 This is the typical DC output voltage generated from a pr operly operating machine. Note that each vertical division rep ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 95

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-40 F-40 RANGER 9 RANGER 9 This is the typical AC output voltage generated from a pr operly operating machine. Note that each vertical division rep ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 96

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-41 F-41 RANGER 9 RANGER 9 This is NOT the typical DC (+) output voltage waveform. One output diode is not functioning. Note the “gap” in the w ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 97

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-42 F-42 RANGER 9 RANGER 9 This is NOT the typical CV output voltage waveform. The capacitor bank is not functioning. Note the “ripple” in the ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 98

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-43 F-43 RANGER 9 RANGER 9 This is the typical CV output voltage generated from a pr operly operating machine. Note that each vertical division rep ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 99

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-44 F-44 RANGER 9 RANGER 9 SCOPE SETTINGS V olts/Div .....................50V/Div . Horizontal Sweep.....5 ms/Div . Coupling ...................... ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 100

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-45 F-45 RANGER 9 RANGER 9 CH1 0 volts 5 ms 50 volts SCOPE SETTINGS V olts/Div .....................50V/Div . Horizontal Sweep.....5 ms/Div . Coupl ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 101

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-46 F-46 RANGER 9 RANGER 9 BRUSH REMOV AL AND REPLACEMENT W ARNING Service and repair should be performed by only Lincoln Electric factory trained ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 102

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-47 F-47 RANGER 9 RANGER 9 BRUSH REMOV AL AND REPLACEMENT (continued) PROCEDURE 1. Remove the spark plug wir es. 2. With the 5/16” nut driver , r ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 103

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-48 F-48 RANGER 9 RANGER 9 SLIP RINGS A slight amount of darkening and wear of the slip rings and brushes is normal. Brushes should be inspected wh ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 104

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-49 F-49 RANGER 9 RANGER 9 W ARNING FIELD CAP ACITOR AND/OR RECTIFIER BRIDGE REMOV AL AND REPLACEMENT Service and repair should be performed by onl ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 105

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-50 F-50 RANGER 9 RANGER 9 FIELD CAP ACITOR AND/OR RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) FIGURE F .11 RECTIFIER BRIDGE LOCA TION AN ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 106

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-51 F-51 RANGER 9 RANGER 9 FIELD CAP ACITOR AND/OR RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) PROCEDURE - RECTIFIER BRIDGE REMOV AL AND ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 107

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-52 F-52 RANGER 9 RANGER 9 W ARNING PRINTED CIRCUIT BOARD REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 108

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-53 F-53 RANGER 9 RANGER 9 PRINTED CIRCUIT BOARD REMOV AL AND REPLACEMENT (continued) FIGURE F .12 - PRINTED CIRCUIT BOARD LOCA TION Curren t Senso ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 109

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-54 F-54 RANGER 9 RANGER 9 12. With the 1/4” nut driver , remove five screws holding the printed cir cuit board. 13. Replace the old printed cir ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 110

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-55 F-55 RANGER 9 RANGER 9 W ARNING OUTPUT RECTIFIER BRIDGE REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electri ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 111

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-56 F-56 RANGER 9 RANGER 9 OUTPUT RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) FIGURE F .13 - OUTPUT RECTIFIER CONNECTIONS Mounting Sc rew ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 112

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-57 F-57 RANGER 9 RANGER 9 OUTPUT RECTIFIER BRIDGE REMOV AL AND REPLACEMENT (continued) 12. With the 3/8” wrench and slot head scr ew driver , re ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 113

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-58 F-58 RANGER 9 RANGER 9 W ARNING OUTPUT CAP ACITOR REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric fact ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 114

    TROUBLESHOOTING & REP AIR F-59 F-59 RANGER 9 RANGER 9 Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OUTPUT CAP ACITOR REMOV AL AND REPLACEMENT (continued) FIGURE F .14 - OUTPUT CAP ACITOR BANK/PRINTED CIRCUIT BOARD LOCA ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 115

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-60 F-60 RANGER 9 RANGER 9 OUTPUT CAP ACITOR REMOV AL AND REPLACEMENT (continued) Be sure to follow the r ecommended static-free methods for handli ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 116

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-61 F-61 RANGER 9 RANGER 9 W ARNING OUTPUT CONT ACTOR REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric fact ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 117

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-62 F-62 RANGER 9 RANGER 9 OUTPUT CONT ACTOR REMOV AL AND REPLACEMENT (continued) FIGURE F .15 – OUTPUT CONT ACTOR LOCA TION 4 2 3 1 5 4 PROCEDUR ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 118

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIRs F-63 F-63 RANGER 9 RANGER 9 OUTPUT CONT ACTOR REMOV AL AND REPLACEMENT (continued) FIGURE F .16 – CONT ACTOR COIL LEAD PLACEMENT Leads #224 Heavy ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 119

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-64 F-64 RANGER 9 RANGER 9 W ARNING ENGINE/ROTOR REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory t ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 120

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-65 F-65 RANGER 9 RANGER 9 ENGINE/ROTOR REMOV AL AND REPLACEMENT (continued) FIGURE F .17 – COMPONENT LOCA TIONS, ENGINE/ROTOR REMOV AL 5 3 6 1 9 ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 121

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-66 F-66 RANGER 9 RANGER 9 ENGINE/ROTOR REMOV AL AND REPLACEMENT (continued) ENGINE AND ROTOR REMOV AL PROCEDURE 1. Refer to Figure F .17 for compo ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 122

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-67 F-67 RANGER 9 RANGER 9 ROTOR REMOV AL PROCEDURE 1. T o remove the rotor , double check that the engine spark plug wires ar e disconnect- ed. Y ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 123

