  • American Dynamics AD2096A - page 1

    Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics AD2096A Alarm Interface Unit. The AD2096A Alarm Interface Unit, when used with American Dynamics Matrix Switching Systems, automatically calls specified cameras and preset scenes to specified monitors when contacts are a ...

  • American Dynamics AD2096A - page 2

    The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software/firmware is furnished to the purchaser under a license for use on a single system. Information furnished ...

  • American Dynamics AD2096A - page 3

    The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture. AMERICAN DYNAMICS CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMO ...

  • American Dynamics AD2096A - page 4

    ...

  • American Dynamics AD2096A - page 5

    CONTENTS Page DESCRIPTION .............................................................................. 1 FEA TURES .................................................................................... 1 INST ALLA TION ............................................................................ 1 Mounting ........................................... ...

  • American Dynamics AD2096A - page 6

    ...

  • American Dynamics AD2096A - page 7

    DESCRIPTION The AD2096A Alarm Interface Unit (AIU) is used with American Dynamics Matrix Switching Systems to provide automatic callup of a camera to a monitor when a specific alarm switch/contact input is activated. Each AD2096A AIU is set up to identify the matrix system video input and preset scenes with which it will be associated. The AD2096A ...

  • American Dynamics AD2096A - page 8

    SETUP Three 8-position DIP switches are used for AD2096A setup. The first two switches, S1 and S2, are located on the rear panel (see Figure 1, page 1). The top switch, S1, identifies the block of 64 alarm contacts (out of a possible 1024) which are connected to the AD2096A. The lower switch, S2, configures the AD2096A for either Normally Open (NO) ...

  • American Dynamics AD2096A - page 9

    CONNECTIONS Alarm Inputs Eleven 12-pin connectors are provided on the rear panel of the AD2096A for alarm inputs. A mating screw-terminal connector, below, is supplied for each rear panel connector. Each connector is labeled with an alarm number (1 - 64), an "A", and a ground symbol. The "A" stands for alarm contact and the grou ...

  • American Dynamics AD2096A - page 10

    OPERATION Power Sources Power is supplied via the appended 3-wire power cord. Power consumption is approximately eight watts. The AD2096A is configured for 120VAC, 50/60Hz, primary power source. Operating power voltages must be held within the 105V and 125V range. The AD2096-1 is configured for a 230VAC, 50/60 Hz primary power source. Operating pow ...

  • American Dynamics AD2096A - page 11

    T ypical System Connections ...

  • American Dynamics AD2096A - page 12

    ...

  • American Dynamics AD2096A - page 13

    ABCDEFGH ON OFF ON OFF SELECT ALARM POWER C O M INPUT OUTPUT ABCDEFGH N N C O C M 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 25 26 27 28 29 30 55 56 57 58 59 60 61 62 63 64 49 50 51 52 53 54 120V 60Hz MW AAAAAA AAAAAA AAAAAA AAAA AA AAAAAA AAAAAA AAAAAA AAAA AA AAAAAA AAAAAA AAAAAA MONIT ...

  • American Dynamics AD2096A - page 14

    ABCDEFGH ON OFF ON OFF SELECT ALARM POWER C O M INPUT OUTPUT ABCDEFGH N N C O C M 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 25 26 27 28 29 30 55 56 57 58 59 60 61 62 63 64 49 50 51 52 53 54 120V 60Hz AAAAAA A AAAAA AAAA AA AAAAAA AAAAAA A AAAAA AAAA AA AAAAAA AAAAAA AAAAAA AAAA AA RST L ...

  • American Dynamics AD2096A - page 15

    AD1996 AD2096A AUX START RELAY OUTPUT SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc.... NORMALLY OPEN/CLOSED POSITION FOR ALARM INPUTS 1-8, 9-16, 17-24 etc... TYPICAL SYSTEM CONNECTIONS AD2096A TO AD1996 PORTS PROG MON DATA LINE 12 120V 60Hz 12 34 56 7 8 91 0 1 2 3 45 6 7 8 TERMINAL BOX 2113-0019-01 BROWN (GRD) GREEN RED GREEN BROWN (GRD) RED TER ...

