  • Crestron electronic 2-Series Control Processor - page 1

    ...

  • Crestron electronic 2-Series Control Processor - page 2

    This document was prepared and written by th e Technical Docum entation department at: Crestron Electronics, Inc. 15 Volvo D rive Rockleigh, NJ 076 47 1-888-CRESTRON ...

  • Crestron electronic 2-Series Control Processor - page 3

    Crestron CP2/CP2E 2-Series Integrated Control Processor Contents 2-Series Integrated Control Processor: CP2/CP2E 1 Introduc tion ................................................................................................................... ............ 1 Features and Functions ................................................................... ...

  • Crestron electronic 2-Series Control Processor - page 4

    ...

  • Crestron electronic 2-Series Control Processor - page 5

    Crestron CP2/CP2E 2-Series Integrated Control Processor 2-Series Integrated Control Processor: CP2/CP2E Introduction Features and Functions Crestron’s CP2 and CP2E 2-Series Integrated Con trol Processors, cost-competitive options in Crestron's 2-Series line of in te grated c ontrol system s, are designed for smaller home and comm ercial netw ...

  • Crestron electronic 2-Series Control Processor - page 6

    2-Series Integrated Control Processor Crestron CP2/CP2E bit Motorola ColdFire  processor. The 2-Series operating system is vastly upgraded from Crest ron’s X-gene ration pro ducts, yet compatible with existing Crestron software and programm ing. A key feat ure is the new Crestro n Compil er, which allows any existing Cres tron SIMPL™ W indow ...

  • Crestron electronic 2-Series Control Processor - page 7

    Crestron CP2/CP2E 2-Series Integrated Control Processor Physical Description The CP2/CP2E integrated control systems are housed in black enclos ures with labeling on t he front an d rear panels . The front panels of b oth units i nclude standar d LEDs and two reset buttons. All conn ections to the units are made through th eir rear panels. The fr o ...

  • Crestron electronic 2-Series Control Processor - page 8

    2-Series Integrated Control Processor Crestron CP2/CP2E Controls and Indicators The CP2/CP2E front panel indicators a nd controls a re described bel ow. PWR (Power) This LED illuminates when the unit is co nnected to and receives 24VDC power from an AC power pack or the C resnet NET connector. NET This LED illuminates when the central processing un ...

  • Crestron electronic 2-Series Control Processor - page 9

    Crestron CP2/CP2E 2-Series Integrated Control Processor NOTE: The orientation of this connector is “upside down” co mpared to other Crestron networ k devices (e.g., CNX-BI PAD8, CNX-RMCLV). Be sure the mating Cresnet cable connector is pr operly aligned before attempting to insert it, to avoid damage to the CP2/C P2E unit . This connect or (typ ...

  • Crestron electronic 2-Series Control Processor - page 10

    2-Series Integrated Control Processor Crestron CP2/CP2E COM Pinout to RS-485 Bus COM ( DB9) CO NNECT O R RS-485 BUS T ie Pins 1 & 9 - T ie Pins 4 & 6 + Pin 5 G INFRARED – SERIAL OU TPUT A B C D E F G H S G S G S G S G INFRA RED - SERIAL OUTPUT S G S G S G S G These connectors provi de eight serial outp uts for IR or serial int erface. Eac ...

  • Crestron electronic 2-Series Control Processor - page 11

    Crestron CP2/CP2E 2-Series Integrated Control Processor 24VDC, 2.0A (Power Supply) 24VDC 2.0A This male connector can be used to supply 24 VDC power to the CP2/CP2E from an AC power pac k purchased se parately. (Re fer to O ptional Powe r Supply on page 1 3). When power is supplied to th e units through this connector, 24VDC, 24W is also available ...

  • Crestron electronic 2-Series Control Processor - page 12

    2-Series Integrated Control Processor Crestron CP2/CP2E series control engine. Non-vo latile memory c ontains information that is retained after loss of electrical power. Volatile memory is lost after a power failure. Refer to the lists below for a breakdown of memory usage for program-related information stored in the unit. Flash The 4MB flas h me ...

