Manual Fujitsu M10-4S

520 pages 28.03 mb
Download

Go to site of 520

Summary
  • Fujitsu M10-4S - page 1

    Fujitsu M10-4/Fujitsu M10-4S/ SP ARC M10-4/SP ARC M10-4S Ser vice Manual Manual Code: C120-E682 -06EN December 2013 ...

  • Fujitsu M10-4S - page 2

    Copyright © 2007 , 2013, Fuji tsu Lim ited. All rig h ts reserved. Oracle and/ or its affiliates pr ovided technical inpu t and review on portions of this mate rial. Oracle and /or its af filiate s and Fujit su Limit ed each own or cont rol in tellectual property rig hts relating to pr oducts and technol ogy describ ed in this docum ent, and such ...

  • Fujitsu M10-4S - page 3

    Contents Preface xxi Chapter 1 Before Starting Mai ntenance Wor k 1 1.1 Warning /Caut ion Indi cations 1 1.2 Warn ing Labels 2 1.3 Labels/ Tags 2 1.4 Safety Precau tions 5 1.5 Notes Regard ing Stati c Electricity 6 1.6 Other Precaut ions 7 1.7 Emergency Power Off 8 Chapter 2 Understa nding the Syste m Componen ts 11 2.1 Identifying the Names and Lo ...

  • Fujitsu M10-4S - page 4

    Chapter 3 Troublesh ooting 33 3.1 Suspected Failure Cond itions 33 3.2 Determining t he Causes of In dividua l Failur es 33 3.3 Identifying a Failure 34 3.3.1 Checking t he LED in dications 35 3.3.2 Checking err or messag es 35 3.3.3 Checking the status of a compon ent 35 3.3.4 Checking the status of a PCI expansion un it 37 3.3.5 Checking log info ...

  • Fujitsu M10-4S - page 5

    6.1 Incorporating an FRU into the System wi th the replac efru Command 69 6.2 Incorporating a Chassis into a Physica l Partition 71 6.3 Powering On the Phys ical Partiti on Requiring Mai ntenance 73 6.4 Starting the Entire Syst em 74 6.4.1 Starting the system wi th an XSCF command 75 6.4.2 Starting the system fro m the operation panel 75 6.5 Restor ...

  • Fujitsu M10-4S - page 6

    7.5.3 Installing t he CPU memory u nit lower 146 7.5.4 Restoring t he chassis 146 7.6 Restoring the System 147 7.6.1 Active/C old mainten ance 148 7.6.2 Inactive/Col d mainte nance 149 7.6.3 System-s topped maintenance 152 Chapter 8 Maintainin g the Memory 159 8.1 Memory Conf igurat ion 159 8.2 Memory Con figur ation Ru les 163 8.2.1 Memory m ounti ...

  • Fujitsu M10-4S - page 7

    Chapter 9 Maintaini ng the Cross bar Units 179 9.1 Configuration of the Crossbar Units 179 9.2 Before Maint aining a Cr ossbar U nit 180 9.2.1 Types of mainten ance 180 9.2.2 Maintenance f low 1 81 9.3 Enabling the Removal of a Crossbar Unit 181 9.3.1 Active/Cold m aintenance 182 9.3.2 Inactive /Cold mainte nance 18 2 9.3.3 System -stopped mainte n ...

  • Fujitsu M10-4S - page 8

    10.4 Removing a Power Supply Un it 198 10.4.1 Accessing a po wer supply uni t 199 10.4.2 Removing a power su pply unit 199 10.5 Installing a Powe r Supply Un it 20 0 10.5.1 Installing a powe r supply unit 200 10.5.2 Restoring the chass is 200 10.6 Restoring the System 200 10.6.1 Active /Hot mainten ance 201 10.6.2 Active/Cold maint enance 201 10.6. ...

  • Fujitsu M10-4S - page 9

    11.6.1 Ac tive/Hot maintenance 215 11.6.2 Ac tive/Cold maintenance 215 11.6.3 Inactive/ Hot maintenanc e 216 11.6.4 Inac tive/Cold maintenance 216 11.6.5 Syste m-stopped mai ntenance 21 7 Chapter 12 Maintaining the Inte rnal Disks 219 12.1 Configuration of the Internal Disks 219 12.1.1 Identificat ion of disk slot 220 12.2 Before Maintaining an In ...

  • Fujitsu M10-4S - page 10

    Chapter 13 Maintaini ng the PCI Exp ress Cards 239 13.1 Configuration of the PCI Express Cards 239 13.2 Before Maintaining a PCI Express Card 241 13.2.1 Types of maint enance 241 13.2.2 Maintenance flow 241 13.2.3 Precautions for re placement 242 13.2.4 Precautions for insta llation 242 13.2.5 Precautions for remo val 242 13.3 Checking If PCI Hot P ...

  • Fujitsu M10-4S - page 11

    14.2.2 Maintenance f low 267 14.3 Enabling the Removal of the PSU Backplane Unit 267 14.3.1 Ac tive/Cold maintenance 268 14.3.2 Inac tive/Cold maintenance 269 14.3.3 Syste m-stopped mai ntenance 26 9 14.4 Removing the PSU Backplane Unit 270 14.4.1 Accessing the PS U backpla ne unit 271 14.4.2 Removing the PSU backplane un it 273 14.5 Installing the ...

  • Fujitsu M10-4S - page 12

    15.6 Restoring the System 292 15.6.1 Active/Cold maint enance 292 15.6.2 Inactive/Co ld maintenance 293 15.6.3 System -stopped mai ntenance 294 Chapter 16 Maintaini ng the Crossbar Un its of the Crossbar Box 297 16.1 Configuration of the Crossbar Units 297 16.2 Before Maintaining a Crossbar Unit 298 16.2.1 Types of maint enance 298 16.2.2 Maintenan ...

  • Fujitsu M10-4S - page 13

    17.6.1 Ac tive/Hot maintenance 315 17.6.2 Inactive/ Hot maintenanc e 315 17.6.3 Syste m-stopped mai ntenance 31 6 Chapter 18 Maintaining the Power Supply Units of the Crossbar Bo x 317 18.1 Configuration of the Power Supply Units 317 18.2 Before Maintaining a Power Supply Unit 318 18.2.1 Type s of maintenance 318 18.2.2 Maintenance f low 319 18.2.3 ...

  • Fujitsu M10-4S - page 14

    19.4.2 Removing a fan unit 3 32 19.5 Installing a Fan Unit 33 3 19.5.1 Installing a fan unit 333 19.5.2 Restoring the chass is 333 19.6 Restoring the System 333 19.6.1 Active /Hot mainten ance 334 19.6.2 Inact ive/Hot maintenance 334 19.6.3 System -stopped mai ntenance 334 Chapter 20 Maintaini ng the XSCF Int erface Unit of the Crossbar Box 337 20. ...

  • Fujitsu M10-4S - page 15

    22.2.2 Maintenance f low 359 22.3 Enabling the Removal of the Fan Backplane 359 22.4 Removing the Fan Backplane 360 22.4.1 Accessing t he fan back plane 360 22.4.2 Remo ving the fan backplane 361 22.5 Installing the Fan Backplane 365 22.5.1 Insta lling the fan backplane 365 22.5.2 Restoring the chassis 366 22.6 Restoring the System 366 Chapter 2 3 ...

  • Fujitsu M10-4S - page 16

    24.3.2 System -stopped mai ntenance 383 24.4 Removing a Cr ossbar Ca ble (Electrical ) 384 24.5 Installing a C rossbar C able (Elect rical) 385 24.6 Restoring the System 386 24.6.1 Inactive/Co ld maintenance 386 24.6.2 System -stopped mai ntenance 387 Chapter 25 Maintaini ng the Crossbar C ables (Optical) 389 25.1 Configuration of the Ports for the ...

  • Fujitsu M10-4S - page 17

    26.4 Removing an XSCF BB Control Cab le 407 26.5 Installing an XSCF BB Control Cable 409 26.6 Restoring the System 410 26.6.1 Ac tive/Hot maintenance 410 26.6.2 Ac tive/Cold maintenance 410 26.6.3 Inactive/ Hot maintenanc e 411 26.6.4 Inac tive/Cold maintenance 411 26.6.5 Syste m-stopped mai ntenance 41 1 Chapter 27 Maintaini ng the XSCF DUAL C ont ...

  • Fujitsu M10-4S - page 18

    28.1.2 Cables for the conne ction betwe en the termina l board and fan backplane 427 28.1.3 Locations for the cabl e kit 428 28.2 Before Maintaining the Cable K it 429 28.2.1 Types of maint enance 429 28.2.2 Maintenance flow 430 28.3 Enabling the Removal of the Cable Kit 430 28.4 Removing t he Cable Kit 431 28.4.1 Removing the cable s for the conne ...

