Manual LifeSource UA-702

20 pages 0.31 mb
Download

Go to site of 20

Summary
  • LifeSource UA-702 - page 1

    TM C ongratulations. Y ou have pur chased a LifeSour ce state-of-the-art blood pr essur e monitor , one of the most technologically advanced yet easy to use pr oducts available in the marketplace today . This LifeSour ce monitor is designed to make your daily r egimen useful, and convenient. Physicians agr ee that daily self-monitoring of blood pr ...

  • LifeSource UA-702 - page 2

    WHA T DISPLA Y SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . . 3 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . 4 HOW 702 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 BEFORE YOU ST ART . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SELECTING THE CORRECT CUFF . . . . . . . . . . . . . ...

  • LifeSource UA-702 - page 3

    Display Symbol Recommended Action Remain still and r efrain fr om talking; measur ement in pr ogr ess. Pr ess exhaust button to r elease air . Incr ease pr essurization by 30 mmHg to 40 mmHg and r epeat measur ement. Replace all batteries with new ones. Exhaust air fr om cuff, r eap- ply cuff pr operly , power up again and r epeat measur e- ment in ...

  • LifeSource UA-702 - page 4

    PRESSURE AND PULSE DISPLA Y AIR SOCKET CUFF CUFF BA TTERY COMP ARTMENT SYSTOLIC DIAST OLIC (PULSE) POWER DIGIT AL BLOOD PRESSURE MONITOR MEASURING PRESS EXHAUST RE-MEASURE BA TTER Y LOW RE-MEASURE UA-702 POWER BUTTON MONITOR COMPONENTS AIR CONNECTOR 4 ? LifeSource Health Line (T oll-Free): 1-888-726-9966 ? EXHAUST V AL VE AND ADJUSTMENT SCREW INFLA ...

  • LifeSource UA-702 - page 5

    Y ou must install 4 type AA (1.5 volt) batteries and attach the cuff to the monitor befor e using it. T o install batteries (or r eplace them if the “Low Battery” symbol appears on display), pr oceed as follows: 1. Remove battery compartment cover by gently pushing down on arr ow and sliding cover forward. 2. Put in top r ow of batteries first. ...

  • LifeSource UA-702 - page 6

    Using the corr ect cuff size is impor tant for an accurate r eading. A cuff that is too lar ge will pr oduce a r eading that is lower than the corr ect blood pr essur e; a cuf f that is too small yields a measur ement that is higher . W ith your arm hanging at the side of your body , measur e the cir cumfer ence of your upper arm at the midpoint be ...

  • LifeSource UA-702 - page 7

    T AKING YOUR BLOOD PRESSURE T ips for Blood Pr essur e Monitoring: ☞ Relax for about 5 to 10 minutes befor e measur ement. ☞ Remove constricting clothing and place cuff on bar e arm. ☞ Unless your physician r ecommends otherwise, use left arm to measur e pr essur e. Now you ar e r eady . Follow these simple steps: 1. Sit comfortably with your ...

  • LifeSource UA-702 - page 8

    ☞ IMPORT ANT : Measure pressure at the same time each day . 4. Pr ess the POWER button. 5. W atch for all display symbols to appear briefly , followed by a zer o, indicating that monitor is r eady for measur ement. 6. W atch the display and squeeze the bulb quickly until cuff pr essur e r eaches about 30 mmHg to 40 mmHg above expected systolic pr ...

  • LifeSource UA-702 - page 9

    7. Sit quietly during measur ement. Pr essur e values ar e displayed at left, then right, along with ❤ symbol blinks and beeps with pulse beat. NOTE: If you wish to stop inflation at any time, press the exhaust valve to release air . 8. W ait for the long beep, indicating that the measurement is complete. Y our systolic pr essur e will appear on ...

  • LifeSource UA-702 - page 10

    10. Remove cuff and make a note of your blood pr essur e and pulse rate on the chart (see page 16), indicating date and time of measur ement. W e advise that you r ecor d the date and time after each measur e- ment because an accurate blood pr essur e history r elies not on single or sporadic r eadings but on a pattern over time. NOTE: If you wish ...

  • LifeSource UA-702 - page 11

    CHECK/ADJUST EXHAUST VELOCITY Exhaust velocity is the rate at which the air pr essur e in the cuf f deflates during the course of measur ement. It is pr eset at the factory and generally does not need any further adjustment. NOTE: The exhaust rate of your monitor was preset and tested at the factory to ensure proper measurement. The rate set is dep ...

