Manual Goodman Mfg SS-CPH90-150

36 pages 1.4 mb
Download

Go to site of 36

Summary
  • Goodman Mfg SS-CPH90-150 - page 1

    SS-CPH90-150 ww w .goodmanmfg.c om 6/11 Supersedes 3/11 Standard Featur es • R-410Achlorine -freerefrigerant • High- eciencyscrollcompressor • Coppertube/aluminumncoils • Contactorwithlugs • High- capacity,st eel- casedlterdryer • Single -pointentry • 24-volt? ...

  • Goodman Mfg SS-CPH90-150 - page 2

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCa tionS 2 ww w .goodmanmfg.c om SS-CPH90-150 n omenCla ture  C P H 090 045 3 B X X X           Brand F actoryInstalledOp<ons      ? ...

  • Goodman Mfg SS-CPH90-150 - page 3

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCa tionS SS-CPH90-150 ww w .goodmanmfg.c om 3 P roduCt S PeCifiCa tionS — 7½ t onS CPH090 ***3B*** CPH090 ***4B*** CPH090 ***7B*** Cooling Cap a city T otal BTU/h 90,000 90,000 90,000 Sensible BTU/h 65,700 65,700 65,700 EER / IEER 11.5 / 11.2 11.5 / 11.2 11.5 / 11.2 IPL V 12.30 12.30 12.30 Decibels 83 8 ...

  • Goodman Mfg SS-CPH90-150 - page 4

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 4 ww w .goodmanmfg.c om SS-CPH90-150 P roduCt S PeCifiCa tionS — 8½ t onS CPH102 ***3B*** CPH102 ***4B*** CPH102 ***7B*** Cooling Cap acity T otal, BTU/h 102,000 102,000 102,000 Sensible BTU/h 73,440 73,440 73,440 EER / IEER 11.1 / 11.2 11.1 / 11.2 11.1 / 11.2 Decibels 83 83 83 ARI Ref erence #s ...

  • Goodman Mfg SS-CPH90-150 - page 5

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 5 P roduCt S PeCifiCa tionS — 1 0 t onS CPH120 ***3B*** CPH120 ***4B*** CPH120 ***7B*** Cooling Cap acity T otal BTU/h 118,000 118,000 118,000 Sensible BTU/h 87,300 87,300 87,300 EER / IEER 11.5 / 11.5 11.5 / 11.5 11.5 / 11.5 Decibels 83 83 83 Hea ting Cap acity ...

  • Goodman Mfg SS-CPH90-150 - page 6

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 6 ww w .goodmanmfg.c om SS-CPH90-150 P roduCt S PeCifiCa tionS — 12½ t onS CPH150XXX 3BXXX CPH150XXX 4BXXX CPH150XXX 7BXXX Cooling Cap acity T otal, BTU/h 146,000 146,000 146,000 Sensible BTU/h 102,200 102,200 102,200 EER / IPL V 10.8 / 11.2 10.8 / 11.2 10.8 / 11.2 Decibels 83 83 83 ARI Ref eren ...

  • Goodman Mfg SS-CPH90-150 - page 7

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 7 e xP anded H eating d a ta CPH090 Outdoor Ambient Temper a ture 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 114.4 108.3 101.9 95.3 91.0 88.2 81.9 75.5 70.5 65.0 59.9 56.6 54.5 48.9 43.3 37.8 32.2 26.4 T/ R 35.3 33.4 31.5 29.4 28.1 27.2 25.3 23.3 21. ...

  • Goodman Mfg SS-CPH90-150 - page 8

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 8 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 7½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 3375 MBh 88.2 91.4 100.2 - 86.1 89.3 97.8 - 8 ...

  • Goodman Mfg SS-CPH90-150 - page 9

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 9 e xP anded C ooling d at a — 7½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 3375 MBh 91.3 93.3 99.7 106.5 89.2 ...

  • Goodman Mfg SS-CPH90-150 - page 10

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 10 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 8½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 3820 MBh 100.0 103.6 113.5 - 97.6 101.2 110. ...