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-68 F-68 RANGER 9 RANGER 9 REASSEMBL Y PROCEDURE NOTE: Lincoln Electric recommends that a new bearing (Lincoln part #M9300-85) be installed when yo ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 124

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-69 F-69 RANGER 9 RANGER 9 RETEST AFTER REP AIR Retest a machine: • If it is rejected under test for any r eason that requir es you to remove any ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 125

    Section G-1 Section G-1 RANGER 9 RANGER 9 Diagrams Section ............................................................................................................ Section G Wiring Diagram RANGER 9 Onan (Code 9975) ....................................................................G-2 Wiring Diagram RANGER 9 Onan CSA (Code 9976) .............. ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 126

    DIAGRAMS G-2 G-2 RANGER 9 RANGER 9 236 ELECTRODE WORK 241 GND (+) D1 (-) R1 C2 25W 100 C3 C4 C5 224E AMMETER 209 AM 1 AUTO HIGH 3 5 6 212 CAPACITOR AC AC B+ 208 } STARTER REGULATOR (+) (-) 200A 219 200 SR (+) (-) ROTOR FIELD (+) (-) (+) (-) C1 800 MFD CV- CV+ DC+ DC- AC 212 (CAVITY #1) 208 (CAVITY #3) +- + - D2 (-) (+) CR1 209 AC AC LOCATING 31 32 ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 127

    DIAGRAMS G-3 G-3 236 ELECTRODE WORK 241 GND (+) D1 (-) R1 C2 25W 100 C3 C4 C5 224E AMMETER 209 AM 1 AUTO HIGH 3 5 6 212 CAPACITOR AC AC B+ 208 } STARTER REGULATOR (+) (-) CV- CV+ DC+ DC- AC 212 (CAVITY #1) 208 (CAVITY #3) +- + - CR1 209 LOCATING 31 32 42 9 7 PC BOARD PCB1 1 6 12 1 J1 J2 4 5 8 CURRENT SENSOR 75A AMPHENOL 2 1 4 5 8 1 1 3 4 6 2 3 4 J3 ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 128

    DIAGRAMS G-4 G-4 77 9061 L 2C 475 R52 242 247 4.75K R47 1400V .0047 C9 5W 10V DZ1 224E 240 236 235 250 76 232 COM COM +12V COM +10V COM COM COM COM COM +10V +10V LAST CHANGE 5A NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY RESISTORS = Ohms ( ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 129

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC DIAGRAMS G-5 G-5 RANGER 9 RANGER 9 AND IS NOT TO BE REPRODUCED, DISCLOSED OR USED WITHOUT THE EXPRESS PERMISSION OF 1400V .0047 C4 J4 6 J5 6 J5 1 J3 3 J4 3 J5 3 J5 8 J5 7 J3 4 J4 ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 130

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC DIAGRAMS G-6 G-6 RANGER 9 RANGER 9 30.00 9.31 CENTER OF GRAVITY WITH OIL IN ENGINE AND FULL FUEL TANK. 9.29 21.21 26.59 30.28 C 20.51 L OF SHAFT 42.00 30.00 FOR OIL FILTER REMOVA ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 131

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC DIAGRAMS G-7 G-7 RANGER 9 RANGER 9 NOTE: Lincoln Electric assumes no responsibility for liabilities resulting from board level troubleshooting. PC Board repairs will invalidate y ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 132

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC DIAGRAMS G-8 G-8 RANGER 9 RANGER 9 NOTE: Lincoln Electric assumes no responsibility for liabilities resulting from board level troubleshooting. PC Board repairs will invalidate y ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 133

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC DIAGRAMS G-9 G-9 RANGER 9 RANGER 9 J3 J4 J5 C1 C2 C3 C4 J3 RF BYPASS J4 J5 M16675 NOTE: Lincoln Electric assumes no responsibility for liabilities resulting from board level trou ...

  • Lincoln Electric RANGER 9 SVM 110-A - page 134

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC DIAGRAMS G-10 G-10 RANGER 9 RANGER 9 NOTE: Lincoln Electric assumes no responsibility for liabilities resulting from board level troubleshooting. PC Board repairs will invalidate ...

Manufacturer Lincoln Electric Category Welder

Documents that we receive from a manufacturer of a Lincoln Electric RANGER 9 SVM 110-A can be divided into several groups. They are, among others:
- Lincoln Electric technical drawings
- RANGER 9 SVM 110-A manuals
- Lincoln Electric product data sheets
- information booklets
- or energy labels Lincoln Electric RANGER 9 SVM 110-A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lincoln Electric RANGER 9 SVM 110-A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lincoln Electric RANGER 9 SVM 110-A, service manual, brief instructions and user manuals Lincoln Electric RANGER 9 SVM 110-A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lincoln Electric RANGER 9 SVM 110-A.

A complete manual for the device Lincoln Electric RANGER 9 SVM 110-A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lincoln Electric RANGER 9 SVM 110-A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lincoln Electric RANGER 9 SVM 110-A.

A complete Lincoln Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lincoln Electric RANGER 9 SVM 110-A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lincoln Electric RANGER 9 SVM 110-A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lincoln Electric RANGER 9 SVM 110-A, that we can find in the current document
3. Tips how to use the basic functions of the device Lincoln Electric RANGER 9 SVM 110-A - which should help us in our first steps of using Lincoln Electric RANGER 9 SVM 110-A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lincoln Electric RANGER 9 SVM 110-A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lincoln Electric RANGER 9 SVM 110-A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lincoln Electric RANGER 9 SVM 110-A?

Use the form below

If you did not solve your problem by using a manual Lincoln Electric RANGER 9 SVM 110-A, ask a question using the form below. If a user had a similar problem with Lincoln Electric RANGER 9 SVM 110-A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)