Manual Liebert UPS Systems PSI XR

32 pages 1.59 mb
Download

Go to site of 32

Summary
  • Liebert UPS Systems PSI XR - page 1

    AC P ow er For Business-Criti cal C on tinuity™ Li eber t ® PSI XR ™ Us er Man ual–1000/1500/ 1920/3000V A, 60Hz, 120V AC ...

  • Liebert UPS Systems PSI XR - page 2

    ...

  • Liebert UPS Systems PSI XR - page 3

    i T ABLE OF CONTENTS 1.0 I NTRODUCTI ON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.0 W HAT ’ S I NCLU DED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3.0 I NST ALLATION . . . . . . . . . . . . . . . . . ...

  • Liebert UPS Systems PSI XR - page 4

    ii 7.0 B ATTERY M AINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 7.1 Battery Charging, Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 7.2 Internal Battery Replacement Procedure . . . . . . . . . . . . . . . . . . . ...

  • Liebert UPS Systems PSI XR - page 5

    1 I MPORT ANT S AFETY I NSTRUCTIONS SA VE THESE INSTRUCTIONS This manual co ntains important instructio ns that should be followed du ring installation and ma inte- nance of the UPS. • Intended for installat ion in a temperature-contro lled, indoor area free of conductive contami- nants. • Maximum ambient temperature 104°F (40°C). Read this m ...

  • Liebert UPS Systems PSI XR - page 6

    2 ELECTROMAGNETIC COMP ATIBILITY —The Liebert PSI XR complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: • This device may not cause harmful interference, and • This device must accept any in terference received, including in terference that may cause unde- sired operation. This equipment uses, genera ...

  • Liebert UPS Systems PSI XR - page 7

    3 G LOSSARY OF S YMBOLS Risk of ele ctrical shock Indicates caution followed by important instructions Indicates the unit contains a valve-regulated, lead-ac id battery Recycle DC voltage Equipment grounding conductor Bonded to ground AC voltage ON/Alarm Silence/Manual Self-Diagnostic Test OFF Status Change Button ! ...

  • Liebert UPS Systems PSI XR - page 8

    Introd uction 4 1.0 I NTRODUCTION The Liebert PSI ™ XR is a 2U, line-in teractive UPS that may b e installed in a rack or used as a tower UPS. Status indicators on the front of the Liebert PSI XR display load level, battery level, buck/boost, site- wiring fault and battery st atus. Controls include a combination ON/ Alarm Silenc e/Manual Self-Dia ...

  • Liebert UPS Systems PSI XR - page 9

    Introd uction 5 Figure 3 1920V A—rear view Figure 4 3000V A—rear view DC 48V OUTPUT EPO INPUT VOLT AGE=1 10V VOLT AGE=120V VOLT AGE=127V 2 1 FUNCTION RJ-45 Data Line Connec tors USB Port RS232 (DB-9) Port Power Cord; 5-20P (not shown for cla rity) EPO External Battery Cabinet Conn ector V oltage Configuration DIP Switch 15A Output Circuit Break ...

  • Liebert UPS Systems PSI XR - page 10

    What’ s Included 6 2.0 W HAT ’ S I NCLUDED The Liebert PSI XR is shipped with the following items: • Multi-Language User Manual on CD • Liebert Mu ltiLink Shutdown So ftware and User Manual on CD • DB-9 Serial Cable • USB Cable • Tower Stand • Rack-Mou nt Handles • Battery-UPS Tab • Mounting Hardware • Fixed Moun ting Rails ? ...

  • Liebert UPS Systems PSI XR - page 11

    Installation 7 3.0 I NST ALLATION 3.1 Prep aration The Liebert PSI XR may be installe d in either a tower or rack conf iguration. Determine the method that suits the applica tion and proceed. Decide where to install the Liebert PSI X R. The UPS must be installed indoor s in a controlled envi- ronment. Place it in an area with unrestricted ai rflow ...

  • Liebert UPS Systems PSI XR - page 12

    Installation 8 3.2 T ower UPS Installation See Figure 7 when using the Liebert PSI XR in a tower configuration. Figure 7 T ower configuration—att ach T ower St and Step 1 Step 2 ...

  • Liebert UPS Systems PSI XR - page 13

    Installation 9 3.3 Rack-Mount U PS Conversion and Inst allation See Fi gure 8 when installing the Liebert PSI XR in a rack. Ex ternal battery cabinets are inst alled in same manner. Figure 8 Convert the Liebert PSI XR f or rack inst allation NOTICE When rack-mounted, the UPS must be supported by a shelf, slide rails, brackets or fixed rails on each ...