  • Crestron electronic 2-Series Control Processor - page 13

    Crestron CP2/CP2E 2-Series Integrated Control Processor DRAM DRAM is use d by the ope rating system for dynam ic storage of variables, si gnals and other const ructs use d at runti me. The actua l amount of DR AM used at a ny given time depends on the particular program that is running , i.e., usage is variable, or dynamic, du ring norm al operat i ...

  • Crestron electronic 2-Series Control Processor - page 14

    2-Series Integrated Control Processor Crestron CP2/CP2E Ear Attachment for Rack Mounting (CP2E shown in illustration) 1. Using a Phillips screwdriver, remove and retain the three side screws closest to the fr ont panel. 2. Position a rack ear so that its mounting holes align with the vacated holes, and secure the ear to t he unit with the three sc ...

  • Crestron electronic 2-Series Control Processor - page 15

    Crestron CP2/CP2E 2-Series Integrated Control Processor 5. Secure the wires connected to the te rm inal block with a ti e wrap around the bussing stri p to provi de strain reli ef. Network Wiring NOTE: When making wire connections, refer to the latest revision of the Cresnet Network Inte rconnect Dra wing (Doc. 5411 ). The document can be obtai ned ...

  • Crestron electronic 2-Series Control Processor - page 16

    2-Series Integrated Control Processor Crestron CP2/CP2E Wire Gauge Values RESISTANCE (R) WIRE GAUGE 4 16 6 18 10 20 15 22 13 Doubled CAT 5 8.7 Tripled CAT5 NOTE: When dais y-chaining Cresnet unit s, stri p the ends of the wires carefully to avoid nicking the condu ctors. Twist together the ends of the wires that share a pi n on the network conn ect ...

  • Crestron electronic 2-Series Control Processor - page 17

    Crestron CP2/CP2E 2-Series Integrated Control Processor Optional Power Supply The units ca n be powe red through t he NET netw ork conne ctor, or by an optional AC power p ack (pur chased separa tely). If an ex ternal power supply is to be used , Crestron reco mmends it s CNPWS-75 E xternal Po wer Supply or PW-24 20RU Universal Power Pack, or e qui ...

  • Crestron electronic 2-Series Control Processor - page 18

    2-Series Integrated Control Processor Crestron CP2/CP2E Slot 1: C2Net-Device The C2Net-De vice slot ena bles the CP2 an d CP2E to c ontrol up t o 252 Cr esnet devices. Each Cresnet de vice is assigned a unique identifier called a Net ID, which is a hexadecim al value rangi ng from 03 to FE. To view the list of supported devices, ex pand the control ...

  • Crestron electronic 2-Series Control Processor - page 19

    Crestron CP2/CP2E 2-Series Integrated Control Processor Slot 3: C2I-IO8 The CP2 and C P2E pro vide eight I/O ports c alled Ve rsiports, eac h of whi ch can function as a digital i nput, a di gital out put, or an a nalog in put. Each Versi port has a correspondin g pullup resistor. In Program Manager, d rag the C2I-I O8 sym bol from Progr am View to ...

  • Crestron electronic 2-Series Control Processor - page 20

    2-Series Integrated Control Processor Crestron CP2/CP2E Driving the correspondi ng <pu-disabl e> signal hi gh can modi fy this beha vior. This i s not recommended, though , since it will cause the output pin to float when < o > goes low. Example 1 (rec ommended): The < pu-disable1 > signal is driven low or left undefined. When < ...

  • Crestron electronic 2-Series Control Processor - page 21

    Crestron CP2/CP2E 2-Series Integrated Control Processor A voltage source is pl aced on Ve rsiport 1 a nd < MinChange1 > is set t o 10 via an Analog Initialize symbol. The value of < i1 > will not be propag ated until it changes by at least 10. If the current value is 500, then a new value will not be reported until it chang es to 510 or ...

  • Crestron electronic 2-Series Control Processor - page 22

    2-Series Integrated Control Processor Crestron CP2/CP2E 3. When all t he IP IDs and ass ociated IP ad dresses have been adde d to the IP Table, click Send IP Table to Contr ol System . As with all 2-Series control systems, the CP2E has the capability to fun ction as a peripheral d evice, or “sla ve”, in a m aster/slave arra ngement with another ...

