Manual Cobalt Networks 8321(-C)

48 pages 5.6 mb
Download

Go to site of 48

Summary
  • Cobalt Networks 8321(-C) - page 1

    Cobalt Digi tal Inc. 8310(-C) (10-Slot) 8321(-C) ( 2 0 - S l o t ) openGear TM 2RU Frame and Pow er Supply (PS-8300) User Manual 8310/8321-UM Version: 1.0 ...

  • Cobalt Networks 8321(-C) - page 2

    Page 2 8310/8321 Us e r M a n ua l • • • • (V 1.0) openGear TM 2RU Frame and Power Supply (PS-8300) User Manual • Cobalt Digital Inc. Part Number: 8310/8321-UM • Documen t Version: 1.0 • Printed in the United States. • Last Auth or: CGG • Printing Date: 8/28/09 The information contained in th is Own er’s Manual is subject to cha ...

  • Cobalt Networks 8321(-C) - page 3

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 3 Important Regulatory and Safety Notices Before usin g this produ ct and any associated equipm ent, ref er to the “ Important Safety Instructions ” listed bel ow s o as to avoid pers onal in jury and to preven t product dam age. Products m ay requ ire specific equi pmen t, and /or instal ...

  • Cobalt Networks 8321(-C) - page 4

    Page 4 8310/8321 Us e r M a n ua l • • • • (V 1.0) Important Safety Instructions Read these in structions. Keep these ins tructions. Heed all warn ings. Follow all instructions. Warn ing The safe operation of this product requ ires that a protective earth connection be provided. A grounding conductor in the equipmen t's supply cord pro ...

  • Cobalt Networks 8321(-C) - page 5

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 5 Product Pow e r Cord Requirements Warn ing North American Line Voltages 100 - 120 Volts This product is su pplied w it h certif ied 10A/ 125V SVT ty pe suppl y cords . Conductors are color coded w h ite (neutral), black (lin e) and green or green/y ellow (groun d). Operation of th is equipm ...

  • Cobalt Networks 8321(-C) - page 6

    Page 6 8310/8321 Us e r M a n ua l • • • • (V 1.0) Maintenance/User Serv iceable Parts Routine m aintenance to this Cobalt Digital Inc. product is not required. T his product contains no user serviceable parts. If the fram e does n ot appear to be workin g properly , please contact Techni cal Support u sing the n um bers list ed under th e ...

  • Cobalt Networks 8321(-C) - page 7

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 7 Contents Introduction 9 In This Ch apter ................................................................................................................ .......... 9 A Word of Thanks ....................................................................................................... 9 O ...

  • Cobalt Networks 8321(-C) - page 8

    Page 8 8310/8321 Us e r M a n ua l • • • • (V 1.0) Install ing t he Rear Su pport Bars and Brack ets .......................................................... 37 Service Information 43 In This Ch apter ................................................................................................................ ........ 43 Troubleshootin ...

  • Cobalt Networks 8321(-C) - page 9

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 9 Introduction In This Chapter This chapter contains the follow ing sections: • A Wor d of T hanks • Overview • Features • Documenta tion T er ms A Word of Thanks Congra tulatio ns on cho osing the openG ear TM 2RU Fram e and Power Supply (PS-8300). T he Cobalt Digital Inc. openGear T ...

  • Cobalt Networks 8321(-C) - page 10

    Page 10 8310/8321 Us e r M a n ua l • • • • (V 1.0) For applications w here oth er types of I/O connection s are necess ary (s uch as tw isted- pair audio or fi ber interfaces ), the fram e also supports slot-dependen t rear m odules. Rear m odules can be ordered w ith cards, and are easy and qu ick to inst all. Robust Pow er Supplies The 8 ...

  • Cobalt Networks 8321(-C) - page 11

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 11 • Aluminum constructi o n red uces o veral l weight • Two in dependent looping Referen ce Input s feed all card s lots • SMPTE alarm interface f or simple m onitoring • Ether net p o rt fo r op tio na l networke d co ntro l • Robus t 150 Watt Pow er S upply w ith integ ral coolin ...