  • Fujitsu M10-4S - page 19

    29.6.1 Ac tive/Cold maintenance 462 29.6.2 Syste m-stopped mai ntenance 46 2 Appendix A Component List 463 Append ix B C omponen t Specifications 467 B.1 CPU Memory Unit 467 B.2 Crossbar Unit 468 B.3 XSCF Unit 469 B.4 Power Supply Unit 470 B.5 Fan Unit 471 B.6 Internal Disk Dri ve 4 71 B.7 PCI Express Card 472 B.8 XSCF Interface Unit 472 B.9 Backpl ...

  • Fujitsu M10-4S - page 20

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual • December 2013 xx ...

  • Fujitsu M10-4S - page 21

    Preface This documen t descr ibes the main tenance proc edure for Oracle or Fuj itsu SPARC M10-4/M10-4S and t he crossbar box. Th e maintenanc e work should be perf ormed by service engineer s and/or field engineers. Fujitsu M10 is s old as SPARC M10 Sys tems by Fuji tsu in Japan. Fujitsu M1 0 and SPARC M10 System s are identical pro ducts. The pre ...

  • Fujitsu M10-4S - page 22

    Documenta tion Rel ated to S PARC M10 Syst ems (*1) Fujitsu M10/SPARC M10 Systems Getting Started G uide (*2) Fujitsu M10/SPARC M10 Systems Quick Guide Fujitsu M10/SPARC M10 Syste ms Important Leg al and Safety Info rmation (*2) Software L icens e Condit ions for F ujitsu M 10/SPARC M10 S ystems Fujitsu M10/SPARC M10 Systems Safety and Comp liance ...

  • Fujitsu M10-4S - page 23

    Font/Symbol Meaning Example A aBbCc123 What you type, wh en contrast ed with on-sc reen computer o utput. This font indica tes an examp le of command input. XSCF> adduser jsmith AaBbCc123 The names of c ommands, file s, and direc tories; on-screen c omputer o utput. This font indica tes an examp le of command input in the fram e. XSCF> showus ...

  • Fujitsu M10-4S - page 24

    Syntax of the Command-Line Interface (CLI) The com mand synt ax is as fo llows: ■ A variable that r equires the input o f a value m ust be put in Italics. ■ An option al element m ust be enclo sed in []. ■ A group of options for an optional keyword must be enclos ed in [] and delimit ed by |. Document Feedback If you have any comments or re q ...

  • Fujitsu M10-4S - page 25

    Warning - "WARNING" i ndicat es a potent ial hazard that could result i n death or serious p ersonal injury if the user does no t perform the proc edure correc tly. Caution - "CAUTION" ind icates a p otentia l hazard that coul d result i n minor or moderate p ersonal injury if the user does no t perform the proc edure correct ly ...

  • Fujitsu M10-4S - page 26

    Cauti on - Never peel off the la bels. A A A A Note - The contents of the la bels and tags may diff er from those tha t are actual ly affixed. 1.2 Warning Labels Observe the warning lab els (A in the figure) aff ixed on the SPARC M10-4/M10-4S and the cros sbar box during the main tenance work . The warning label on t he crossba r box also descr ibe ...

  • Fujitsu M10-4S - page 27

    A B B A ■ The syst em name plate lab el (A in the f igure) des cribes t he model number, s erial number, and vers ion required f or maintenance and manag ement. ■ The standard la bel (B in the figure) descri bes the following cer tification stand ards. The warning label on th e crossbar box d escribes certifi cation s tandards . SPARC M10-4/M10 ...

  • Fujitsu M10-4S - page 28

    ■ The RFID tag carr ies an Ass et ID. The RFI D tag of the SPARC M10-4/M10 -4S is affixe d on the front cover. Figure 1-5 RFID tag (SPARC M10-4/ M10-4S) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 4 ...

  • Fujitsu M10-4S - page 29

    Figure 1-6 RFID ta g (crossbar box) 1.4 Safety Precautions Observe t he following pr ecautions to protect yourse lf when performing mai ntenance . ■ Observe al l the precau tions, warni ngs, and ins tructions d escribe d on the chass is. ■ Do not insert fo reign objects int o the openings in the ch assis. Any such f oreign object could come in ...

  • Fujitsu M10-4S - page 30

    Table 1-1 ESD precautio ns Item Preca ution Wrist strap Wear an antist atic wrist strap when h andling pr inted boar ds. ESD mat An approved E SD mat provid es protection fr om static dam age when used wit h a wrist strap. Th e mat also acts as a cush ion to protect the small parts t hat are attached to pr inted boards . Antista tic bag/ ESD safe p ...

  • Fujitsu M10-4S - page 31

    Caution - Do not conn ect the wrist str ap clip to the ESD mat. By c onnecting the w rist strap cl ip to the chas sis, the operator and compone nts have th e same level of potential, thus elimin ating the danger of static dam age. A B How to use a wrist strap Wear a wrist str ap in such a way th at the inner metal s urface (A in the fig ure) of the ...

  • Fujitsu M10-4S - page 32

    Cauti on - In an emergency (s uch as smoke or flames c oming from the chass is), immediately stop using the unit an d turn o ff the power supply. Reg ardless of the operation you are pe rforming, give top priority to fi re preven tion. ■ If excessive force is applied to the CPU memory unit, the components mounted o n printed boards may be damaged ...

  • Fujitsu M10-4S - page 33

    Figure 1-8 Removing t he power cord (SPA RC M10-4/M10-4S) Figure 1-9 Removing the po wer cord (cr ossbar bo x) Chapter 1 Before Starting Maintenance Work 9 ...

  • Fujitsu M10-4S - page 34

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 10 ...

  • Fujitsu M10-4S - page 35

    Chapter 2 Understanding the System Components This chapt er desc ribes the c omponents mounted in the SPARC M10-4/M10-4 S and the crossbar box. It is ne cessary to conf irm and fully unde rstand the c onfigurations of the components mounted in the chassis as well as the LED indi cations before start ing any maintenan ce work. ■ Identifying the N ...

  • Fujitsu M10-4S - page 36

    (1) (2) (3) Location numbe r Component 1F a n u n i t 2 Internal d isk 3 Power sup ply unit (1) Figure 2-1 Locations o f compon ents that can be accessed fr om the fro nt (SPARC M10-4/M10-4S) Figure 2-2 Location o f a compo nent that can be acce ssed from the fro nt (crossb ar box) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manua ...

  • Fujitsu M10-4S - page 37

    Location n umber Com ponent 1F a n u n i t (2) (1) Location n umber Com ponent 1 PCI-Express ( PCIe) card cassette 2 Crossbar uni t (Only for the SPARC M10-4 S. The SPARC M10-4 incorpor ates three PCIe card cassettes.) Components that can be acce ssed from the rear Figure 2-3 Locations of co mponents th at can be accessed fro m the rear (SP ARC M10 ...

  • Fujitsu M10-4S - page 38

    (4) (1) (2) (3) Location numbe r Component 1 Power sup ply unit 2X S C F u n i t 3 XSCF inter face unit 4 Crossbar u nit Figure 2-4 Locations o f compon ents that can be accessed fr om the rear (crossb ar box) Internal components To access the interna l components, r emove the CPU memory unit from th e SPARC M10-4/M 10-4S, and the fa n shelf from t ...

  • Fujitsu M10-4S - page 39

    (6) (4) (5) (3) (3) (2) (1) Location n umber Com ponent 1 CPU mem ory unit u pper 2 CPU mem ory unit l ower 3M e m o r y 4 PSU backp lane unit 5 HDD backplane 6 Operation p anel Figure 2-5 Locat ions of internal componen ts (SPARC M10-4/M10-4S) Chapter 2 Understanding the System Components 15 ...

  • Fujitsu M10-4S - page 40

    (2) (1) (3) Location numbe r Component 1 Fan ba ckplane 2 Crossbar b ackplan e unit 3 Operatio n panel Figure 2-6 Locations o f internal co mponents (cr ossbar bo x) 2.2 Confirming the Functions of the Operation Panel This se ction des cribes t he functions of the operation pa nels of the SP ARC M10-4/ M10-4S and the crossbar box. Fujitsu M10-4/Fuj ...

  • Fujitsu M10-4S - page 41

    The operatio n panel pro vides the system's display and co ntrol fun ctions. A field engineer an d the system admini strator can speci fy the operatio n mode or c ontrol the starting/stoppin g of the system while chec king the system operatio n status by referring to the LED in dications. Figure 2-7 Location of the o peration panel (SPARC M 10 ...

  • Fujitsu M10-4S - page 42

    㩿㪈㪀 㩿㪉㪀 㩿㪊㪀 㩿㪋㪀 㩿㪌㪀 㩿㪍㪀 Location numbe r Component 1P O W E R L E D 2 XSCF STANDBY LED Figure 2-8 Location of the oper ation panel (crossb ar box) Figure 2-9 Appearance of op eration pane l (SPARC M10-4/M10-4S an d crossbar box) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 201 ...