  • Crestron electronic 2-Series Control Processor - page 23

    Crestron CP2/CP2E 2-Series Integrated Control Processor If the program contains S IMPL+ or User modules , the conversion might generate error messages. This is because m odules and programs often c ontain symbols with “ambiguous” s ignals. F or exam pl e, the inputs of the Serial to Analog sym bol can be defined as eith er analog or serial. Alt ...

  • Crestron electronic 2-Series Control Processor - page 24

    2-Series Integrated Control Processor Crestron CP2/CP2E Module Header Information After you convert each module in a prog ram, you can convert the program as described pre viously: dra g the CP2 or CP2E ont o the exis ting cont rol syst em in System Views and click Yes to confirm the re placement. For further i nformat ion about com pile-tim e erro ...

  • Crestron electronic 2-Series Control Processor - page 25

    Crestron CP2/CP2E 2-Series Integrated Control Processor • Hardware ha ndshaking (R TS/CTS) e nabled. • Software ha ndshaki ng (XON/ XOFF) not e nabled. “Port Settings” dialog box: Default PC se ttings for RS-232 co mmunication with the CP2/CP2E. To verify com muni cation, click Diagnostics | Establish Communications (Find Rack) . T his shou ...

  • Crestron electronic 2-Series Control Processor - page 26

    2-Series Integrated Control Processor Crestron CP2/CP2E use a CAT5 cr ossover cabl e to connect th e two LAN ports directly, without using a hub. Once the cable connections are made, ope n the Crest ron Viewpo rt and clic k Setup | Communication Settings on the m enu to di splay the “Po rt Settings” di alog bo x. Then click TCP/I P as the conn ...

  • Crestron electronic 2-Series Control Processor - page 27

    Crestron CP2/CP2E 2-Series Integrated Control Processor some ma y be internal (e. g., for a m odem). Cons ult the m anufacture r’s documentation for fur ther information about th e COM ports on your PC. 3. Check the ERR LED indicat or on the f ront panel of the CP 2/CP2E. If this LED is illuminated, unplug the unit and reapply power after a few s ...

  • Crestron electronic 2-Series Control Processor - page 28

    2-Series Integrated Control Processor Crestron CP2/CP2E Compiling and Uploading a Program to the Control System After you have completed your SI MPL Windows program you must compile and upload the program to the control system. To compile the program, simply click the Convert/Compile button on the SIMPL Windo ws toolbar, o r select Project | Conver ...

  • Crestron electronic 2-Series Control Processor - page 29

    Crestron CP2/CP2E 2-Series Integrated Control Processor Another way to verify t hat the program has been tra nsferred successfully is to select Report Program Information on the View port Functions menu. Prog ram information is also disp layed in the View port console whenever power is removed and re-applied to the CP2/CP2E. Uploading Web pages to ...

  • Crestron electronic 2-Series Control Processor - page 30

    2-Series Integrated Control Processor Crestron CP2/CP2E Uploading Touchpanel Pr ojects via the CP2/CP2E You can use a connection t o the CP2 or CP2E to upload Visi onTools Pro- e projects to any Cresnet touchpa nel. Com piled projects f or TPS pane ls are contai ned in V TZ files; project s for all othe r touchpa nels are cont ained in HEX files. B ...

  • Crestron electronic 2-Series Control Processor - page 31

    Crestron CP2/CP2E 2-Series Integrated Control Processor 3. After the transfer is complete, the CP2/CP2E will automatically reboot. To confirm the tr ansfer , click Diagnostics | Check Ops Version . The Viewport c onsole sho uld disp lay the new .c uz versi on num ber. Advanced Console Commands The SIMPL Wi ndows onli ne help fil e provides a full l ...

  • Crestron electronic 2-Series Control Processor - page 32

    2-Series Integrated Control Processor Crestron CP2/CP2E Troubleshooting The table belo w and on t he next page provides cor rective action fo r possible trouble situations. If further assistance is requi red, please contact a Crestron cust omer service representative. CP2/CP2E Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Unexpected r ...