  • Goodman Mfg SS-CPH90-150 - page 11

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 11 e xP anded C ooling d at a — 8½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 3820 MBh 103.5 105.7 112.9 120.7 1 ...

  • Goodman Mfg SS-CPH90-150 - page 12

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 12 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 1 0 t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 4500 MBh 115.6 119.8 131.3 - 112.9 117.1 128 ...

  • Goodman Mfg SS-CPH90-150 - page 13

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 13 e xP anded C ooling d at a — 1 0 t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 4500 MBh 119.7 122.3 130.7 139.7 1 ...

  • Goodman Mfg SS-CPH90-150 - page 14

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 14 ww w .goodmanmfg.c om SS-CPH90-150 e xP anded C ooling d at a — 12½ t onS Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 4725 MBh 143.1 148.3 162.5 - 139.7 144.8 15 ...

  • Goodman Mfg SS-CPH90-150 - page 15

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 15 e xP anded C ooling d at a — 12½ t onS ( Cont .) Outdoor Ambient Temper a ture 65 75 85 95 105 115 Entering Indoor Wet Bulb Temper a ture IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 80 4725 MBh 148.1 151.3 161.7 172.8 ...

  • Goodman Mfg SS-CPH90-150 - page 16

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 16 ww w .goodmanmfg.c om SS-CPH90-150 a irfl ow d a ta — 7½ t onS St andard Bel t Drive — Down Sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.1 3617 704 1.07 3293 653 0.84 0.3 3541 749 1.15 3179 704 0.88 2757 656 0.66 0.5 3447 ...

  • Goodman Mfg SS-CPH90-150 - page 17

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 17 a irfl ow d a ta — 8½ t onS St andard Bel t Drive — Down Sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.1 3467 701 1.04 3143 650 0.81 0.3 3391 746 1.12 3029 701 0.85 2607 653 0.63 0.5 3297 ...

  • Goodman Mfg SS-CPH90-150 - page 18

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 18 ww w .goodmanmfg.c om SS-CPH90-150 a irfl ow d a ta — 1 0 t onS St andard Bel t Drive — Down sho t ESP , In H 2 O T urns Open 012345 CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP CFM RPM BHP 0.2 4629 774 1.76 4269 733 1.42 0.4 4539 824 1.86 4198 781 1.53 3797 735 1.21 0.6 4511 ...

  • Goodman Mfg SS-CPH90-150 - page 19

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 19 a irfl ow d a ta — 12½ t onS St andard Bel t Drive --- Down Sho t ESP (in W .C.) T urns Open 0 1 2 3 4 5 CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 0.2 5378 2.35 4967 1.92 4710 1.59 4512 1.33 0.4 5514 2.92 5349 2.56 4750 1.97 4583 1.71 4319 1.40 4030 1. ...

  • Goodman Mfg SS-CPH90-150 - page 20

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 20 ww w .goodmanmfg.c om SS-CPH90-150 H ea t k it e leCtriCal d a t a — 7½ t onS m inimum a irflow for e leCtriC H ea t Hea ter Size (kW) Minimum CFM 15 3,000 30 3,000 43 3,000 kW Correction F actor f or 3-Phase Units Suppl y Vol t age 240 230 220 210 208 Correction F actor 1 0.93 0.82 0.78 0.76 ...

  • Goodman Mfg SS-CPH90-150 - page 21

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 21 H ea t k it e leCtriCal d a t a — 8½ t onS Model and Hea t Kit Usage MCA¹ a t 240V MOP² (amps) a t 240V Actu al kW a t 240V Recommended Airflow Range (Downsho t) Recommended Airflow Range (Horizont al) CPH102***3B*** 43 50 EHK3-16 88 90 15 3400 - 3825 CFM ...

  • Goodman Mfg SS-CPH90-150 - page 22

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 22 ww w .goodmanmfg.c om SS-CPH90-150 H ea t k it e leCtriCal d a t a — 1 0 t onS k w C orreCtion f aCt or kW Corre ction Fa ctor (for 1- & 3-Pha se Units) Supply V oltage 240 230 220 210 208 Correcon F actor 1 0.93 0.82 0.78 0.76 kW Corre ction Fa ctor for 480V Unit s Actual V oltage 460 ...

