Manual Honeywell Vista-50P/Vista-50PUL

48 pages 0.4 mb
Download

Go to site of 48

Summary
  • Honeywell Vista-50P/Vista-50PUL - page 1

    VISTA50 P-PRV2 5/04 Rev A   $ $ ' ' ( ( 0 0 & & 2 2   9 9 , , 6 6 7 7 $ $   6 6 ( ( 5 5 , , ( ( 6 6   9 9 , , 6 6 7 7 $ $       3 3   9 9 , , 6 6 7 7 $ $       3 3 8 8 / /   &RPPHUFLDO%XUJODU 3DUWLWLRQHG6HFXULW6VWHP :LWK6FKHGXOLQJ ? ...

  • Honeywell Vista-50P/Vista-50PUL - page 2

    – 2 – Table of Contents Recommend ed Programm ing Procedur e ................. 3 Program Fie ld Index ................................................. 4 VISTA-50 P/VIST A-50PUL Progra mming Form ........ 5 Partitio n-Specif ic Field s .......................................... 10 Programmi ng With #93 Menu Mode ....................... 12 Zone ...

  • Honeywell Vista-50P/Vista-50PUL - page 3

    – 3 – Recommended Programming Procedure The foll owing is a step- by-step pr ocedur e reco mmended for progr amming your VI STA-50P/ VIST A-50PU L syste m. 1. Set the k eypads ( and other p eripher al devices) to the ap propriat e addres ses. 2. Set factor y default s by pr essing ✱ 97. This will automa ticall y enable keypad a ddress es 00-0 ...

  • Honeywell Vista-50P/Vista-50PUL - page 4

    – 4 – Program Field Index On the follow ing pages , the pr ogramming fields have be en arranged in numerical order. Us e this index to cross -reference the fields on th e programming f orm. Field Group Field Group Field Group *00 System -Wide *02 # 93 Menu M ode *03 # 93 Menu M ode *04 # 93 Menu M ode *05 # 93 Menu M ode *09 Partition-Specif ic ...

  • Honeywell Vista-50P/Vista-50PUL - page 5

    – 5 – VISTA-50P/VISTA-50PUL Programming Form Some fields are pr ogrammed for each partitio n (shown as s haded fields). If y ou are progr amming a multip le-partition system, see the Partiti on-Specific Fields s ection for program ming thes e fields. Standa rd default (*9 7) values are s hown in brack ets [ ]. *00 INSTALLER CODE | | | Enter 4 d ...

  • Honeywell Vista-50P/Vista-50PUL - page 6

    – 6 – *39 ENABLE OPEN/CLOSE REPORT FOR [0] INSTALLER CODE 1=enable; 0=disable *40 OPEN/CLOSE REPORT FOR KEYSWITCH [0] 1=enable; 0=disable * 41 NORMALLY CLOSED or EO LR (Zones 2-8) [1] 1=N.C.loops; 0=EOLR supervision. Must be "0" f or UL inst allations. *42 DIAL TONE PAUSE [0] 0=5 seconds; 1=11 seconds; 2=30 seconds. Must be "0&qu ...

  • Honeywell Vista-50P/Vista-50PUL - page 7

    – 7 – *80 *8 1 SYSTEM NON-ALARM CODES E nter 00-09; B-F (11-15). Default = 00 for all reports *80 1st Digit *81 2nd Digit Close | | Open | | Low Batte ry | | Low Batte ry Restore | | AC Loss | | AC Restore | | Test | | Power Up | | Cancel | | Progra m Tampe r | | *83 FIRST TEST REPORT TIME | | | [Day 00; hour 12; min 00] Days 01-07 Hours 00-23 ...

