  • Intel SE8500 - page 1

    User ’ s Guide for Server Configuration Wizard (SCW) Utility For Intel ® Server Boards and Platforms based on the SE72xx, SE7320, SE75xx, and SE8500 Chipsets Revision 1 .1 for Server Configuration Wizard through v 2.1.6 Part Number: D17937-002 ...

  • Intel SE8500 - page 2

    Disclaimers Copyright ©2001-2005 Intel Corporatio n. All Rights Reserved. No part of this publication may be reproduce d, transmitted, tr anscribed, stored in a retrieval system, or translated into any language or computer la nguage, in any form or by any means, electronic, mechanic al, magnetic, optical, chemical, manual, or other wise, without t ...

  • Intel SE8500 - page 3

    Content s User’s Guide for Server Configuration Wizard (SCW) Utility .......................... 1 1 Overview of Server Configurati on Wizard .................................................... 5 Technical Details .............................................................................................................. ....... 5 User’s Guid ...

  • Intel SE8500 - page 4

    User’s Guide for Server Confi guration Wizard (SCW) Util ity Configuring the Advanced Features...................................................................................... 25 Advanced Screen 1 – SNMP, KVM and Telnet Configuration ..................................... 25 Advanced Screen 2 – Web Configuration .......................... ...

  • Intel SE8500 - page 5

    1 Overview of Server Configuration Wizard The Server Configuration Wizard (SCW) is a comb ination of multiple utilities and data files that allow quick initial configuration of an Intel® Server. The SCW utility is available on the Intel® Server Deployment Toolkit CD, which can be used to boot the server. SCW is a DOS-based application, run from t ...

  • Intel SE8500 - page 6

    2 Quick Links (for Experienced Users of SCW) • Run DOS Utilities outside of SCW • Make Device Driver Diskettes by Operating System or by Device • From Disk Install for unattended Configuration, Cl oning, or to restore previous settings • ISM Question • Load FRU/SDRs • Add System Asset Tag • Set up Channels: LAN 1, Advanced LAN 3, or S ...

  • Intel SE8500 - page 7

    4 General Wizard Format and Synt ax Configuration options will be presented in a Wizard. Current settings will be displayed and can be accepted or changed. Square checkboxes allow mult iple choices in a section. Round radio buttons allow one choice per section (exclusive). The basic layout of each screen is: Figure 1. Screen Layout Syntax Feature D ...

  • Intel SE8500 - page 8

    User’s Guide for Server Confi guration Wizard (SCW) Util ity 5 Getting S t arted Booting the Server When booting the server from an Intel Server Deployment Toolkit CD, the startup files (autoexec.bat and config.sys) will create a RAMdrive . This RAMdrive will be used as a temporary storage area for the different components of the utility. Informa ...

  • Intel SE8500 - page 9

    Start Screen When the Wizard starts, the following Welcome screen is displayed. Figure 2. Start Screen Initial Options Choose Server Configuration Wizard to configure Channels, Us ers, and Advanced Settings. Choose Create Diskettes to place device drivers on re movable media. Choose Server Configuration Utilities to view which DOS Utilities can be ...

  • Intel SE8500 - page 10

    User’s Guide for Server Confi guration Wizard (SCW) Util ity 6 Configuration Screens Intel® Server Management (ISM) Question Both SCW and ISM have options to configure certain sections of the server’s firmware. By default, servers with the In tel® Management Module should: • Load FRUs and SDRs (can be done with SCW or FRU/SDR utility) • C ...

  • Intel SE8500 - page 11

    7 Selecting Options to Configure – Main Page The initial options screen shows subgroups of compone nts that SCW is capable of configuring. To have SCW perform the configuration, the component must be checked on this menu. Item s without check marks will NOT be configured by SCW and w ill not appear in subsequent screens. Whether or not the compon ...