  • Fujitsu M10-4S - page 43

    Location n umber Com ponent 3 CHECK LED 4 ID swi tch (SPARC M10-4S and cro ssbar box only) 5M o d e s w i t c h 6 Power switch Table 2-1 Display and oper ation status of oper ation panel LEDs /swi tc hes o n operation pane l If the SPARC M10-4S or the cros sbar box is a cting as the master XSCF If the SPARC M10-4S or the crossbar box is acting as a ...

  • Fujitsu M10-4S - page 44

    㩿㪈㪀 㩿㪉㪀 㩿㪊㪀 Location numbe r Component 1P O W E R L E D 2 XSCF STANDBY LED 3 CHECK LED 㩿㪈㪀 㩿㪉㪀 㩿㪊㪀 Location numbe r Component 1 ID switch (S PARC M10 -4S and cr ossbar box on ly) 2M o d e s w i t c h Figure 2-10 LEDs on op eration pan el (SPARC M10-4 /M10-4S and crossbar box) 2.2.2 Control function of the operati ...

  • Fujitsu M10-4S - page 45

    Location n umber Com ponent 3 Power switch Table 2-2 How to operate the ID swi tch Operati on Descri ption Pressing the + side. The I D numb er increases b y 1. Pressing the - side T he ID nu mber decreases b y 1. Table 2-3 Functions of the mod e switch Icon Name Description Locked m ode This mod e is used for no rmal operat ion. - The power switch ...

  • Fujitsu M10-4S - page 46

    Table 2-4 Functions of t he power swi tch Icon Operation Description Brief press (For 1 second or more an d less tha n 4 seconds) If the system has bee n started in Se rvice m ode (*): Operatio n is ignored. If the system is stopp ed in Service mode: Operatio n is ignored. If the system has bee n started in Locked m ode (*): Operatio n is ignored. ...

  • Fujitsu M10-4S - page 47

    Table 2-5 Functions of the mod e switch (c o ntinu e d ) Functio n Mode swit ch Locked Serv ice Inhibition of break signal reception Enabled . Using t he setpparm ode comman d, it is poss ible to specify whether break signal r eceptio n is allowed or inh ibited for each ph ysical partition. Disabled Table 2-6 System ope ration statu s indicat ed by ...

  • Fujitsu M10-4S - page 48

    Table 2-6 System oper ation stat us indicated by L EDs (c o ntinu e d) Icon Nam e Color Des cription CHEC K Amber Indicates the sy stem oper ation status for e ach chassis. ● On: An error t hat prevents start up was detected. ● Off: Normal, or the pow er is disc onnected or not being suppl ied. ● Blinkin g (*): In dicates th at the chassis re ...

  • Fujitsu M10-4S - page 49

    A Figure 2-12 Locat ion of system loca tor (SPARC M10-4/M10-4S ) Chapter 2 Understanding the System Components 25 ...

  • Fujitsu M10-4S - page 50

    A Table 2-8 Status of the sy stem locat or Icon Name Co lor Description CHECK Amber Indicates the system o peration status f or each chassis. ● On: An error that preve nts startup was de tecte d. ● Off: Norm al, or the power is disconnected or not being supplied. ● Blinking (*): Indi cates t hat the chas sis requi res maintenanc e (this funct ...

  • Fujitsu M10-4S - page 51

    Table 2-9 LEDs on the X SCF or XSC F unit an d their statuses (SPA RC M10 -4/M10- 4S and crossbar bo x) Name Color Status Description READY Green On Indica tes that the c omponent is ope rating. The com ponent cann ot be released and removed from t he system. Blinkin g (*) Indicates th at the compo nent is currently being mo unted on the system or ...

  • Fujitsu M10-4S - page 52

    Table 2-12 LED on th e power supply u nit and its status (S PARC M 10-4/M1 0-4S and cross bar b ox ) Name Color Status Descri ption CHECK Green On Indicates that the input power is turned on and power is being supp lied norma lly. Blinkin g (*) Indicates th at the i nput power is bein g disconnec ted. Amber On Ind icates that an err or has occurred ...

  • Fujitsu M10-4S - page 53

    2.4 Confirming the Types of Cable This section describes the ty pes of the cables that are co nnected to the SPARC M10-4/M10-4S and t he crossbar box, as well as the l ocations of t he cable ports . The type s and number of the cabl es to be used va ry depend ing on the configura tion. 2.4.1 Types of cable In a build ing block c onfiguration, the f ...

  • Fujitsu M10-4S - page 54

    (2) (1) (3) Figure 2-14 Locations of cab le connec tion ports (SPA RC M10-4S) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 30 ...

  • Fujitsu M10-4S - page 55

    (1) (2) (3) Location n umber Con nection p ort 1 XSCF DUA L control po rt 2 XSCF BB control p ort 3 Crossbar cable c onnection port Figure 2-15 Locat ions of cable connect ion ports (crossbar box) Chapter 2 Understanding the System Components 31 ...

  • Fujitsu M10-4S - page 56

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 32 ...

  • Fujitsu M10-4S - page 57

    Chapter 3 Troubleshooting This chapt er desc ribes how to de termine and c onfirm the cause if a n error occurs. ■ Suspected Failur e Conditio ns ■ Determining the Cau ses of Individu al Failur es ■ Identifying a Fail ure ■ Downloading E rror Log Information 3.1 Suspected Failure Conditions This se ction exp lains susp ected fa ilure condi ...

  • Fujitsu M10-4S - page 58

    Start End Is the LED on the power supply unit off? Check the connection of the power supply unit and power cords. YES NO NO YES W as e-mail sent by the XSCF mail function? Check /var/adm/messages on Oracle Solaris. Write down the displayed failure information. Contact our service engineer . Confirm that an error message is displayed on the OS and X ...

  • Fujitsu M10-4S - page 59

    3.3.1 Checking the LED indications Check the LEDs on the operation panel, rear p anel, and on each c ompone nt to ident ify which componen t requires main tenance . Check the s tatus of a component from its LED befo re starting a ny maintena nce work o n that compo nent. ■ Operation p anel LEDs You can che ck the status of the system by checking ...

  • Fujitsu M10-4S - page 60

    XSCF> showhardconf SPARC M10-4 S; + Serial:20812 29003; Operato r_Panel_Swit ch:Service; + System_Power :On; System_Ph ase:Cabinet Po wer On; Partition#0 PP AR_Status:Ru nning; BB#00 Status:N ormal; Role:Ma ster; Ver:2050 h; Serial:20812 29003; + FRU-Part-Num ber:CA07361- D202 A0 ; + Power_Supply _System: ; + Memory_Size: 320 GB; ---------- ---- ...

  • Fujitsu M10-4S - page 61

    Table 3-1 Status of com ponents (c o ntinu e d ) Displa y Descri ption Deconfigur ed Due to the failure or degrada tion of another unit, the target unit and compon ents of its under lying la yer has been deg raded, tho ugh the re is no problem in th em. Maintenan ce Ma intenance is bein g performed . The replacefru , addfru, or initb b command is b ...

  • Fujitsu M10-4S - page 62

    XSCF> showlogs error Date: Oct 20 12:45 :31 JST 2012 Code: 00112233 -44556677889 9aabbcc-8899 aabbcceeff00 11223344 Status: Alarm Occurred: Oct 20 12 :45:31.000 JST 2 012 FRU: PSU#1,PSU #2 Msg: ACFAIL occu rred (ACS=3)(F EP type = A1) Date: Oct 20 15:45 :31 JST 2012 Code: 00112233 -44556677889 9aabbcc-8899 aabbcceeff00 11223344 Status: Warnin g ...

  • Fujitsu M10-4S - page 63

    Table 3-3 Predictive self-repairi ng messages Output Displayed Description Nov 1 16 : 30 : 20 dt88- 292 EVENT-TIME : Tue Nov 1 16 : 30 : 20 PST 2005 EVENT-TIME: Time stamp fo r the diagnosis Nov 1 16 : 30 : 20 dt88- 292 PLATFORM : ORCL,SPARC64-X, CSN : -,HOSTNA ME : dt88-292 PLATF ORM: Descriptio n of the chassis in wh ich the e ...

  • Fujitsu M10-4S - page 64

    Table 3-3 Predictive self-re pairing messages (c o nt inu e d ) Output Displayed Description Nov 1 16 : 30 : 20 dt88-292 REC- ACTION : Schedule a repair proc edure to repl ace the aff ected device.Use Nov 1 16 : 30 : 20 dt88-292 fm dump -v – u EVENT _ID to identify th e device or contact Su n for support. REC-A CTION: Brief d escription ...

  • Fujitsu M10-4S - page 65

    Table 4-1 Maintenanc e tools Item Us e 1 Phillips screwdr iver (No. 2) Removin g or repl acing screws 2 Flathead s crewdriver (sm all) Removin g or r eplacing screws 3 Wrist s trap F or grounding sta tic 4 ESD mat For grounding static Chapter 4 Preparing for Maintenance This chapter describes the pr eparation s that mu st be com pleted prior to per ...