  • Honeywell Vista-50P/Vista-50PUL - page 8

    – 8 – 1*40 1*41 NON-ALARM DIALER CODES E nter 00-09; B-F (11-15). Default = 00 for all reports 1*40 1st Digit 1*41 2nd Digit Armed STAY | | Time/Da te Set o r Event Log Reset | | Event Lo g 50% & 90% Full | | Event Log Overflow | | Exit Error (Zone) | | Exit Error (Use r) | | Recent Close | | 1*42 CALL WAITING DEFEAT [0] 1=Yes; 0=No 1*43 PE ...

  • Honeywell Vista-50P/Vista-50PUL - page 9

    – 9 – 2*06 AUTO-ARM WARNING PERI OD [15] | This is the time during which the user is warned to exit the premises prior to the auto-arm ing of the system (beeps every 15 seconds; "ALERT" displ ayed). Enter 01-15 minutes. 00=instant at end of arming delay. 2*07 AUTO-DISARM DELAY [15] | This is the time between the end of the disarming w ...

  • Honeywell Vista-50P/Vista-50PUL - page 10

    – 10 – Partition-Specifi c Fields (Duplicate this p age for e ach partition in the install ation.) To program these fields, 1. Press *91 to se lect a partiti on. 2. Enter a partit ion-spe cific f ield numb er (ex. * 09). 3. Make th e requir ed entry. 4. Repeat steps 1- 3 for each partit ion in the system. PARTITION #____ PROGRAM FIELDS 1st Page ...

  • Honeywell Vista-50P/Vista-50PUL - page 11

    – 11 – 3rd Page Programmi ng Fields (press *94) 2*05 AUTO-ARM DELAY [15] | Enter the time between the end of the arming window and the start of auto-armi ng warning period, in values of 1-14 times 4 minutes 00=instant; [15=no auto arm at all]. When this delay expires , the Auto-Arm Warning Period begins. 2*06 AUTO-ARM WARNING PERI OD [15] | Thi ...

  • Honeywell Vista-50P/Vista-50PUL - page 12

    – 12 – Programming With #93 Menu Mode NOTE: The following field should be preset before beginning: 2*00 N umber of Partiti ons. In addition, rec eivers s hould be programmed via De vice pr ogramming. Afte r prog rammi ng all syst em r ela ted pro grammi ng fi elds in the usu al way, press # 93 whil e still in prog rammi ng mode t o display the ...

  • Honeywell Vista-50P/Vista-50PUL - page 13

    – 13 – Zone Programming If using 580 0 Series trans mitters, do not the instal l batteries until y ou are r eady to enroll t hem. After enro lling the transm itter, the battery need not be removed. This is to pr event enroll ing the wro ng seria l number. PROM PT EXPLANATION ZONE PROG? 1 = YES 0 = NO 0 Pres s 1 to enter ZONE PROGRAMMING mode. T ...

  • Honeywell Vista-50P/Vista-50PUL - page 14

    – 14 – PROM PT EXPLANATION 10 IN PUT TY PE RF Xmit ter 3 Input types 4 & 5 are valid for certain 5800 Series transmitters only (e.g., 5801, 5802, 5802CP & 5803). Enter the input devic e type as follows: 00 = not used 01 = hardwired 03 = supervised RF transmitter (RF type) 04 = unsupervised RF transmitter (UR type) 05 = RF button-type tr ...

  • Honeywell Vista-50P/Vista-50PUL - page 15

    – 15 – 5800 Series Transmitters Loop Designations LOOP 1 5802MN ENROLL AS "UR" OR "RF" Y OU MUST ENROLL THIS BUTT ON LOOP 3 LOOP 1 LOOP 2 LOOP 4 LOOP 1 5808 ENROLL AS "RF" 5804 ENROLL AS "BR" 5817 ENROLL AS "RF" LOOP 1 (PRIMAR Y) LOOP 2 (A UX. CENTER) LOOP 3 (A UX. RIGHT) LOOP 1 (MOTION) 5890 EN ...

