Manual Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2

52 pages 3.76 mb
Download

Go to site of 52

Summary
  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 1

    Owner’ s Man ual Liquid-cooled, Prepac kaged Standby Generator s Models: 004912-0, 004912-1 (15 kW LP/15 kW Natural Gas) 120/240V Single-phase w/ 100 Amp T ransfer Switch 004913-0, 004913-1, 004913-2 (25 kW LP/25 kW Natural Gas) 120/240V Single-phase w/ 200 Amp T ransfer Switch ONL Y QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD A TTEMPT INST ALLA ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 2

    Generac ® Pow er Systems, Inc. I NTRODUCTION Thank you for purchasing this model of the standby generator product line by Generac P ower Systems. Every effort was expended to make sure that the information and instructions in this manual are both accurate and current at the time the manual was written. However , the manufacturer reserves the right ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 3

    T able of Contents Centurion Liquid-cooled 1 5 kW and 25 kW Generators Generac ® Pow er Systems, Inc. 1 Introduction ................................Inside Front Cover Read This Manual Thoroughly ............................IFC Operation and Maintenance ................................IFC How to Obtain Service ..................................... ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 4

    2 Generac ® Pow er Systems, Inc. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to fo ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 5

    Generac ® Pow er Systems, Inc. 3 • Before performing any maintenance on the generator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step. Stepping on the unit ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 6

    4 Generac ® Pow er Systems, Inc. 1.1 GEN ER A T OR This equipment is a liquid- cooled, engine - driven generator set. The generator is designed to supply electrical power that operates critical electrical loads during utility power failure. The unit has been factory-installed in a weather resistant, all metal enclosure and is intended for outdoor ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 7

    Generac ® Pow er Systems, Inc. 5 1.5 MAI N CI RCU IT B R EAKER The generator’s main circuit breaker is included with the unit. The breaker for each unit is described in Figure 1.2. 1.6 GEN ER A T OR F U EL S YS TEM The generator has been factory tested and adjusted using a natural gas fuel system. If propane (LP requirements) gas is preferred, c ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 8

    6 Generac ® Pow er Systems, Inc. Figure 1.5- High Coolant T emperature Switch 1.7 .3 L OW C OOL ANT LEVEL SWIT CH Should engine coolant level drop below the level of the high coolant temperature switch, it is possible for the engine to overheat without automatic shutdown. T o prevent such overheating without automatic shut down, the engine has a l ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 9

    1.1 0 SP E CI F ICA TIONS 1.1 0.1 GEN ER A T OR 1.1 0.2 ENGI N E Make ................................................................Mitsubishi Displacement ..................................92 inches 3 (1.5 liters) Cylinder Arrangement ........................................4, in-line V alve Arrangement ....................................Overhe ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 10

    8 Generac ® Pow er Systems, Inc. Serious injury or damage may occur if not configured pr operly . Please consult an authorized Generac Service Dealer with any questions. 1.1 3 T ORQU E SP E CI F ICA TIONS Cylinder Head ................................15 (+ 90° + 90°) ft.lb. Intake Manifold ....................................................13 f ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 11

    Generac ® Pow er Systems, Inc. 9 NOTE: F or more information about the installation of a standby system, you can order Engine - Generator Standby Electric P ower Systems Installer’s Guide and Reference Manual (part #046622) from a Generac Authorized Service Dealer . 2.1.1 N F P A ST A N DAR D S The following published standards booklets pertaini ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 12

    10 Generac ® Pow er Systems, Inc. Figure 2.1 – Basic Standby Electric System NOTE: Generac recommends the use of a Generac P ower Systems transfer switch in conjunction with this generator . 2.5 EM ERGENCY CI RCU IT IS OL A TION M E THOD This prevents overloading the generator by keeping electrical loads below the wattage/amperage capacity of th ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 13

    Generac ® Pow er Systems, Inc. 11 2.8 GEN ER A T OR A C N EUTR AL CO N N EC T I O N S Generac uses an UNGROUNDED AC neutral. Grounding is recommended only at the main service entrance. If the neutral wire is grounded and one of the phase loads becomes grounded, the excessive current opens the load circuit breaker or collapses the generator field. ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 14