  • Fujitsu M10-4S - page 66

    XSCF> showhardconf Table 4-2 Comm ands fo r checking th e software c onfigur ation Command Descri ptio n pkg(1) (Oracle Sola ris 11) showrev( 1M) (Or acle Solaris 1 0) Displays Oracle So laris correction in format ion and version. ldm(1 M) Displays logical do main config uration inform ation. system, re cord the syst em configuration and the sta ...

  • Fujitsu M10-4S - page 67

    # pkg info entire Name: entire Summary: entir e incorporatio n including Suppo rt Repository Upd ate (Oracle Solari s 11.1.12.5.0) . # showrev -p # ldm -V Logical Domai ns Manager (v 3.1) Hypervisor con trol protocol v 1.9 Using Hypervis or MD v 1.3 Table 4-3 Commands for checking th e firmware confi guration Command Desc ripti on version Displays ...

  • Fujitsu M10-4S - page 68

    XSCF> version -c xcp Table 4-4 System conf igurat ion Configuration Descr iption Single-ch assis config uration Conf iguratio n in which a sin gle SPAR C M10-4 is used Building blo ck config uration Config uration in w hich 2 or more S PARC M 10-4S's are combined an d used 1. Log in to the XSCF s hell . 2. Execute the version command to det ...

  • Fujitsu M10-4S - page 69

    Physical partition (active) BB#0 Hot XBBOX Hot BB#1 Hot Physical partition (active) BB#3 Hot BB#4 Hot Physical partition (active) BB#2 Hot Physical partition (active) BB#5 Hot Physical partition (active) BB#0 Hot XBBOX Hot BB#1 Hot Physical partition (active) BB#3 Hot BB#4 Hot Physical partition (active) BB#2 Hot Physical partition (active) BB#5 Ho ...

  • Fujitsu M10-4S - page 70

    Physical partition (active) BB#0 Cold XBBOX Hot BB#1 Hot Physical partition (active) BB#3 Hot BB#4 Hot Physical partition (active) BB#2 Hot Physical partition (active) BB#5 Hot Physical partition (active) BB#0 Hot PDU Cold PDU Hot BB#1 Hot XBBOX Hot Physical partition (active) BB#2 Hot BB#3 Hot BB#4 Hot Physical partition (active) Figure 4-3 Active ...

  • Fujitsu M10-4S - page 71

    Physical partition (stopped) BB#0 Hot XBBOX Hot BB#1 Hot Physical partition (active) BB#3 Hot BB#4 Hot Physical partition (active) BB#2 Hot Physical partition (active) BB#5 Hot Physical partition (stopped) BB#0 Hot XBBOX Hot BB#1 Hot Physical partition (active) BB#3 Hot BB#4 Hot Physical partition (active) BB#2 Hot Physical partition (active) BB#5 ...

  • Fujitsu M10-4S - page 72

    Physical partition (stopped) BB#0 Cold XBBOX Hot BB#1 Hot Physical partition (active) BB#3 Hot BB#4 Hot Physical partition (active) BB#2 Hot Physical partition (active) BB#5 Hot Physical partition (stopped) BB#0 Cold XBBOX Hot BB#1 Hot Physical partition (stopped) BB#3 Hot BB#4 Hot Physical partition (stopped) BB#2 Hot Physical partition (stopped) ...

  • Fujitsu M10-4S - page 73

    Physical partition (stopped) BB#0 Hot XBBOX Cold BB#1 Hot Physical partition (stopped) BB#3 Hot BB#4 Hot Physical partition (stopped) BB#2 Hot Physical partition (stopped) BB#5 Hot Physical partition (stopped) BB#0 Hot PDU Cold PDU Hot BB#1 Hot XBBOX Hot Physical partition (stopped) BB#2 Hot BB#3 Hot BB#4 Hot Physical partition (stopped) Table 4-5 ...

  • Fujitsu M10-4S - page 74

    Table 4-5 Types of mai ntenance for SPARC M10-4 (c o ntinu e d ) Supported : Maintena nce can be perfor med / Unsupporte d: Mainten ance cann ot be performed FRU Active/hot Active/cold Inactive/hot Inactive/c old (*1) System stopped Refere nce Memory Unsupporte d Unsupported U nsupported S upported Suppor ted Chapte r 8 Power supply unit Supported ...

  • Fujitsu M10-4S - page 75

    Table 4-6 Types of m ainten ance for SPAR C M10-4S (c o nti nu e d) Supported: Main tenance can be per formed / Un supported: Main tenance cann ot be perform ed FRU Acti ve/ hot A ctiv e/col d Inact ive/ hot Inactive/ cold (*1) System s topped R eference Operation pane l Unsuppor ted Supported (*2) Unsupported S upported Supp orted Chapter 15 *1: F ...

  • Fujitsu M10-4S - page 76

    Table 4-8 Types of maint enance for cabl es and dedi cated pow er distri bution unit (c o ntin u e d ) Supported : Maintena nce can be perfor med / Unsupporte d: Mainten ance cann ot be performed FRU Active/hot Active/cold Inactive/hot Inactive/cold System stopped Refer ence XSCF BB cont rol cable Supported (*1) Supported S upported Supp orted Supp ...

  • Fujitsu M10-4S - page 77

    Caution - Do n ot operate a tar get Field Replaceable Unit (F RU) while OpenBo ot PROM is runnin g (the ok prompt i s displayed). After p owering off the phy sical partit ion or starting Oracle Solari s, operate th e target FRU. Chapter 5 Understanding the Preparations for Enabling Maintenance This chapt er describe s the preparat ions that must be ...

  • Fujitsu M10-4S - page 78

    XSCF> replacefru ---------- ------------ ------------ ------------ ------------ ------------ -------- Maintenanc e/Replacemen t Menu Please select a ty pe of model which has FR U to be replaced. 1. BB (4s Buil ding Block Model) 2. XBBOX (XB-BOX Model) ---------- ------------ ------------ ------------ ------------ ------------ -------- Select [1, ...

  • Fujitsu M10-4S - page 79

    1. BB itself 2. FAN (Fa n Unit) 3. PSU (Po wer Supply U nit) ----------- ------------ ------------ ------------ ------------ ------------ ------- Select [1-3|c: cancel] : 1 ----------- ------------ ------------ ------------ ------------ ------------ ------- Maintenance /Replacement Me nu Please select a FR U to be replaced. No. FRU Status --- ----- ...

  • Fujitsu M10-4S - page 80

    Note - W hen there is no free space on a physical partition or when all the resources are assigned to the co ntrol dom ain, DR can not be applied t o the physical part ition. XSCF> switchscf -t Standby The XSCF uni t switch bet ween the Mas ter and Stan dby states. Continue? [y|n ] : y XSCF> showpparstatus -p 0 PPAR-ID PPAR Status 00 Running ...

  • Fujitsu M10-4S - page 81

    # ldm list-domain NAME STATE FLAGS CONS VCPU MEMORY UTIL UPTIME primary active -n-cv- UART 14 8G 64% 2h 54m guest0 active -n---- 50 00 16 8G 42% 2h 54m guest1 active -n---- 50 01 16 8G 11% 2h 54m domain01 a ctive -n---- 5002 16 8G 7.3% 2h 54m # ldm list-devices -a CORE ID %FREE CPU SET 00( 0 , 1 ) 40( 8 , 9 ) 8 0 (16, 17 ) ----------------------- - ...

  • Fujitsu M10-4S - page 82

    # ldm list-io NAME TYPE BUS DOMAIN STATUS ---- ---- --- ------ ------ PCIE0 BUS PCIE0 primary IOV PCIE1 BUS PCIE1 primary IOV PCIE2 BUS PCIE2 primary IOV PCIE3 BUS PCIE3 primary IOV PCIE8 BUS PCIE8 domain01 IOV PCIE9 BUS PCIE9 domain01 IOV PCIE10 BUS PCIE10 domain01 IOV PCIE11 BUS PCIE11 domain01 IOV /BB0/CMUL/ NET0 PCIE PCIE0 primary OCC /BB0/CMUL ...

  • Fujitsu M10-4S - page 83

    PCIE1 BUS PCIE1 primar y IOV PCIE2 BUS PCIE2 primar y IOV PCIE3 BUS PCIE3 primar y IOV PCIE8 BUS PCIE8 PCIE9 BUS PCIE9 PCIE10 BUS PCIE10 PCIE11 BUS PCIE11 /BB0/CMUL/N ET0 PCIE PCIE0 primary OCC /BB0/CMUL/S ASHBA PCIE PCIE0 primary OCC /BB0/PCI0 PCIE PCIE1 primary EMP /BB0/PCI3 PCIE PCIE2 primary EMP /BB0/PCI4 PCIE PCIE2 primary EMP /BB0/PCI7 PCIE P ...

