Manual Monessen Hearth 3000 SERIES

44 pages 1.04 mb
Download

Go to site of 44

Summary
  • Monessen Hearth 3000 SERIES - page 1

    3000 SERIES DIRECT VENT GAS FIRE PLACE INSTALLATION AND OPE RATING INSTRUCTIONS DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPE R IES. CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITIO N. YOUNG CHILDERN S ...

  • Monessen Hearth 3000 SERIES - page 2

    ...

  • Monessen Hearth 3000 SERIES - page 3

    T T A A B B L L E E O O F F C C O O N N T T E E N N T T S S 1 IMPORTANT SAFETY INF ORMATION: ................................................................................................................ 2 PRODUCT SPECIFICATIO NS: ..................................................................................................................... ...

  • Monessen Hearth 3000 SERIES - page 4

    I I M M P P O O R R T T A A N N T T S S A A F F E E T T Y Y I I N N F F O O R R M M A A T T I I O O N N 2 IMPORTANT SAFETY INF ORMATION: INSTALLER: Please leave these instructions with the owner. OWNER: Please read and retains these instructions for future referenc e. IMPORTANT: Read these instructions carefully before installing or trying to opera ...

  • Monessen Hearth 3000 SERIES - page 5

    P P R R O O D D U U C C T T S S P P E E C C I I F F I I C C A A T T I I O O N N S S / / L L I I S S T T I I N N G G & & C C O O D D E E A A P P P P R R O O V V A A L L 3 PRODUCT SPECIFICATIO NS: Gas Pressure (Inches W.C.) Models Number Gas Type Control Type Max Btu Max Min Manifold 320DV4136NV Natural Gas Milli - volt 26000 10.5 4.0 3.5 320 ...

  • Monessen Hearth 3000 SERIES - page 6

    P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 4 PRE - INSTALLATION INFORMA TION: Before You Start: Read this homeowner manual thoroughly and follow all instructions carefully. Inspect all contents for shipping damage and immediately inform your dealer if any damage is found. Do not insta ...

  • Monessen Hearth 3000 SERIES - page 7

    P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 5 Figure 1 : Fi replace Dimensions 2 Figure 2 : Fireplace Locations and Minimum Clearances Requirements ...

  • Monessen Hearth 3000 SERIES - page 8

    P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 6 2” Min 2” Min 31” Min Figure 3 : Wall & Ceiling Minimum Clearances Wall and Ceiling Clea rance Requirements: Ensure that minimum clearance shown in Figures 3 is maintained. Left and right clearances are determined when facing the ...

  • Monessen Hearth 3000 SERIES - page 9

    P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 7 Mantel Clearances: A hood/canopy comes with every appliance. If a combustible mantel is installed, it must meet the clearance requireme nts detailed in Figure 4. Combustible wall or drywall to top front edge of unit Figure 4 : Mantel Cleara ...

  • Monessen Hearth 3000 SERIES - page 10

    P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 8 Figure 5 : Combustible Clearances for Vent Pipe Framing Dimensions: Figure 6 : Minimum Framing Dimensions Firebox framing can be built before or after the appliance is set in place. Framing should be positioned to accommodate wall covering ...

  • Monessen Hearth 3000 SERIES - page 11

    P P R R E E - - I I N N S S T T A A L L L L A A T T I I O O N N I I N N F F O O R R M M A A T T I I O O N N 9 Finishing Material: NOTE Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final finishing to avoid costly reconstru ction. WARNING Never obstruct or modify the air inlet or outlet grills (louvers) ...

  • Monessen Hearth 3000 SERIES - page 12

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 10 VENT INSTALLATION: Positioning The Fireplace: NOTE The fireplace must be installed giving full consideration to the clearance and height requirements identified in this manual. 1. Bend out the six (6) nailing flanges located on the sides and top of the fireplace 2. Slide the firebox ...

  • Monessen Hearth 3000 SERIES - page 13

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 11 Horizontal Venting with One (1) Elbow: Figure 9 : Horizontal Venting with One (1) Elbow Vertical Venting with Two (2) Elbows: Figure 10 : Vertical Venting with Two (2) Elbows V, Vertical H, Horizontal Elbow (5 inches) 30 inches Max Elbow (5 inches) 30 inches Corner Max 1 foot Min 5 ...

