    OPERA TING AND INST ALLA TION INSTRUCTIONS Models 185, 265, 335, 405 Swimming Pool and S pa Heaters 181/182, 260/261, 330/331, 400/401 W ater Heaters and Boilers D-2 POWER VENT (FOR ELECTRONIC IGNITION MODELS ONLY) CATALOG NO. 6000.57D Effective: 10-26-06 Replaces: 03-15-03 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and ...

  • Raypak 405 - page 2

    POWER VENT ASSEMBL Y INST ALLA TION, ST ART -UP AND OPERA TION 1. RECEIVING EQUIPMENT On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the complete assembly from the carton if ...

  • Raypak 405 - page 3

    3 3. INSTALLATION REQUIREMENTS The equipment must be installed in accordance with local codes, or in the absence of local codes with the latest edition of the National Fuel Gas Code, ANSI Z223.1, the National Electrical Code, ANSI/NFPA 70. The equipment shall be installed in accordance with those installation regulations in force in the local area ...

  • Raypak 405 - page 4

    4 WIRING A POWERVENT ASSEMBL Y TO AN APPLIANCE WITH IID IGNITION. W ARNING : Disconnect all electrical power to the unit before servicing to avoid potential shock injury or damage to the unit. T o change voltages, follow wiring diagram for correct voltage connections. Improper wiring connections can burnout the relay and blower motor . ** NOTE: The ...

  • Raypak 405 - page 5

    VENTING The vent pipe must be the same size or larger than what is indicated. The D-2 Power V ent are capable of 360-degree discharge rotation and operate with a positive vent st atic pressure and with a vent gas temperature less than 400°F . The tot al length of horizontal run shall not exceed an equivalent of 40 feet including termination cap. F ...

  • Raypak 405 - page 6

    6 The Raypak Power Vent operates with a positive vent static pressure and with a vent gas temperature that avoids excessive condensate production in the vent and as such it is listed as a CATEGORY III appliance. Exception: When a Power Vent is connected to a vertical vent of sufficient height to generate a negative draft in the system. Consult sizi ...

  • Raypak 405 - page 7

    7 185-405 POOL HEA TER (A TMOSPHERIC) ...

  • Raypak 405 - page 8

    8 185-405 POOL HEA TER ( Low NOx) ...

  • Raypak 405 - page 9

    9 182-260 WH1 (A TMOSPHERIC) ...

  • Raypak 405 - page 10

    181-261 WH1 (Low NOx) 10 ...

  • Raypak 405 - page 11

    SEQUENCE OF OPERA TION On call for heat, the D-2 Power Vent fan (and appliance pump) start. When the flow switch circuits close, the ignition system consisting of an electronic spark module, pilot gas system and flame sensor, are energized. When draft proving switch closes and all safety circuits are proven, the automatic main gas valves will open ...

  • Raypak 405 - page 12

    START UP PROCEDURES The water system, the gas system and the electrical system for the heater should be completed and checked as per the heater installation manual and associated documents. 1. Turn on power to the heater with the manual main gas valve and pilot gas valve off. The electric power supply requirements are: • Dual-voltage fan motor. 1 ...

  • Raypak 405 - page 13

    ILLUSTRA TED P ARTS LIST 13 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

  • Raypak 405 - page 14

    Raypak, Inc. , 2151 Eastman Avenue, Oxnard, CA 93030 (805) 278-5300 FAX (800) 872-9725 Raypak Canada LTD , 2805 Slough Street, Mississauga, Ontario, Canada L4T 1G2 (905) 677-7999 FAX (905) 677-8036 Raypak Australia Pty. Ltd , 7 Geddes St., Mulgrave, Victoria, Australia 3170 (6139) 560 4944 FAX (6139) 560 4974 Litho in U.S.A. www .raypak.com ...

Manufacturer Raypak Category Water Heater

Documents that we receive from a manufacturer of a Raypak 405 can be divided into several groups. They are, among others:
- Raypak technical drawings
- 405 manuals
- Raypak product data sheets
- information booklets
- or energy labels Raypak 405
All of them are important, but the most important information from the point of view of use of the device are in the user manual Raypak 405.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Raypak 405, service manual, brief instructions and user manuals Raypak 405. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Raypak 405.

Similar manuals

A complete manual for the device Raypak 405, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Raypak 405 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Raypak 405.

A complete Raypak manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Raypak 405 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Raypak 405, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Raypak 405, that we can find in the current document
3. Tips how to use the basic functions of the device Raypak 405 - which should help us in our first steps of using Raypak 405
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Raypak 405
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Raypak 405 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Raypak 405?

Use the form below

If you did not solve your problem by using a manual Raypak 405, ask a question using the form below. If a user had a similar problem with Raypak 405 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)