  • Foundry Networks M2404C - page 1

    Foundry NetIron M2404C and M2404F Metro Access Switches Inst allation Guide ™ 4980 Great America Parkway Santa Clara, CA 95054 Tel 408.207.1700 www.foundrynetworks. com January 2007 ...

  • Foundry Networks M2404C - page 2

    Copyright © 2007 Foundr y Net works, Inc. All rights reserved. No part of this work may be reproduced in any form or by any means – graphic, electronic or mechan ica l, including photocopyin g, recording, taping or storage in an informatio n retri eval system – without prior written permission of the copyright owner. The trademarks, logos and ...

  • Foundry Networks M2404C - page 3

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. ii Safety Considerations This equipment is for use in a restricted access area by qualified personnel only. To avoid electric shock, do not perform any servicing other than those contained in the u npacking instructions. This equipment contains Electrost ...

  • Foundry Networks M2404C - page 4

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. iii WARNING GROUNDING Before connecting the product to th e power line, make sure that the protective ground terminal of the devi ce is connected to the safety ground conductor of the mains power cord. The main power supply plug should only be inserted i ...

  • Foundry Networks M2404C - page 5

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. iv T able of Content s ABOUT THIS DOCUMENT ......................................................................................... 1 W HO S HOULD U SE T HIS G UIDE ..................................................................................... 1 ...

  • Foundry Networks M2404C - page 6

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. v S OFTWARE I MAGE N AMING C ONVENTIONS ................................................................. 26 D OWNLOADING A S OFTWARE I MAGE TO THE S WITC H U SING TFTP ............................ 26 Preparing to Download an Image Using TFTP ........... ...

  • Foundry Networks M2404C - page 7

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 1 About This Document Who Should Use This Guide The procedures in this manual are for trained a nd qualified service personnel who are proficient with network switching and routing concepts. Inst allation, replacement and maintenance of the equipment des ...

  • Foundry Networks M2404C - page 8

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 2 Conventions Used in this Document This document uses the following formatting st yles and conventions: • CLI syntax and coded examples are represente d by mono-space characters and enclosed in rectangular frames. Under this category: o Text issued by ...

  • Foundry Networks M2404C - page 9

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 3 Overview Introduction High powered networks require a combination of sp eed and robust services support to be able to provide the intensive and fluctuating demands of their end users. To answer these requirements, the network needs to provide data tran ...

  • Foundry Networks M2404C - page 10

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 4 Hardware Description Front Panel Enhanced GigE Ports 100baseX Ports GigE Ports Switch Management Ports (Ou tband Port on top and Console Port on bottom) PSU LEDs Reset Button Figure 3: NetI ron M240 4F Platfor m Front Panel Enhanced GigE Ports 10/100ba ...

  • Foundry Networks M2404C - page 11

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 5 3. Gently insert the SFP tranceiver into the port until the module clicks into place. The m odule is keyed to prevent incorrect insertion. See Figure 5 . Important Note When inserting an SFP tranceiver into ports mark ed 27 or 28, verify that the SFP i ...

  • Foundry Networks M2404C - page 12

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 6 Component Description GigE Dual-Mode Ports Two dual-mode1000baseX interface (SFP) or 10/100/1000BaseT (RJ45) marked 25 and 26. Enhanced GigE Ports Two 1000baseX interface ( SFP) marked 27 and 28. Please note that the SFP transceivers are inserted into ...

  • Foundry Networks M2404C - page 13

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 7 Port Status LEDs A status LED is associated with each port. Port Status Indication Link Green Activity Blinking green Fault/disabled Amber NetIron M2404C Port Status LEDs Figure 6: Loc ation of NetIr on M2404C Port Status LE Ds The port status LEDs (1 ...

  • Foundry Networks M2404C - page 14

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 8 NetIron M2404F Dual-Mod e Port Status LEDs Figure 8: Loc ation of Net Iron M240 4F Dual-M ode Port St atus LEDs Dual-mode port status LEDs are associated with dual-mode RJ45/SFP GiGE ports 25 and 26. RJ-45 Indicators RJ45 Dual-Mode Port Status Indicati ...

  • Foundry Networks M2404C - page 15

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 9 Rear Panel – with AC Power-Supply Units Hot-swappable PSU #2 Fan apertures Hot-swappable PSU #1 On-off sw it c h AC-Power inlet Grounding s tuds On-off sw it c h AC-Po wer inlet Figure 9: Rear Pane l with AC PSUs Panel Main Components Two AC Power su ...

  • Foundry Networks M2404C - page 16

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 10 Rear Panel – with DC Power-supply Units Hot-swappable PSU #2 Fan apertures Hot-swappable PSU #1 Terminal block PWR and Invert. Con. LEDs Grounding studs Terminal block PWR and Invert. Con. LEDs Figure 10: Re ar Panel with DC PSUs Panel Main Componen ...