  • Liebert UPS Systems PSI XR - page 14

    Installation 10 3.4 Orient Display for Inst allation The Liebert PSI XR features a rotating display that may be oriented fo r either tower or rack ins talla- tions. To set the display for your installation, pull out on the di splay and rotate it until it i s oriented cor- rectly, then press it i nto the UPS until it is seated. Figure 9 Adjusting th ...

  • Liebert UPS Systems PSI XR - page 15

    Installation 11 3.6 Connect Network Surge protection Connect a 10 base-T/100 network cable to the RJ-45 network surge protection IN jack on the rear of the UPS. Connect from the OUT jack w ith network cabling to network equipment (see Figure 11 ). Figure 1 1 Connect network surge prot ection 3.7 Connect Computer Interface Port Determine what type o ...

  • Liebert UPS Systems PSI XR - page 16

    Installation 12 3.8 EPO Switch The Liebert PSI XR is equipped with an Emergency Powe r Off (EPO) switch. The user must supply a means of interfacing with the EPO circuit to allo w disconnecting the UPS input feeder breaker to interrupt all sources of po wer to the UPS and connected equipment to comply with national and local wiring codes and regula ...

  • Liebert UPS Systems PSI XR - page 17

    Installation 13 Figure 15 Connect battery cabinet s to UPS See Table 8 for approx imate battery run times. DC 24V OUTPUT INPUT EPO VOLTAGE=1 10V VOLTAGE=120V VOLTAGE=127V 2 1 FUNCTION ...

  • Liebert UPS Systems PSI XR - page 18

    Controls and Indica tors 14 4.0 C ONTROLS AND I NDICATORS Buttons on the front panel displa y control the Lieb ert PSI XR. Eight L EDs indica te the UPS’s statu s. Refer to Figure 16 and Table 2 . Figure 16 Display and st atus indicators T able 2 Display and st atus indicators f unction, legend Item Name Status Indicators Description 1 LED 1 AVR ...

  • Liebert UPS Systems PSI XR - page 19

    Controls and Indica tors 15 4.1 Control Buttons 4.1.1 On/Alarm Silence/Manual Self-Diagnostic T est This button controls output power to co nnected load (s). It has three functions: •O n •A l a r m S i l e n c e • Manual Self-D iagnostic Test ON —Start the UPS by pressing this button for more than 3 seconds, then releasing the button (an al ...

  • Liebert UPS Systems PSI XR - page 20

    Controls and Indica tors 16 4.2.3 Battery Level Indicator The five LEDs illuminate with a steady glow to indicate battery capacity. Battery capacity is shown for five second s after the Status Change Button is pressed. The LEDs show the battery capacity as a range, ± 5% The LEDs’ battery level meanings and colors are: 4.2.4 UPS St atus Indicator ...

  • Liebert UPS Systems PSI XR - page 21

    Operational Modes 17 5.0 O PERATIONAL M ODES 5.1 Normal Mode When the UPS is in Normal Mode, the No rmal Mode Indicato r illumina tes green. 5.2 Buck/Boost Mode The Automatic Voltage Regulator (AVR ) circuitry compensates for fluctu ations in utility power, su ch as voltage surges and sags. When the Liebert PSI XR detects an abnormality, it raises ...

  • Liebert UPS Systems PSI XR - page 22

    Communication 18 6.0 C OMMUNICATION 6.1 DB-9 Connector The UPS has a DB-9 (9 pin female) connector on the rear to allow UPS statu s communications with a computer running Liebert MultiLi nk shutdown soft ware. The connection prov ides serial communica- tion, On Battery and Low Battery signals. Liebert MultiL ink software and a 6 ft. (1.8m) DB-9 ser ...

  • Liebert UPS Systems PSI XR - page 23

    Communication 19 6.3 RJ-45 Dat a Line Protection Connectors Data line (in and out) connectors on the rear o f the UPS provide transient voltage surge suppression (TVSS) for network devices. 6.4 UPS Communications The Liebert PSI XR is equipped with a Liebert IntelliSlot ® port to provide advanced communication and monitoring options. Liebert Multi ...

  • Liebert UPS Systems PSI XR - page 24

    Battery Maintenance 20 7.0 B ATTERY M AINTENANCE 7.1 Battery Charging, S torage The batteries are valve-regulated, nonspillabl e, lead acid and must be kept charged to retain their design life . The Liebert PSI XR con tinuously charg es the batteries wh en connected to th e utility sup- ply, even while the UPS is switched Off. If the Liebert PSI XR ...