  • Crestron electronic 2-Series Control Processor - page 33

    Crestron CP2/CP2E 2-Series Integrated Control Processor Battery Replacement A Lithium battery is used to power the system clock within the CP2/CP2E. Under normal conditions, it will last for approximately 10 years. In the event that the clock fails, only an authorized technician sh ould replace it. Refer to caution statem ent below. CAUTION: Dange ...

  • Crestron electronic 2-Series Control Processor - page 34

    2-Series Integrated Control Processor Crestron CP2/CP2E Passthrough Mode Dialog Box The PC will now be communicating directly with th e device. To exit Passthr ough mode, simply cl ick Functions | Exit Passthr ough Mode . A system reboot will also exit Passthrough mode. 30 • 2-Series Integrated Cont rol Processor: CP2/CP2E Operations Guide - DOC. ...

  • Crestron electronic 2-Series Control Processor - page 35

    Crestron CP2/CP2E 2-Series Integrated Control Processor Further Inquiries If after reviewing this Operations Guide, you cannot locate specific information or have questions , please take a dvantage of Crestron's award winning c ustomer servi ce team by calling: • In the US and Canada, call C restr on's corpo rate headquarte rs at 1-888- ...

  • Crestron electronic 2-Series Control Processor - page 36

    2-Series Integrated Control Processor Crestron CP2/CP2E Software License Agreement This License Agreement (“Agree ment”) is a legal contract betw een you (either an individual or a single business entit y) and Crestron Electronics, Inc. (“Crestron”) for so ftware referenced in this guide, which in cludes co mputer softwa re and, as applica ...

  • Crestron electronic 2-Series Control Processor - page 37

    Crestron CP2/CP2E 2-Series Integrated Control Processor If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully document and certify that use of any and all Software at the time of the request is in conformity with Your valid licenses from Cres tron of its auth ...

  • Crestron electronic 2-Series Control Processor - page 38

    2-Series Integrated Control Processor Crestron CP2/CP2E Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchan dise may be retur ned for cr edit, exchan ge, or service without prior authorization from CR ESTRON. To obt ain warrant y service f or CRESTR ON products, cont act the fact ory and req uest an RMA (R eturn Me rchan ...

  • Crestron electronic 2-Series Control Processor - page 39

    Crestron CP2/CP2E 2-Series Integrated Control Processor This page intentionally left blank . Operations Guide - DOC. 5980 2-Series Integrated Control Processo r: CP2/CP2E • 35 ...

  • Crestron electronic 2-Series Control Processor - page 40

    Crestron Electronics, Inc. Operations Guide – DOC. 5980 15 Volvo Drive Rockleigh, NJ 07647 02.02 Tel: 888.CRESTRON Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice. ...

Manufacturer Crestron electronic Category Computer Hardware

Documents that we receive from a manufacturer of a Crestron electronic 2-Series Control Processor can be divided into several groups. They are, among others:
- Crestron electronic technical drawings
- 2-Series Control Processor manuals
- Crestron electronic product data sheets
- information booklets
- or energy labels Crestron electronic 2-Series Control Processor
All of them are important, but the most important information from the point of view of use of the device are in the user manual Crestron electronic 2-Series Control Processor.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Crestron electronic 2-Series Control Processor, service manual, brief instructions and user manuals Crestron electronic 2-Series Control Processor. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Crestron electronic 2-Series Control Processor.

A complete manual for the device Crestron electronic 2-Series Control Processor, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Crestron electronic 2-Series Control Processor by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Crestron electronic 2-Series Control Processor.

A complete Crestron electronic manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Crestron electronic 2-Series Control Processor - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Crestron electronic 2-Series Control Processor, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Crestron electronic 2-Series Control Processor, that we can find in the current document
3. Tips how to use the basic functions of the device Crestron electronic 2-Series Control Processor - which should help us in our first steps of using Crestron electronic 2-Series Control Processor
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Crestron electronic 2-Series Control Processor
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Crestron electronic 2-Series Control Processor in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Crestron electronic 2-Series Control Processor?

Use the form below

If you did not solve your problem by using a manual Crestron electronic 2-Series Control Processor, ask a question using the form below. If a user had a similar problem with Crestron electronic 2-Series Control Processor it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)