  • Foundry Networks M2404C - page 17

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 11 DC power-supply terminals: -48V/3A GND +BAT.RET LEDs: INVERT CON. PWR Figure 12: DC Power Supply Unit The DC power supply panel has the following components: Input terminals: -48V/3A Negative DC input terminal GND Ground terminal internally connected ...

  • Foundry Networks M2404C - page 18

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 12 Figure 13 Blank Filler for Empty Power-Supply Slo t ...

  • Foundry Networks M2404C - page 19

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 13 Inst allation and Setup This section provides installation and setup instru ctions. The platform can be installed in a standard 19-inch rack or as a standalone unit in a desktop configuration. Packing List The shipping package includes the following i ...

  • Foundry Networks M2404C - page 20

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 14 WARNING Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over. Rack Mounting Specifications Width Basic body: 440 mm (17.4”) Overall, including brackets: 483 mm (19”) Height 44 ...

  • Foundry Networks M2404C - page 21

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 15 Ethernet Cables When connecting an RJ-45/RJ-48 port to an end st ation, workstation or server, use a standard RJ-45/RJ-48 pin-out cable. Console Interface A simple menu-driven interface provides for syst em initialization and diagnostics. The Console ...

  • Foundry Networks M2404C - page 22

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 16 For each DC power block a set of a minimum 2x18AWG cables shall be used with suitable end terminal legs matching the conductor’s gauge. U se a RED lead to for the positive conductor and a BLACK lead for the negative conductor. It is recommended that ...

  • Foundry Networks M2404C - page 23

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 17 2. Remove the bolts and spring-washers from the grounding p osts on the switch’s rear panel, and clean the metal surface underneath with a dry cloth if necessary. 3. Apply some anti-oxidant onto the metal surface. 4. Mount the lug on the two groundi ...

  • Foundry Networks M2404C - page 24

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 18 Initial Configuration Using the Console Initial Configuration The Configuration command-language interface (CLI) is accessed by using a VT-100 (or compatible terminal) to the console port of the sw itch. The terminal port param eters are fixed at: 960 ...

  • Foundry Networks M2404C - page 25

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 19 quit Disconnect and logout show Show running system information terminal Terminal configuration setup who Display who is on vty To continue initial configuration pr ocedure perform the following steps: 1. Enter privileged (Enable) mode. Type the comma ...

  • Foundry Networks M2404C - page 26

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 20 application Application downloading image java Java downloading image running-config Copy running config... startup-config Startup configuration data To write the backup configuration file, type: device-name # copy startup-config < IP address > ...

  • Foundry Networks M2404C - page 27

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 21 Temperature Management Commands Viewing the Status: device-name # show temperature CPU Temperature = 28C / 82F device-name # show temperature high-limit CPU Temperature high limit = 20C / 68F Configuring Temperature Management Parameters: device-name ...

  • Foundry Networks M2404C - page 28

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 22 Monitoring the Power Supplies Status Viewing the status during system boot: BUILT-IN SELF TEST ------------------ CPU Core Test : Passed CPU Interface Test : Passed Data Buffer Test : Passed Power Supply Test : Passed On-board Power Test : Passed Fan ...

  • Foundry Networks M2404C - page 29

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 23 Built-In Self T est (BIST) The BIST performs a set of basic hardware and configuration validity tests. Tests in the BIST are sorted into several groups – for example, the tests of the Power Suppl y units belong to a Power Supply Test group. Startup ...

  • Foundry Networks M2404C - page 30

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 24 2. Re-power the unit, if required. 3. Use the show self-test command in Privileged (Enable) mode. If you prefer to display all BIST results, use the show self-test full command instead. To invoke a BIST by Request at any time while the switch is runni ...

  • Foundry Networks M2404C - page 31

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 25 //////////////////////////////////////////////////////////////////// //................................................................// // FOUNDRY NETWORKS // // // // Switch model : FOUNDRY NETWORKS NETIRON M2404F 256M // // SW version : 2.0.00 cre ...

  • Foundry Networks M2404C - page 32

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 26 Sof tware Download The executable software image contained on the platform can be upgraded via the network whenever new versions become available, reflec ting changes in the MIBs or enhancements to the software. The software is stored in erasable Flas ...

  • Foundry Networks M2404C - page 33

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 27 1. Copy the device software image file to the appropriate TFTP directory on the workstation. 2. Log into the switch through the console port or through a Telnet session. If you l og in using Telnet, your Telnet session will disconnect when you reset t ...

  • Foundry Networks M2404C - page 34

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 28 6. Configure the switch to boot with the ne wly downloaded image. This is done by selecting boot application and boot device. device-name # config boot-param device-name (boot param)# application < local application filename > device-name (boot ...

  • Foundry Networks M2404C - page 35

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 29 1. Copy the software image file to the appropriate TFTP directory on the workstation. 2. Log into the switch through the console p ort or through a Telnet session. 3. Download the software image from the TFTP server using the copy java command in Priv ...

