Manual Greenheck Fan LFC

16 pages 1.07 mb
Download

Go to site of 16

Summary
  • Greenheck Fan LFC - page 1

    Only qualified personnel should install this unit. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Impr oper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other potential hazards. Other considerations may be requ ...

  • Greenheck Fan LFC - page 2

    2 Model LFC Low-Profile Fan Coil ® The unit should be stored at least 3½ in. (89 mm) of f the floor on wooden blocks covered with moistur e proof paper or polyethylene sheathing. Aisles between parts and along all walls should be provided to permit air circulation and space for inspection. Inspection and Maintenance during Storage While in stora ...

  • Greenheck Fan LFC - page 3

    3 Model LFC Low-Profile Fan Coil ® T able of Contents Installation U n i t L a y o u t .............................. . 3 Lifting / Hanging Instructions ................ 3 Dimensions / Weights ...................... 4 Filter Sizes / Quantity . . . . . . . . . . . . . . . . . . . . . . 4 C o i l D i m e n s i o n s ......................... 5 - 6 S ...

  • Greenheck Fan LFC - page 4

    4 Model LFC Low-Profile Fan Coil ® Unit Dimensions Unit Size I J K Width Inlet Outlet w/o Filter w/ 2 in. Filter w/ 4 in. Filter Height Width Height Width 15 40 42 44 8.0 11.0 38 9.0 36 4.0 6.75 20 40 42 44 11.0 14.0 38 12.0 36 6.5 6.75 25 40 42 44 13.0 16.0 38 14.0 36 8.0 8.5 30 45 47 49 15.5 18.5 38 16.5 36 9.0 9.0 45 45 47 49 14.25 18.5 50 16.5 ...

  • Greenheck Fan LFC - page 5

    5 Model LFC Low-Profile Fan Coil ® Coil Dimensions NOTE Fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). Hot W ater • 1 and 2 Row Unit Size A B 15 7.63 0.75 20 10.13 0.75 25 12.63 0.875 30 15.13 0.875 45 15.13 0.875 50 17.63 1.125 65 22.63 1.375 85 22.63 1.375 All dimensions are in inches. B Copper Sweat ...

  • Greenheck Fan LFC - page 6

    6 Model LFC Low-Profile Fan Coil ® Unit Size A B 4 row 6 row 8 row CDCDCD 30 12.00 7.00 0.625 0.625 0.625 0.875 0.625 0.875 45 12.00 7.00 0.625 0.625 0.625 0.875 0.625 0.875 50 13.50 7.75 0.625 0.625 0.625 0.875 0.625 1.125 65 17.00 9.50 0.875 0.875 0.875 1.125 0.875 1.125 85 17.00 9.50 0.875 0.875 0.875 1.125 0.875 1.125 All dimensions are in inc ...

  • Greenheck Fan LFC - page 7

    7 Model LFC Low-Profile Fan Coil ® System Start-Up For proper unit function and safety , follow everything in this start-up procedur e in the order pr esented. This is to be done after the electrical connections are complete. PRE-ST ART CHECK LIST 1. Disconnect and lock-out all power switches to fan. 2. Check all fasteners, set screws and locking ...

  • Greenheck Fan LFC - page 8

    8 Model LFC Low-Profile Fan Coil ® Symptom Possible Cause Corrective Action Blower fails to operate Blown fuse or open circuit br eaker Replace fuse or reset cir cuit breaker and check amps Broken fan belt Replace Defective motor or capacitor Replace Motor starter overloaded Reset starter and check amps Motor overamps Airflow too high Check airflo ...

  • Greenheck Fan LFC - page 9

    9 Model LFC Low-Profile Fan Coil ® Hot W ater , Chilled W ater Coils 1. Piping should be in accordance with accepted industry standards. Pipework should be supported independently of the coils. Water pipes are copper with sweat connections. USE WET TOWEL TO AVOID BURNING COIL CONNECTION GROMMETS. When installing coupling, do not apply undue stress ...

  • Greenheck Fan LFC - page 10

    10 Model LFC Low-Profile Fan Coil ® Steam Coils, General - continued 3. Standard steam coils are pitched in the casings when installed for horizontal airflow. The casing must be level after the unit is installed for proper condensate drainage. If condensate is not removed, the coil will suffer from water hammering and will have a shortened life. O ...

  • Greenheck Fan LFC - page 11

    11 Model LFC Low-Profile Fan Coil ® Y early Bearings — Most bearings are permanently lubricated and requir e no further lubrication under normal use. Normal use being considered -20ºF to 120ºF and in a relatively clean envir onment. Some bearings are r elubricatable and will need to be regr eased depending on fan use. Check your bearings for g ...

  • Greenheck Fan LFC - page 12

    12 Model LFC Low-Profile Fan Coil ® Coil Maintenance Start-Up Documentation CAUTION Fin edges are sharp. Coils must be clean to obtain maximum performance. Check once a year under normal operating conditions and, if dirty , brush or vacuum clean. Soiled fins reduce the capacity of the coil, demand more energy fr om the fan, and create an envir on ...

  • Greenheck Fan LFC - page 13

    13 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________ ...

  • Greenheck Fan LFC - page 14

    14 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________ ...

  • Greenheck Fan LFC - page 15

    15 Model LFC Low-Profile Fan Coil ® Maintenance Log Date __________________ Time _____________ AM/PM Notes:___________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________ ...

  • Greenheck Fan LFC - page 16

    16 464496 • LFC, Rev . 1, August 2004 Copyright 2004 © Greenheck Fan Corporation Greenheck warrants this equipment to be fr ee from defects in material and workmanship for a period of one year fr om the shipment date. Any units or parts which prove defective during the warranty period will be r eplaced at our option when returned to our factory ...

Manufacturer Greenheck Fan Category Fan

Documents that we receive from a manufacturer of a Greenheck Fan LFC can be divided into several groups. They are, among others:
- Greenheck Fan technical drawings
- LFC manuals
- Greenheck Fan product data sheets
- information booklets
- or energy labels Greenheck Fan LFC
All of them are important, but the most important information from the point of view of use of the device are in the user manual Greenheck Fan LFC.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Greenheck Fan LFC, service manual, brief instructions and user manuals Greenheck Fan LFC. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Greenheck Fan LFC.

A complete manual for the device Greenheck Fan LFC, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Greenheck Fan LFC by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Greenheck Fan LFC.

A complete Greenheck Fan manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Greenheck Fan LFC - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Greenheck Fan LFC, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Greenheck Fan LFC, that we can find in the current document
3. Tips how to use the basic functions of the device Greenheck Fan LFC - which should help us in our first steps of using Greenheck Fan LFC
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Greenheck Fan LFC
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Greenheck Fan LFC in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Greenheck Fan LFC?

Use the form below

If you did not solve your problem by using a manual Greenheck Fan LFC, ask a question using the form below. If a user had a similar problem with Greenheck Fan LFC it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)