  • Honeywell Vista-50P/Vista-50PUL - page 16

    – 16 – PROM PT EXPLANATION ENTER ZONE N O. 00 = QUIT 11 The s ystem n ow re turn s to th e “ E NTER ZON E NO. ” prompt for the next zone. When all zones have been programmed, enter “ 00 ” to quit . After you have e nrolled eac h wireless devi ce, remove O NE of the serial number labels from th at device and affix it in the appropriate c ...

  • Honeywell Vista-50P/Vista-50PUL - page 17

    – 17 – PROM PT EXPLANATION Zn Z T P RC In L 10 03 1 1 0 RF - Enter all zone info rmation except for Loop number, or press “ C ” to copy the zone information on this screen from the last saved zone (including Loop). ZT = Zone Type P = Partit ion RC = Report Code In = Input Device Type L = Loop number to which the sensor is connected. NOTE: P ...

  • Honeywell Vista-50P/Vista-50PUL - page 18

    – 18 – Entering Wireless Keys If you press ed the D key previously to enter defau lts for 580 4 and/or 5804BD wireless keys, the fol lowing sc reens appea r: PROM PT EXPLANATION FROM TEMPLA TE 1 – 6 1 Enter templa te numb er (1 – 6). 1 – 3 = 5804 templates; 4 – 6 = 5804BD templates. See the defaults provided for each template in the cha ...

  • Honeywell Vista-50P/Vista-50PUL - page 19

    – 19 – Wireless Ke y Default Tem plates 5804 5804 BD Template 1 Loop Function Zone Type Template 4 Loop Function Zone Type 1 No R esponse 23 1 No Respons e 23 2 Disarming 22 2 No Response 23 3 Arm AWAY 21 3 Arm AWAY 21 4 No Response 23 4 Disarming 22 Template 2 Loop Function Zone Type Template 5 Loop Function Zone Type 1 No R esponse 23 1 No Re ...

  • Honeywell Vista-50P/Vista-50PUL - page 20

    – 20 – Alpha Descript ors Programming You can program a user-frie ndly Englis h languag e descript ion/locati on for all pr otection z ones, relay s, keypad pa nics, pol ling loop short, a nd RF rece iver supervis ion troubles . Each desc ription can b e composed of a combinat ion of words (up to 3) that are s elected fr om a v ocabulary of 244 ...

  • Honeywell Vista-50P/Vista-50PUL - page 21

    – 21 – 4. Accept the word. To accept th e word, press [6] , which s witches bac k to the alp habet list for the next word , or press [8] to store the complete des criptor an d then ex it. 5. Select the next word. For selectio n of the nex t word (DOO R), repeat step 3a (w ord #057) or 3 b, but select ing the word "DOOR. ” To accept th e ...

  • Honeywell Vista-50P/Vista-50PUL - page 22

    – 22 – 2. Enter the custom word number (01-20) you want to create. For example, if you are c reating the f irst word (or w ord string) , enter 01 ; when c reating the second word, enter 02 , and so on. A cursor now appears at t he beginn ing of the s econd line . 3. Type the word using one of t wo methods as f ollows: a) Press [#], followed by ...

  • Honeywell Vista-50P/Vista-50PUL - page 23

    – 23 – Alpha Descript or Vocabulary (For entering al pha desc riptors. To s elect a word, press [#] f ollowed by th e word ’ s 3-digit number.) NOTE: This vocabulary is not to be used for re lay voice des criptors. See the Relay Voice Des criptors section when programming r elay voice d escriptors . 000 (Wo rd S pace) • 001 AIR • 002 ALAR ...

  • Honeywell Vista-50P/Vista-50PUL - page 24

    – 24 – Device Programming This menu is used to pr ogram k eypads, receiv ers, and relay modules, etc . Device Addre ss 00 is alw ays set as an alpha key pad ass igned to Partiti on 1 with no s ounder s uppression options, and these sett ings ca nnot be chan ged. From Data Field Programming mode, press #9 3 to di spla y "ZONE PROG?" Pr ...