  • Fujitsu M10-4S - page 84

    XSCF> showboards -a PSB PPAR-ID(L SB) Assi gnment Pwr Con n Conf Test Fault ---- --------- --- ----------- - --- ---- ---- ----- -- -------- 0 0 - 0 0 0 ( 0 0 ) A s s i g n e dyyyP a s s e d N o r m a l 0 1 - 0 0 0 ( 0 1 ) A s s i g n e dnnnP a s s e d D e g r a d e d 0 2 - 0 0 0 ( 0 2 ) A s s i g n e dyyyP a s s e d N o r m a l 0 3 - 0 0 0 ( 0 ...

  • Fujitsu M10-4S - page 85

    XSCF> showdomainstatus -p 0 Logical Domai n Name Status primary Solaris running 4S-159-D0- G0 Solaris running 4S-159-D0- G1 Solaris running 4S-159-D0- G2 Solaris running XSCF> showboards -a PSB PPAR-ID(LSB) Assi gnment Pwr Conn Conf Test Fault ---- -------- ---- --------- -- ---- ---- ---- ---- --- -------- 0 0 - 0 0 0 ( 0 0 ) A s s i g n e d ...

  • Fujitsu M10-4S - page 86

    Note - Bef ore stoppi ng the sy stem, in form the users th at the syste m will be st opped. Note - W hen a physical partition is stopped by o perating the XSC F comm and or the operation panel, all the log ical dom ains on t he physical partiti on are stopped . Stop applications as requ ired. XSCF> showpparstatus -a PPAR-ID PPAR Status 00 Powere ...

  • Fujitsu M10-4S - page 87

    Note - Fo r a building bl ock config uration , switch the mode sw itches of the master ch assis and those cha ssis whos e XSCFs are in the standby state. XSCF> poweroff -a PPAR-IDs to powe r off:00,0 1 Continue? [y| n] : y 00 : Powering off 01 : Powering off Note - Fo r a building block co nfigur ation, check the PO WER LEDs on all the chassis t ...

  • Fujitsu M10-4S - page 88

    Note - F or a build ing block c onfigur ation, press the po wer switch on the m aster chassis. The power switches of th e other chassis are disab led. Note - F or a b uilding block con figurati on, check t he POW ER LE Ds on all t he chassis th at make up the system. 3. Check t hat the P OWER LED on the ope rat ion panel is of f. 5.5 Accessing Comp ...

  • Fujitsu M10-4S - page 89

    Figure 5-1 Locations of screws holdin g the cable support 2. Lower the cable sup port. 5.5.2 Removing the power cord When removing th e power cord of the SP ARC M10-4S or the crossba r box to perform maintenanc e work on a component, do so only af ter removing t he cable clamp f rom the power cord . 1. Release the latch (A in the figure) of the cab ...

  • Fujitsu M10-4S - page 90

    A A Figure 5-2 Releas ing the cable clamp (SPARC M10-4/M10-4 S) Figure 5-3 Releas ing the cable clamp (cross bar box) 2. Remove the power cord of the SPARC M10-4S from the PSU ba ckplane unit, or remo ve the power co rd of the cr ossbar box f rom the power supply u nit. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ Decemb ...

  • Fujitsu M10-4S - page 91

    Figure 5-4 Removing t he power cord (SPA RC M10-4/M10-4S) Figure 5-5 Removing the po wer cord (cr ossbar bo x) 5.5.3 Removing the front cover When performing main tenance on a componen t from the front of a SPARC M10-4S or crossbar box chass is, remove t he front cover bef ore start ing the work. 1. Release the right and left slide locks of th e fr ...

  • Fujitsu M10-4S - page 92

    Figure 5-6 Releas ing the sl ide locks of t he front cover (S PARC M10-4/M10-4S) Figure 5-7 Releas ing the sl ide locks of t he front cover ( crossbar box) 2. Lift the front cove r upw ards to remove it. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 68 ...

  • Fujitsu M10-4S - page 93

    Please execute t he following step s: 1) Confirm the XSC F STANDBY LED of BB#0 is no t lit. 2) Turn off t he breaker o f BB#0. 3) Remove BB#0. 4) Execute eithe r the following: 4-1) After the exch anged device is con nected with the sys tem, turn on the breaker o f BB#0, and please sel ect 'finish'. 4-2) If you want to susp end the mainte ...

  • Fujitsu M10-4S - page 94

    Waiting for BB# 0 to enter install sta te. [This operati on may take up to 20 minut e(s)] (progress sca le reported in seco nds) 0..... 30.. done Waiting for BB# 0 to enter ready state . [This operati on may take up to 45 minut e(s)] (progress sca le reported in seco nds) 0..... 30..... 60..... done Do you want to start to di agnose BB#0?[s: start| ...

  • Fujitsu M10-4S - page 95

    ----------- ------------ ------------ ------------ ------------ ------------ ------- Maintenance /Replacement Me nu Please select a ty pe of model which has FR U to be replaced. 1. BB (4s Build ing Block Model) 2. XBBOX (XB-BOX Model) ----------- ------------ ------------ ------------ ------------ ------------ ------- Select [1,2|c: cancel] : c Not ...

  • Fujitsu M10-4S - page 96

    XSCF> showresult 0 XSCF> showboards -a PSB PPAR-ID(L SB) Assi gnment Pwr Con n Conf Test Fault ---- --------- --- ----------- - --- ---- ---- ----- -- -------- 0 0 - 0 0 0 ( 0 0 ) A s s i g n e dyyyP a s s e d N o r m a l 0 1 - 0 0 0 ( 0 1 ) A s s i g n e dyyyP a s s e d N o r m a l # ldm add-io PCIE8 domain01 # ldm add-io PCIE9 domain01 # ld ...

  • Fujitsu M10-4S - page 97

    XSCF> showstatus XSCF> showhardcon f SPARC M10-4S; + Serial:20812 35006; Operator _Panel_Switc h:Locked; + System_Power :Off; System_Ph ase:Cabinet Po wer Off; Partition#0 PP AR_Status:Po wered Off; BB#00 Status:N ormal; Role:Mas ter; Ver:2047h ; Serial:208123 5006; + FRU-Part-Nu mber:CA07361 -D202 A1 ; + Power_Suppl y_System: ; + Memory_Size ...

  • Fujitsu M10-4S - page 98

    XSCF> poweron -p 0 Note - F or a build ing block c onfigur ation, check t he XSCF ST ANDBY L EDs of all the chassis constitut ing the system. Note - F or a build ing block c onfigur ation, switch t he mode switches of the m aster chassis and those chassis wh ose XSCFs are in t he standby st ate. XSCF> showstatus XSCF> showhardconf SPARC M1 ...

  • Fujitsu M10-4S - page 99

    ----------- ------------ - Ommitted ------- ------------ ----- PCI#0 Status: Normal; Name_P roperty:pci; + Vendor-ID:10 8e; Device-ID: 9020; + Subsystem_Ve ndor-ID:0000 ; Subsystem-ID :0000; + Model:; + Connection:7 001; PCIBOX#7001 ; Status:Normal ; Ver:1110h; Ser ial:21212370 01; + FRU-Part-Num ber:; IOB Status:Nor mal; Serial:PP1 23403JE ; + FRU ...

  • Fujitsu M10-4S - page 100

    Note - F or a build ing block c onfigur ation, press the po wer switch on the m aster chassis. The power switches of th e other chassis are disab led. than 4 seconds). For details, see " 2.2.2 C ontrol function o f the oper ation panel ." 6.5 Restoring the Chassis This section describes o perations req uired to restore the ch assis. 6.5.1 ...

  • Fujitsu M10-4S - page 101

    A Figure 6-2 Installing the power cord (cro ssbar box) 2. Clip the cable clamp aroun d the pow er cord and then fix th e cable clamp. The cable clam p is firmly fixed by lo cking the latch (A in th e figure) and then pushing the cab le clamp towa rds the front of the chassis . Figure 6-3 Lockin g the cable clamp (SPARC M10-4/M10-4 S) Chapter 6 Unde ...

  • Fujitsu M10-4S - page 102

    A Figure 6-4 Locking th e cable cla mp (cro ssbar bo x) 6.5.2 Fixing the cable support After perfor ming mainte nance on a co mponen t at the rear of the SP ARC M10- 4/M10- 4S, lift the cable support a nd fix it in place. 1. Lift the cabl e suppor t and lock it i n place by pushi ng the upper a nd lower screw fittings tow ards the back (direction o ...

  • Fujitsu M10-4S - page 103

    Note - Check that the cabl e support i s firmly attac hed and fixed. Figure 6-5 Lockin g the cable s upport 2. Tighten the right and left screw s to fix the cable supp ort. 6.5.3 Installin g the front cover If the fron t cover of the SPAR C M10-4S or the crossbar box was remov ed to perform maintenanc e, insta ll it af ter insta lling the compone n ...

  • Fujitsu M10-4S - page 104

    the bottom front of the chassis. Figure 6-6 Instal ling the front cover (SPARC M10-4/M10-4S) Figure 6-7 Installing the fr ont cover (cr ossbar b ox) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 80 ...