    12 Generac ® Pow er Systems, Inc. When using maintenance -free batteries, it is not necessary to check the specific gravity or electrolyte level. Have these procedures performed at the intervals specified in Section 4, “Maintenance.” A negative ground system is used. Battery connections are shown on the wiring diagrams. Make sure all batteries ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 15

    Generac ® Pow er Systems, Inc. 13 3.1 USI NG A S T AN D AR D “GT S” TR ANSF ER SWIT CH When required, the pre -packaged standby generator can be installed with an engineered Generac “GTS” type engineered automatic transfer switch. When a GTS type transfer switch is used, it controls automatic operation and automatic transfer as follows: ? ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 16

    14 Generac ® Pow er Systems, Inc. 3.2.5 7 .5 AM P I N-LI N E FUSE This in-line fuse is connected in wire 15A which runs between the A UTO/OFF/MANUAL switch and position 10 of the 076009A PCB. This fuse protects the start, fuel, field boost, and transfer outputs from the PCB and will open if there is excessive current draw on any one of these outpu ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 17

    Generac ® Pow er Systems, Inc. 15 Figure 3.3 - Engine Block Heater Refer to applicable wiring diagram(s) and electrical schematic(s) at back of manual for wiring connections. Customer supplies a 120V 15A Utility fed circuit for the block heater . 4.1 MAI NTENANCE P ER FOR M ED B Y AUTHOR IZED SERVICE F A CI LITI E S A. EVER Y TH R EE MONTHS 1. Che ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 18

    16 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Centurion Liquid-cooled 1 5 kW and 25 kW Generators Figure 4.1 - Oil Dipstick and Oil Fill Cap 4.4.2 BA T TER Y F L U I D Check battery electrolyte fluid at least once weekly . Fluid should cover separators in all battery cells. If fluid level is low , add distilled water to cover tops of ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 19

    Generac ® Pow er Systems, Inc. 17 1. Remove OIL DRAIN HOSE from its retaining clip. 2. Loosen and remove OIL DRAIN HOSE CAP . Drain oil completely into suitable container . 3. When all oil has drained, install and tighten OIL DRAIN HOSE CAP , and re -install into its retaining clip. 4. T urn OIL FIL TER (F igure 4.2) counterclockwise and remove. D ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 20

    18 Generac ® Pow er Systems, Inc. Once each year , have the generator cleaned and inspected by an Authorized Service Dealer . That dealer will use dry , low pressure air to clean internal windings. P arts inside the control console should be cleaned and inspected at this time as well. Finally , have the insulation resistance of stator and rotor wi ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 21

    Generac ® Pow er Systems, Inc. 19 1. The base frame of the unit contains an optional fuel inlet location that is capped at the factory . Check that it is secured in place. The same applies for any access ports in the roof of the enclosure. If any of these caps are missing, contact a Generac Authorized Dealer . 2. Inside the generator set, the chan ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 22

    20 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Centurion Liquid-cooled 1 5 kW and 25 kW Generators 4.9 S CH EDU LED MAI NTENANCE The following is a recommended maintenance schedule for Centurion small standby and residential generator sets. The established intervals in the schedule are the maximum recommended when the unit is used in ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 23

    Generac ® Pow er Systems, Inc. 21 Section 4 — Maintenance Centurion Liquid-cooled 1 5 kW and 25 kW Generators Maintenance Le vel 1 Le vel 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp. Required Comp . to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- mont ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 24

    22 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Centurion Liquid-cooled 1 5 kW and 25 kW Generators Maintenance Le vel 1 Le vel 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp. Required Comp . to be done (Date- 3 months/ (Date- Semi- (Date- to be done (Date- mont ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 25

