    #23960 P1ge 1 W ARNING Improper installation, adjustment, alteration, service or maintenance can cause serious injury or pr oper ty damage. Refer to this manual. For assistance or additional inf ormation, consult a qualified installer or ser vice agency . CAUTION The recommended temperature for normal resid ential use is 120°F . The dial on the aq ...

  • Rheem Indirect Water Heater - page 2

    P age 2 T ABLE OF CONTENTS Section I: Specifications ....................................................... 3 Section II: General Informations ................................................. 5 Section III: Pre-Installation ...................................................... 7 Section IV : Installation ......................................... ...

  • Rheem Indirect Water Heater - page 3

    P age 3 G Cold Inlet, 3/4" NPT Ho t Ou tlet / Anode Rod , 3/4" NPT Anode Rod Aquast at T&P Relief Va lv e Fr om Bo iler Supply , 1" NPT To Bo iler Return, 1" NPT Dr ain Va lv e F D C E B A SECTION I: SPECIFICA TIONS Foam insulation standard on indirect water heater models. Pressures, all: T est pressure, 300 PSI Working pres ...

  • Rheem Indirect Water Heater - page 4

    Page 4 SECTION I: SPECIFICA TIONS (cont.) STID30 30 1.38 110 85 25 55,000 1.3 2.0 STID40 38 2.30 153 120 33 77,000 1.1 3.0 STID50 45 2.30 160 120 40 77,000 1.0 3.0 STID80 75 2.76 200 130 70 83,000 0.9 5.0 STID120 110 2.76 232 130 102 83,000 1.2 5.0 Model Actual T ank Volume (gal) Coil Volume (gal) First Hour Rating (gal)* Continuous Draw Rating (GP ...

  • Rheem Indirect Water Heater - page 5

    SECTION II: GENERAL INFORMA TION LOCA TION The indirect water heater should be located in a central location to the piping system, as close as practical to the boiler and in an area not subject to freezing temperatures. Leave sufficient space for servicing and maintaining the indirect water heater . NO TICE: Long heating supply runs can lengthen re ...

  • Rheem Indirect Water Heater - page 6

    Page 6 SECTION II: GENERAL INFORMA TION (cont.) ANODE RODS The anode rod is used as a sacrificial element within the volume of the storage tank. The purpose of the magnesium anode r od is to protect the inside of the tank against corrosion. Anode r ods should be inspected twice in the first year and at least yearly once a time interval for inspecti ...

  • Rheem Indirect Water Heater - page 7

    SECTION III: PRE-INST ALLA TION BOILER AND CIRCULA T OR SIZING The ratings published in this manual for your Rheem indirect water heater can be obtained through proper selection of boiler output and circulator capacity . As noted, the ratings in T able 2 are based on a 77°F rise with 58°F potable water inlet temperature at a circulator pump flow ...

  • Rheem Indirect Water Heater - page 8

    Page 8 UP 15-42F /FR Closed S y stem s , 60 Hz UP 26-64F Closed S y stem s , 60 Hz SECTION III: PRE-INST ALLA TION (cont.) Figure 4: GRUNDFOS UP 15-42F performance curve Figure 5: GRUNDFOS UP 26-64F performance curve NO TICE: Zone valves on the heat source supply to the indirect water heater are not recommended and will drastically reduce perf orma ...

  • Rheem Indirect Water Heater - page 9

    BOILER SYSTEM SUPP L Y CIRCULA TO R PUMP BOILER SYSTEM RETURN BOILER COLD 1" INLET WA TER HE A T ER INDIRECT HO T OUT DOMESTIC 1 1/2" BOILER FROM TO BOILER CHECK V A L V E BOILER SUPP L Y SYSTEM DOMESTIC 3/4" HO T OUT INDIRECT WA TER HE A T ER BOILER TO BOILER FROM COLD INLET 3/4" V A L V E CHECK PUMP CIRCULA TO R RETURN SYSTEM ...