  • Cobalt Networks 8321(-C) - page 12

    Page 12 8310/8321 Us e r M a n ua l • • • • (V 1.0) Installation and Setup In This Chapter This chapter contains the follow ing sections: • Static Discharge • Unpacking • Installing the Fram e • Pow er Su pply PS-8300 an d Pow er Cabl e • Fault Reporting • Im proving Perform an ce • Ventilation and Cooling • Cable Co nnectio ...

  • Cobalt Networks 8321(-C) - page 13

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 13 ESD Susceptibility Static discharge can cause serious damag e to sensitive semicond uctor devic es. Avoid handl i ng circ ui t boa rds i n hi gh static env ironm ents su ch as carpeted areas, and w h en w earing synthetic fib er c l othing. Always exer c ise pr op e r gro unding precaution ...

  • Cobalt Networks 8321(-C) - page 14

    Page 14 8310/8321 Us e r M a n ua l • • • • (V 1.0) Installing the Frame The frame fra me mounts in the ra ck fra me b y m eans o f four r ack scr ews fastened thro ugh the fro nt moun ting flan ges. This should normally be sufficient to carry the load, including the w eight of accompany in g cables. How ever, in certain applications such a ...

  • Cobalt Networks 8321(-C) - page 15

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 15 Note In case of a pow er supply f ailure, contact y our openGear TM dealer. The PS-8300 is a pow er factor corrected s upply , capable of w orking w ith all w orld A C stan dards (100-240V). The su pply has an indicator L ED on th e front, and an error detecti on circui t that w ill indica ...

  • Cobalt Networks 8321(-C) - page 16

    Page 16 8310/8321 Us e r M a n ua l • • • • (V 1.0) Notice For reliable perf orman ce, it is recom mended th at the f rame door not b e op ened fo r lo nger tha n 5 minutes when using the Co oli ng Fan Module option on frames loaded w ith more than 40 Watt. Figure 1. Cooling Fan M odule Frame St acking Opt i ons Cable Connections SMPTE Alar ...

  • Cobalt Networks 8321(-C) - page 17

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 17 4. Each AC connector in cludes a Powerlock , wh ich is desig ned to retain th e power cable connector. Clip th e Powerlock over the sh oulder of the in serted AC cable end. 5. Warning Warning Hazardous Voltages Note — In som e count ries, it may be necessary to s upply the correct main s ...

  • Cobalt Networks 8321(-C) - page 18

    Page 18 8310/8321 Us e r M a n ua l • • • • (V 1.0) Rear I/O Module Installation If y ou are installin g an openGear TM card i n a 8310-C -BNC or 8310- BNC f rame, s kip th is sect ion. If y ou received a cu stom rear I/O modu le for y our openGear TM card, y ou will n eed to install the I/O modu le in y our 8310 frame bef ore you can conne ...

  • Cobalt Networks 8321(-C) - page 19

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 19 openBUS Connector This RJ45 conn ector is u sed to exch ange in form ation data f rom cards ins talled in the 8310 fram e to an external m onitoring/control sy stem. On ly cards h aving th e openBUS interface w ill be able to be monitored and controlled this way . T his is reserved for fut ...

  • Cobalt Networks 8321(-C) - page 20

    Page 20 8310/8321 Us e r M a n ua l • • • • (V 1.0) SMPTE 269M Fault Reporting Option In This Chapter This chapter contains the follow ing sections: • Overview • Frame C onnections • Details Overv iew The SMPTE 269M Fault R eporting sy stem , also know n as a SM PTE “ alarm, ” provides an indication if one or more fram e cards enc ...

  • Cobalt Networks 8321(-C) - page 21

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 21 Frame Connections The SMPTE 269M Fault R eportin g conn ection on openGear TM 8310 series fram es is prov ided by the FAULT BNC conn ector, for interf acing w ith a cus tomer- designed alarm system . SMPTE F ault BN C Figure 8. SMP TE 269M Alarm Report i ng Frame Connect ions Details The f ...