    Generac ® Pow er Systems, Inc. 23 Section 5 — T roubleshooting Centurion Liquid-cooled 1 5 kW and 25 kW Generators 5.1 TROU B LE SHOO TI NG POI NTS P ROBLEM CAUSE CORR E CTION Engine won’t crank. 1. 15 amp fuse blo wn. 1. Replace fuse. 2. Loose or corroded or def ective 2. Tighten, clean or replace batter y cables . batter y cables as necessar ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 26

    24 Generac ® Pow er Systems, Inc. Section 6 — Notes Centurion Liquid-cooled 1 5 kW and 25 kW Generators ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 27

    Generac ® Pow er Systems, Inc. 25 Section 7 - Installation Diagram Centurion Liquid-cooled 1 5 kW and 25 kW Generators Drawing No. 0E1 533-A ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 28

    NB S ET EXER C I S E S WIT CH TERMINAL S TRIP 7 P OS. V O LTA G E RE GU LAT OR VR T S3 - - S W 2 - FL - SU PRE SS I O N A SS EMBL Y NE U TRAL BL OCK FA U LT LI G H T H OU R METE R F US E 1 5 AMP S FIELD BREAKER LED G EN D F T S1 FL T S2 S W 2 F1 C B 2 P CB C B 1 T S1 A S ALTERNAT O R S TAT OR - C APA C IT OR TR1 C A P GCU A S 1 2 4 X 1 1 4 1 11 44 ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 29

    Generac ® Pow er Systems, Inc. 27 Section 8 - Electrical Data Centurion Liquid-cooled 1 5 kW and 25 kW Generators Wiring Diagram — 1.5L Engine — Drawing No. 0E0343-A 4 3 2 1 5 6 9 8 1 0 11 12 CO NNE C TI ON PANEL CO NTR OL LE G EN D EH U TILITY FE D C IR CU I T T O 12 0 V / 1 5A GO VERN OR CO NTR O LLE R T O ELE C TR O NI C L OS WL S BLA CK G ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 30

    28 Generac ® Pow er Systems, Inc. Section 8 - Electrical Data Centurion Liquid-cooled 1 5 kW and 25 kW Generators Wiring Diagram — 1.5L Guardian — Drawing No. 0E1 52 5 FL 3 4 1 5 6 1 13 2 5 7 D 11 9 B A 17 16 10 12 E 4 3 15 14 GCU S W1 S W2 A LTERNATE TR1 2 2 5 N2 N1A ( BLUE ) ( RED ) A A B ( BLACK ) ( BLACK ) + - 14 S A VR S H O WN IN O FF P ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 31

    Generac ® Pow er Systems, Inc. 29 Section 8 - Electrical Data Centurion Liquid-cooled 1 5 kW and 25 kW Generators Electrical Schematic — 1.5L — Drawing No. 0A7 182-B WT S - WATER TEMPERAT U RE S WIT C H WL S - WATER LEVEL S WIT CH F S - F U EL SO LEN O I D S M - S TARTER M O T OR L OS - L O W O IL S WIT CH I SC - I G NITI O N S Y S TEM CO NTA ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 32

    ITEM P AR T NO . QTY . DESCRIPTION 1 098290 1 ASM MO T OR STEPPER 2 098941A 1 HOUSING GO VERNOR CONNECT OR 3 098958A REF CONNECT OR INTERF ACE ASSEMBL Y 4 098942A 1 CO VER CONNECTOR HOUSING 5 098225 2 SCREW FHM #2 X 5/8 SELF T AP 6 043146 3 SCREW HHC M6-1.0 X 10 G8.8 7 022097 5 W ASHER LOCK M6-1/4 8 084543A 1 SCREW PHM M3-0.5 X 12MM 9 098783 1 LEVE ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 33

    ITEM P AR T NO . QTY . DESCRIPTION 1 0D8656 1 BASE,MOUNTING 1.5L STNRD&ACSTC 2 027482 2 W ASHER SHAKEPROOF EXT 5/16 STL 3 070936 2 D AMPENER VIBRA TION 4 070936C 2 VIB. ISO. 70-75 DURO 5 039253 8 SCREW HHC M8-1.25 X 20 G8.8 6 022145 12 WASHER FLA T 5/16 ZINC 7 022129 16 WASHER LOCK M8-5/16 8 045771 4 NUT HEX M8-1.25 G8 YEL CHR 9 071956 4 W ASHE ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 34

