-
Napoleon Fireplaces GD82NT - page 1
1 W415-0536 / C / 09.06.06 W415-0536 / C / 09.06.06 ...
-
Napoleon Fireplaces GD82NT - page 2
2 W415-0536 / C / 09.06.06 WHA T T O DO IF Y OU SMELL GAS Do not touch any electrical switch. If you cannot reach your gas supplier , call the fire department. Do not try to light any appliance. Do not use any phone in your building. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. Instal ...
-
Napoleon Fireplaces GD82NT - page 3
3 W415-0536 / C / 09.06.06 PG2-6 INTRODUCTION W arnings and Safety Precautions W arranty Dimensions General Instructions General Information Care of Glass & Plated Parts 6-10 vENTING V ent lengths Air T erminal Locations 11-16 INST ALLA TION/FRAMING W all & Ceiling ...
-
Napoleon Fireplaces GD82NT - page 4
4 W415-0536 / C / 09.06.06 ALL SPECIFICA TIONS AND DESIGNS ARE SUBjECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. P A TENTS U.S. 5.303.693.801 - CAN. 2.073.411, 2.082.915. © WOLF STEEL L TD. napoleon products are manufactured under the strict Standard of the world r ...
-
Napoleon Fireplaces GD82NT - page 5
5 W415-0536 / C / 09.06.06 Minim ...
-
Napoleon Fireplaces GD82NT - page 6
6 W415-0536 / C / 09.06.06 24" 16" 8" Expansion / contraction nosies during heating up and cooling down cycles are normal and are to be expected. Change in ? ...
-
Napoleon Fireplaces GD82NT - page 7
7 W415-0536 / C / 09.06.06 ver tical rise in feet v T figure 4 when (H T ) < (v T ) (only one 90° elbow) See graph to determine the required vertical rise v T for the required horizontal run H T . ? ...
-
Napoleon Fireplaces GD82NT - page 8
8 W415-0536 / C / 09.06.06 H 2 H 1 v 1 90° See graph to determine the required verti- cal rise V T for the required horizontal run H T . v 1 = v T = 6 ft H 1 = 3 ft H 2 = 5 ft H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03 (tw o 90° e lb ows - 9 0°) = . 03( 18 0° - 90 °) = 2. 7 ft H T = H R + H O = 8 + 2.7 = 10.7 ft H T + v T = 10.7 + 6 =16.7 Formul ...
-
Napoleon Fireplaces GD82NT - page 9
9 W415-0536 / C / 09.06.06 required ver tical rise in feet v T horizont al vent run Plus offset in feet H T when (H T ) < (v T ) figure 9 90° elbow (top exit) or one 90° elbow (rear exit), the f ...
-
Napoleon Fireplaces GD82NT - page 10
10 W415-0536 / C / 09.06.06 figure 12 ...
-
Napoleon Fireplaces GD82NT - page 11
1 1 W415-0536 / C / 09.06.06 This application occurs when venting through a ro of. I nsta lla tion k its for various roof pitches are available from your Napoleon dealer . See Access ories to order the 1. Determine the air terminal location, cut and frame 9½ or 1 1½ inc h openi ngs i ...
-
Napoleon Fireplaces GD82NT - page 12
12 W415-0536 / C / 09.06.06 ...
-
Napoleon Fireplaces GD82NT - page 13
13 W415-0536 / C / 09.06.06 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf Steel vent spacers or equivalent every 3 feet and either side of each elbow to maintain the minimum 1¼” clearance between the outer and inner vent pipes. Use Wolf Steel support ring as- sembly or equivalent non ...
-
Napoleon Fireplaces GD82NT - page 14
14 W415-0536 / C / 09.06.06 flue collar restrictor pla te top of tHe firebox ? ...
-
Napoleon Fireplaces GD82NT - page 15
15 W415-0536 / C / 09.06.06 WARNING F acing and/or finishing material must ne ver o verhang into the fireplace opening. Do not distor t or force the fr ame kit components. W hen using a rough finish materi - al (i.e.; stone), maintain a ¼” - ½” bor der from the framing components. NON-COMBUSTIBLE FINISHING MA TERIAL 59 3 / 8 " 21 3 / ...
-
Napoleon Fireplaces GD82NT - page 16
16 W415-0536 / C / 09.06.06 figure 32 MANTLE CLEARANCES 0 3 4 7 8 9 1 1 13 1 2 5 6 7 10 12 H E I G H T M A N T L E MANTLE WIDTH Combustible mantle clearance can vary according to the man- tle depth. Use the graph to help evaluate the clearance needed. ? ...
-
Napoleon Fireplaces GD82NT - page 17
17 W415-0536 / C / 09.06.06 4. Pla ce log #4 with the charred branch facing inwa rd. Positio n the pin in log #4 into the hole on the right of log #2. 5 . P l a c e l o g # 5 s o the locating hole on the botttom of the log sits on the screw and spacer . 6 . F i n a l l y, a l i g n t h e rectangular peg on log #6 with the notch on the front right p ...
