    Operation Manual LASER RANGE FINDER MODULE LRF MOD 4EC 105 Spa rks Ave., Toronto, ON, M2H 2S5 , Canada ...

  • Newcon Optik LRF MOD 4EC - page 2

    ii ...

  • Newcon Optik LRF MOD 4EC - page 3

    iii IMPORTANT INFORMATION Read prior to activation You have ju st purchased a s ophisticated ele ctro-optical de vice that emits i nvisible laser radiation. To operate it properly, please read this manual carefully. • NEVE R direct laser beam at the eyes of people or anim als • NEVE R aim the unit at the Sun or bri ght sources o f light • NEV ...

  • Newcon Optik LRF MOD 4EC - page 4

    1 CONTENTS 1. BRIEF DESCRIPTIO N ............................................ 3 1.1 Principle of work ................................................. 4 1.2 Key Feat ures ........................................................ 4 2. DEVICE APPE ARANCE ........................................ 5 3. DELIVERY S ET ..................................... ...

  • Newcon Optik LRF MOD 4EC - page 5

    2 5.14 Additional display inform ation .......................... 22 6. BEST MEASURI NG TECHNIQUE ...................... 23 7. Interconnecti vity ..................................................... 25 7.1 Connecting to com puter ..................................... 25 7.2 Data output protoc ol .......................................... 25 7.3 Ad ...

  • Newcon Optik LRF MOD 4EC - page 6

    3 CAREFULLY READ ALL THE I NSTRUCTION S BEFORE USING! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANT Y AND MAY CAUSE INJURY! 1. BRIEF DESCRIPTION The LRF Modules use the sa me electronics and optics as rangefinder m onoculars an d binoculars . These m odules can add various range finding capabilities in to host systems: distance & speed ...

  • Newcon Optik LRF MOD 4EC - page 7

    4 Principle of work The Modules send invisible, eye safe laser pulses to the targ et. Pulses reflected from the target are captured and processed by the digital circuitry. The time-of-flig ht delay between the sent and received pulses allows calculating the distanc e to the target. A built-in digital compass/inclinometer of MOD 4EC measures target? ...

  • Newcon Optik LRF MOD 4EC - page 8

    5 2. DEVICE APPEARANCE 1 – Communication connector 2 – Detachable eye-piece 3 – LRF cover 4 – Desiccator 5 – Optical window 6 – Detachable camera 5 3 1 2 Fig. 1. MOD 4EC general vi ew 4 6 ...

  • Newcon Optik LRF MOD 4EC - page 9

    6 1 – Low battery indi cator 2 – Reticle (either -¦- or  ) 3 – Units of measurement 4 – Measurem ent result 5 – Target q uality indicat or 6 – Laser activ e indicator 7 – Gating i ndicator 8 – Setup m ode indicator 9 – Ready mode indicat or Fig. 2. Liquid Crystal Display view through the eyepiece 4 6 2 7 1 5 3 9 8 ...

  • Newcon Optik LRF MOD 4EC - page 10

    7 3. DELIVERY SET Standard delivery set The unit is supplied in the follo wing assembly: Qty LRF MOD 4E C 1 Eyepiece 1 USB camera 1 Compact disk with soft ware 1 Computer/power cable 1 Operation m anual 1 Warranty card 1 Hard case 1 Connectors: Data/power c onnector LEMO Push-P ull Connector FGG.0B.30 9.CLAD52 Data and powe r connectors can be m od ...

  • Newcon Optik LRF MOD 4EC - page 11

    8 4. SPECIFICATIONS Range Finder Laser Measuring range Accuracy First, last and auto target selection Meters/Yards display Last 10 readings recall Reticle Target quality indicator Class 1, eye safe, 905 nm 16 m – 4, 000 m ± 1 m Yes Yes Yes -¦- or  Yes Gating capability, m 100 - 7,000; 100 m step Speed measurement Measured speed ran ge 5 – ...