  • Monessen Hearth 3000 SERIES - page 14

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 12 Horizontal Venting with Three (3) Elbows: Figure 11 : Horizontal Venting with Three (3) Elbows INSTALLING VENT COMP ONENTS Before You Start: Plan your installation. Set unit in place and survey how best to vent the unit. Select the appropriate pipe for the installation. Read this ma ...

  • Monessen Hearth 3000 SERIES - page 15

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 13 NOTE Two 45 ° ° elbows (P/N 945) may be used in place of one 90 ° ° elbow (P/N 990). WARNING Any horizontal run must have a 1/4” rise for every one (1) foot of run towards the vent termination. Never allow the ven t to run downward. This could cause high temperatures and may p ...

  • Monessen Hearth 3000 SERIES - page 16

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 14 For Ceiling • For ceiling firestops, position a plumb bob over the center of the vertical pipe; to spot a hole through which the pipe will penetrate. • Drill a hole through this centerpoint and check the floor for obstructi ons (i.e. wiring or plumbing). • Reposition the firep ...

  • Monessen Hearth 3000 SERIES - page 17

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 15 Vent Termination: For Vertical Termination Figure 15 : Minimum Vent Height for Various Roof Pitches WARNING Major building codes specify a minimum vent height above the rooftop depending on the pitch of the roof. Refer to the above figure for minimum heights, provi ded the terminati ...

  • Monessen Hearth 3000 SERIES - page 18

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 16 For Horizontal Termination Figure 16 : Horizontal Vent Termination Location # A=12 inches Clearance above the grade, a veranda, porch, deck, or balcony # B=12 inches Clearance t o window or door that may be opened. C=12 inches Clearance to permanently closed window. D*=18 inches Ver ...

  • Monessen Hearth 3000 SERIES - page 19

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 17 WARNING Always maintain minimum clearances around vent systems. The minimum clearances to combustibles for horizontal vent pipe are 3 inches at the top and 1 inch at the sides and bottom of the vent system. For wall firestops, a 1 - inch minimum clearance all around the pipe must be ...

  • Monessen Hearth 3000 SERIES - page 20

    V V E E N N T T I I N N S S T T A A L L L L A A T T I I O O N N 18 Figure 18 Horizontal Termination Cap on a Vinyl Siding W all To locate and install horizontal termination cap (P/N HTC) • A wall firestop MUST BE installed if the vent passes through a wall or ceiling. Cut a 10 - inch X 10 - inch hole through the interior or exterior wall. The cen ...

  • Monessen Hearth 3000 SERIES - page 21

    G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 19 GAS LINE AND ELECTRI CAL Gas Line Installation: NOTE Plumbing co nnections should only be performed by a qualified, licensed plumber. Main gas supply must be off when plumbing gas line to fireplace or performing service ...

  • Monessen Hearth 3000 SERIES - page 22

    G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 20 Figure 19 : Gas Pressure Check at Gas Valve Electrical Wiring: CAUTION Electrical connections should only be performed by a qualified, licensed electrician. Main power must be off when connecting to main electrical powe ...

  • Monessen Hearth 3000 SERIES - page 23

    G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 21 Figure 20 : Wiring Diagram for Standing Pilot - Millivolt System Figure 21 : Schematic Diagram for Mi llivolt System ...

  • Monessen Hearth 3000 SERIES - page 24

    G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 22 Optional Fan/Blower Systems The junction box for the fan/blower systems has been factory installed. This system requires that 110 - 120 VAC to be wired to the factory installed junction box before the fireplace is perma ...

  • Monessen Hearth 3000 SERIES - page 25

    G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 23 Optional DC Remote Systems These in structions supersede the section entitled “Hearth Mount” in the Millivolt hand held remote instructions supplied with the remote. 1. Cut cable to length (approximately 12”) for ...

  • Monessen Hearth 3000 SERIES - page 26

    G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 24 Electronic Pilot Ignition Wiring: WARNING Do not connect 110 - 120 VAC to the Remote Wall Switch. The appliance will malfunction or destroyed. Figure 24 : Wiring Diagram for Electronic Ignition Figure 25 : Schematic Dia ...