-
Napoleon Fireplaces GD82NT - page 18
18 W415-0536 / C / 09.06.06 BLOWER MOUNTING PLA TE REMOVE 4 SCREWS BL O WER REPLA CEMENT The Napoleon P ARK A VENUE comes equipped with a heat circ ulatin g bl ower . The blo wer is pre- wired and is controll ed by the remote control supplied with the unit. For control details, see operation. Pg. 22. ? ...
-
Napoleon Fireplaces GD82NT - page 19
19 W415-0536 / C / 09.06.06 1. Carefully remove the glass door and all logs. (Refer to the installation manual) 2. Remove the two screws holding the front portion of the . Remove the pilot shield by removing the two screws as illustrated. (Fig. 42) 3. Remove the 3 screws holding the burner down ...
-
Napoleon Fireplaces GD82NT - page 20
20 W415-0536 / C / 09.06.06 1. Attach screw and spacer as illustrated in Fig. 46 to the bottom of both sides of the front housing. 2. Attach the face plate bracket provided to the top edge of the front housing using 2 #8 - 1/2” truss head screws as illustrated in Fig. 47. 3. Lift and hook the faceplate over the spacers. Then push the top of the f ...
-
Napoleon Fireplaces GD82NT - page 21
21 W415-0536 / C / 09.06.06 REMO TE, RECEIvER AND v AL vE ACCESS 1a. Rectangular Front Removal the male portion of the latch ...
-
Napoleon Fireplaces GD82NT - page 22
22 W415-0536 / C / 09.06.06 running and the gas valve turned to the “ON” position. Ensure that the receiver has power and the backup switch is in the auto ...
-
Napoleon Fireplaces GD82NT - page 23
23 W415-0536 / C / 09.06.06 5. F AN SPEED SETTING This function controls the speed of the hot air circulating fan. T o change the fan speed, use the UP and Down button until the cursor (small triangle) is left of the fan icon. Set to one of 4 levels included or turned off (level 4 means full speed) 6. TIMER SETTING The Remote Control has a sleep fu ...
-
Napoleon Fireplaces GD82NT - page 24
24 W415-0536 / C / 09.06.06 ADDRESS SETTING PROCEDURE Use the UP and DOWN key on the transmitter until the cursor (small triangle) is left of the clock icon. From time 0:00 press the LEFT key ten times. The display will show then the trans- mitter address. Press the LEFT key to exit this function. The transmitter address is required to be equal to ...
-
Napoleon Fireplaces GD82NT - page 25
25 W415-0536 / C / 09.06.06 DIP SWIT CH NUMBER (0 = ON / 1 = OFF) figure 64 ...
-
Napoleon Fireplaces GD82NT - page 26
26 W415-0536 / C / 09.06.06 A. T lit by hand while following these instructions exactly . B. B ? ...
-
Napoleon Fireplaces GD82NT - page 27
27 W415-0536 / C / 09.06.06 AIR SHUTTER OPENING lead to carboning. Opening the air shutter will cause a more ? ...
-
Napoleon Fireplaces GD82NT - page 28
28 W415-0536 / C / 09.06.06 This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting ther- mocouple supplied by Wolf Steel Ltd. # P ART NO. DESCRIPTION 1 W135-0267 #1 - REAR LOG 2 W135-0268 #2 - MIDDLE LOG 3 W135-0269 #3 - RIGHT LOG 4 W135-0270 #4 - LEFT LOG 5 W135-0 ...
-
Napoleon Fireplaces GD82NT - page 29
29 W415-0536 / C / 09.06.06 44 43 56 55 53 19 9 22 21 20 18 23 32 62 68 AUX ON 0:00 00 ON/OFF FEATURE SELECT 63 26 24 25 27 36 35 2 13 1 1 15 14 12 66 49 50 51 7 1 3 4 52 67 5 6 ...
-
Napoleon Fireplaces GD82NT - page 30
30 W415-0536 / C / 09.06.06 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- GLASS WHEN HOT ...
-
Napoleon Fireplaces GD82NT - page 31
31 W415-0536 / C / 09.06.06 Remote wall switch is in “OFF” main burner comes on when gas knob i s t u r n e d t o “ O N ” position. W all switch is mounted up- side down - reverse. Faulty valve. - replace. - replace. Rem ote wall swi tch is groun d- ing. ? ...
-
Napoleon Fireplaces GD82NT - page 32
32 W415-0536 / C / 09.06.06 Fireplace Service History This fireplace must be serviced annually depending on usage DA TE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE SPECIAL CONCERNS ...
-
Napoleon Fireplaces GD82NT - page 33
33 W415-0536 / C / 09.06.06 NOTES ...
-
Napoleon Fireplaces GD82NT - page 34
34 W415-0536 / C / 09.06.06 NOTES ...
Do you have a question concerning Napoleon Fireplaces GD82NT?
Use the form below
If you did not solve your problem by using a manual Napoleon Fireplaces GD82NT, ask a question using the form below. If a user had a similar problem with Napoleon Fireplaces GD82NT it is likely that he will want to share the way to solve it.