Manual Westermo DIN-rail Tele V.90 modem TDW-33

20 pages 9.04 mb
Download

Go to site of 20

Summary
  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 1

    TDW-33 DIN-r ail T ele V .90 modem www .westermo .com REV .A  6619-2202    2008.05  Mälartr yck  AB,  Eskilstuna,  Sweden © W estermo  T eleindustri  AB User  Guide  6619-2202 ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 2

    2 6619-2202 Legal  information The  contents of  this  document are  pr ovided  “as is”.  Except  as  r equired by  applicable  la w ,   no  warranties of  any kind,   either  express or  implied,   including,   but not  limited  to ,   the  implied warranties  of merchantabili ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 3

    3 6619-2202 Safety Befor e  installation: This  modem  is  for restricted access  area  use only .   Read  this  manual completely  and  gather  all information  on  the  unit.   Make sure  that  y ou  understand  it  fully .   Check  that  y our  application  does  not exceed  t ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 4

    4 6619-2202 Agency appr o vals  and  standards  compliance T ype Appro val  /  Compliance EMC EN  61000-6-2,   Immunity  industrial environm EN  55024,   Immunity  IT equipment EN  61000-6-3,   Emission  residential envir onments FCC  part  15  Class  B EN  50121-4,   Railwa y  signalling  and  ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 5

    5 6619-2202 If  tr ouble  is  experienced with  this  equipment  TD W -33,   for repair  or warranty  information,   please  contact  W estermo  Data  Communication,Inc.   11200  W estheimer ,Suit  900.   Houston,TX,,77042.     Phone  number:   713-240-0367.   If  the  equipment  is causin ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 6

    6 6619-2201 Declaration  of  Conformity W es term o Tel eindustr i AB Declar ation of con formi ty Org.nr/ Postadres s/Postal ad dress Tel. Tel efa x Pos tgiro Bankgir o Corp. i dentity n umber Registe red office S-640 40 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna Sweden Int+46 16428000 Int+46 16428001 The ma ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 7

    7 6619-2201 T ype  tests  and  en vironmental conditions Electromagnetic Compatibility Phenomena T est Description T est  lev els ESD EN 61000-4-2 Enclosure  contact  ± 6  kV Enclosure air ±  8 kV RF field  AM   modulated  IEC 61000-4-3 Enclosure 20  V/m 80%  AM  (1  kHz),   80  – 2000  ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 8

    8 6619-2202 Description The  TD W -33  is  designed  to  function reliably within  industrial  envir onments  and  in  ar eas  of  high  le vel interference.   The  modem  has  an  RS-232  interface  supporting  terminal  data  rates  up  to  115 kbit/s. The  TD W -33  is  a  V .90 ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 9

    9 6619-2202 Interface  specifications **    T o mini mise  the risk of   in terf er enc e,   a shie lded  cable is   r eco mmen ded whe n the cabl e is loca ted ins ide 3 m  bou ndary to the rai ls and   co nnec ted to thi s port.   The   ca ble shi eld sho uld be   pr operl y? ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 10

    P osition RJ-11C Direction* Description Pr oduct  marking    PSTN a Not  Connected b Not  Connected c In/Out PSTN  T ransmit/  Receive d In/Out PSTN  T ransmit/  Receive e Not  Connected  f Not  Connected P osition Scre w    terminal* Direction* Description – Not  Connected Data  Carrier  Dir ect  (DCD) No . ? ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 11

    11 6619-2202 LED  Indicators LED Status Description TD  T ransmit  data OFF No data  ON  / FLASH The  modem  receiving data  on  the  DTE interface RD  Receive data OFF No  data ON  / FLASH The  modem  transmitting  data  on the  DTE  interface R TS  Request   to send OFF R TS  signal  ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 12

    12 6619-2202 Cooling This  unit  uses  con vection cooling.   T o  a void  obstructing the  air - flow around  the unit,   use  the  follo wing  spacing  rules.   Minimum  spacing  25  mm  (1.0 inch)  above /below  and  10  mm  (0.4 inches)  left  /right  the  unit.   Spacing  ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 13