  • American Dynamics AD2096A - page 16

    C-5 TYPICAL SYSTEM CONNECTIONS AD2096A TO AD2150/2350 AD2150/2350 RS232 PORTS MONITORS 12 3 4 5 123 ALARMS RELAY KEYBOARDS 23 4 5 CAMERAS CODE 120V 60Hz BWS BWS BWS BWS 2468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 3 0 3 2 13579 1 1 1 3 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 3 1 AD2096A SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc.... NORMALLY OPE ...

  • American Dynamics AD2096A - page 17

    TYPICAL SYSTEM CONNECTIONS Cascading Multiple AD2096A Units AD2096A AD2096A 6003-0047-02 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 TERMINAL BOX 2113-0019-01 BROWN (GRD) GREEN RED GREEN BROWN (GRD) RED TERMINAL BOX 2113-0019-01 TYPICAL CONNECTIONS TO CASCADE MULTIPLE AD2096A UNITS: WHEN THE UNITS ARE LESS THAN 7' APART, USE MODULAR CABLE 6003-0047-02 WHE ...

  • American Dynamics AD2096A - page 18

    241 AD2010 Switching Bay PORTS 120V 60Hz DATA LINE 12 PROG MON 12 34 56 78 9 1 0 AD1996 1 AD2010DBVL Module 12 3 4 5 6 7 8 12 3 4 5 6 7 8 DATA LINE IN OUT SYNC 120 VAC 50/60 Hz 1 17 33 49 65 81 97 113 129 145 161 177 193 209 225 241 1 5 9 1 3 IN OUT ALARM POWER INPUT OUTPUT C O M 1 2 3 4 5 6 SELECT 29 28 30 27 26 25 49 50 51 52 53 54 7891 0 1 1 1 2 ...

  • American Dynamics AD2096A - page 19

    Index ...

  • American Dynamics AD2096A - page 20

    ...

  • American Dynamics AD2096A - page 21

    I-2 INDEX AD2096A Alarm Input Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Alarm Relay Output Connection . . . . . . . . . . . . . . . . . . . . . 3 Alarm Response Operation . . . . . . . . . . . . . . . . . . . . . . . . . 4 Baud Rate Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Block Setup . . . . ...

  • American Dynamics AD2096A - page 22

    ...

  • American Dynamics AD2096A - page 23

    DECL ARA TION OF CONFORMITY According to ISO/IEC G uide 22 and EN45014 Manufacturer’s N ame: Sensormatic Electr oni cs Corporation Manufacturer’s A ddress: 1 Blue Hill Plaza 2 nd Floor Pearl River, New York, 10965 USA Declares, that the product listed below: Name/Type: Alarm I nterface Unit Model Number: AD2096-1 complies with all applica ble d ...

  • American Dynamics AD2096A - page 24

    Sensormatic Video Systems Division One Blue Hill Plaza Pearl River, New York 10965 (845) 624-7600 Technical Support Center: 1-800-442-2225 FAX: 845-624-7685 8000-1819-01, Rev A December, 2000 Printed in USA SPECIFICATIONS Models AD2096A: 120 VAC, 50/60 Hz AD2096-1: 230 VAC, 50/60 Hz Electrical Input: AD2096A - 120 VAC, 50/60Hz, 8 W AD2096-1 - 230 V ...

Manufacturer American Dynamics Category Alarm Interface Unit

Documents that we receive from a manufacturer of a American Dynamics AD2096A can be divided into several groups. They are, among others:
- American Dynamics technical drawings
- AD2096A manuals
- American Dynamics product data sheets
- information booklets
- or energy labels American Dynamics AD2096A
All of them are important, but the most important information from the point of view of use of the device are in the user manual American Dynamics AD2096A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals American Dynamics AD2096A, service manual, brief instructions and user manuals American Dynamics AD2096A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product American Dynamics AD2096A.

A complete manual for the device American Dynamics AD2096A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use American Dynamics AD2096A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of American Dynamics AD2096A.

A complete American Dynamics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual American Dynamics AD2096A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the American Dynamics AD2096A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the American Dynamics AD2096A, that we can find in the current document
3. Tips how to use the basic functions of the device American Dynamics AD2096A - which should help us in our first steps of using American Dynamics AD2096A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with American Dynamics AD2096A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of American Dynamics AD2096A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning American Dynamics AD2096A?

Use the form below

If you did not solve your problem by using a manual American Dynamics AD2096A, ask a question using the form below. If a user had a similar problem with American Dynamics AD2096A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)