  • Foundry Networks M2404C - page 36

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 30 Hot-swapping a Power Supply The switch has two redundant power supplies, a nd can be operated when only one power supply is connected and powered on, or with both po wer supplies active. When both power supplies are active, you can remove or replace o ...

  • Foundry Networks M2404C - page 37

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 31 S pecifications Physical Specifications Dimensions Width 440 mm (17.4”) Height 44 mm (1.73”) Depth 419 mm (16.5”) Chassis without PSU 3.7 kg (8.2 lbs) Each AC Power Supply 0.6 kg (1.3 lbs) Weight Each DC Power Supply 0.6 kg (1.3 lbs) Operating C ...

  • Foundry Networks M2404C - page 38

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 32 Environment: The equipment is designed for use in indoor applications only. Management Features Inband: Integrated SNMP agent Java applet , Telnet and SSH MIBs Supported: MIB II, Bridge MIB, Private MIB ,RMON MIB (Groups 1,2,3,9) Traps/Alarms: SNMP tr ...

  • Foundry Networks M2404C - page 39

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 33 FCC 47 CFR: 2003 part 15 subpart B, class A This equipment has been tested and found to co mply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harm ...

  • Foundry Networks M2404C - page 40

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 34 Appendix A: Cautions and W arnings Caution Statements A caution calls your attention to a possible hazard that can damage equipm ent. "Vorsicht” weist auf die Gefahr einer möglichen Beschädigung des Gerätes in. Une mise en garde attire votre ...

  • Foundry Networks M2404C - page 41

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 35 energía retirado no se reemplaza, insert e el relleno PSU en blan co provisto en el slot y asegúrelo al panel con los dos tornillos. CAUTION: Changes or modificatio ns made to th is device that are not expressly approved by the party responsible for ...

  • Foundry Networks M2404C - page 42

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 36 Warning Statements A warning calls your attention to a possible hazard that can cause injury or death. The following are the warnings used in this manual. "Achtung" weist auf eine mögliche Gefährdung hin, die zu Verletzungen oder Tod führ ...

  • Foundry Networks M2404C - page 43

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 37 should only be performed by qualified personn el, authorized by Foundry Networks. ACHTUNG: Hochspannung Trennen Sie das Gerät vo m Netz, bevor Sie die Abdeckung abne hmen. Alle Einstellungs- und Wartungsarbeiten am geöffnete n Gerät dürfen nur von ...

  • Foundry Networks M2404C - page 44

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 38 La prise d’alimentation p ri ncipale doit être inséré e uniquement dans une prise ayant un raccordement à la terre. Cette protection n e doit pas être remise en cause par l’ utilisation d’u ne rallonge (câble d’alimentation) ne possédan ...

  • Foundry Networks M2404C - page 45

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 39 ADVERTENCIA: CABLEADO PARA ENCH UFE DE C O RRIENTE NACIONAL Con cada uni dad se sumi nistra un cable de alimentación principal según el Código eléctrico nacio nal (National Electri cal Code o NEC) con zócalo IEC moldeado. El enchufe d e alimentac ...

  • Foundry Networks M2404C - page 46

    Foundry NetIron M2404C/M2404F Metro Access Switches January 2007 © 2007 Foundry Networks, Inc. 40 AVERTISSEMENT : Vérifiez que l e chassis ou l’armoi re incluant l’unité est bien fixé afin qu’il ne devienne pas instable ou qu’il ne risque pas de tomber. ADVERTENCIA: Verifique que el montante o el gabinete que alberga e l dispositivo est ...

Manufacturer Foundry Networks Category Switch

Documents that we receive from a manufacturer of a Foundry Networks M2404C can be divided into several groups. They are, among others:
- Foundry Networks technical drawings
- M2404C manuals
- Foundry Networks product data sheets
- information booklets
- or energy labels Foundry Networks M2404C
All of them are important, but the most important information from the point of view of use of the device are in the user manual Foundry Networks M2404C.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Foundry Networks M2404C, service manual, brief instructions and user manuals Foundry Networks M2404C. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Foundry Networks M2404C.

A complete manual for the device Foundry Networks M2404C, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Foundry Networks M2404C by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Foundry Networks M2404C.

A complete Foundry Networks manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Foundry Networks M2404C - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Foundry Networks M2404C, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Foundry Networks M2404C, that we can find in the current document
3. Tips how to use the basic functions of the device Foundry Networks M2404C - which should help us in our first steps of using Foundry Networks M2404C
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Foundry Networks M2404C
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Foundry Networks M2404C in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Foundry Networks M2404C?

Use the form below

If you did not solve your problem by using a manual Foundry Networks M2404C, ask a question using the form below. If a user had a similar problem with Foundry Networks M2404C it is likely that he will want to share the way to solve it.

Copy the text from the picture