Manual Maxon Telecom 1800

17 pages 0.3 mb
Download

Go to site of 17

Summary
  • Maxon Telecom 1800 - page 1

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 6 E-m-7 / 0 8 Specifications of INDITHERM ® burners [1] sg (specific gravity) = relative density to air ( ...

  • Maxon Telecom 1800 - page 2

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 7 E-m-7 / 0 8 Materials of construction 1 Housing Cast iron 2 S tandard sleeve AISI 310 (1.4841) High temp ...

  • Maxon Telecom 1800 - page 3

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 8 E-m-7 / 0 8 Selection criteria Application det ails Because of the burner ’s versatility there are nu ...

  • Maxon Telecom 1800 - page 4

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 9 E-m-7 / 0 8 Burner d esignation Fuels INDITHERM ® b urners are designed to opera te on natural gas. Fo ...

  • Maxon Telecom 1800 - page 5

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 10 E-m-7 / 0 8 Control motor mounting plate The INDITH ERM ® burner can be eq uipped with an electri cal ...

  • Maxon Telecom 1800 - page 6

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 11 E-m-7 / 0 8 Flame supervision Flame supervision can be accompl ished by use of a UV-scanner for all IND ...

  • Maxon Telecom 1800 - page 7

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 12 E-m-7 / 0 8 Dimensions INDITHERM ® with standard disch arge sleeve - all sizes [1] gas inlet is thread ...

  • Maxon Telecom 1800 - page 8

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 13 E-m-7 / 0 8 INDITHERM ® with high temperature di scharge sleeve - all sizes [1] Gas inlet is threaded, ...

  • Maxon Telecom 1800 - page 9

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 14 E-m-7 / 0 8 Adjustable orifice for pilot burner - ADJ-ORF This orifice is standard included with the bu ...

  • Maxon Telecom 1800 - page 10

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 15 E-m-7 / 0 8 Spark ignitor - SI-1/2 The spark ignitor is standard included with the burner . It is adv i ...

  • Maxon Telecom 1800 - page 11

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 16 E-m-7 / 0 8 Gaskets - GSK- INDI These gaskets are used to seal the mountin g plate of the burner and th ...

  • Maxon Telecom 1800 - page 12

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 17 E-m-7 / 0 8 Installation and operat ion instructions for INDITHERM ® burners Application requirements ...

  • Maxon Telecom 1800 - page 13

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 18 E-m-7 / 0 8 INDITHERM ® with standard sleeve INDITHERM ® with block with sea l an d su pp ort housing ...

  • Maxon Telecom 1800 - page 14

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 19 E-m-7 / 0 8 Burner mounting flange Refer to below figure to desig n a correct burner mounting fla nge o ...

  • Maxon Telecom 1800 - page 15

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 20 E-m-7 / 0 8 Mounting flange for INDIT HERM ® burners with high temperatur e block sl eeve Dimensions i ...

  • Maxon Telecom 1800 - page 16

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 21 E-m-7 / 0 8 Start-up instructions for INDITHERM ® burners Instructions provided by the comp any or ind ...

  • Maxon Telecom 1800 - page 17

    Low temperature bur ners - INDITHERM ® www.maxoncorp .com combustion systems for indust r y MAXON reserves the right t o alter spec ifications and dat a without prior notice. © 2008 Copyright Maxon Corpor ation. All rights reserved. 1-2 . 3- 22 E-m-7 / 0 8 Maintenance and inspection Safety require ment s Regular inspection, testi ng and recalibra ...

Manufacturer Maxon Telecom Category Burner

Documents that we receive from a manufacturer of a Maxon Telecom 1800 can be divided into several groups. They are, among others:
- Maxon Telecom technical drawings
- 1800 manuals
- Maxon Telecom product data sheets
- information booklets
- or energy labels Maxon Telecom 1800
All of them are important, but the most important information from the point of view of use of the device are in the user manual Maxon Telecom 1800.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Maxon Telecom 1800, service manual, brief instructions and user manuals Maxon Telecom 1800. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Maxon Telecom 1800.

Similar manuals

A complete manual for the device Maxon Telecom 1800, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Maxon Telecom 1800 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Maxon Telecom 1800.

A complete Maxon Telecom manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Maxon Telecom 1800 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Maxon Telecom 1800, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Maxon Telecom 1800, that we can find in the current document
3. Tips how to use the basic functions of the device Maxon Telecom 1800 - which should help us in our first steps of using Maxon Telecom 1800
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Maxon Telecom 1800
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Maxon Telecom 1800 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Maxon Telecom 1800?

Use the form below

If you did not solve your problem by using a manual Maxon Telecom 1800, ask a question using the form below. If a user had a similar problem with Maxon Telecom 1800 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)