  • Monessen Hearth 3000 SERIES - page 27

    G G A A S S L L I I N N E E A A N N D D E E L L E E C C T T R R I I C C A A L L I I N N S S T T A A L L L L A A T T I I O O N N 25 Remote Wall Switch Position the wall switch. Refer to Figure 24 : Wiring Diagram for Electronic Ignition . Do not extend beyond the 15 feet of wire. Optional Fan/Blower Systems The junction box for the fan/blower system ...

  • Monessen Hearth 3000 SERIES - page 28

    F F I I N N A A L L I I N N S S T T A A L L L L A A T T I I O O N N 26 FINAL INSTALLATION Wall Finishing: Definitions: Combustible M aterials - Materials made of or surfaced with wood, compressed paper, plant fibers, or other materials that are capable of being ignited and burned. Such materials are considered combustible even though flameproof, fi ...

  • Monessen Hearth 3000 SERIES - page 29

    F F I I N N A A L L I I N N S S T T A A L L L L A A T T I I O O N N 27 Glass Removal: WARNING Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. To remove the glass 1. Remove the top bottom louver. 2. Open the lower access door. Using your righ ...

  • Monessen Hearth 3000 SERIES - page 30

    F F I I N N A A L L I I N N S S T T A A L L L L A A T T I I O O N N 28 Rock Wool Placement: Figure 28 : Rock Wool Plac ement Rock wool needs to be placed on the burner covering the holes at the front of the burner in order to give the “glowing ember” appearance. Refer to the figure above for the placement of rock wool. The rock wool should be p ...

  • Monessen Hearth 3000 SERIES - page 31

    F F I I N N A A L L I I N N S S T T A A L L L L A A T T I I O O N N 29 Log Placement: This fireplace is supplied with a set of four (4) ceramic fiber logs. Do not handle the se logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any t ...

  • Monessen Hearth 3000 SERIES - page 32

    O O P P E E R R A A T T I I N N G G I I N N S S T T R R U U C C T T I I O O N N S S 30 OPERATING INSTRUCTIO NS Before Lighting the Fireplace: • Read the IMPORTANT SAFETY INFORMATION section at the beginning of this homeowner manual. • Before lighting, verify the fireplace for possible gas leaks. • Before lighting, ver ify for possible obstruc ...

  • Monessen Hearth 3000 SERIES - page 33

    O O P P E E R R A A T T I I N N G G I I N N S S T T R R U U C C T T I I O O N N S S 31 Pilot LIGHTING INSTRUCTIONS MILLIVOLT IGN 8. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot. 9. Continuing pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the g ...

  • Monessen Hearth 3000 SERIES - page 34

    O O P P E E R R A A T T I I N N G G I I N N S S T T R R U U C C T T I I O O N N S S 32 FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these Instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. 5. Wait five (5) minutes to clear out any gas. Than smell for gas, including ne ...

  • Monessen Hearth 3000 SERIES - page 35

    M M A A I I N N T T E E N N A A N N C C E E 33 MAINTENANCE WARNING Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check - ups at the beginning of each heating season. The appliance area be kept clear and free from combustible mater ials, gasoline and other flammable vapors and liquids. T ...

  • Monessen Hearth 3000 SERIES - page 36

    M M A A I I N N T T E E N N A A N N C C E E 34 Vent System: The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is int erfering with the airflow. Inspect entire venting system to ensure proper f ...

  • Monessen Hearth 3000 SERIES - page 37

    P P A A R R T T S S L L I I S S T T / / I I L L L L U U S S T T R R A A T T I I O O N N 35 1 3 4 2 PARTS LIST / ILLUSTR ATION Vent Components: Vent Components: Item Simpson Duravent or Monessen P/N Description Qty/Box 1 985 Horizontal Square High Wind Termination Cap 1 2 980 Vertical Termination 1 3 908 6" Pipe Length 6 3 907 9" Pipe Leng ...