  • Honeywell Vista-50P/Vista-50PUL - page 25

    – 25 – Relay Programming The system s upports up to 16 relay s. Relays can be used to perform many different fu nctions and actions. Eac h output must be programm ed to begin o ne of three ty pes of ACTIONS at a design ated START event , and end th at ACTION at a designated STOP event. Th e options used to start and stop thes e devices are desc ...

  • Honeywell Vista-50P/Vista-50PUL - page 26

    – 26 – Relay Device s Programming From Data Field Programming Mode, press #9 3 to display th e "ZONE PROG ?" prompt. Pr ess [0] (NO) to eac h menu opt ion until the "R ELAY PGM?" prom pt appears. Pres s [1] (YES). While in this mode, pres s [ ✱ ] to adv ance to nex t screen. Pr ess [#] to bac k up to the previous screen. P ...

  • Honeywell Vista-50P/Vista-50PUL - page 27

    – 27 – PROM PT EXPLANATION 02 ST ART: PARTN ANY PAR TITION 0 If the starting event will be limit ed to occurring on a specific partition, enter the partiti on number ( 1-8 ) in which the start event wil l occur. Enter 0 for any partition. Pres s [ ✱ ] to continue. Do not use a z one progr ammed with an RF Button (Inp ut Type BR ) to STOP a re ...

  • Honeywell Vista-50P/Vista-50PUL - page 28

    – 28 – If you are def ining a zon e list, continue to t he next s ection. If not, enter 00 + [ ✱ ] at the next two prompts. Yo u will then be asked "Quit M enu Mode? " Enter 1 for "Yes ," 0 for "No. " Then ente r ✱ 99 to exit programm ing completely . Zone List Programming After all relay s have bee n program m ...

  • Honeywell Vista-50P/Vista-50PUL - page 29

    – 29 – PROM PT EXPLANATION 01 ENTER DESC d1 From the Relay Voice Descri ptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index number for the first word of the relay descri ptor phrase. Pres s [ ✱ ] to accept entry. 01 ENTER DESC d2 From the Relay Voice Descri ptors and Custom Word Substitutes Vocabulary list, enter the 3- ...

  • Honeywell Vista-50P/Vista-50PUL - page 30

    – 30 – Custom Word Substitutes for VIP Module Annunciation A substitute wor d can be pro gramm ed for each of th e 20 cust om words used in y our alpha z one descriptions. The VIP Module announces this substitut e word in place of the custom word that is d isplayed on the alpha keypad. F or example, an alarm display of "John ’ s Bedroom& ...

  • Honeywell Vista-50P/Vista-50PUL - page 31

    – 31 – System Layout Worksheet s Before programmin g any security syst em, you should first define the inst allation. T o help you lay out a partitioned system, use the f ollowing w orksheets. Thi s will further s implify the progr amming process. PARTITIONS Partitio n # Descriptor (4-char max) Prim. Sub. # Sec. Sub. # Alpha Default Message (32 ...

  • Honeywell Vista-50P/Vista-50PUL - page 32

    – 32 – PRINTER OPTIONS 12- or 24-hour Time format Printer On-Li ne (yes/no) 1200 or 300 baud Printer Baud Rate EVENT LOG TYPES Option No Yes Alarm Trouble Bypa ss Open/Close Syste m DEVICES (keypads, 4 204, rf receivers, vip module) Addr Type Part Sound Opt House ID 00. 01. 02. 03. 04. 05. 06. 07. 08. 09. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. ...

  • Honeywell Vista-50P/Vista-50PUL - page 33

    — 33 — ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 3 & 4 Partitio n 3 Partition 4 4-digit Security Code Access Group 0; 1-8 2-Digit User # Auth. Level Open/ Close RF Key Global Arm 2-Digit User # Auth. Level Open/ Close RF Key Global Arm ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 5 & 6 Partitio n 5 Partition 6 4-digit Sec ...