  • Rheem Indirect Water Heater - page 10

    Page 10 See Figure 8 for piping your Rheem indirect water heater to a low-mass boiler (diagram recommended b y boiler manufacturer). SECTION IV : INST ALLA TION (cont.) CHECK VA LV ES ZONE CIRCULA TORS ISOLA TION VA LV ES ADDITIONAL ZONES INDIRECT CIRCUL AT OR INDIRECT WA TER HEA TER TO HE AT ING ZONE AIR SE PA RA TOR AIR VENT EXP ANSION TA NK COLD ...

  • Rheem Indirect Water Heater - page 11

    ELECTRICAL CONNECTIONS Figures 9 and 10 are general wiring diagrams. For a maintaining temperature boiler , Figure 9 should c losely match your system. For cold start boilers your wiring may resemble Figure 10, but will vary depending on the boiler type and controls or rela ys used. It is not possible to list all wiring v ariations here. When conne ...

  • Rheem Indirect Water Heater - page 12

    Page 12 SECTION V : MAINTENANCE W A TER PIPING On an annual basis, all piping should be checked for leakage at joints, shut-off v alves, and unions. T&P RELIEF V AL VE On an annual basis, the temperature and pressure relief valve should be chec ked for proper operation. First, attach a drain line to the valve to direct the water discharge to an ...

  • Rheem Indirect Water Heater - page 13

    &LUFXODWRUGRHVQRW RSHUDWH &KHFNDTXDVWDWVHWWLQJ 352%/( 0& $86( 62/87,21 %RLOHUGRHVQRW RSHUDWH 5HIHUWRERLOHULQVWDOODWLRQ LQVWUXFWLRQV &KHFNPDLQVHUYLFHVZLWFK &KHFNIXVHGGLVFRQQHFW 3HDNXVHRIKRWZDWHU LVJUHDWHUWKDQWDQN VWRUDJHFDSDFLW 'HWHUPLQHSHDN ...

  • Rheem Indirect Water Heater - page 14

    SECTION VII: P ARTS LIST No. Description A pplicab le Models 1 Anode All models. 2 Anode Outlet STID 30, STID 40, STID 50 3 T&P Relief V alve All models. 4 Drain V alve All models. 5 Aquastat All models. Page 14 14 2 1 3 4 5 ...

  • Rheem Indirect Water Heater - page 15

    Page 15 LIMITED W ARRANTY For Rheem/Ruud™ Indirect Water Heaters. GENERAL This Limited Warranty is only available to the original owner of this water heater. It is not transferable. The Rheem Water Heater Operation of Rheem Manufacturing Company (Rheem) warrants this water heater , and its component parts, to be free from defects in materials and ...

  • Rheem Indirect Water Heater - page 16

    Page 16 EXCLUSIVE W ARRANTY – LIMIT A TION OF LIABILITY This Limited Warranty is the only W arranty given by the manufacturer , the Rheem W ater Heater Operation of Rheem Manufacturing Company , for this unit. No one is authorized to make any other warranties on behalf of the manufacturer . ANY IMPLIED W ARRANTIES, INCLUDING MERCHANT ABILITY , OR ...

Manufacturer Rheem Category Water Heater

Documents that we receive from a manufacturer of a Rheem Indirect Water Heater can be divided into several groups. They are, among others:
- Rheem technical drawings
- Indirect Water Heater manuals
- Rheem product data sheets
- information booklets
- or energy labels Rheem Indirect Water Heater
All of them are important, but the most important information from the point of view of use of the device are in the user manual Rheem Indirect Water Heater.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Rheem Indirect Water Heater, service manual, brief instructions and user manuals Rheem Indirect Water Heater. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Rheem Indirect Water Heater.

Similar manuals

A complete manual for the device Rheem Indirect Water Heater, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Rheem Indirect Water Heater by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Rheem Indirect Water Heater.

A complete Rheem manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Rheem Indirect Water Heater - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Rheem Indirect Water Heater, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Rheem Indirect Water Heater, that we can find in the current document
3. Tips how to use the basic functions of the device Rheem Indirect Water Heater - which should help us in our first steps of using Rheem Indirect Water Heater
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Rheem Indirect Water Heater
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Rheem Indirect Water Heater in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Rheem Indirect Water Heater?

Use the form below

If you did not solve your problem by using a manual Rheem Indirect Water Heater, ask a question using the form below. If a user had a similar problem with Rheem Indirect Water Heater it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)