  • Liebert UPS Systems PSI XR - page 25

    Specifications 21 8.0 S PECIFICATIONS T able 6 Liebert PSI XR specifications Model Number PS1000RT3-120XR PS1000RT3120XRW PS1500RT3-120XR PS1500RT3120XRW PS2200RT3-120XR PS2200RT3120XRW PS3000RT3-120XR PS3000RT3120XRW Power Rating, VA/W 1000VA/900W 1500VA/13 50W 1920VA/1920W * 3000VA/270 0W Dimensions, W x D x H, in (mm) Unit 17.3 x 19.3 x 3.5 (440 ...

  • Liebert UPS Systems PSI XR - page 26

    Specifications 22 T able 7 Battery cabinet specifica tions Model Number PSRT3-24VBXR PSRT3-48VBXR Used w/UPS Model PS1000RT3-120XR PS1000RT3120XRW PS1500RT3-120XR PS1500RT3120XRW PS2200RT3-120XR PS2200RT3120XRW PS3000RT3-120XR PS3000RT3120XRW Dimensions, W x D x H, in (mm) Unit 17.3 x 19.3 x 3.5 (440 x 490.5 x 88) Shipping 22 x 26.6 x 9 (560 x 675 ...

  • Liebert UPS Systems PSI XR - page 27

    Specifications 23 T able 8 Liebert PSI XR battery run times Number of Batteries Load % 10 00VA 1500VA 1920VA 3000VA Internal Battery 10 82 81 76 75 25 43 32 32 32 50 15 13 14 13 7 5 9888 1 0 0 6555 Internal Battery + 1 External Battery Cabinets 10 272 222 161 142 25 139 109 80 70 50 73 55 45 31 75 51 31 25 17 100 31 18 15 12 Internal Battery + 2 Ex ...

  • Liebert UPS Systems PSI XR - page 28

    Trou bleshooting 24 9.0 T ROUBLESHOOTING The informatio n below indicates va rious symptoms a user may encoun ter if the Liebert PSI XR expe- riences a problem. See Table 9 for suggested solutions. 1. An alarm sounds, alerting that the UPS requires attention. The al arm can be silenced except for low battery, overload warning an d fault. 2. One or ...

  • Liebert UPS Systems PSI XR - page 29

    Trou bleshooting 25 Notes ...

  • Liebert UPS Systems PSI XR - page 30

    Trou bleshooting 26 ...

  • Liebert UPS Systems PSI XR - page 31

    ...

  • Liebert UPS Systems PSI XR - page 32

    EmersonNetworkPower.com Ensuring The Hi gh Av ailabi lit y Of Mission-Critic al Data And Ap plic ations. Emerson Net work P ower , the global leader in enabling business-critical continuity , ensures network re siliency and adaptabilit y through a family of technologies—inc luding Liebert power and cooling technologies—that prot ect and suppor ...

Manufacturer Liebert Category Power Supply

Documents that we receive from a manufacturer of a Liebert UPS Systems PSI XR can be divided into several groups. They are, among others:
- Liebert technical drawings
- UPS Systems PSI XR manuals
- Liebert product data sheets
- information booklets
- or energy labels Liebert UPS Systems PSI XR
All of them are important, but the most important information from the point of view of use of the device are in the user manual Liebert UPS Systems PSI XR.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Liebert UPS Systems PSI XR, service manual, brief instructions and user manuals Liebert UPS Systems PSI XR. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Liebert UPS Systems PSI XR.

Similar manuals

A complete manual for the device Liebert UPS Systems PSI XR, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Liebert UPS Systems PSI XR by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Liebert UPS Systems PSI XR.

A complete Liebert manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Liebert UPS Systems PSI XR - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Liebert UPS Systems PSI XR, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Liebert UPS Systems PSI XR, that we can find in the current document
3. Tips how to use the basic functions of the device Liebert UPS Systems PSI XR - which should help us in our first steps of using Liebert UPS Systems PSI XR
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Liebert UPS Systems PSI XR
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Liebert UPS Systems PSI XR in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Liebert UPS Systems PSI XR?

Use the form below

If you did not solve your problem by using a manual Liebert UPS Systems PSI XR, ask a question using the form below. If a user had a similar problem with Liebert UPS Systems PSI XR it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)