  • Goodman Mfg SS-CPH90-150 - page 23

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 23 H ea t k it e leCtriCal d a t a — 12½ t onS kW Corre ction Fa ctor for 1- & 3-Pha se Units Suppl y V ol t age 240 230 220 210 208 Corre ction Fa ctor 1 0.93 0.82 0.78 0.76 kW Corre ction Fa ctor for 480V Unit s Suppl y V ol t age 460 440 430 Corre ction ...

  • Goodman Mfg SS-CPH90-150 - page 24

    P roduct S Pecifica tionS P roduct S PecificationS 24 ww w .goodmanmfg.c om SS-CPH90-150 d imenSionS 20 APPENDIX C UNIT DIMENSIONS Horizontal Discharge Vertical Discharge (Bottom of Unit) RETURN SUPPL Y 13 7/ 8” 28 3/ 8” 7 3/8” 12 5/ 8” 6 1/4 ” 36 3/ 8” 5 7/8 ” RETURN SUP PL Y 5 3/8” 7 1/2” 6 1/2” 99 1/ 8” 61 3/ 4” Y NOTE Fo ...

  • Goodman Mfg SS-CPH90-150 - page 25

    P roduct S Pecifica tionS P roduct S PecificationS SS-CPH90-150 ww w .goodmanmfg.c om 25 48” 36” Min. 48” 48” 75” u nit c learanceS e lectrical e ntrance l oca tionS 11⅝” 10 3 / 16 ” 3” Low -V oltage Entr ance High-V oltage En trance Dimples Mark Drill Locaons Maintain an adequate clearance around the unit for saf ety, service, ...

  • Goodman Mfg SS-CPH90-150 - page 26

    P roduct S Pecifica tionS P roduct S PecificationS 26 ww w .goodmanmfg.c om SS-CPH90-150 r oof c urb i nSt alla tion — r igging Pr ovisions for forks hav e been included in the unit base frame. No other fork locations are appr oved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables shoul ...

  • Goodman Mfg SS-CPH90-150 - page 27

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 27 r oof C urB i nSt alla tion ( Cont .) Curb installations must comply with local codes and should follow the establishedguidelinesoftheNationalRoongContractorsAssociation. Pr operunit installation ...

  • Goodman Mfg SS-CPH90-150 - page 28

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 28 ww w .goodmanmfg.c om SS-CPH90-150 w iring d ia gram — CPH090- 120***3B/ 4B ( for modelS witH Serial numBerS 090 7 and Below ) Wiring is subject to change. Alwa ys ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W arning High Volt age:   ...

  • Goodman Mfg SS-CPH90-150 - page 29

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 29 w iring d ia gram — CPH090- 120***3B/ 4B ( Cont .) ( for modelS witH Serial numBerS 090 7 and Below ) Wiring is subject to change. Alwa ys ref er to the wiring diagram or the unit for the most up-t o-date wiring. ⚠ W arning High Volt age:  ? ...

  • Goodman Mfg SS-CPH90-150 - page 30

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 30 ww w .goodmanmfg.c om SS-CPH90-150 w iring d ia gram — CPH090- 120***3B/ 4B/ 7B*** TB1 OR BR REPLACE JUMP ER WI TH SMOKE/FIRE DETECTOR RD C 3 BL 1 PK 240 460 BL OR RD GR BK OR RD OR RD RD RD 6 GND COM HVDR R DFT1 L3 BK T3 YL NOTE 3 PLF NC NO BK UP RD GR BK 2 C WH C 8 L2 K1 BK BR DF2 C YL SPEED ...

  • Goodman Mfg SS-CPH90-150 - page 31

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 31 w iring d ia gram — CPH090- 120***3B/ 4B/ 7B*** ( Cont .) R EBTDR BC R HVDR Y RVC1 SEE UNIT RATING PLATE FOR TYPE AND SIZE 5 OF OVER CU RRENT PROTECTION 4 BLOW ER CONTACTOR COMPRESSOR CONTACTOR CONDENSER MOT OR CONDENSER M OTOR CONTACTOR COMPRESSOR DEFROST CO ...