  • Newcon Optik LRF MOD 4EC - page 12

    9 Interface RS 232 interface. Power External power requirement 9V DC, 300 m A The unit is fully operational when voltage is higher than 7V. A ‘ LOW BATTERY’ warning is displayed when voltage falls below 7.2V. Environmental Operational temperature range Storage temperature range -25 / +50ºC (- 13 / +122ºF) -45 / +65ºC (- 49 / +149ºF) Mechani ...

  • Newcon Optik LRF MOD 4EC - page 13

    10 5. OPERATION INSTRUCTIONS Maximum distance Though ma ximum measurem ent distance dep ends on target reflectivity, we ather condit ions and othe r conditions , for most targets the unit will provide accurate rang ing for up to 3,000 meters. In good conditions a highly reflective targ et can be measured up to 4,000 meters. Target reflectivity depe ...

  • Newcon Optik LRF MOD 4EC - page 14

    11 The correspondence betwee n the pr essing of t he buttons and t he signals sent via RS-232 is described i n Interconnectivity, cha pter 7. The rest of t his manual descri bes measurement p rocedures and setting m easurement param eters through pressing of t he buttons. Measurement procedure When the Module is off the LCD is blank. To activate it ...

  • Newcon Optik LRF MOD 4EC - page 15

    12 Target selection logic On its way towards the ta rget, laser beam m ay reflect from various ob jects, thus decreasi ng ranging accuracy . The smal ler, the farther, and the less reflective is the target – the higher is the possibility of obtain ing an incorrect measurement. To improve accuracy the unit has a built-in target selection logic, wh ...

  • Newcon Optik LRF MOD 4EC - page 16

    13 To activate the Scan ning regi me press and h old the A butto n in Ready mode. The unit will work in the Scanning regime while the A button is pressed. Scanning or Individual Measurement regimes are available for any selected mode of m easurement. When two param eters are measured in the Sc anning regime though both will be quickly displayed, th ...

  • Newcon Optik LRF MOD 4EC - page 17

    14 2. In what units result of distance measurement is displayed: meters or y ards, degrees or m ils, km/ h or mph, 3. What reticle shape is visible: rectangular or crosshair, and 4. Which target is selected: first, last or most reflective (see the Target selection logic (5.4) for more details). The Setup mode is described in more detail below. The ...

  • Newcon Optik LRF MOD 4EC - page 18

    15  Quick lin k to the Standa rd1 set of measurement param eters (display nam e: Std1 ),  Quick lin k to Standa rd2 set of m easurement param eters (display nam e: Std2 ),  Setup m ode (display name: COdE ),  Gating mode (display name: GAt ),  Data Recall mode (dis play name: rEc ),  Memory Clearance m ode (display nam e: cLr ), ? ...

  • Newcon Optik LRF MOD 4EC - page 19

    16 Note: On a spe cial request a menu of a particular unit can be simplified to show only required modes. Setup mode To modify t he Ready to Measure mode para meters:  Enter the Set up mode. Wit h wor d Ready on the display press th e M button till display nam e COdE is displayed and pr ess the A button.  Select the desir ed parameter m odifi ...

  • Newcon Optik LRF MOD 4EC - page 20

    17 Mode Display name Distance Speed Azimuth Elevation Reticle Target selection logic Setup COdE Entrance into the Setup mode Cd 1 M m NC Cd 2 Y yd NC Cd 3 - ◦ Deg NC Cd 4 - Mils NC Cd 5 - ◦ Deg NC Cd6 - Mils NC Cd7 - m NC Cd 8 - yd Deg Deg -¦- Auto Cd 9 -¦- NC -¦- NC Cd 10  NC  NC Cd 11 NC Last Cd 12 NC First Cd 13 NC Auto Cd 14 KMH NC ...

  • Newcon Optik LRF MOD 4EC - page 21

    18 Mode Display name Distance Speed Azimuth Elevation Reticle Target selection logic Cd 16 Display test Cd 17 Compass calibration Gating GAt Entrance into gating mode Data Recall rEc Recalls last 10 measurement sets Data Clearance cLr Clears all recorded data Interface format -PC- or PLGr Selects PC or PLGR data format for output port Empty field m ...