  • Honeywell Vista-50P/Vista-50PUL - page 34

    — 34 — Zone Information (part nu mbers) & Alpha Descriptor (3 words max.) Rpt. Code Serial # / Loop Input Type Part 1-8 Zone Type ZONE DEFINITION FOR ZONES 01-25 Zone No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 ...

  • Honeywell Vista-50P/Vista-50PUL - page 35

    — 35 — Zone Information (part nu mbers) & Alpha Descriptor (3 words max.) Rpt. Code Serial # / L oop Input Type Part 1-8 Zone Type ZONE DEFINITION FOR ZONES 26-50 Zone No. 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 ...

  • Honeywell Vista-50P/Vista-50PUL - page 36

    — 36 — Zone Information (part nu mbers) & Alpha Descriptor (3 words max.) Rpt. Code Serial # / L oop Input Type Part 1-8 Zone Type ZONE DEFINITION FOR ZONES 51-75 Zone No. 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 ...

  • Honeywell Vista-50P/Vista-50PUL - page 37

    — 37 — Zone Information (part nu mbers) & Alpha Descriptor (3 words max.) Rpt. Code Serial # / L oop Input Type Part 1-8 Zone Type ZONE DEFINITION FOR ZONES 76-86 Zone No. 76 77 78 79 80 81 82 83 84 85 86 ...

  • Honeywell Vista-50P/Vista-50PUL - page 38

    — 38 — ZONE DEFINITIONS FOR KEYPAD PANIC ZONES 95, 96, & 99 Enter yes/ no for each partition-field *2 2 Zone No. Zone Type 1 2 3 4 5 6 7 8 Report Code Zone Information (part nu mbers) & Alpha Descriptor (3 words m ax.) 9 5 9 6 9 9 ZONE DEFINITIONS FOR SYSTE M ZONES; 88; 89, 90, 91, 9 7 & 98 Zone No. Zone Type Report Code Zone Inform ...

  • Honeywell Vista-50P/Vista-50PUL - page 39

    — 39 — Relay Devi ces Worksheet s Applicable only if rela ys (4204) , or X- 10 devic es are used .  Relays are pro grammed in the #93 Men u Mode in t he Relay Program ming Secti on. Fill in the required data on the worksheet bel ow and fol low the proc edure i n the Instal lation and Set up Guide as you enter the data d uring the dis plays a ...

  • Honeywell Vista-50P/Vista-50PUL - page 40

    — 40 — ZT = ZONE TYPE/SYSTEM OPERATION Choices for Star t/Stop Zone Types and System Oper ations: 00 = No Response (Not Used) 23 = No Alarm Response 43 = Communication failure 01 = Entry/Exit #1 31 = End of Exit Time 44 = RF Low Battery 02 = Entry/exit #2 32 = Start of Entry Time 45 = Polling Loop Failure 03 = Perimeter 33 = Any Burglary Alarm ...

  • Honeywell Vista-50P/Vista-50PUL - page 41

    — 41 — Zone List 7: St arted or stop ped by zone n umbers (enter 000 to end entries). Zone List 8: St arted or stop ped by zone n umbers (enter 000 to end entries). Scheduling Menu Pro mpts To program s chedules, enter Scheduling pr ogram mode by pres sing [User Code] + # + 80 to d isplay th e first choice of the menu driven programm ing func t ...

  • Honeywell Vista-50P/Vista-50PUL - page 42

    — 42 — Scheduling Worksheets Time Windows Defi nitions Workshe et . The syst em pr ovide s 20 t ime win dows th at are define d with st art an d sto p times. They are program med in th e #80 Menu M ode. Fill in the r equired data on the works heet below and follow the procedur e in the installa tion instruc tions as you enter the data dur ing t ...

  • Honeywell Vista-50P/Vista-50PUL - page 43

    — 43 — Holiday Schedul e Worksheet: The system provi des u p to 16 holi days th at can be assi gned for the syste m. Each holi day can be ass igned to any combinatio n of partitio ns. Fill in the r equired data o n the works heet below and follow th e procedur e in the installa tion instruc tions as you enter the data dur ing the d isplays and ...