  • Intel SE8500 - page 12

    User’s Guide for Server Confi guration Wizard (SCW) Util ity BIOS Date and Time: This screen also displays the BIOS, HSC, PIA, and Firmware versions. Figure 7. BIOS Date and Time Setting a System Asset Tag Figure 8. System Asset Tag • Acts as serial number or ID for the server. • The Continue button will be disabled until a System Asset Tag h ...

  • Intel SE8500 - page 13

    Channel Configuration (LANs and Serial/Modem) The number of channels available depends on the pl atform . Not all channels must be configured. Figure 9. Channels to Configure Feature Description Channel 1 d NIC1. On servers is not configu through the OS. On S The onboar NIC with dual ports onboard, the second red by SCW. This NIC can be used either ...

  • Intel SE8500 - page 14

    User’s Guide for Server Confi guration Wizard (SCW) Util ity LAN Channel Screens LAN Channels 1 and 3 use similar configuration scr eens, which will be illustrated here only once. Items that apply only for the GCM NIC (default is Channel 3) will not appear or will be gra y ed out when the standard NIC is chosen. Advanced F eatures configuration i ...

  • Intel SE8500 - page 15

    Resolve Gateway MAC Address Figure 11. Address Resolution If Alerts must cross subnets, the software will attempt to verify the gateway address to reach the Alert Destination. The Alert Destination is the console receiving the alert message from the configured server. It will use an entered MAC addr ess or attempt to find the IP address for the Ale ...

  • Intel SE8500 - page 16

    User’s Guide for Server Confi guration Wizard (SCW) Util ity LAN Channel, Screen 2 – Configure Out of Band (OOB) Access Figure 12. LAN Screen 2 – OOB and SOL Setup This screens sets up NIC1 or the GCM NIC for Out of Band access. Also sets up SOL (Serial over LAN) on NIC1. • Enable LAN Access: Enable access to the BMC when OOB.. • Enable S ...

  • Intel SE8500 - page 17

    LAN Channel, Screen 3 – Alerts Alerts can be sent over the network from the NIC or via e-mail (system dependent). The information needed is configured on Screen 3. Figure 13. LAN Screen 3 – Alerts • Enable LAN Alerting : Must be checked for alerts to be sent. • Alert Destination Console 1 IP Address • Alert Destination Console 2 IP Addres ...

  • Intel SE8500 - page 18

    User’s Guide for Server Confi guration Wizard (SCW) Util ity LAN Alert Filters If the user presses the LAN Alert Filters button on Sc reen 3 of LAN configuration, the available filters for LAN alerts (or email alerts with the Advanced module) are listed. Each item is an event that, if checked, will trigger an alert if that feature crosses the upp ...

  • Intel SE8500 - page 19

    Configuring the Serial/Modem Channel This option allows the setup of a modem on the Seri al Channel (default channel 4). Inform ati on on the modem’s strings is required and 3 screens are used to cover the options. • The first screen sets data specific to configuring the modem. • The second screen sets data specific to the access modes. • T ...

  • Intel SE8500 - page 20

    User’s Guide for Server Confi guration Wizard (SCW) Util ity Serial/Modem Screen 2 – Remote Server Management Figure 16. Serial 2 – Privilege and Mode • Enable Access: Allows OOB server management access via Modem on the serial channel • Privilege Level (see Access Level under Figure 13) : Note: Some platfor ms used Acce ss Mod e and Rest ...

  • Intel SE8500 - page 21

    Serial/Modem Screen 3 – Alerting Figure 17. Serial 3 – Alerts • Enable Paging : If enabled, sends alerts. • Alert Destination Phone Number: Phone number of the device to Receive the alerts. Device can be a pager, cell phone, modem of managing system . • Paging String: Characters sent after connect. This is c oncatenated with the Alert Des ...

  • Intel SE8500 - page 22

    User’s Guide for Server Confi guration Wizard (SCW) Util ity Serial Alert Filters Similar to LAN Alert Filters screen, this configur es the alerts to be used on the Serial Channel. Each item lists a filter that if checked, will send an alert if either threshold is crossed. Choose from none to all on an individual basis. The Select All and Clear A ...