  • Cobalt Networks 8321(-C) - page 22

    Page 22 8310/8321 Us e r M a n ua l • • • • (V 1.0) Specifications In This Chapter This chapter contains the Technical Specification s table. Technical Specifications Table 2. Technic al Specif ications Category Parameter Spec ification Input 100 - 240VA C, 47- 63 Hz, 190 Watt Outpu t 1 +12V, ± 10% , 0.5A - 12.5A Outpu t 2 -7.5V, ± 10%, 0 ...

  • Cobalt Networks 8321(-C) - page 23

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 23 Category Parameter Specificat ion Level 1Vp p no mina l Signal Analog video sy nc (black burs t or tri-l evel), or AES/EBU DARS Impedan ce 75 Ω termin ating Retu rn Los s >30dB to 30MHz Max DC on Ref Input ±1V Alarm Indicator ANSI/ SMPTE 269M-1999 contact closure Connector Female BNC ...

  • Cobalt Networks 8321(-C) - page 24

    Page 24 8310/8321 Us e r M a n ua l • • • • (V 1.0) Important Notes: The power dis sipation of each product installed in this f rame is in dicated in the Specifi cations section of the docum entation provided with each module. For long- term reliability and increased product life, it is recom men ded that the total dissipation of all m odul ...

  • Cobalt Networks 8321(-C) - page 25

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 25 Frame Features In This Chapter This chapter contains the follow ing sections: • Cooli ng Feature s o Installing the Cooling Fan Module o Cool i ng Fa n Functions a nd User Contro ls o Installing the Controller Card o Functions of the Controller Card o Controls and LEDs of the Controller ...

  • Cobalt Networks 8321(-C) - page 26

    Page 26 8310/8321 Us e r M a n ua l • • • • (V 1.0) Cooling Features The standard 8310 f rame can be also be ordered as t he 8310-C v ersion , wi th th e Coolin g Fan Modu le installed as orig inal equipm ent from the f actory. How ever, for custom ers w ishin g to increase th e ventilation on their stan dard 8310 fram es, the optional C FM ...

  • Cobalt Networks 8321(-C) - page 27

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 27 1. Open the C FM-8310 packag e and rem ove the com ponents . Verify that all necessa ry compon ents are inclu ded. • Fan PCB 8310A -016 • Fan Filter S985-006 • 8 nu ts 650- 007 • 8 w ash ers 960-025 • MFC- 8310(-N) Fram e Controller Card 2. Turn fram e power off . 3. Open the f r ...

  • Cobalt Networks 8321(-C) - page 28

    Page 28 8310/8321 Us e r M a n ua l • • • • (V 1.0) Next y ou w ill install eith er an MFC- 8310 or an MFC-8310- N controller card. Ref er to the appropriate section for installation instructions for y our specific controller card . Installing the Controller Card Use th e follow ing procedure to in stall th e MFC- 8310 controll er card comp ...

  • Cobalt Networks 8321(-C) - page 29

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 29 seconds af ter th e fan door is closed, th en adjust t o the appropriate l evel bas ed on pow er consumpti on. • Monitors the fram e door and PS-8300(s) to ens ure th at fans in all u nits are operating correctly. • Monitors the fa n door and n otifies the u ser if it is lef t open too ...

  • Cobalt Networks 8321(-C) - page 30

    Page 30 8310/8321 Us e r M a n ua l • • • • (V 1.0) LED displays an d descriptio ns are provided in the followin g table: Table 3. MFC-8310 Cont roller Card LED Desc riptions LED Color Displ ay and Description Alar m (MFC- 8310) Red When lit, an alarm con dition is occurring in the fram e. Status OK (MFC- 8310) Green When lit, the MFC -8310 ...

  • Cobalt Networks 8321(-C) - page 31

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 31 Remote Control Netw orking Features This secti on inclu des ins truction s for in stalli ng th e MFC-8310- N control ler card for th e CFM-8310 modu le. Note: Refer to Co balt ® reference g uide COMPA SS ™ Rem ote Control User Guide ” (PN 9000RCS -RM) f or thoro ugh information and st ...

