Premier Mounts PWM-F110 - page 1
INSTALLATION MANUAL PWM-F110 Premier Mounts 3130 E. Miraloma Avenue Anaheim, CA 92806 Phone: (800) 368-9700 Fax: (800) 832-4888 mounts@mounts.com www.mounts.com ...
-
Premier Mounts PWM-F110 - page 2
PBL-110 Projector Mount Page - 2 - Installation Manual ...
-
Premier Mounts PWM-F110 - page 3
PWM-F110 Installation Manual Page - 3 - Table of Contents Warning Statements ............................................................................................................ ............................... - 4 - Parts List ................................................................................................................... ...
-
Premier Mounts PWM-F110 - page 4
PWM-F110 Page - 4 - Installation Manual Warning Statements Safety Precautions This wall mount should be installed by qu al ified personnel having suffici ent skill and competence to install it. Qualified ins tallation specialists or your dealer should install th e mount and set up the plasma television in order to avoid pers onal injury or prope rt ...
-
Premier Mounts PWM-F110 - page 5
PWM-F110 Installation Manual Page - 5 - Mount Overview This PWM-F110 Plasma Wall Mount may be sold as part of a system or as an i ndepe ndent component. Wh ichever way it is purchased the installer must take care to us e only the hardware and components that co me incl uded in this package and tha t it only be used in conjunction with the appropria ...
-
Premier Mounts PWM-F110 - page 6
PWM-F110 Page - 6 - Installation Manual Parts List NOTE: This wall mount is shipped with all proper ins tallation hardware and components. Make sure that none of these parts are missing an d/or damaged be fore beginning installation. If there are parts missing and/or damaged, please stop the installation and contact Pre mier Mounts (800) 368-9700 E ...
-
Premier Mounts PWM-F110 - page 7
PWM-F110 Installation Manual Page - 7 - Mounting Bracket Installation NOTE : Proper installation procedure by qualified personnel as outlined in the install ation instructions must be adhered to. Failure to do so could result in serious personal injury an d possible damage to the flat panel. WARNING : INVERT THE FLAT PANEL AND PLACE IT ON A SOFT, F ...
-
Premier Mounts PWM-F110 - page 8
PWM-F110 Page - 8 - Installation Manual 3. If needed, install the nylon spacers to the mounting points on the flat panel (Figure 3). 4. Lay the left and right mounting brackets (stamped arrows facing out) - (Figure 4). Figure 3 Figure 4 5. Match the center of viewing guide with th e centerline you marked in step 1 (Figure 5). 6. The mounting bracke ...
-
Premier Mounts PWM-F110 - page 9
PWM-F110 Installation Manual Page - 9 - C L Figure 5 Figure 6 7. The Griplates™ have M4, M5, M6 and M8 hole p atterns to fit the hardware that your flat panel requires. EXAMPLE : If your flat panel uses M8 x 20 Phillip screws, use the M8 mountin g points (Figure 7). 8. Once the mounting brackets are aligned, secure the Griplate™ to the flat pan ...
-
Premier Mounts PWM-F110 - page 10
PWM-F110 Page - 10 - Installation Manual Wall Stud Location 1. Using a (commercially available) wood stud finder, locate four 16" or 24" stud centers behind the wall. Once found, make a pencil marking on the center of the wood studs (Figure 9). NOTE : The wall plates have (3) 16" and (1) 24" mounting slot positions (see Technica ...
-
Premier Mounts PWM-F110 - page 11
PWM-F110 Page - 11 - Installation Manual 3. To connect the two wall plates, lay them on a flat su rface, end to end. Make sure that the holes line up (Figure 11). 4. Insert two (2) M8 x 16mm Hex Head bolts throu gh the two holes and secure with two (2) M8 Hex nuts (Figure 11). 5. Place the bottom portion of the wall plate to the reference line and ...
-
Premier Mounts PWM-F110 - page 12
PWM-F110 Installation Manual Page - 12 - 7. Level and se cure the plate to the wall with the reference arrow facing up to the ceiling. 8. Secure the p late using the eight (8) 5/16" lag bolts and flat washers (supplied) – (Figure 13). CAUTION : Do not over tighten the lag bolts. NOTE : Use a minimum diameter of 5/16” x 3” long wood screw ...
-
Premier Mounts PWM-F110 - page 13
PWM-F110 Page - 13 - Installation Manual 9. Level and se cure the plate to the wall with the reference arrow facing up to the ceiling. 10. Use a minimum diameter of 5/16” x 2 ¼” large co ncrete wedge anchors (commercially available) – (Figure 14). CAUTION : Do not over tighten the wedge anchors bolts. NOTE : Use a minimum diameter of 5/16” ...
-
Premier Mounts PWM-F110 - page 14
PWM-F110 Installation Manual Page - 14 - Installing the Flat Panel Display WARNING : AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECOMMENDED FOR INSTALLATION OF THIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POSSIBLE DAMAGE TO THE FLAT PANEL. 1. Raise the flat panel with the LEFT and RIGHT mo unting brackets secured to the flat ...
-
Premier Mounts PWM-F110 - page 15
PWM-F110 Page - 15 - Installation Manual 2. Make any lateral shift adjustment and lock it by tightening the two (2) ¼”-20 Phillips screws f ound on the bottom of the mounting brackets. Use the wall bumper to adjust your flat panel. CAUTION : Do not over tighten the ¼”-20 screws to the rods (Figure 16). NOTE : To remove the flat panel from the ...
-
Premier Mounts PWM-F110 - page 16
PWM-F110 Installation Manual Page 19 Technical Specifications 16 . 0 0 0 ( 406 .4) 16 . 0 0 0 ( 406 .4) 1.9 43 (4 9 .3 ) 5.0 00 ( 127) 28 .00 0 ( 171 .2) C L 3.5 00 (88 .9) C L 5. 000 ( 127) 16 .0 00 ( 406 .4) 24 .29 0 ( 616 .97) 16 .00 0 ( 406 .4) 21 .7 90 (55 3.4) 1.2 45 ( 31. 75) A B C D E F G H B A F H 21 .79 0 ( 553 .4) Figure 17 ...
-
Premier Mounts PWM-F110 - page 17
PWM-F110 Page 20 Installation Manual Warranty Limited Lifetime Warranty All Premier Mounts products carry a limit ed lifetime warranty from ship date against defects in materials and workmanship. Premier Mounts is not liable for imprope r installation that result s in damage to mounts, adapters, display equipment or personal injury. Contact Premier ...
-
Premier Mounts PWM-F110 - page 18
PWM-F110 Installation Manual Page - 18 - Notes Premier Mounts 3130 E. Miraloma Avenue Anaheim, CA 92806 Phone: (800) 368-9700 Fax: (800) 832-4888 mounts@mounts.com www.mounts.com ...
Do you have a question concerning Premier Mounts PWM-F110?
Use the form below
If you did not solve your problem by using a manual Premier Mounts PWM-F110, ask a question using the form below. If a user had a similar problem with Premier Mounts PWM-F110 it is likely that he will want to share the way to solve it.