Manual DeLonghi WIR1

19 pages 0.78 mb
Download

Go to site of 19

Summary
  • DeLonghi WIR1 - page 1

    THERMOST A TICALL Y CONTROLLED W ALL MOUNTED UNVENTED GAS HEA TER WIR1-WIR2 (Equipped with Pilot Light Safety System) W ARNING: If the infor mation in this manual is not followed exactly , a fire or explosion may result caus- ing property damage, personal injur y , or loss of life. - Do not store or use gasoline or other flammable vapors and liquid ...

  • DeLonghi WIR1 - page 2

    SAFETY INFORMA TION W ARNING: Carbon monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be work- ing properly . Get fresh air at once! Have heater ser viced. Some people are more affect- ed by carbon monoxide than others. These include preg ...

  • DeLonghi WIR1 - page 3

    1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Place propane/LP sup- ply tank(s) outdoors. 3. This heater shall not be installed in a bed- room or bathroom. 4. If you smell gas - Shut off ...

  • DeLonghi WIR1 - page 4

    PRODUCT FEA TURES Safety device This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air . Piezo ignition system This heater has a piezo ignitor . This system requires no matches, batterie ...

  • DeLonghi WIR1 - page 5

    Confined and Unconfined Space The National Fuel gas Code , ANSI Z223.1/NFP A 54 defines a confined space as a space whose volume is less than 50 cubic feet per 1,000 Btu per hour (4,8 m 3 per kw) of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per ...

  • DeLonghi WIR1 - page 6

    If the actual Btu/Hr used is less than the max- imum Btu/Hr the space can support, the space is an unconfined space. Y ou will need no addi- tional fresh air ventilation. VENTILA TION AIR V entilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pr ...

  • DeLonghi WIR1 - page 7

    INST ALLA TION CHECK GAS TYPE Use only the correct type of gas (natural or propane/LP). If your gas supply is not the correct gas type, do not install heater . Call dealer where you bought heater for proper type heater . INST ALLA TION ITEMS Before installing heater , make sure you have the items listed below . • for propane/LP gas, external regu ...

  • DeLonghi WIR1 - page 8

    INST ALLA TION • Sign in the wall to make the hole “A”. • Drill the wall by using a 1/4” drill. • Insert the two plastic expansion anchors supplied in the installation kit, in the holes. • Insert two of the four screws supplied in the holes letting them stick out from the wall for at least 5 mm (see fig. aside) • Hook the appliance ...

  • DeLonghi WIR1 - page 9

    Installation must include equipment shutoff valve, union, and plugged 1/8” NPT tap. Locate NPT tap within reach for test gauge hook up. NTP tap must be upstream from heater (see fig 7) IMPORT ANT : install an equipment shutof f valve in accessible location. The equipment shutoff valve is for tur ning on or shutting off the gas to the appliance. A ...

  • DeLonghi WIR1 - page 10

    T est pressures equal or less than 1/2 PSIG (3,5 Kpa) 1. Close equipment shutoff valve (see figure 8). 2. Pressurize supply piping system by either opening propane/LP supply tank valve located on or near gas meter for natural gas, or using compressed air . 3. Check all joints from gas meter for natural gas (see figure B) or propane/LP supply tank f ...

  • DeLonghi WIR1 - page 11

    11 OPERA TING HEA TER A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. Before lighting smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU SMELL GAS. • Do ...

  • DeLonghi WIR1 - page 12

    The thermostatic control used on this model turn on and off the bur ner . The thermostat used on this heater senses the room temperature. At times the room may exceed the set tempera- ture. If so, the burner will shut of f. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any 2 comf ...

  • DeLonghi WIR1 - page 13

    BURNER FLAME P A TTERN Figure 15 shows a correct bur ner flame pat- tern. Figure 16 shows a incorrect burner flame pattern. If burner flame pattern is incorrect, as shown in figure 16 • turn heater off (see to turn off gas to appli- ance, page 12) • see troubleshooting, pages 16 through 18 13 correct burner fig. 16 fig. 15 incorrect burner WIR ...

  • DeLonghi WIR1 - page 14

    CLEANING AND MAINTENANCE ODS/PILOT AND BURNER •U se a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CLEANING BURNER PILOT AIR INLET The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet ho ...

  • DeLonghi WIR1 - page 15

    15 SPECIFICA TION This heater is equipped with an oxygen deple- tion safety system and safety shut-off system. APPLIANCE DIMENSIONS Width: 15.75 inches Height: 29.14 inches Depth: 9.65 inches P ACKAGING DIMENSIONS Width: 18.7 inches Height: 31.3 inches Depth: 11.8 inches REPLACEMENT P ARTS Note: use only original replacement parts. This will protec ...

  • DeLonghi WIR1 - page 16

    16 TROUBLESHOOTING W ARNING: if you smell gas • Shut off gas supply • Do not try to light any appliance • Do not touch any electrical switch; do not use any phone in your building • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instrc- tions • If you cannot reach your gas supplier, call the fire ...

  • DeLonghi WIR1 - page 17

    17 TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation W ARNING: only a qualified ser vice person should ser v- ice and repair heater CAUTION: never use wire,needle, or similar object to clean ODS/pilot. This can damage ODS/pilot unit OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed in, there is no ...

  • DeLonghi WIR1 - page 18

    18 OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light after ODS/pilot is lit 1. Burner orifice is clogged 2. Inlet gas pressure is too low 1. Clean burner orifice (see clean- ing and maintenance, pag 14) or replace the burner 2. Contact local natural gas com- pany Dalayed ignition of burn- er 1. Manifold pressure is too low 2. Burner orif ...

  • DeLonghi WIR1 - page 19

    19 Limited W arranty What Does This W arraty Cover? We warrant each appliance to be free from defects in material and workmanship. Our obligation under this warranty is limited to replacement or repair , free of charge at our factor y or authorized ser vice centers, of any defective part or par ts there of other than parts damaged in transit, which ...

Manufacturer DeLonghi Category Electric Heater

Documents that we receive from a manufacturer of a DeLonghi WIR1 can be divided into several groups. They are, among others:
- DeLonghi technical drawings
- WIR1 manuals
- DeLonghi product data sheets
- information booklets
- or energy labels DeLonghi WIR1
All of them are important, but the most important information from the point of view of use of the device are in the user manual DeLonghi WIR1.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals DeLonghi WIR1, service manual, brief instructions and user manuals DeLonghi WIR1. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product DeLonghi WIR1.

Similar manuals

A complete manual for the device DeLonghi WIR1, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use DeLonghi WIR1 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of DeLonghi WIR1.

A complete DeLonghi manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual DeLonghi WIR1 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the DeLonghi WIR1, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the DeLonghi WIR1, that we can find in the current document
3. Tips how to use the basic functions of the device DeLonghi WIR1 - which should help us in our first steps of using DeLonghi WIR1
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with DeLonghi WIR1
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of DeLonghi WIR1 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning DeLonghi WIR1?

Use the form below

If you did not solve your problem by using a manual DeLonghi WIR1, ask a question using the form below. If a user had a similar problem with DeLonghi WIR1 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)