  • Cobalt Networks 8321(-C) - page 32

    Page 32 8310/8321 Us e r M a n ua l • • • • (V 1.0) This com pletes t he procedure to con figu re the n etw ork set tings for th e MFC-8310- N controll er card. Functions of the Netw ork Contr oller Car d The MFC- 8310-N cont roller card com ponent of th e CFM-8310 perf orm s sev eral fu nction s: • Monitors f rame pow er usage and sets t ...

  • Cobalt Networks 8321(-C) - page 33

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 33 DS 1 DS 2 DS 3 Alarm Mute Button Fan B o ar d Con nect or Ed ge DS 6 DS 7 DS 5 DS 4 Figure 14. MFC-8310-N Card E dge Cont rols DIP Switches on the M FC-8310-N The follow ing DIP Sw itches are located on the MFC -8310-N con troller card. DIP_1 Switch DIP_1 switch disables the au dio alarm s ...

  • Cobalt Networks 8321(-C) - page 34

    Page 34 8310/8321 Us e r M a n ua l • • • • (V 1.0) Reset Button This button is used to restart b oth of the onboard pr o cessors: the fan control processor and the comm unications process or. The comm un ications process or requires approxim ately 30 seconds to resta rt and re-est a blish ne twork communicati o ns. MFC- 8310-N LEDs The fro ...

  • Cobalt Networks 8321(-C) - page 35

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 35 Table 4. MFC-8310-N Cont roller Card LED Des c riptions LED Color Location Di splay and Description Alar m (MFC- 8310-N) Red DS1 When lit, an alarm condition is occurring in the fram e. Status OK (MFC- 8310-N) Green DS2 When lit, the f an control process is op erating correctly. Comm . Act ...

  • Cobalt Networks 8321(-C) - page 36

    Page 36 8310/8321 Us e r M a n ua l • • • • (V 1.0) Enabling SNMP You m ust obtain a licen se key from Cobal t Digi tal Inc. to en able SNMP su pport. Use the follow ing procedure to obtain y our license k ey: 1. Reques t a licens e key from your distri butor or at sales@cobaltdigita l.com , qu oting the 8-ch aracter hardw are-ID provided o ...

  • Cobalt Networks 8321(-C) - page 37

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 37 Rear Support Bars and Brackets Under normal conditions, m ounting the fram e to the front of the rack w ith four rack screws should be suff icient to carry the load, inclu ding the w eight of accom pany ing cables. The optiona l FSB-8310 Rear Support Bars an d Brackets are s pecifically en ...

  • Cobalt Networks 8321(-C) - page 38

    Page 38 8310/8321 Us e r M a n ua l • • • • (V 1.0) 8321 20-Slot Frame Setup In This Chapter This chapt er provides in form ation on setti ng u p and usi ng th e 8321 series f ram e. The 8321 is a 2RU m odular fram e, designed to accom m odate up to 20 openGear cards an d support u p to 10 high-de nsi t y openG e ar fib er c ard s. The foll ...

  • Cobalt Networks 8321(-C) - page 39

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 39 Rear Modules for the 8321 Series Frames If y our 8321 series f rame w as ordered with cards requiring Fu ll Rear Modules or Split R ear Modules, the appropr iate modules are installed at the factory or included w ith the cards. Bl ank Rear M o dules ( R2-BLANK ) are installed w hen the slo ...

  • Cobalt Networks 8321(-C) - page 40

    Page 40 8310/8321 Us e r M a n ua l • • • • (V 1.0) Split Rear Modul e This modu le features two card con nectors and can include u p to 10 BNCs, or a combin ation of BNC, AES, an d fiber optic conn ectors. Each card conn ector is routed to a colu mn of fi ve BNCs. This modu le can only be used in a 8321 series f rame. A Split Rear Module o ...

  • Cobalt Networks 8321(-C) - page 41

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 41 Cooling Features The 8321 series f rames come s tandard w ith the Cooli ng Fan Module in stalled as origin al equipm ent from the factory. How ever, if you n eed to replace the ven tilation in a 8321 series fram e door, the option al CFM- 8321 Coolin g Fan Module is availabl e as a fiel d ...