  • Monessen Hearth 3000 SERIES - page 38

    P P A A R R T T S S L L I I S S T T / / I I L L L L U U S S T T R R A A T T I I O O N N 36 Item Description Qty 320DV4136 320DV4742 Standard Features 1 Junction Box Assembly 1 26D2128K 26D2128K 2 Black Louver 6 26D0697K 26D 0699K 3 Hood/Canopy 1 37D0288K 37D0537K 4 Temper Glass Frame Assembly 1 37D0279K 37D0615K Factory Installed Options 5 Standard ...

  • Monessen Hearth 3000 SERIES - page 39

    P P A A R R T T S S L L I I S S T T / / I I L L L L U U S S T T R R A A T T I I O O N N 37 Standing Pilot – Millivolt Control Item Description Qty 4136NV 4136NV 4742NV 4742PV 1 Gas Valve Assembly 1 37D0117K 37D0118K 37D0117K 37D0118K 2 Pilot Assembly 1 37D0018K 37D0019K 37D 0018K 37D0019K 3 Burner Tube 1 37D0586K 37D0586K 37D0586K 37D0586K 4 Flex ...

  • Monessen Hearth 3000 SERIES - page 40

    T T R R O O U U B B L L E E S S H H O O O O T T I I N N G G 38 TROUBLESHOOTING Standing Pilot Ignition: SYMPTOM POSSIBLE CAUSE ACTION 1. Spark ignitor will not light pilot after repeated triggering of piezo. A. Wire disconnected. Open door and check to make sure wire is connected to ignitor. B. Defective ignitor. Check for spark at electrode and pi ...

  • Monessen Hearth 3000 SERIES - page 41

    T T R R O O U U B B L L E E S S H H O O O O T T I I N N G G 39 5. The pilot and main burner extinguish while in operation A. Inner vent pipe leaking exhaust gases back into system Check for flue product leak. Repla ce defective pipe section. B. Horizontal vent improperly pitched Check horizontal - venting piping is running upward 1/4” per foot. C ...

  • Monessen Hearth 3000 SERIES - page 42

    T T R R O O U U B B L L E E S S H H O O O O T T I I N N G G 40 Electronic Pilot Ignition: SYMPTOM POSSIBLE CAUSE ACTION 1. The main burner does not light. A. Unit junction box not electrically grounded or properly connected Ensure that 110 VAC is connecte d. B. No gas or low gas pressure. Check remote/manual shut off valve from fireplace. Low press ...

  • Monessen Hearth 3000 SERIES - page 43

    ...

  • Monessen Hearth 3000 SERIES - page 44

    P/N 37D0634, Rev 4 Sept 2000 LIMITED LIFETIME WAR RANTY POLICY Lifetime Warranty The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. Five Year Warranty The following components are warranted five (5) years to the original ...

Manufacturer Monessen Hearth Category Fire Pit

Documents that we receive from a manufacturer of a Monessen Hearth 3000 SERIES can be divided into several groups. They are, among others:
- Monessen Hearth technical drawings
- 3000 SERIES manuals
- Monessen Hearth product data sheets
- information booklets
- or energy labels Monessen Hearth 3000 SERIES
All of them are important, but the most important information from the point of view of use of the device are in the user manual Monessen Hearth 3000 SERIES.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Monessen Hearth 3000 SERIES, service manual, brief instructions and user manuals Monessen Hearth 3000 SERIES. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Monessen Hearth 3000 SERIES.

A complete manual for the device Monessen Hearth 3000 SERIES, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Monessen Hearth 3000 SERIES by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Monessen Hearth 3000 SERIES.

A complete Monessen Hearth manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Monessen Hearth 3000 SERIES - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Monessen Hearth 3000 SERIES, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Monessen Hearth 3000 SERIES, that we can find in the current document
3. Tips how to use the basic functions of the device Monessen Hearth 3000 SERIES - which should help us in our first steps of using Monessen Hearth 3000 SERIES
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Monessen Hearth 3000 SERIES
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Monessen Hearth 3000 SERIES in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Monessen Hearth 3000 SERIES?

Use the form below

If you did not solve your problem by using a manual Monessen Hearth 3000 SERIES, ask a question using the form below. If a user had a similar problem with Monessen Hearth 3000 SERIES it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)