  • Fujitsu M10-4S - page 105

    Note - Check that the front co ver is firmly a ttached and fix ed. Chapter 6 Understanding the Preparations for Restoring the System 81 ...

  • Fujitsu M10-4S - page 106

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 82 ...

  • Fujitsu M10-4S - page 107

    Chapter 7 Maintaining the CPU Memory Units This chapt er desc ribes the p rocedure for mainta ining the CPU memory uni t mounted on the SPARC M10-4/M10-4 S. The CPU memory unit lo wer can only be repla ced. The CPU memory unit up per can be replaced, expanded , and red uced. ■ Configuration of the CPU Memory Units ■ Before Ma intaining a CPU Me ...

  • Fujitsu M10-4S - page 108

    (1) (2) Location numbe r Component 1 CPU me mory un it lower (CMU U) 2 CPU me mory un it upper (CMU L) Figure 7-1 Location of CPU memory unit There are t wo types of CPU memory unit s: FRAME-A and FRAME-B. The type of a CPU memory unit can be det ermined from th e indicat ion on the label ( A in the figure). I f a CPU memory unit does not hav e the ...

  • Fujitsu M10-4S - page 109

    A Note - Read an d underst and the instr uctions in this ch apter before startin g the main tenance work. Also se e the content s of " Chapter 1 Before St arting M aintenance W ork ." Figure 7-2 Type of CPU memory unit 7.2 Before Maintaining a CPU Memory Unit This se ction des cribes th e types and the flow of mainte nance of the CPU memo ...

  • Fujitsu M10-4S - page 110

    Table 7-1 Type of main tenance fo r CPU memory unit Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) S ystem stoppe d Single-chassis configu ration Unsuppor ted Unsupported U nsupported S upported Supported Building block c onfiguration Unsuppor ted Supported (*2 ) Unsupported Su pported Supported *1: For a single- chassis co nf ...

  • Fujitsu M10-4S - page 111

    7.2.3 Precautions for replacement Note the fo llowing point s when you replac e a CPU memory unit: ■ Do not replac e a CPU memory unit at the same t ime as the PSU ba ckplane unit . If you replace bot h a CPU memory unit and the PSU backp lane unit at the same time, th e system w ill fail t o operate normally . Replac e the CPU memory unit or PSU ...

  • Fujitsu M10-4S - page 112

    Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. A root com plex consists of an I /O controller on a pro ces ...

  • Fujitsu M10-4S - page 113

    Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Product Notes . Note - Active/cold m aintenan ce can be performed on ly for a build ing block con figur ation. XSCF> showlogs error XSCF> replac ...

  • Fujitsu M10-4S - page 114

    XSCF> showlogs error Note - When you add or remove CPU memory units, confirm that no error has occur red. XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Note - W hen the C PU memor y unit lower is repl a ...

  • Fujitsu M10-4S - page 115

    XSCF> dumpconfig XSCF> showlogs error Note - When y ou add or remo ve CPU memor y units, confirm th at no error has occurred. XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. If ...

  • Fujitsu M10-4S - page 116

    Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, individu al components or th e overall sys tem may be damaged. For d etails , see " 1.5 Notes Regarding Static Electricity ." Note - Re cord the positio ns of the cables be fore remo ...

  • Fujitsu M10-4S - page 117

    A c. Remove the screw s ecuring the cable holder (A in the figure) that is fixed to the supporting column on the rear of the rack, and then install the cable holder by rotating it 180 degrees. Figure 7-4 Cable hold er screw d. Use the hook-and-loop fastener to fix the crossbar cables to the cable holder. Figure 7-5 Fixing c rossbar cables Procedure ...

  • Fujitsu M10-4S - page 118

    Note - Re cord the positio ns of the cables be fore remov ing the m to ens ure that the y are reinstalled corre ctly. A b. Remove the hook-and-loop fastener of the cable support (A in the fi gure) to which the crossbar cables are fixed. Figure 7-6 Hook-and-loop fast ener of the cable support c. Use the hook-and-loop fastener to fix the crossbar cab ...

  • Fujitsu M10-4S - page 119

    Note - Record t he positions o f the cables before rem oving the m to ensure th at they are reinstalled corre ctly. Note - Mak e a note of t he positions of t he PCIe card cassettes bef ore remov ing them to e nsure that they are reinst alled correctly. 3. Remove all the cables connected to the external inter face on the rear of the chassis. The ca ...

  • Fujitsu M10-4S - page 120

    Note - T o expand or redu ce a CPU mem ory unit u pper, it is first necessary to rem ove the CPU mem ory un it lower. 7.4.2 Removing the CP U memory unit lower This se ction des cribes t he procedure f or removing a CPU memory unit lower. 1. Loosen the screw s securing the levers o f the CPU memory unit low er (rear left side) and then lower the ri ...

  • Fujitsu M10-4S - page 121

    Note - Place the remov ed CPU memory unit lower on a grounded an tistati c ESD mat. Note - Be careful n ot to dam age the righ t and left levers when placin g the CPU me mory u nit on the ESD mat. Figure 7-10 Pulling out CPU memory unit lower 3. Remov e the CPU m emory un it l ower while suppo rti ng it f rom bel ow with one hand. Figure 7-11 Remov ...

  • Fujitsu M10-4S - page 122

    Note - M ount the mem ory in th e same position as it was m ounted in the re moved CPU memory unit lower. Note - This work should all be perfo rmed from the rear of th e rack. Note - P lace the removed C PU memo ry unit lower o n a groun ded antistatic ES D mat. 5. Remove the memory modules from the CPU memory unit lower and install them in the new ...

  • Fujitsu M10-4S - page 123

    Figure 7-13 Removing ri ght-side guide 4. Unlock (push) the left-side guide ( when viewed from the re ar) and remove it by slidin g it in the dire ction of th e arro w. Figure 7-14 Removing l eft-s ide guide 5. Remove the two PCIe cables (A in the figure) on the right side that conne ct Chapter 7 Maintaining the CPU Memory Uni ts 99 ...

  • Fujitsu M10-4S - page 124

    A the CPU me mory units upper and lo wer, from the CPU m emory unit upper. In the case of a filler u nit, you can o mit this step because PC Ie cables are no t present. Figure 7-15 Removin g the right-side PC Ie cables 6. Remove the two PCIe c ables (A in the figure) on the left side that conn ect the CPU memor y unit s upper an d lower, f rom the ...

  • Fujitsu M10-4S - page 125

    A Figure 7-16 Removing th e left-side cables 7. Of the two P CIe cables on the left side, also remove the rear one from th e CPU memory unit lower, as it is short. In the case of a filler unit, you ca n omit this step beca use PCIe cables ar e not present . Chapter 7 Maintaining the CPU Memory Units 101 ...

  • Fujitsu M10-4S - page 126

    Figure 7-17 Removin g the PCIe cable fr om the left side rear Perform the fol lowing work from the rear s ide of the chassis. Figure 7-18 shows t he standing po sition (A in the figure ) of a field engineer. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 102 ...

  • Fujitsu M10-4S - page 127

    A Figure 7-18 Standing position o f a field engineer 8. Raise the levers (A in the figure) on the right and left sides to release the CP U memory unit upper. Chapter 7 Maintaining the CPU Memory Units 103 ...

  • Fujitsu M10-4S - page 128

    A A Note - P lace the removed C PU mem ory unit upper on a gr ounded an tistatic ESD m at. Figure 7-19 Positions o f right and left levers 9. While holding the lev ers, slightly l ift the CPU memory unit upper. 10. Lift the CPU memory unit upw ards and then remove it carefully. Figure 7-20 Removing CPU memory unit uppe r Fujitsu M10-4/Fujitsu M10-4 ...

  • Fujitsu M10-4S - page 129

    Note - Mount the memory in the same posi tion as it was mount ed in the remove d CPU memor y unit upper. Note - A part of the proc edure vari es dependi ng on the CPU memory unit type. To determin e the CPU memory unit type, c heck the labe l in Figure 7-2 . 11. Remove the memory mod ules from the removed CPU memory u nit upper and then install the ...

  • Fujitsu M10-4S - page 130

    A 2. Loosen the tw o screws holding the upper rear side of the CPU memory unit lower. Then, remove the rear cov er (A in the figure) by pulling it in the direction of the arrow. Figure 7-22 Removin g the rear co ver 3. Remove the XSCF board. - For the SPARC M10- 4 with a FRAME-A C PU memory unit Remove the t hree scre ws fixing t he XSCF board (A i ...

  • Fujitsu M10-4S - page 131

    A B C Figure 7-23 Releasing a co nnected XSCF boar d (for SP ARC M1 0-4 with a FRAME-A CPU memory unit) - For the SPARC M10-4S w ith a FRAME-A CPU me mory unit Remove the fo ur screws fixin g the XSCF bo ard (A in the figu re). Then, lift the right sid e of the XSCF board t o release the connector . Chapter 7 Maintaining the CPU Memory Units 107 ...