    32 Generac ® Pow er Systems, Inc. N U T S ITEM #2 6. US E L OC TITE ON PANEL FOR ACCESS COVER E WELD S T U D U NDER R OOF 17 G R OU ND WIRE . FA S TENER T O S E CU R E US E D OO R LAT CH N O TE : 11 24 7 10 4 9 2 4 26 1 5 2 5 19 8 5 11 1 0 5 N O TE : 11 1 9 2 6 6 1 0 4 2 6 18 1 0 1 5 " Y" 2 6 14 13 1 7 2 6 11 17 1 5 1 21 24 3 2 3 22 11 2 ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 35

    ITEM P AR T NO . QTY . DESCRIPTION 1 0D8666 1 ROOF A CSTC&STND CMPR TMNT 1.5L 2 0D8664C 1 DUCT CENTER 1.5L 3 0D8657 1 SUPPORT RADIA T OR 1.5L MITSU 4 0D8660 2 BRACE SIDE 1.5L MITSU 5 0A7568 2 DOORWELDMENT 1.5EPS 6 0D8659 1 CORNER POST REAR RH SIDE 1.5L 7 0D8662 1 DOOR REAR COMP AR TMENT 1.5L 8 0D8661 1 BRACE REAR 1.5L MITSU 9 0D8658 1 CORNER PO ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 36

    34 Generac ® Pow er Systems, Inc. T YPI C AL O F FR O NT D UC T & R OOF P ANEL. S E CU RE A S S H O WN. PANEL FOR ACCESS COVER CABLE W ELD S T U D U NDER R OO F US E D OO R LAT C H NO TE: 24 38 42 7 45 36 9 43 8 10 4 1 9 3 9 18 6 22 23 1 11 5 40 25 42 1 11 11 26 4 35 3 10 3 2 "Y" 10 "Y " 14 15 17 18 1 9 15 17 3 4 2 9 3 1 21 ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 37

    Generac ® Pow er Systems, Inc. 35 ITEM P AR T NO . QTY . DESCRIPTION 1 0D8666 1 ROOF A CSTC & STND CMPR TMNT 1.5L 2 0D8664C 1 DUCT CENTER 1.5L 3 0D8657 1 SUPPORT RADIA T OR 1.5L MITSU 4 0D8660 2 BRACE SIDE 1.5L MITSU 5 0A7568 2 DOOR WELDMENT 1.5 EPS 6 0D8659 1 CORNER POST REAR RH SIDE 1.5L 7 0D8662 1 DOOR REAR COMP AR TMENT 1.5L 8 0D8661 1 BRA ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 38

    36 Generac ® Pow er Systems, Inc. Section 9 - Exploded Views and P arts Centurion Liquid-cooled 1 5 kW and 25 kW Generators Control Panel — Drawing No. 0E0 7 7 8-G A 22 28 5 1 26 29 T O 'A' 26 25 10 27 33 9 3 1 53 5 2 55 5 4 58 8 6 7 5 3 1 50 3 4 49 12 28 42 3 40 39 38 41 11 2 30 5 7 17 16 18 28 28 'A ' 2 1 56 14 38 13 40 24 ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 39

    Generac ® Pow er Systems, Inc. 37 ITEM P AR T NO . QTY . DESCRIPTION 1 0D9322 1 P ANEL BACK & BO TTOM GU ARDIAN 2 0D9332 1 P ANEL LH SIDE GUARDIAN & SPRN 3 0D9325A 1 P ANEL FRONT CONTR OL GU ARDIAN W/ SILKSC 4 0D9330 1 P ANEL RH SIDE C-P ANEL SML BRK 5 0C1457 1 HOURMETER 6 064009 1 LIGHT 12VDC .02A LED RED PILO T 7 032300 1 HOLDER FUSE 8 0 ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 40

