  • Omron INTELLISENSE BP755 - page 1

    A utomatic Blood P ressur e Monitor with C omF it ™ C uff Model BP755 INSTRUCTION MANU AL BP755 ® ESP AÑOL ENGLISH BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 1 ...

  • Omron INTELLISENSE BP755 - page 2

    C ONTENTS 2 Befor e Using the Monitor Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Risk of Electrical Shock . . ...

  • Omron INTELLISENSE BP755 - page 3

    Thank you for purchasing Omron ® BP755 IntelliSense ® Automatic Blood Pressure Monitor with the ComFit ™ Cuf f. INTRODUCTION 3 F ill in for future refer ence . DA TE PURCHASED: __________________ SERIAL NUMBER: ____________________ Staple your pur chase receipt her e Y our new digital blood pressure monitor uses the oscillometric method of bloo ...

  • Omron INTELLISENSE BP755 - page 4

    SAFET Y INFORMA TION 4 T o assur e the corr ect use of the pr oduct, basic safety measur es should always be followed including the warnings and cautions listed in this instruction manual. W ARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury . SAFETY SYMBOLS USED IN THIS INSTRUCTION MAN ...

  • Omron INTELLISENSE BP755 - page 5

    SAFET Y INFORMA TION 5 OPERA TING THE DEVICE (continued) This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. Read the Special Conditions section (page 24) of the instruction manual if your systolic pressure is known to b ...

  • Omron INTELLISENSE BP755 - page 6

    SAFET Y INFORMA TION 6 CARE AND MAINTENANCE Do not subject the monitor to strong shocks, such as dropping the unit on the floor . Do not submer ge the device or any of the components in water . Store the device and the components in a clean, safe location. Changes or modification not approved by the manufacturer will void the user warranty . Do not ...

  • Omron INTELLISENSE BP755 - page 7

    7 BEFORE T AKING A MEASUREMENT T o ensure a reliable reading follow these recommendations: 1. A void eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes before taking a measurement. Rest for at least 15 minutes before taking the measurement. 2. Stress raises blood pressure. A void taking measurements during stressful times. 3. ...

  • Omron INTELLISENSE BP755 - page 8

    8 KNOW Y OUR UNIT Air Jack ® B P 7 5 5 Main Unit: Batter y C ompar tment Star t/Stop Button Memor y Buttons Date/Time Setting Button ( ) Display AC A dapter Jack C omponents: Arm C uff Air T ube Air Plug (Connects to Air Jack) A C Adapter Storage Case Thumb Grip Operating Instructions Instruction Manual Automatic Blood Pressure Monitor with ComFit ...

  • Omron INTELLISENSE BP755 - page 9

    9 UNIT DISPLA Y Diastolic Blood P ressure Systolic Blood P ressure Memor y Symbol Pulse Displa y Date/Time Display Batter y L ow Indicator A verage V alue Symbol Hear tbeat Symbol/ Hyper tension Indicator Deflation Symbol Mov ement Error Symbol Irregular Heartbeat Symbol BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 9 ...

  • Omron INTELLISENSE BP755 - page 10

    10 DISPLA Y SYMBOLS IRREGULAR HEAR TBEA T SYMBOL ( ) When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that is more than 25% slower or 25% faster from the average rhythm ...

  • Omron INTELLISENSE BP755 - page 11

    11 DISPLA Y SYMBOLS HEAR TBEA T SYMBOL/HYPER TENSION INDICA T OR () T AKING A MEASUREMENT The Heartbeat Symbol ( ) flashes on the display during the measurement. The Heartbeat Symbol ( ) flashes at every heartbeat. When the measurement is complete, the Heartbeat Symbol ( ) flashes on the display with your blood pressure and pulse rate if the readin ...

  • Omron INTELLISENSE BP755 - page 12

    The American Heart Association recommends the following guideline for upper limit of normal for home blood pressure readings: AHA Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on age and morbidity . The AHA recommends a lower h ...

  • Omron INTELLISENSE BP755 - page 13

    IMPORT ANT SAFET Y INSTRUCTIONS SA VE THESE INSTRUCTIONS 13 USING THE A C ADAPTER NOTES: • Use only the authorized Omron AC Adapter that came with this monitor . • W e recommend you install the batteries even if the AC Adapter is used. If no batteries are installed, you may need to reset the date and time if the AC Adapter is disconnected. The ...