  • Cobalt Networks 8321(-C) - page 42

    Page 42 8310/8321 Us e r M a n ua l • • • • (V 1.0) Specifications for the 8321 Series Frames This section includes t he Technical Specif ications table for th e 8321 series fram e. Table 4.5 8321 Series Frame Technical Specificatio ns Category Parameter Specification Input 100-240VA C, 47- 63Hz, 190W Outpu t 1 +12V, ± 10% , 0.5A - 12.5A O ...

  • Cobalt Networks 8321(-C) - page 43

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 43 Service Information In This Chapter This chapter contains the follow ing sections: • Troubleshoot ing C heckl ist • Frame Controller Alarm Mute/Bootload B utton • Warranty and Repair Policy Troubleshooti ng Checkl ist Routine main tenance to this openGear TM product is not required. ...

  • Cobalt Networks 8321(-C) - page 44

    Page 44 8310/8321 Us e r M a n ua l • • • • (V 1.0) Use the follow ing procedure to reload the sof tw are: 1. Eject the card. 2. Press and hold the Alarm Mu te/Bootlo ad button, w hile re-inserting the card into the fram e. 3. Release the bu tton. The STAT US OK LED will flash GREEN w hile the card is waiting for a new so ftware load. If a ...

  • Cobalt Networks 8321(-C) - page 45

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 45 Warranty and Repair Policy Cobalt Digi t al Inc. Limi t ed Warranty This product is w arranted t o be free from defects in m aterial and w orkm ansh ip for a period of fiv e (5) years from the date of sh ipmen t to th e origin al purchas er, except th at 4000, 5000, 6000, 8000 series pow e ...

  • Cobalt Networks 8321(-C) - page 46

    Page 46 8310/8321 Us e r M a n ua l • • • • (V 1.0) Ordering Information In This Chapter Your 8310 op en Ge a r TM T wo R ack Un it Fram e and Pow er Supply (PS -8300) is a part of the open Gear TM fam ily of produ cts. We off er a fu ll lin e of openGear TM term inal equipmen t including distribution, conver sion, monit oring, synchronize ...

  • Cobalt Networks 8321(-C) - page 47

    8310/8321 Us e r M a n ua l • • • • (V 1.0) Page 47 Notes: ...

  • Cobalt Networks 8321(-C) - page 48

    Page 48 8310/8321 Us e r M a n ua l • • • • (V 1.0) Contact Us Contact Cobalt Digital Inc. General Business Office and Technical Support 217.344.1243 PHONE Fax 217.344.1245 General Information Info@cobaltdigital.com E-MA IL Sales Information Sales@cobaltdigital.com Cobalt Digi tal Inc. 2406 East Un iversit y A ven ue Urbana, IL 61802 USA PO ...

Manufacturer Cobalt Networks Category Power Supply

Documents that we receive from a manufacturer of a Cobalt Networks 8321(-C) can be divided into several groups. They are, among others:
- Cobalt Networks technical drawings
- 8321(-C) manuals
- Cobalt Networks product data sheets
- information booklets
- or energy labels Cobalt Networks 8321(-C)
All of them are important, but the most important information from the point of view of use of the device are in the user manual Cobalt Networks 8321(-C).

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Cobalt Networks 8321(-C), service manual, brief instructions and user manuals Cobalt Networks 8321(-C). Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Cobalt Networks 8321(-C).

A complete manual for the device Cobalt Networks 8321(-C), how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Cobalt Networks 8321(-C) by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Cobalt Networks 8321(-C).

A complete Cobalt Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Cobalt Networks 8321(-C) - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Cobalt Networks 8321(-C), FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Cobalt Networks 8321(-C), that we can find in the current document
3. Tips how to use the basic functions of the device Cobalt Networks 8321(-C) - which should help us in our first steps of using Cobalt Networks 8321(-C)
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Cobalt Networks 8321(-C)
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Cobalt Networks 8321(-C) in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Cobalt Networks 8321(-C)?

Use the form below

If you did not solve your problem by using a manual Cobalt Networks 8321(-C), ask a question using the form below. If a user had a similar problem with Cobalt Networks 8321(-C) it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)