    6 1 WATERPUMP HARDWARE 13 9 10 11 2 8 7 12 24 10 14 15 16 6 32 5 4 1 24 39 41 30 17 11 10 14 11 19 17 18 20 26 21 20 25 22 24 5 7 33 1 1 14 9 24 72 10 11 10 14 1 24 35 3 4 36 44 45 14 71 12 46 11 10 49 47 70 11 10 6 69 56 55 6 7 59 5 2 58 6 4 63 65 6 2 60 7 Section 9 - Exploded Views and P arts Centurion Liquid-cooled 1 5 kW and 25 kW Generators En ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 41

    ITEM P AR T NO . QTY . DESCRIPTION 1 0A4531 1 ENGINE-1.5L 2 022473 2 W ASHER FLA T 1/4 ZINC 4 0A45310258 1 GASKET -EXHAUST MANIFOLD 5 0A4355 1 MANIFOLD-EXHA UST 6 0E2632 1 HEA T SHIELD EXH 1.5L 7 022097 8 W ASHER LOCK M6-1/4 8 022507 2 SCREW HHC 1/4-20 X 1/2 G5 9 052212 2 SCREW HHC M10-1.25 X 25 G8.8 10 046526 4 W ASHER-LOCK-M10 11 022131 20 W ASHE ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 42

    14 11 17 28 ( BOTTOM ONLY ) "A " 28 22 9 30 3 2 29 10 2 21 1 3 2 3 35 18 14 12 33 17 34 4 TO WATER INLE T ( MIDWAY UP ENGINE BLOCK ) 14 TUBE (ON BLOCK) TO THERM OS TAT 3 1 10 23 26 8 20 WATER INLET 8 19 8 8 6 ADAPTER 12 24 7 16 7 7 15 13 TO EN G INE BYPA SS 33 3 4 11 12 Section 9 - Exploded Views and P arts Centurion Liquid-cooled 1 5 kW ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 43

    ITEM P AR T NO . QTY . DESCRIPTION 1 0D8657 1 SUPPORT RADIA T OR 1.5L MITSU 2 0A5734 1 RADIA T OR 1.5L 3 0A6237 1 VENTURI 1.5L MODINE 4 * 0A6238 1 GUARD F AN 1.5L MODINE 5 084918 1 HEA TER ENGINE 0500W 120V 6 051520N 1 TUBING 5/8 ID X 12 7 048031C 4 CLAMP HOSE BAND 1/4 8 099502 4 CLAMP HOSE #24 B1.06 - 2.00 9 083709 1 CLAMP WIRE HOSE .573 - .551 10 ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 44

    42 Generac ® Pow er Systems, Inc. 2 9 33 32 31 1 8 2 0 1 0 1 9 L.P. VAP OR P O R T " OU T 2 " 41 4 0 11 14 9 " C" 12 14 1 6 17 8 4 3 1 5 " D" 4 5 27 42 2 3 2 7 6 4 0 21 39 36 38 2 8 30 34 24 2 5 6 6 41 26 37 35 22 1 3 ( NATURAL GAS ) " OU T 1 " P O R T 41 3 11 " D" Section 9 - Exploded Views and P ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 45

    Generac ® Pow er Systems, Inc. 43 ITEM P AR T NO . QTY . DESCRIPTION 1 * --------- 1 WELDMENT MOUNTING BASE 2 075580 1 FLANGE FUEL INLET 3 0E1006 1 ASSY REGULA T OR 1.5L N.G.OR LPV 4 039253 2 SCREW HHC M8-1.25 X 20 G8.8 5 022145 2 W ASHER FLA T 5/16 ZINC 6 022129 6 W ASHER LOCK M8-5/16 7 045771 2 NUT HEX M8-1.25 G8 YEL CHR 8 0A7040 1 BRACKET -RAD ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 46

