  • Miller Electric XMT 4-Rack - page 1

    Processes Description Multiprocess W elding Mounting Rack For Up T o Four XMT 300 W elding Power Sources With AUT O-LINK  And Requiring 230/460 V olt Input Power OM-815 October 1994 Eff. w/Serial Number KC310301 XMT 4-Rack R Visit our website at www.MillerWelds.com ...

  • Miller Electric XMT 4-Rack - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-800-4-A-Miller , or visit us at www .MillerW eld ...

  • Miller Electric XMT 4-Rack - page 3

    Miller offers a T echnical Manual which provides more detailed service and parts information for your unit. T o obtain a T echnical Manual, contact your local distributor . Y our distributor can also supply you with W elding Process Manuals such as SMAW , GT AW , GMAW , and GMAW -P . For practical information on welding, process applica- tions, and ...

  • Miller Electric XMT 4-Rack - page 4

    ...

  • Miller Electric XMT 4-Rack - page 5

    OM-815 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_5/97 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! Watch O ...

  • Miller Electric XMT 4-Rack - page 6

    OM-815 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 and Z87 ...

  • Miller Electric XMT 4-Rack - page 7

    OM-815 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit. F A ...

  • Miller Electric XMT 4-Rack - page 8

    OM-815 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However, after examining more than 500 studies spanning 17 years of ...

  • Miller Electric XMT 4-Rack - page 9

    OM-815 Page 5 SECTION 2 – SAFETY INFORMA TION mod1.1 2/93 Read all safety messages throughout this manual. Obey all safety messages to avoid injury . Learn the meaning of W ARNING and CAUTION. 1 Safety Alert Symbol 2 Signal Word W ARNING means possible death or serious injury can happen. CAUTION means possible minor injury or equipment damage can ...

  • Miller Electric XMT 4-Rack - page 10

    OM-815 Page 6 SECTION 4 – INST ALLA TION 4-1. Selecting A Location And Moving Rack W ARNING ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • Disconnect input power conductors from de- energized supply line BEFORE moving rack. FIRE OR EXPLOSION can result from placing unit on, over , or near com- bustible surfaces. • Do not l ...

  • Miller Electric XMT 4-Rack - page 11

    OM-815 Page 7 4-3. W elding Power Source Input Power Connections W ARNING ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • T urn Of f welding power source, and disconnect input power to rack before inspecting or installing. • Have only qualified persons install unit. • Installation must meet National Electrical Code and all ...

  • Miller Electric XMT 4-Rack - page 12

    OM-815 Page 8 4-4. Common Work Connections ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • T urn Off welding power sources by placing Power circuit breakers in the Of f position before making any weld output connections. • Do not connect welding output of dif ferent polarities to the same structure. • See ANSI Z49.1 and OSH ...

  • Miller Electric XMT 4-Rack - page 13

    OM-815 Page 9 4-5. Paralleling W elding Power Sources For SMA W ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • T urn Off welding power sources by placing Power circuit breakers in the Of f position before making any weld output connections. • Do not connect welding output of dif ferent polarities to the same structure. • S ...

  • Miller Electric XMT 4-Rack - page 14

    OM-815 Page 10 4-6. Connecting Input Power T o Rack W ARNING ELECTRIC SHOCK can kill. • Do not touch live electrical parts. • T urn Of f welding power sources before inspecting or installing rack. • Have only qualified persons install rack. • Installation must meet National Electrical Code and all other codes. swarn3.1* 2/93 Have only quali ...

  • Miller Electric XMT 4-Rack - page 15

    Ref. S-0092-G OM-815 Page 1 1 T able 4-2. Electrical Service Requirements* Input V oltage 230 460 Recommended Standard Fuse Or Circuit Breaker Rating In Amperes 1 250 125 Input Conductor Size In A WG/Kcmil 2 1/0 4 Max Input Conductor Length In Feet (Meters) 3 229 (70) 397 (121) Grounding Conductor Size In A WG/Kcmil 4 4 6 * These values are calcula ...

  • Miller Electric XMT 4-Rack - page 16

    OM-815 Page 12 5-2. Overload Protection 1 Power Circuit Breakers CB1-CB4 Each Power circuit breaker CB1 through CB4 protects the welding power source connected to it from overload. If a Power circuit breaker opens, th e matching welding power source would shut down. Manually reset the Power circuit breaker . ST-158 333 / Ref. ST -155 839 / Ref. ST- ...

  • Miller Electric XMT 4-Rack - page 17

    OM-815 Page 13 SECTION 6 – ELECTRICAL DIAGRAM SA-155 857 Figure 6-1. Circuit Diagram For Rack Control Box ...

  • Miller Electric XMT 4-Rack - page 18

    OM-815 Page 14 SECTION 7 – P ARTS LIST Description Part No. Item No. Figure 7-1. Main Assembly Quantity 1 155 878 COVER, top 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 032 473 GASKET , lift eye 1 . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric XMT 4-Rack - page 19

    OM-815 Page 15 ST-158 152 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 12 11 23 22 21 20 19 18 17 . Hardware is common and not available unless listed. Figure 7-2. Control Box ...

  • Miller Electric XMT 4-Rack - page 20

    OM-815 Page 16 Description Part No. Dia. Mkgs. Item No. Figure 7-2. Control Box (Fig 7-1 Item 14) Quantity 1 155 846 COVER, top control box 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 CB1-4 147 810 CIRCUIT BREAKER, mag 3P 60A 600V 4 . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric XMT 4-Rack - page 21

    Notes ...

  • Miller Electric XMT 4-Rack - page 22

    Notes ...

  • Miller Electric XMT 4-Rack - page 23

    Warranty Questions? Call 1-800-4-A-MILLER for your local Miller distributor. miller_warr 7/00 Y o ur distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The expertise ...

  • Miller Electric XMT 4-Rack - page 24

    PRINTED IN USA  2000 Miller Electric Mfg. Co. 6/00 Miller Elect ric Mfg. Co. An I l li noi s T ool Works Company 1635 W est Spencer Street Applet on, W I 5 4914 USA International He adquarters – US A USA Phone: 920-735-4505 Auto-A t t ended USA & C anada F AX : 9 20-735-4134 Int ernational F AX : 920-735-4125 European Headqua rters – Uni ...

Manufacturer Miller Electric Category Welder

Documents that we receive from a manufacturer of a Miller Electric XMT 4-Rack can be divided into several groups. They are, among others:
- Miller Electric technical drawings
- XMT 4-Rack manuals
- Miller Electric product data sheets
- information booklets
- or energy labels Miller Electric XMT 4-Rack
All of them are important, but the most important information from the point of view of use of the device are in the user manual Miller Electric XMT 4-Rack.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Miller Electric XMT 4-Rack, service manual, brief instructions and user manuals Miller Electric XMT 4-Rack. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Miller Electric XMT 4-Rack.

A complete manual for the device Miller Electric XMT 4-Rack, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Miller Electric XMT 4-Rack by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Miller Electric XMT 4-Rack.

A complete Miller Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Miller Electric XMT 4-Rack - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Miller Electric XMT 4-Rack, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Miller Electric XMT 4-Rack, that we can find in the current document
3. Tips how to use the basic functions of the device Miller Electric XMT 4-Rack - which should help us in our first steps of using Miller Electric XMT 4-Rack
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Miller Electric XMT 4-Rack
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Miller Electric XMT 4-Rack in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Miller Electric XMT 4-Rack?

Use the form below

If you did not solve your problem by using a manual Miller Electric XMT 4-Rack, ask a question using the form below. If a user had a similar problem with Miller Electric XMT 4-Rack it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)