  • LifeSource UA-702 - page 12

    4. W atch the display screen. As pr essure automatically decr eases, diastolic numbers should decline in incr ements of 2 to 5 mmHg. If the exhaust velocity range is not within 2 to 5 mmHg, make the following adjustment with the unit turned off: 1. The adjustment scr ew is located on the exhaust valve attached to the inflator bulb. It is cover ed b ...

  • LifeSource UA-702 - page 13

    What Is Blood Pressure? Blood pr essur e is the for ce exerted by blood against the walls of the arteries. Systolic pr essure occurs when the hear t contracts; diastolic pr essur e occurs when the hear t expands. Blood pr essur e is measur ed in millimeters of mer cury (mmHg). What Affects Blood Pressure? Blood pr essur e is af fected by many facto ...

  • LifeSource UA-702 - page 14

    Assessing High Blood Pressure The following standar ds for assessing high blood pr essur e (without r egar d to age) have been established by the National Institutes of Health JNCVI. Category Systolic (mmHg) Diastolic (mmHg) Optimal <120 <80 Normal <130 <85 High Normal 130 - 139 85 – 89 Hypertension Stage 1 140 – 159 90 – 99 Stage ...

  • LifeSource UA-702 - page 15

    Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pr essur e r eadings taken in a doctor’ s office or hospital setting might be elevated as a r esult of appr ehension and anxiety . This r esponse is commonly called “white coat hypertension.” One way to determine whether this is the case for you is to t ...

  • LifeSource UA-702 - page 16

    EXAMPLE D A TE AM SYS/DIA PULSE PM SYS/DIA PULSE Name: Age: W eight: BLOOD PRESSURE RECORD 1/14 9:30 132/98 P 69 6:30 128/87 P 63 TM 16 ❤ LifeSource Health Line (T oll-Free): 1-888-726-9966 ...

  • LifeSource UA-702 - page 17

    Please r ead this important information befor e using your monitor . ☞ Please r emember that only a medical practitioner is qualified to interpr et your blood pr essur e measur ements. Use of this device should not r eplace r egular medical examinations. ☞ Have your physician r eview your pr ocedur e for using this device. He or she will want t ...

  • LifeSource UA-702 - page 18

    Model . . . . . . . . . . . . . . . . . . .UA-702 T ype . . . . . . . . . . . . . . . . . . . . .Oscillometric Display . . . . . . . . . . . . . . . . . .Digital, 10-mm character height Pr essur e/pulse displayed alternately Measurement range . . . . . . . . . Pr essur e: 20 mmHg to 280 mmHg Pulse: 40 pulses to 200 pulses/minute Accuracy . . . . . ...

  • LifeSource UA-702 - page 19

    Our pr oducts ar e designed and manufactur ed using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and tr eatment options. The pr oduct line includes: Aner oid Blood Pressure Kits Blood Pressure Cuffs Digital Blood Pressure Monitors Digital Thermometers Stethoscopes This LifeSource product is cover ...

  • LifeSource UA-702 - page 20

    CONT ACT INFORMA TION A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www .LifeSourceOnline.com LifeSour ce is a trademark of A&D Medical. ©2003 A&D Medical. All rights reserved. Specifications subject to change without notice. I-MAN:702 Printed in China 12/03 IMPORT ANT! If Y ou Need Assistance with the Se ...

Manufacturer LifeSource Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a LifeSource UA-702 can be divided into several groups. They are, among others:
- LifeSource technical drawings
- UA-702 manuals
- LifeSource product data sheets
- information booklets
- or energy labels LifeSource UA-702
All of them are important, but the most important information from the point of view of use of the device are in the user manual LifeSource UA-702.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals LifeSource UA-702, service manual, brief instructions and user manuals LifeSource UA-702. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product LifeSource UA-702.

Similar manuals

A complete manual for the device LifeSource UA-702, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use LifeSource UA-702 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of LifeSource UA-702.

A complete LifeSource manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual LifeSource UA-702 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the LifeSource UA-702, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the LifeSource UA-702, that we can find in the current document
3. Tips how to use the basic functions of the device LifeSource UA-702 - which should help us in our first steps of using LifeSource UA-702
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with LifeSource UA-702
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of LifeSource UA-702 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning LifeSource UA-702?

Use the form below

If you did not solve your problem by using a manual LifeSource UA-702, ask a question using the form below. If a user had a similar problem with LifeSource UA-702 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)