  • Newcon Optik LRF MOD 4EC - page 22

    19 Compass calibrat ion If the Module was exposed to a strong magnetic field or was not in use for a long time, the com pass accuracy may diminish. To bring the compass into working condition:  Select Cd 17 in the Setup mo de  Keeping the unit horizontally, perform one full rotation around vertical axis within ha lf a minute and then one full ...

  • Newcon Optik LRF MOD 4EC - page 23

    20  Pressing the A button will activate shown on th e LCD communicat ion format. Gating mode In this mode the gating function is activated : user can set the minimal distance to the targ et; reflection from any object closer than the gating distance will be ignored. The Gating feature helps m easuring remot e targets in adve rse atmospheric and ...

  • Newcon Optik LRF MOD 4EC - page 24

    21 Data Recall mode In the Data Recall mode results of the last 10 m easurements can be displayed. Measurement results are save d in on-board memory in sets depending on the paramete rs set for measuring , for instanc e, if only distance is measured - the set will consist of one number, if distance and azimuth are measured – the set will consist ...

  • Newcon Optik LRF MOD 4EC - page 25

    22 Display test mode Selecting Code 16 in the Setup mode will cause all display segments and i ndicators to flash for 8 second s. Additional display inform ation Additional i ndication i s displaye d in the Ready to Measure mode: Y or M Indicates that distance is measured and displayed in yards or meters KMH or MPH Indicates that speed is measured ...

  • Newcon Optik LRF MOD 4EC - page 26

    23 6. BEST MEASURING TECHNIQUE Laser range finder m odule measures distance by catchi ng a laser beam reflected from the targ et. Everyt hing that im proves reflection increases the measurement reliability and maximum range. 1. Aim at a surfac e on the targ et that is closest to the perpendicul ar to the laser beam. The closer you get – the stron ...

  • Newcon Optik LRF MOD 4EC - page 27

    24 distance estimation to cut off all objects closer tha n the chosen one. Note: the Gating setting is remembered by the System until altered. Therefore, if you forget to turn the gating off, the next time you start measuring it can ignore th e desired object, if it is closer than the gating distance. Th e unit will display four dashes instead of t ...

  • Newcon Optik LRF MOD 4EC - page 28

    25 7. Interconnectivity The unit supports RS-232 inte rface. Physical connection is performed through a connector specific to ea ch order. The default connectors are described i n Specificati ons. Connecting to computer The communication port must be initiated prior to connecting th e unit. Data is transm itted as a he x string code with fixe d bau ...

  • Newcon Optik LRF MOD 4EC - page 29

    26 The data stri ng has the follo wing structure (in Hex): b1 b2 b3 E4h b5 E 4h 0Dh 0Ah, where: b1 – type of measurement; b2 – sign of measurement ( 1 – minus, 2 – plus); b3 – LSB of result; b5 – MSB of result Result of measurement = MSB * 256 + LSB In both standar d modes, when t h ree parameters a re measured, the module will generate ...

  • Newcon Optik LRF MOD 4EC - page 30

    27 b11 – MSB of the res ult for the second type of measurement b15 – LSB of the resu lt for the third type of measurement b17 – MSB of the result for the third typ e of measurement Marker E4h is used to sepa rate num bers, 0Dh 0Ah – t o separate data sets. Type of measurem ent (bytes b1, b7, b13) can have the following value: 1 – Distance ...

  • Newcon Optik LRF MOD 4EC - page 31

    28 S1 – first sym bol of the st atus menu S2 – second sy mbol of t he status menu S3 – third sy mbol of the status m enu or 21h S4 – 21h or 00h Examples of t he LRF menu o utput: Output, Hex Output, ASCII LRF menu position 53h 54h 31h 21h 0Ah 0Dh ST1! <LF><CR> Standard 1 43h 4Fh 44h 21h 0Ah 0Dh COD! <LF><CR> Code 47h ...

  • Newcon Optik LRF MOD 4EC - page 32

    29 Output, Hex Output, ASCII LRF menu position 43h 31h 32h 21h 0Ah 0Dh C12! <LF><CR> Code 12 47h 32h 34h 21h 0Ah 0Dh G24! <LF><CR> Gating over 2400 m Output connector pin l ayout and cable di agram By default f or the output c onnector the m odule uses the connector as described in Sp ecifications. Thi s connector withstands ...