    13 6619-2202 Windo ws  configuration  tool  TD-T ool The  TD-T ool  is  a PC  –  application  pr ogram  with  a  graphical interface  for  easy  configuration  of  the  complex functions  found  on  the  encolsed  CD  or at  the  W estermo  website. Please  r efer  to  TD-T ool? ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 14

    14 6619-2202   PSTN  Network Application  examples …    TD W -33  connected  to  TD W -33  with  DTR  signal  call DTR DSR DCD Rela y External application 10  k ohm Ma y  be required in  harsh environments. Configure the  units A T&F Set  the unit  to  factor y  default A T&W Store defau ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 15

    15 6619-2202   …    Fr equently  used  settings  for PLC-systems  Most  PLC-systems  and  other industrial  applications  where modems  are used  requir e  the  same  changes  to  the standard  settings. The  most  commonly encountered problems  concern speed,   parity  and  cont ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 16

    16 6619-2202 …    TD W -33  –  Secure Call-back The  TD W -33  is  connected  to  a PLC  which  one  want  to  restrict access  to.   The  TD W -33  can  support  access  control through the  Secure  Callback function.   In  this  example  pass- wor d  and  callback  to  ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 17

    17 6619-2202 Configure the  TD-36  Set  up the  connection  A T&F Set  the unit  to  factor y  default A T+IPR=9600 DTE  baudrate 9600 A T+ICF=3,4 Character  framing 8  data,   1  stop ,   parity none A TS0=1 Auto  answ er  after  first  ring A T&W Store default  settings The  dialling ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 18

    18 6619-2202 …    TD W -33  –  Silent  answ ering  on  pr edefined  number The  TD W -33  is  connected  to  a power meter  which  is  remotely monitored.   The  TD W -33  shares the  PSTN  line  with  normal  telephones which  is  prefer red not  to  give a  ring  signal ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 19

    ...

  • Westermo DIN-rail Tele V.90 modem TDW-33 - page 20

    REV .A  6619-2202    2008.05  Mälartr yck  AB,  Eskilstuna,  Sweden W estermo  T eleindustri  AB  • SE-640  40  Stora  Sundby ,   Sw eden Phone  +46 16  42  80  00  Fax  +46 16  42  80  01  E-mail:   info@w estermo.se  W estermo  W eb  site:   www .westermo .com W estermo T eleindus ...

Manufacturer Westermo Category Network Router

Documents that we receive from a manufacturer of a Westermo DIN-rail Tele V.90 modem TDW-33 can be divided into several groups. They are, among others:
- Westermo technical drawings
- DIN-rail Tele V.90 modem TDW-33 manuals
- Westermo product data sheets
- information booklets
- or energy labels Westermo DIN-rail Tele V.90 modem TDW-33
All of them are important, but the most important information from the point of view of use of the device are in the user manual Westermo DIN-rail Tele V.90 modem TDW-33.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Westermo DIN-rail Tele V.90 modem TDW-33, service manual, brief instructions and user manuals Westermo DIN-rail Tele V.90 modem TDW-33. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Westermo DIN-rail Tele V.90 modem TDW-33.

Similar manuals

A complete manual for the device Westermo DIN-rail Tele V.90 modem TDW-33, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Westermo DIN-rail Tele V.90 modem TDW-33 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Westermo DIN-rail Tele V.90 modem TDW-33.

A complete Westermo manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Westermo DIN-rail Tele V.90 modem TDW-33 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Westermo DIN-rail Tele V.90 modem TDW-33, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Westermo DIN-rail Tele V.90 modem TDW-33, that we can find in the current document
3. Tips how to use the basic functions of the device Westermo DIN-rail Tele V.90 modem TDW-33 - which should help us in our first steps of using Westermo DIN-rail Tele V.90 modem TDW-33
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Westermo DIN-rail Tele V.90 modem TDW-33
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Westermo DIN-rail Tele V.90 modem TDW-33 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Westermo DIN-rail Tele V.90 modem TDW-33?

Use the form below

If you did not solve your problem by using a manual Westermo DIN-rail Tele V.90 modem TDW-33, ask a question using the form below. If a user had a similar problem with Westermo DIN-rail Tele V.90 modem TDW-33 it is likely that he will want to share the way to solve it.

Copy the text from the picture