    Model 1985A Megapower CPU Standby Switch Installation Instructions The 1985A Standby Switch is for use with either two 1995 or two 1996 Switching Systems. The 1985A reads the high speed data line of each CPU and determines if both are functioning normally. The 1985A will detect most Switching System failures. In the event of a Switching System fail ...

  • American Dynamics AD1985A - page 2

    The software/fmware furnished with this equipment is confidential to and is copyrighted by AMERICAN DYNAMICS. It is not to be copied or disclosed in any manner without the express written consent of AMERICAN DYNAMICS. The software/fmware is furnished to the purchaser under a license for use on a single system, and remains the property of AMERICAN D ...

  • American Dynamics AD1985A - page 3

    - - -= - I -=AMERICAN - - --ADYNAMICS -I- - - The installation of this product should be made by qualified service personnel and should conform to all local codes. / [ DONOTOPEN J / 1 CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVERS (OR BACK) . NO USER - SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL I ...

  • American Dynamics AD1985A - page 4

    ...

  • American Dynamics AD1985A - page 5

    1985A MEGAPOWER CPU STANDBY SWITCH DESCRIPTION Mounting The 1985A Megapower Standby Switch allows two 1995 or 1996 CPUs to operate in tandem, where one CPU is the primary controlling CPU of the system and second is the backup CPU in stand - by mode. Operationally, all keyboard control input commands and the LAN output commands are routed through th ...

  • American Dynamics AD1985A - page 6

    1985A MEGAPOWER CPU STANDBY SWITCH RS - 232 Connector The RS - 232 connector used on all ports is an 8 - pin telephone type connector (RJ45). The terminal box supplied with the telephone cables has the same pinout signals as the telephone connectors, Please see Tables 1 for the pinout of these connectors. RS - 232 Connector Pinouts Table 1 - Teleph ...

  • American Dynamics AD1985A - page 7

    1985A MEGAPOWER CPU STANDBY SWITCH High Speed Control Code Line The two sets of three BNC connectors, located on the rear panel of the 1985A, are used to connect the high speed control code from the CPUs to the Video Switching System. (See Figure 2). Each 1995 and 1996 Series CPU contains two control code outputs. In the 1995 and the 19% the code l ...

  • American Dynamics AD1985A - page 8

    1985A MEGAPOWER CPU STANDBY SWITCH SETUP OPERATION All controls for the 1985A Standby Switch are located in the center of the unit’s front panel as shown in Figure 4 below. CPU SELECT SWITCH This 3-position switch selects whether the CPU that will run the video system is to be selected automatically (middle position) or manually (by selecting CPU ...

  • American Dynamics AD1985A - page 9

    APPENDIX ...

  • American Dynamics AD1985A - page 10

    APPENDIX A TYPICAL SYSTEM CONNECTIONS 1678CM TO 1985 0 I 13 I U U 1678CM THREE CONDUCTOR SHEWED BCLDON glro O R EQUVALH AD1 678TB M TP8059 Q 7.5 VOLTS AC ISAMP I NOTE ' THESE CONNECTIONS ARE TYPICAL OF ONE SYSTEM KEYBOARD. ...

  • American Dynamics AD1985A - page 11

    APPENDIX B TYPICAL SYSTEM CONNECTIONS 1676 TO 1985 1676 CPUl Ti cpua 2 3 6 78 9 10 ALARM TP8059 7.5 VOLTS AC 1.5 UI? NOTE :THESE CONNECTIONS ARE TYPICAL OF ONE SYSTEM KEYBOARD ...

  • American Dynamics AD1985A - page 12

    APPENDIX C TYPICAL SYSTE 1696 T il CONNECTIONS 1 1985 AUX START RELAY OCrrPvT -BROWN ALARM NOTE THESE CONNECTIONS ARE lWlCAL OF ONE ALARM INTERFACE UNIT. EACH RS232 PORT IS PROGRAMMABLE ...

  • American Dynamics AD1985A - page 13

    ...

  • American Dynamics AD1985A - page 14

    ... APPENDIX D (PAGE 2) TYPICAL SYSTEM CONNECTIONS 1995 TO 1985 w 1 CPU'S RECEIVE CPU'S , I 1995 ...

  • American Dynamics AD1985A - page 15

    APPENDIX E 1 TYPICAL SYSTEM CONNECTIONS 1996 TO 1985 lgg6 I /- Q 10 F DATAQ-&mpob n' 0 PGM MON 7' t ...

  • American Dynamics AD1985A - page 16

    SPECIFICATIONS: Humidity: Relative humidity behveen 8 percent and 90 percent (non - condensing). Supply Voltage: 1985A 120 V, 60 Hz (95 to 135 VACI) 1985A/X - 220 V, 50 Hz, (198 to 264 VAC) Power: 8 Watts nominal Mounting: Size: Weight: 19 Ibs. Finish: Dark Gray Free standing or rack mount with standard 19” rack (3 standard racks high) 5 1/4” H ...

Manufacturer American Dynamics Category Switch

Documents that we receive from a manufacturer of a American Dynamics AD1985A can be divided into several groups. They are, among others:
- American Dynamics technical drawings
- AD1985A manuals
- American Dynamics product data sheets
- information booklets
- or energy labels American Dynamics AD1985A
All of them are important, but the most important information from the point of view of use of the device are in the user manual American Dynamics AD1985A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals American Dynamics AD1985A, service manual, brief instructions and user manuals American Dynamics AD1985A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product American Dynamics AD1985A.

A complete manual for the device American Dynamics AD1985A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use American Dynamics AD1985A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of American Dynamics AD1985A.

A complete American Dynamics manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual American Dynamics AD1985A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the American Dynamics AD1985A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the American Dynamics AD1985A, that we can find in the current document
3. Tips how to use the basic functions of the device American Dynamics AD1985A - which should help us in our first steps of using American Dynamics AD1985A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with American Dynamics AD1985A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of American Dynamics AD1985A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning American Dynamics AD1985A?

Use the form below

If you did not solve your problem by using a manual American Dynamics AD1985A, ask a question using the form below. If a user had a similar problem with American Dynamics AD1985A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)