  • Honeywell Vista-50P/Vista-50PUL - page 44

    — 44 — Below is a list of the "Action" codes (desired ac tions) us ed when pr ogramming tim e-driven events. Note t hat these c odes are independent of the "r elay code s" programmed d uring the #9 3 Menu M ode – Relay Progr amming mod e. If using Time Driv en Events, the foll owing menu items m ust first be progr ammed us ...

  • Honeywell Vista-50P/Vista-50PUL - page 45

    — 45 — Temporary Sched ule #81 Me nu Mode . The syste m pro vides a Tempo rary S c hedule f or each partition . Enter the tem porary scheduling mode by pr essing [ Installer Code] + [#] + [ 81] . Fill in the requir ed data on th e work sheet below and follow t he procedure in t he install ation in structions as you enter the dat a during the d ...

  • Honeywell Vista-50P/Vista-50PUL - page 46

    — 46 — Partition/Windows Mon Tue Wed Thu Fri Sat Sun 7 Disar m Window Start Time HH:MM Stop Time HH:MM Arm Window Start Time HH:MM Stop Time HH:MM 8 Disar m Window S t a r t T i m e H H : M M S t o p T i m e H H : M M Arm Window S t a r t T i m e H H : M M S t o p T i m e H H : M M ...

  • Honeywell Vista-50P/Vista-50PUL - page 47

    — 47 — VISTA-50P/VISTA-50PUL Summary of Connections Diagram V50P_PUL-SOC-V1 ++ – N.C. N.C. N.O. 2k EOLR (note 1) 2k EOLR (note 1) + – + – + – BELL SIREN NO CONNECTION TRANSFORMER 16.5VAC, 40VA ADEMCO No.1361 (IN CANADA USE No. 1361CN) OR 1361X10 IF X-10 DEVICES WILL BE USED Connect to 24hr. 120VAC, 60 Hz Outlet Red Blk Grn Yel REMOTE KE ...

  • Honeywell Vista-50P/Vista-50PUL - page 48

    ¬9,67$3359 l VISTA50P-PRV2 5/04 Re v. A 165 Eileen Wa y , Syosset, New Y ork 11791 Cop yright © 2004 Honeywell International, Inc. www .honeywell.com/security ...

Manufacturer Honeywell Category Home Security System

Documents that we receive from a manufacturer of a Honeywell Vista-50P/Vista-50PUL can be divided into several groups. They are, among others:
- Honeywell technical drawings
- Vista-50P/Vista-50PUL manuals
- Honeywell product data sheets
- information booklets
- or energy labels Honeywell Vista-50P/Vista-50PUL
All of them are important, but the most important information from the point of view of use of the device are in the user manual Honeywell Vista-50P/Vista-50PUL.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Honeywell Vista-50P/Vista-50PUL, service manual, brief instructions and user manuals Honeywell Vista-50P/Vista-50PUL. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Honeywell Vista-50P/Vista-50PUL.

Similar manuals

A complete manual for the device Honeywell Vista-50P/Vista-50PUL, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Honeywell Vista-50P/Vista-50PUL by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Honeywell Vista-50P/Vista-50PUL.

A complete Honeywell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Honeywell Vista-50P/Vista-50PUL - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Honeywell Vista-50P/Vista-50PUL, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Honeywell Vista-50P/Vista-50PUL, that we can find in the current document
3. Tips how to use the basic functions of the device Honeywell Vista-50P/Vista-50PUL - which should help us in our first steps of using Honeywell Vista-50P/Vista-50PUL
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Honeywell Vista-50P/Vista-50PUL
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Honeywell Vista-50P/Vista-50PUL in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Honeywell Vista-50P/Vista-50PUL?

Use the form below

If you did not solve your problem by using a manual Honeywell Vista-50P/Vista-50PUL, ask a question using the form below. If a user had a similar problem with Honeywell Vista-50P/Vista-50PUL it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)