    44 Generac ® Pow er Systems, Inc. 8 36 13 3 12 5 9 15 14 17 T o Blow e r H ousin g 3 2 2 3 24 35 1 21 28 7 22 33 10 29 16 30 18 2 6 19 20 3 1 2 1 4 T o En g ine C rankshaf t 26 Section 9 - Exploded Views and P arts Centurion Liquid-cooled 1 5 kW and 25 kW Generators Alternator — Drawing No. 0A93 48-F ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 47

    Generac ® Pow er Systems, Inc. 45 ITEM P AR T NO . QTY . DESCRIPTION 1 098671 1 ASSY RO TOR 10KW 098681 1 ASSY RO TOR 15KW 098675 1 ASSY RO TOR 20KW 098936 1 ASSY RO TOR 25KW 2 0A5336A 1 HOUSING BLOWER 3 0A1659 1 SCREEN AIR OUTLET 4 071912 4 SCREW PPHM M5-0.8 X 8 SS 5 049226 4 W ASHER LOCK M5 6 051713 4 W ASHER FLA T M5 7 022129 4 W ASHER LOCK M8- ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 48

    ITEM P AR T NO . QTY . DESCRIPTION 1 077483 1 BA TT 12VDC 75-AH 26 2 038804D 1 CABLE BA TT RED #4 X 20.00 3 038805B 1 CABLE BA TT BLK #4 X 23.00 4 0742600131 1 ASSY ,WIRE#16 RED 1.6 5 022131 1 W ASHER FLA T 3/8 ZINC 6 046526 1 W ASHER LOCK M10 7 052213 1 SCREW HHC M10-1.25 X 20 G8.8 8 075763 3 BOO T , BA TTER Y CABLE 9 0D8668 1 BRACKET , BA TTER Y ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 49

    Generac ® Pow er Systems, Inc. 47 ITEM P AR T NO . QTY . DESCRIPTION 1 0A4355 1 MANIFOLD EXHAUST 1.5L 2 0E2844 1 NIPPLE T OE 1.5NPTX5.5 BLK IRON 3 036434 3 BOL T U 5/16-18 X 2.09 036449 3 SADDLE 2 INCH 4 0E0109 1 PIPE,EXHAUST 1.5L STNDRD&A CSTC 5 0C1318 1 FLEX PIPE EXHA UST 6 0D8657 1 SUPPORT , RADIA T OR 1.5L MITSU 7 0E0170 1 BLANKET , EXHA U ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 50

    48 Generac ® Pow er Systems, Inc. CALI FOR N IA EM ISSION C ONTROL W AR R ANT Y ST A TEM ENT Y OU R W AR R ANT Y R IGHT S AN D OBLIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine. * In California, new utility , and lawn and ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 51

    Generac ® Pow er Systems, Inc. 49 EM IS SION CONTROL S YS TEM W AR R ANT Y Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines. The ECS W arranty P eriod shall begin on the date the new engine or equipment is purchased by/delivere ...

  • Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - page 52

    Part No. 0E5129 Revision G (12/20/04) Printed in U.S.A. Section 1 0 – Warranty Centurion Liquid-cooled 1 5 kW and 25 kW Generators GENER AC PO WER SY STEMS "TWO YEAR" LI MITED W AR RANT Y FOR CENTU R ION "PR EP ACKAGED EMERGENCY AUT OMA TIC ST AN DBY GENER A T ORS" F or a period of two years from the date of original sale, Gen ...

Manufacturer Generac Category Portable Generator

Documents that we receive from a manufacturer of a Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 can be divided into several groups. They are, among others:
- Generac technical drawings
- 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 manuals
- Generac product data sheets
- information booklets
- or energy labels Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2
All of them are important, but the most important information from the point of view of use of the device are in the user manual Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2, service manual, brief instructions and user manuals Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2.

A complete manual for the device Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2.

A complete Generac manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2, that we can find in the current document
3. Tips how to use the basic functions of the device Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 - which should help us in our first steps of using Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2?

Use the form below

If you did not solve your problem by using a manual Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2, ask a question using the form below. If a user had a similar problem with Generac 004912-0, 004912-1, 004913-0, 004913-1, 004913-2 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)