  • Omron INTELLISENSE BP755 - page 14

    T o connec t the A C Adapter ① Insert the AC Adapter Plug into the AC Adapter Jack on the back side of the monitor as illustrated. ② Plug the AC Adapter into a 120V AC outlet (60 cycles). T o disconnec t the A C Adapter ① Hold and pull the housing to remove the AC Adapter from the electrical outlet. Do not remove by pulling the cord. ② Remo ...

  • Omron INTELLISENSE BP755 - page 15

    NOTE: Use 4 new “AA” size batteries - long life alkaline batteries are recommended. 1. Press the ▼ indicator on the battery cover and slide the cover of f in the direction of the arrow . 2. Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated. NOTE: 4 ? ...

  • Omron INTELLISENSE BP755 - page 16

    16 BA T TER Y INST ALLA TION B A TTER Y REPLA CEMENT Low Battery Indicator When the Low Battery Indicator appears on the display screen, turn the monitor of f and remove all the batteries. Replace with four new batteries at the same time. Long-life alkaline batteries are recommended. W ARNING If battery fluid should get in your eyes, immediately ri ...

  • Omron INTELLISENSE BP755 - page 17

    Set the monitor to the current date and time before taking a measurement for the first time. If the current date and time are not set correctly , the measurement values stored in the memory and the average values may not be correct. 1. T O ST AR T THE SETTING Press the Date/T ime Setting button ( ) to adjust the date and time. The year flashes on t ...

  • Omron INTELLISENSE BP755 - page 18

    18 3. SETTING THE MONTH Press the Memory Up button to advance by increments of one month. Press the Date/T ime Setting button ( ) to set the current month. The day flashes on the display . 4. SETTING THE DA Y Press the Memory Up button to advance by increments of one day . Press the Date/T ime Setting button ( ) to set the current day . The hour fl ...

  • Omron INTELLISENSE BP755 - page 19

    19 6. SETTING THE MINUTE Press the Memory Up button to advance by increments of one minute. Press the Date/T ime Setting button ( ) to set the current minute. The year flashes on the display . 7. TO TURN THE MONITOR OFF Press the ST AR T/STOP button. NOTE: The monitor will automatically turn of f after the minute has been set after battery replacem ...

  • Omron INTELLISENSE BP755 - page 20

    CA UTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CA UTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions. APPL YING THE CUFF ON THE LEFT AR ...

  • Omron INTELLISENSE BP755 - page 21

    21 3. Hold the thumb grip on the cuf f securely with your hand. 4. T urn the palm of your hand upward. 5. Apply the cuff to your left upper arm so the blue stripe is on the inside of your arm and aligned with your middle finger . The air tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" above your elbow ...

  • Omron INTELLISENSE BP755 - page 22

    6. W rap the cuff firmly in place around your arm using the cloth fastening. APPL YING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 5. Apply the cuf f to your right upper arm so the thumb grip is centered on the inside of your inner arm. The bottom of the cuff should be approximately 1/2&apos ...

  • Omron INTELLISENSE BP755 - page 23

    23 The monitor automatically determines your ideal inflation level. In rare circumstances when a higher inflation may be necessary , the monitor automatically re-inflates the cuf f up to 30mmHg higher than the initial inflation and restarts the measurement. 1. Sit on a chair with your feet flat on the floor . Place your arm on a table so the cuf f ...

  • Omron INTELLISENSE BP755 - page 24

    2. Press the ST AR T/STOP button. All display symbols appear on the screen. The cuf f starts to inflate automatically . As the cuf f inflates, the monitor automatically determines your ideal inflation level. Remain still and do not move your arm until the entire measurement process is completed. NOTE: T o stop the inflation or measurement, push the ...

  • Omron INTELLISENSE BP755 - page 25

    25 T AKING A MEASUREMENT 4. When the measurement is complete, the arm cuf f completely deflates. Y our blood pressure and pulse rate are displayed. 5. Press the ST AR T/STOP button to turn the monitor of f. NOTE: The monitor will automatically turn of f after five minutes. SPECIAL CONDITIONS CA UTION Inflating to a higher pressure than necessary ma ...

  • Omron INTELLISENSE BP755 - page 26

    26 Every time you complete a measurement the monitor stores the blood pressure and pulse rate in the memory . The monitor automatically stores up to 90 sets of measurement values (blood pressure and pulse rate). When 90 sets of measurement values are stored, the oldest record is deleted to save the most recent values. ADV ANCED A VERAGING FUNCTION ...