  • Fujitsu M10-4S - page 132

    A Note - P lace the removed XS CF board on a gr ounded an tistatic ESD m at. Figure 7-24 Releas ing a connec ted XSCF b oard (for th e SPARC M10-4S with a FRAME-A CPU memory unit) 4. Pull ou t the XSC F board di agonal ly to the ri ght (a rrow). Figure 7-25 Pulling o ut an XSCF board (fo r the SPARC M10- 4 with a FRAME-A CPU memory unit) Fujitsu M1 ...

  • Fujitsu M10-4S - page 133

    Figure 7-26 Pulling out an XS CF board (for the SPARC M10-4S with a FRAME-A CPU memory unit) 5. Remove the screw fixing the X SCF mount. - For the SPARC M10-4/M1 0-4S with a FRAME-A CP U memory unit Remove the one s crew fix ing the XSCF mount (A in the figure) . Chapter 7 Maintaining the CPU Memory Units 109 ...

  • Fujitsu M10-4S - page 134

    A Figure 7-27 Screw for the XS CF mou nt (for the SPAR C M10-4 with a FRAM E-A CPU memory unit) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 110 ...

  • Fujitsu M10-4S - page 135

    A Figure 7-28 Screw f or the XSCF mount (for the S PARC M10-4S with a FRAME -A CPU memory unit) - For the SPARC M10-4S w ith a FRAME-B CPU me mory unit Remove the two scre ws fixing the XSCF mount (A in the figure) . Chapter 7 Maintaining the CPU Memory Units 111 ...

  • Fujitsu M10-4S - page 136

    A Figure 7-29 Screw for the X SCF mount (for the SPARC M10-4S with a FRAME-B CPU memory unit) 6. Remove the XSCF mount. - For the SPARC M10-4/M 10-4S with a FRAME- A CPU memory unit Raise th e protruding l eft lev er (B in the f igure) of the XSCF mount (A in the figure) by about 2 mm (0.1 in .) with your fing ers, and s lide it ab out 8 mm (0.4 in ...

  • Fujitsu M10-4S - page 137

    A B C D D Figure 7-30 Removing t he XSCF mount (for the SPA RC M10-4 with a FRAME-A CPU memory unit) Chapter 7 Maintaining the CPU Memory Units 113 ...

  • Fujitsu M10-4S - page 138

    A B B C D Figure 7-31 Removin g the XSCF mo unt (for the S PARC M1 0-4S with a FRA ME-A CPU memory unit) - For the SPARC M10-4S with a FRAME-B CPU memory un it Remove the XSCF mount (A in the figure) upward (B in t he figure). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 114 ...

  • Fujitsu M10-4S - page 139

    AB Figure 7-32 Removing t he XSCF mount (for the SPA RC M10-4S with a FRAME- B CPU memory unit) 7. Remove the screw fixing the CPU memory unit board. - For the SPARC M10-4/M1 0-4S with a FRAME-A CP U memory unit Remove the on e black screw (A i n the figure) fixin g the center part of the radiator on the f ront and the four s crews fix ing the CPU ...

  • Fujitsu M10-4S - page 140

    B A Figure 7-33 Screws on th e CPU memory unit board (for the SPA RC M10-4/M10- 4S wit h a FRAME-A CPU m emory unit) - For SPARC M10-4S with a FRAME-B CPU memory unit Remove the o ne black screw ( A in the figure) fixing th e center part of the radiator on the fron t and the si x screws f ixing the CPU memory uni t board (B in the figure). Fujitsu ...

  • Fujitsu M10-4S - page 141

    A B Note - Be careful not to tou ch or catch your clothes or wrist strap on a conne ctor pin located o nt h eb a c ks i d eo ft h eC P Um e m o r yu n i tb o a r d . Note - Ha rd objects such as a mach ine tools sho uld not co me in contact wit h the connect or located on the b ack side of the C PU memor y unit b oard. Figure 7-34 Screw s on the CP ...

  • Fujitsu M10-4S - page 142

    A A Right Left B B Right Left Figure 7-35 Finger position when releas ing the connection of the connector (surface) Figure 7-36 Finger po sition when releasin g the connectio n of the connecto r (rear surface) 9. Supporting the frame with your thumb (A in the figure), disconn ect the connection of the con nector by pushing u p the left and right si ...

  • Fujitsu M10-4S - page 143

    A B A B Note - Place the remov ed CPU memory unit board on a grounded anti static ESD ma t. same time wit h the fi ngers tha t are inse rted unde r the CPU memor y unit boa rd (B in the figure). Figure 7-37 How to dis connect th e connecti on of the connec tor 10. Place your thumb on the conn ector unit located at the center of the right and lef t ...

  • Fujitsu M10-4S - page 144

    Right Left A A B B Right Left Figure 7-38 Finger po sition when hol ding the boar d (surface) Figure 7-39 Finger po sition when hol ding the boar d (rear surf ace) 11. Lift the CPU m emory unit board in the horizontal position and remove i t from the frame. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 120 ...

  • Fujitsu M10-4S - page 145

    Figure 7-40 Removing t he CPU memory unit board 12. Remove the sheet (A in the figure). You can expand t he CPU memory unit upper by pe rforming the above procedure . You do not have to perform s tep 10. Chapter 7 Maintaining the CPU Memory Units 121 ...

  • Fujitsu M10-4S - page 146

    A Note - D o not attem pt to remove a PC Ie cable in the wron g direction. If excessive f orce is used to remove a PCIe cab le, it may be da maged. Figure 7-41 Removin g the sheet 13. Remove the three PCIe cables. The direction in wh ich the PCIe c ables are remo ved varies depending on the type of the CPU memory unit . - The conne ctors for the th ...

  • Fujitsu M10-4S - page 147

    Figure 7-42 Removing the P CIe cables (with the co nnectors for t he three PCIe cables fa cing the outside of the CPU memory unit ) - The connector for one PCIe cable facing the outside of the CPU memory unit and the other two facing the front of the CPU memory unit Chapter 7 Maintaining the CPU Memory Units 123 ...

  • Fujitsu M10-4S - page 148

    Note - When mounting a CPU memory unit , check the connect ors on both of the chassis and CPU memory unit beforehand to conf irm that no pin is bent and all the p i n sa r en e a t l y a r r a n g e di nl i n e s .I ft h e r ei sab e n tp i ni nac o n n e c t o r , m o u n t i n g a CPU memory unit may damage the chas sis or CPU memory unit. A lso, ...

  • Fujitsu M10-4S - page 149

    Note - When e xpandin g a CPU me mory u nit upper, first con nect the PCIe cable to th e CPU m e m o r y u n i tl o w e r .T h eP C I ec a b l e sa r ea t t a c h e da sa na c c e s s o r yo ft h eC P Um e m o r yu n i t upper. Note - Do n ot attempt to in stall a PCIe cable in the wr ong direct ion. If excessive force is used to install a PC Ie ca ...

  • Fujitsu M10-4S - page 150

    A unit and the other two facing the front of the CPU memory unit Figure 7-45 Installing the PC Ie cables (with the con nector for one PCIe c able facing the out side and the two facing t he front of the CPU memory unit) 2. Install the sheet (A in the figure). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 126 ...

  • Fujitsu M10-4S - page 151

    A Note - Do n ot tilt the CPU m emory un it board when insta lling it. The b oard m ay be dam aged by hitting the bac k side of the board aga inst a protru ding part or the fram e guide. Figure 7-46 Installing sheet 3. Hold the connector unit at the center of the CPU memory unit board and install it on the frame in the horizontal position. For how ...

  • Fujitsu M10-4S - page 152

    OK NO Figure 7-47 Correct posi tion of the CPU memory unit board Figure 7-48 Wrong posit ion of the CPU m emory unit board - For the SPARC M10-4/M10-4S w ith a FRAME-A CPU memory unit Install the frame so th at the bent tip of the fra me (C in the figure ) can be inserted into the space (B in the fig ure) between the end face o f the far side of th ...

  • Fujitsu M10-4S - page 153

    D E C B FG A threaded hole o f the frame can be seen (E in the figure ). c. Attach the connect or by pressin g down the con nector units (F a nd G in the figure) loca ted at t he cent er of the right and left sid es of the board at the same time. Figure 7-49 Installing the CPU memory unit board (for the SPARC M10-4/M10-4S with a FRAME-A CPU memory ...

  • Fujitsu M10-4S - page 154

    A B C D E Figure 7-50 Instal ling the CPU memory unit board ( for the SPARC M10-4S wi th a FRAME-B CPU memory unit) 4. Fix the CPU memory unit board with screw s. - For the SPARC M10-4/M 10-4S with a FRAME- A CPU memory unit Fix the CPU memory unit board w ith four screw s and the ce nter part of t he r a d i a t o r o nt h ef r o n tw i t ho n eb ...

  • Fujitsu M10-4S - page 155

    - For the SPARC M10-4S w ith a FRAME-B CPU me mory unit Fix the CPU memory unit board with six sc rews. 5. Install the XSCF mount and fix it with screws. - For the SPARC M10-4/M1 0-4S with a FRAME-A CP U memory unit Align the on e point on the l eft and t wo points on the ri ght of the XSCF mount with the frame g uides of the CPU memor y unit lower ...