  • Intel SE8500 - page 23

    Configuring Users – Selection Screen Up to 4 users can be configured for OOB Server Management access, depending on the platform. Click to place a checkmark in the box on each of the Users you wish to setup. Figure 19. User Selection • Choices are which of the 4 Users to configure. • Choosing multiple Users or Select All will run through the ...

  • Intel SE8500 - page 24

    User’s Guide for Server Confi guration Wizard (SCW) Util ity Settings Available per User Screens are similar for all users except if multiple users are chosen on the Advanced Module, User 1 (if enabled) must be the anonymous user. Figure 20. User Configuration • Enable User: If this box is checked, this user will be able to log into the BMC. ? ...

  • Intel SE8500 - page 25

    Configuring the Advanced Features The IMM – Advanced Edition provides m ultiple additional options for OOB management, provided regardless of the state of the OS using the GCM NIC. • SNMP – ability to manage via SNMP gets, sets, and traps. • KVM (ARSC) – Advanced Remote Server Console providing full access to the managed server by control ...

  • Intel SE8500 - page 26

    User’s Guide for Server Confi guration Wizard (SCW) Util ity Advanced Features Screen 2 – Web Configuration Figure 22. Advanced Screen 2 – Web • Enable HTTP: When enabled, HTTP sockets ar e opened and threads enabled. • HTTP Port #: Default port number is 80. Range is 1-6553 • HTTP Host Name: Domain name and HTTP host name of this serve ...

  • Intel SE8500 - page 27

    8 Set and Save the Configuration By default, the configuration is saved only to the local server and not to a file. If you wish to save the configuration for later restoration on this serve r or for unattende d configuration on an identical server model, place a checkmark in the Save Serv er Configuration to Disk box. A Windows style GUI is used to ...

  • Intel SE8500 - page 28

    User’s Guide for Server Confi guration Wizard (SCW) Util ity 10 Loading a Configuration from a Diskette If a previous SCW configuration has been saved to removable media, that file may be used on identical machines to run SCW in unattended m ode. The GUI displays the standard Windows interface to help locate the file. Settings from this file will ...

  • Intel SE8500 - page 29

    Appendix A. Acronyms and Glossary Term Definition Alerts LAN, Modem, or email notifications ARSC Advanced Remote Server Control (KVM redirect) BMC Baseboard Management Controller – found on the IMM BYO/PCT Platform Confidence Test CLI Command Line Interface FAT File Allocation Table, FAT 16 is a DOS 6.22 file format. DOS 7.1 and Windows after Win ...

  • Intel SE8500 - page 30

    User’s Guide for Server Confi guration Wizard (SCW) Util ity Appendix B. Removable Media Considerations 1. Required Format: The working environment of the Intel® Server Resource Toolkit CD at boot and hence the environment for SCW and the other utilities for the SE 73xx, SE75xx and SE8500 platform s is ROM-DOS, which uses the FAT16 file format. ...

Manufacturer Intel Category Computer Hardware

Documents that we receive from a manufacturer of a Intel SE8500 can be divided into several groups. They are, among others:
- Intel technical drawings
- SE8500 manuals
- Intel product data sheets
- information booklets
- or energy labels Intel SE8500
All of them are important, but the most important information from the point of view of use of the device are in the user manual Intel SE8500.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Intel SE8500, service manual, brief instructions and user manuals Intel SE8500. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Intel SE8500.

Similar manuals

A complete manual for the device Intel SE8500, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Intel SE8500 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Intel SE8500.

A complete Intel manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Intel SE8500 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Intel SE8500, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Intel SE8500, that we can find in the current document
3. Tips how to use the basic functions of the device Intel SE8500 - which should help us in our first steps of using Intel SE8500
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Intel SE8500
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Intel SE8500 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Intel SE8500?

Use the form below

If you did not solve your problem by using a manual Intel SE8500, ask a question using the form below. If a user had a similar problem with Intel SE8500 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)