  • Omron INTELLISENSE BP755 - page 27

    27 2. Press the Memory Down button to display the most recent set of measurement values on the screen. Pr ess the Memory Up button to display the oldest set of measurement values. NOTES: • The date and time are alternately displayed with the measurement values. • Press the button repeatedly to display the next values. • Press and hold the but ...

  • Omron INTELLISENSE BP755 - page 28

    T O DELETE ALL V AL UES ST ORED IN THE MEMORY Y ou cannot partially delete values stored in the memory . All values will be deleted. 1. While holding the Memory Down button , press the ST AR T/STOP button down for more than 2 seconds until the display appears as it does in the following illustration. 2. Press the ST AR T/STOP button to turn the mon ...

  • Omron INTELLISENSE BP755 - page 29

    29 T o keep your digital blood pr essur e monitor in the best condition and pr otect the unit fr om damage, follow the dir ections listed below: Keep the monitor in the storage case when not in use. Make sure the AC Adapter is placed under the main unit so that is does not damage the display . Do not for cefully bend the arm cuff or air tube. Do no ...

  • Omron INTELLISENSE BP755 - page 30

    C ARE AND MAINTENANCE 30 Use the unit in a manner consistent with the instructions pr ovided in this manual. CA UTION Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit. CA UTION Changes or modification not approved by the manufacturer will void the user warranty . Do not ...

  • Omron INTELLISENSE BP755 - page 31

    31 SYMBOL CA USE C ORRECTION Monitor could not detect pulse wave. T ake another measurement and remain still until the measurement is complete. Cuf f under -inflated. Cuf f not applied correctly . Remove the arm cuf f. Read “T aking a Measurement”. W ait 2-3 minutes. T ake another measurement. Cuf f over -inflated. Batteries are worn. Replace t ...

  • Omron INTELLISENSE BP755 - page 32

    32 ERROR INDIC A T ORS AND TROUBLESHOO TING TIPS PROBLEM CA USES AND SOL UTIONS No power . No display appears on the unit. Replace all four batteries with new ones. Check the battery installation for proper placement of the battery polarities. Measurement values appear too high or too low . Blood pressure varies constantly . Many factors including ...

  • Omron INTELLISENSE BP755 - page 33

    33 FC C ST A TEMENT Note: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. The produc ...

  • Omron INTELLISENSE BP755 - page 34

    W ARR ANT Y LIMITED W ARRANTIES Y our BP755 IntelliSense® Automatic Blood Pressure Monitor , excluding the arm cuf f, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor . The arm cuf f is warranted to be free f ...

  • Omron INTELLISENSE BP755 - page 35

    35 SPECIFIC A TIONS Model: BP755 (HEM-7000-Z4CS) Display : LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accur ac y/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valve Rapid Air Release: Automatic exhaust valv ...

  • Omron INTELLISENSE BP755 - page 36

    Manufactured by OMRON HEAL THCARE Made in China Distributed by: OMRON HEAL THCARE, INC. 1200 Lakeside Drive Bannockburn, Illinois 60015 www .omronhealthcare.com Copyright © 2009 Omron Healthcare, Inc. BP755IM_E_SP_q6_R2.qxd 5/26/09 4:14 PM Page 36 ...

Manufacturer Omron Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Omron INTELLISENSE BP755 can be divided into several groups. They are, among others:
- Omron technical drawings
- INTELLISENSE BP755 manuals
- Omron product data sheets
- information booklets
- or energy labels Omron INTELLISENSE BP755
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omron INTELLISENSE BP755.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omron INTELLISENSE BP755, service manual, brief instructions and user manuals Omron INTELLISENSE BP755. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omron INTELLISENSE BP755.

A complete manual for the device Omron INTELLISENSE BP755, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omron INTELLISENSE BP755 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omron INTELLISENSE BP755.

A complete Omron manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omron INTELLISENSE BP755 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omron INTELLISENSE BP755, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omron INTELLISENSE BP755, that we can find in the current document
3. Tips how to use the basic functions of the device Omron INTELLISENSE BP755 - which should help us in our first steps of using Omron INTELLISENSE BP755
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omron INTELLISENSE BP755
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omron INTELLISENSE BP755 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omron INTELLISENSE BP755?

Use the form below

If you did not solve your problem by using a manual Omron INTELLISENSE BP755, ask a question using the form below. If a user had a similar problem with Omron INTELLISENSE BP755 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)