Summary
  • Soleus Air SG-PAC-08E3 - page 1

    8,000 BTU Portable Air Conditioner Operating Instructions Model No. SG-P AC-08E3 ...

  • Soleus Air SG-PAC-08E3 - page 2

    Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner. This owner’s man- ual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few mome nts to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Porta ...

  • Soleus Air SG-PAC-08E3 - page 3

    3 SPEC IFICA TIONS • The cooling capacity is measured at an ambient tem perature of DB 95 °F, WB 83 °F. • Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in coolin g mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for refere ...

  • Soleus Air SG-PAC-08E3 - page 4

    LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side. The LCDI power cord and pl ...

  • Soleus Air SG-PAC-08E3 - page 5

    PRODUCT DIAGRAM Control Panel 5 Louvers Louver Guides Casters Power Cord Filters Upper Air Intake Lower Air Intake Remote Control Holder Air Exhaust V ent ...

  • Soleus Air SG-PAC-08E3 - page 6

    P ARTS & WINDOW KIT ASSEMBL Y PARTS EXHAUST HOSE & ADAPTERS ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the window kit and exhaust hose must be install ed. When the unit is operating in fan mode, the win dow kit and exhaust hose do not need to be installed . MOUNTING THE EXHAUST ...

  • Soleus Air SG-PAC-08E3 - page 7

    7 SINGLE HOSE WINDOW KIT INSTALLATION When installing the exhaust hose, try and keep it as flat as possible. The less angles and bends in the hose, the better the unit will perform. If be nding or an angle is necessary , use single 90 ° angles like the pictures above and below . Multip le bends will decrease performance and effi- ciency This insta ...

  • Soleus Air SG-PAC-08E3 - page 8

    CONTROL P ANEL, DISPLA Y , & OPERA TING INSTRUCTIONS CONTROL PANEL & LED DISPLAY CONTROL PANEL OPERATING INSTRUCTIONS 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 2) Mode Selection - Press the MODE Button repeatedly to cycle betwee n the different m od ...

  • Soleus Air SG-PAC-08E3 - page 9

    ...

  • Soleus Air SG-PAC-08E3 - page 10

    Sleep Mode - Press the SLEEP mode button to engage S LEEP mode. Sleep m ode automatically reduces the set temperature by 2 ° F after one hour and 4 ° F after two hours. This feat ure limits compressor usage and enhances energy savings while you are sleeping. Auto Mode - When AUTO mode is selected th e air cond ition er will automatically ch oose ...

  • Soleus Air SG-PAC-08E3 - page 11

    11 When the temperature or humidity is too high, the air conditioner may not be able to evaporate all of the water as quickly as needed. All moisture th at is un able to be evaporated is placed in a sm all bank up water tank in- side the unit. When this tank is com pletely full, an alarm will s ound, the compressor will shut off, and the bucket ful ...

  • Soleus Air SG-PAC-08E3 - page 12

    MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an el ectrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volum e may reduce. It is recommended to clean the filter onc e every two weeks or as needed. 1) Remove the filter from ...

  • Soleus Air SG-PAC-08E3 - page 13

    PROBLEM The Air Conditioner will not start POSSIBLE CAUSES The air conditioner is unplu gged or not connected well. The fuse is blown/circuit breaker is tripped. Power Failure The current interrupter device is tripped. SOLUTIONS • Make sure the air conditio ner plug is pushed completely into the out- let • Check the house fuse/ci rcuit breaker ...

  • Soleus Air SG-PAC-08E3 - page 14

    PROBLEM The LCD Display is showing “E5” POSSIBLE CAUSES Low Voltage Protection SOLUTIONS • Unplug for 10 minutes and then turn on the unit. If “E5” is still dis- played, contact customer service. TROUBLESHOOTING (CONT .) The LCD Display is showing “H8” The backup water tank is full • Drain the water tank • If the “H8” I still ...

  • Soleus Air SG-PAC-08E3 - page 15

    W ARRANTY One Year Limited Warranty Soleus International Inc. warrants the ac companying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications sp ecified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If th ...

  • Soleus Air SG-PAC-08E3 - page 16

    66129903751 ...

Manufacturer Soleus Air Category Air Conditioner

Documents that we receive from a manufacturer of a Soleus Air SG-PAC-08E3 can be divided into several groups. They are, among others:
- Soleus Air technical drawings
- SG-PAC-08E3 manuals
- Soleus Air product data sheets
- information booklets
- or energy labels Soleus Air SG-PAC-08E3
All of them are important, but the most important information from the point of view of use of the device are in the user manual Soleus Air SG-PAC-08E3.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Soleus Air SG-PAC-08E3, service manual, brief instructions and user manuals Soleus Air SG-PAC-08E3. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Soleus Air SG-PAC-08E3.

A complete manual for the device Soleus Air SG-PAC-08E3, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Soleus Air SG-PAC-08E3 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Soleus Air SG-PAC-08E3.

A complete Soleus Air manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Soleus Air SG-PAC-08E3 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Soleus Air SG-PAC-08E3, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Soleus Air SG-PAC-08E3, that we can find in the current document
3. Tips how to use the basic functions of the device Soleus Air SG-PAC-08E3 - which should help us in our first steps of using Soleus Air SG-PAC-08E3
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Soleus Air SG-PAC-08E3
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Soleus Air SG-PAC-08E3 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Soleus Air SG-PAC-08E3?

Use the form below

If you did not solve your problem by using a manual Soleus Air SG-PAC-08E3, ask a question using the form below. If a user had a similar problem with Soleus Air SG-PAC-08E3 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)