  • Newcon Optik LRF MOD 4EC - page 33

    30 Figure 4. Cable diagram Connector and cable layou t can be modified for speci fic customer needs. GPS interconnectivity The Modules can transmit the acquired data to a GPS receiver using the sam e output connec tor and the PL GR/DAGR pro tocol. ...

  • Newcon Optik LRF MOD 4EC - page 34

    31 Another cabl e is required a nd can be suppli ed as an option. To work with GPS, perform th e following steps:  Switch to PLGr mode;  Choose either Std1 or Std2 measuring mode;  Connect the unit to and the GPS unit with the cable. For each measurement the GPS unit will display th e absolute coordinates of y our target. Note: If the modu ...

  • Newcon Optik LRF MOD 4EC - page 35

    32 8. STORAGE AN D MAINTENANCE The unit is a s ophisticated p recision opt ical instrument equipped with laser and electronics. Ther efore, it should be handled with due care. • Keep away from direct sunlight. • Avoid impacts, jolts, dust, moisture, and sharp changes of temperature. • Do not use the device at tem peratures higher than 50 o C ...

  • Newcon Optik LRF MOD 4EC - page 36

    33 9. TROUBLESHOOTING Ranging does not work. Display is transparent. Check the power supply. Ranging does not work. Display indicates results of the last measurement. Wait for 8 seconds until the display becomes transparen t, and press the Actio n button again. Black dots are visible on LCD. Liquid Cryst al Display m ay have small black dots, scrat ...

  • Newcon Optik LRF MOD 4EC - page 37

    34 10. WARRANTY NEWCON warrants this product against defects in material and workmanshi p for one year f rom the date of the original pu rchase, but no m ore than 18 m onths from t he date of m anufacturing. Longer warranty is available, subject to the terms of the specific sales contract. Should your Newcon product pr ove to be defective during th ...

  • Newcon Optik LRF MOD 4EC - page 38

    35 11. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OPTIK product, consult the enclo sed manual. If the problem remains unresol ved, contact our cust omer suppo rt department at (416) 663-6963 or toll free at 1-877-368-666 6. Our operating hours are 9am -5pm, Monday - F riday, Eastern Standar d Time. At no time sho uld ...

  • Newcon Optik LRF MOD 4EC - page 39

    36 12. QUALITY CERTI FICATE MOD 4EC The unit has passed the quality inspection. Production date Serial number Quality Inspector Purchase date ...

  • Newcon Optik LRF MOD 4EC - page 40

    NEWCON OPTIK ™ 2010 ...

Manufacturer Newcon Optik Category Hunting Equipment

Documents that we receive from a manufacturer of a Newcon Optik LRF MOD 4EC can be divided into several groups. They are, among others:
- Newcon Optik technical drawings
- LRF MOD 4EC manuals
- Newcon Optik product data sheets
- information booklets
- or energy labels Newcon Optik LRF MOD 4EC
All of them are important, but the most important information from the point of view of use of the device are in the user manual Newcon Optik LRF MOD 4EC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Newcon Optik LRF MOD 4EC, service manual, brief instructions and user manuals Newcon Optik LRF MOD 4EC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Newcon Optik LRF MOD 4EC.

A complete manual for the device Newcon Optik LRF MOD 4EC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Newcon Optik LRF MOD 4EC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Newcon Optik LRF MOD 4EC.

A complete Newcon Optik manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Newcon Optik LRF MOD 4EC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Newcon Optik LRF MOD 4EC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Newcon Optik LRF MOD 4EC, that we can find in the current document
3. Tips how to use the basic functions of the device Newcon Optik LRF MOD 4EC - which should help us in our first steps of using Newcon Optik LRF MOD 4EC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Newcon Optik LRF MOD 4EC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Newcon Optik LRF MOD 4EC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Newcon Optik LRF MOD 4EC?

Use the form below

If you did not solve your problem by using a manual Newcon Optik LRF MOD 4EC, ask a question using the form below. If a user had a similar problem with Newcon Optik LRF MOD 4EC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)