  • Goodman Mfg SS-CPH90-150 - page 32

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 32 ww w .goodmanmfg.c om SS-CPH90-150 TB1 OR BR REPLACE JUMP ER WITH SMOKE/FIRE DE TECTOR RD C 3 BL 1 PK 240 460 BL OR RD GR BK OR RD OR RD RD RD 6 GND COM HVDR R DFT1 L3 BK T3 YL NOTE 3 PLF NC NO BK UP RD GR BK 2 C WH C 8 L2 K1 BK BR DF2 C YL SPEED R RVC1 DC BK RD YL L1 O 5 7 BL K1 BK M1 LPS2 XFMR ...

  • Goodman Mfg SS-CPH90-150 - page 33

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 33 w iring d ia gram — CPH1 50***3B/ 4B/ 7B*** ( Cont .) R EBTDR BC R HVDR Y RVC1 SEE UNIT RATING PLATE FOR TYPE AN D SIZE 5 OF OVER CUR RENT PROTECTION 4 BLOW ER CONTACTOR COMPRESSOR CO NTACTOR CONDENSER MOTOR CONDENSER MO T OR CONTACTOR COMPRESSOR DEFROST CONT ...

  • Goodman Mfg SS-CPH90-150 - page 34

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS 34 ww w .goodmanmfg.c om SS-CPH90-150 a CCeSSorieS Item # Description Fits Model Sizes 14CURB90150 Roof Curb 14" T all 7½-12½ tons 25FD90150 25% Manual Fresh Air Damper 7½-12½ tons 25MFD90150 25% Motoriz ed Fresh Air Damper 7½-12½ tons BRD3672 Horizontal Bar ometric Relief Damper (two r ...

  • Goodman Mfg SS-CPH90-150 - page 35

    P roduCt S PeCifiCa tionS P roduCt S PeCifiCationS SS-CPH90-150 ww w .goodmanmfg.c om 35 n o teS ...

  • Goodman Mfg SS-CPH90-150 - page 36

    P roduct S Pecifica tionS P roduct S PecificationS 36 ww w .goodmanmfg.c om SS-CPH90-150 Goodman Manufacturing Company, L.P ., reser ves the right to discontinue, or change at an y time, specications or designs without noticeorwithoutincurringobligations.©2010•GoodmanManufacturingCompany,L.P .•? ...

Manufacturer Goodman Mfg Category Air Conditioner

Documents that we receive from a manufacturer of a Goodman Mfg SS-CPH90-150 can be divided into several groups. They are, among others:
- Goodman Mfg technical drawings
- SS-CPH90-150 manuals
- Goodman Mfg product data sheets
- information booklets
- or energy labels Goodman Mfg SS-CPH90-150
All of them are important, but the most important information from the point of view of use of the device are in the user manual Goodman Mfg SS-CPH90-150.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Goodman Mfg SS-CPH90-150, service manual, brief instructions and user manuals Goodman Mfg SS-CPH90-150. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Goodman Mfg SS-CPH90-150.

A complete manual for the device Goodman Mfg SS-CPH90-150, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Goodman Mfg SS-CPH90-150 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Goodman Mfg SS-CPH90-150.

A complete Goodman Mfg manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Goodman Mfg SS-CPH90-150 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Goodman Mfg SS-CPH90-150, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Goodman Mfg SS-CPH90-150, that we can find in the current document
3. Tips how to use the basic functions of the device Goodman Mfg SS-CPH90-150 - which should help us in our first steps of using Goodman Mfg SS-CPH90-150
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Goodman Mfg SS-CPH90-150
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Goodman Mfg SS-CPH90-150 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Goodman Mfg SS-CPH90-150?

Use the form below

If you did not solve your problem by using a manual Goodman Mfg SS-CPH90-150, ask a question using the form below. If a user had a similar problem with Goodman Mfg SS-CPH90-150 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)