  • Fujitsu M10-4S - page 156

    B A Figure 7-52 Installing the XSC F mou nt (for the SPAR C M10-4 S with a FRAME-B CPU memory unit) 6. Install the XSCF board. - For the SPARC M10- 4 with FRAME-A C PU memory unit Insert the XSCF bo ard into gu ides at the two location s (A in the figure) on th e mount (B in the f igure), and p ush the righ t lever of th e mount about 5 mm (0.2 in. ...

  • Fujitsu M10-4S - page 157

    A F B C E D Figure 7-53 Installing the XSCF board (fo r the SPARC M10-4 with a FRAME- A CPU memory unit) - For the SPARC M10-4S w ith FRAME-A CPU m emory unit Insert the XSCF b oard into the left gui de (A in the figure), and pr ess down the right con nector un it (B in the fig ure) to attach the co nnector. The n, fix it with two screws. Chapter 7 ...

  • Fujitsu M10-4S - page 158

    B A Figure 7-54 Instal ling the XSCF board (f or the SPARC M10-4S wi th a FRAME-A CPU memory unit) 7. Attach the rear cov er with two scre ws from the upper part of the rear side of the CPU memory unit lower. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 134 ...

  • Fujitsu M10-4S - page 159

    A Figure 7-55 Screws for rear c over 8. Install the eight screws at both ends of the XSCF cable connection port on the rear of the CPU memory unit lower. For the SPARC M10-4 wit h a FRAME-A CPU memory unit and th e SPARC M10-4S with a FRAME-B CPU memory unit, this s tep is not neces sary. Chapter 7 Maintaining the CPU Memory Units 135 ...

  • Fujitsu M10-4S - page 160

    Note - A part o f the procedure varies depen ding on t he CPU me mory un it type. To determine th e CPU mem ory un it type, check the labe l in Figur e 7-2 . Note - Confirm th at the lev ers on the left and right sides of the CPU memory unit upper are closed. Figure 7-56 Screws for b oth ends of the XSCF c able con nection ports (fo r the SPARC M10 ...

  • Fujitsu M10-4S - page 161

    A A A A B B B B Figure 7-57 Guid e positions of the CPU memory unit upper - When insta lli ng the fi lle r unit f or the CPU memory u nit uppe r Carefully install the filler unit for th e CPU memory unit upper by setting the two guides (A in the figure) of the filler unit in the groove (B in the figure) of the CPU memory unit lower. Chapter 7 Maint ...

  • Fujitsu M10-4S - page 162

    A A B B Figure 7-58 Guide positions of the filler unit for the CPU memory unit upper 2. Install the CPU memory unit upper by holding it down from the center where the label "PUSH" is applied, and th en push it into place. Firmly push the un it so that t here is no spa ce betwe en the CPU memory unit upper and the frame of the CPU memory u ...

  • Fujitsu M10-4S - page 163

    Figure 7-59 Posit ion where the CPU memory unit upper is pushed 3. Connect, to the CPU memory unit upper, the four right and left PCIe cables connecting the CPU memory units upp er and lower. While pressing the pi n that locks the PC Ie cable, insert it vertically. Chapter 7 Maintaining the CPU Memory Units 139 ...

  • Fujitsu M10-4S - page 164

    Note - Of the two PCIe cable s on the right side, also instal l the one (short) cable on the rear of the CPU me mory u nit lower. Note - Be care ful not to d amage the PCIe cab le when installin g the left- and r ight-side g uides. 4. Install the ri ght- and left-side guides. Each guide ha s four clips. Install the g uides using the clips, an d sli ...

  • Fujitsu M10-4S - page 165

    Figure 7-61 Positions of the clips o n the left- and right-side g uides (for the SPARC M10-4S with a FRAME-B CPU memory unit) Chapter 7 Maintaining the CPU Memory Units 141 ...

  • Fujitsu M10-4S - page 166

    Figure 7-62 CPU memory unit upper and pos itions of t he clips on t he side guid e (for the S PARC M10-4/M10-4S with a FRAME-A CPU memory unit) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 142 ...

  • Fujitsu M10-4S - page 167

    Figure 7-63 CPU memory unit uppe r and positi ons of the clip s on the sid e guide (for the SPAR C M10-4S with a FRAME-B CPU memory unit) Chapter 7 Maintaining the CPU Memory Units 143 ...

  • Fujitsu M10-4S - page 168

    Figure 7-64 Filler unit of the CPU memory unit up per and positions of the clips on the sid e guide (for th e SPARC M10-4/M10-4S w ith a FRAME-A CPU memory unit) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 144 ...

  • Fujitsu M10-4S - page 169

    Figure 7-65 Filler unit of the CPU memory unit up per and positions of the clips on the side guide (for the S PARC M1 0-4S with a FRA ME-B CPU memory unit) 5. Install the top-side cover of the CPU memory unit. 6. Install the CPU memory unit lower in the chassis. For details, see " 7.5.3 Installing t he CPU memory unit lower ." Chapter 7 M ...

  • Fujitsu M10-4S - page 170

    Note - If t he CPU mem ory un it lower is inserted as far as it will g o, it may n ot be possible to lift the lever. Lift the lever j ust before the CP U memor y unit low er hits the rear and th en push it fully ho me. Note - Re install the PC Ie card cassettes in their orig inal positio ns by referrin g to the n otes that yo u made prior t o the s ...

  • Fujitsu M10-4S - page 171

    Note - Reinst all the cables in the cor rect positions by re ferring to th e notes you mad e before starting main tenance. Note - Con nect the crossb ar cables in their orig inal positio ns by referrin g to the no tes that you m ade before the start o f mainten ance. Note - Con nect the crossb ar cables in their orig inal positio ns by referrin g t ...

  • Fujitsu M10-4S - page 172

    Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . Note - Use the DR of the system board on a phys ical par tition for ac tive/col d maintenance . For the XC P and Oracle VM Serve r for SPAR C/SRU versio ns that correspon d to the DR, see the latest Prod uct Note s . Not ...

  • Fujitsu M10-4S - page 173

    Note - See the pro cedure for system -stopped m aintenan ce for inactive/cold ma intenance in a single-cha ssis confi guration. Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. XSCF> diagxbu -y -b 00 -t 01 For details, s ...

  • Fujitsu M10-4S - page 174

    XSCF> showlogs error XSCF> showstatus XSCF> showhardconf Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. For details, see " 3.3.5 C hecking lo g infor mation ." 5. Switch the m ode switches of the m ast ...

  • Fujitsu M10-4S - page 175

    XSCF> diagxbu -y -b 00 -t 01 XSCF> showlogs error XSCF> setpparparam -p 0 -s bootscript "set env auto-boot? false" XSCF> setpparmode -p 0 -m guestboot=off XSCF> setpparparam -p 0 -s bootscript "set env auto-boot? true" The example belo w specifies the following: 00: BB-ID of t he chassis to start the diag nosis 01 ...

  • Fujitsu M10-4S - page 176

    XSCF> showstatus XSCF> showhardconf Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. Switch the mode switche s of BB-ID#00 an d #01 to Locked mo de. - For a building block configuration (with crossbar box) Switch the ...

  • Fujitsu M10-4S - page 177

    XSCF> diagxbu -y -b 00 -t 01 Note - If y ou cann ot log in wit h an XSCF user acco unt and passwo rd, use the defau lt user account o f the XS CF to l og in t o the XSC F. For details, see "6.3 Lo ggin g In to t he XSCF " in the Fujitsu M10/SPAR C M10 Systems I nstallatio n Guide . XSCF> restoreconfig XSCF> showlogs error (You ca ...

  • Fujitsu M10-4S - page 178

    XSCF> testsb -v -y -s 00 -0 XSCF> showstatus XSCF> showhardconf XSCF> showdate XSCF> setdate -s 102016592013.00 Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. 7. Execute the show status command to confirm ...

  • Fujitsu M10-4S - page 179

    XSCF> diagxbu -y -b 00 -t 01 Note - If y ou cann ot log in wit h an XSCF user acco unt and passwo rd, use the defau lt user account o f the XS CF to l og in t o the XSC F. For details, see "6.3 Resett ing th e System" in th e Fujitsu M10/SPARC M10 Syste ms Installati on Guide . XSCF> restoreconfig 2. Return to the operation of the X ...

  • Fujitsu M10-4S - page 180

    XSCF> showlogs error XSCF> testsb -v -y -s 00 -0 XSCF> setpparparam -p 0 -s bootscript "setenv auto-boot? fals e" XSCF> setpparmode -p 0 - m guestboot=off XSCF> setpparmode -p 0 - m guestboot=on normally. For details, see " 3.3.5 C hecking lo g infor mation ." 6. Execute the testsb command to co nfirm that the CPU ...

  • Fujitsu M10-4S - page 181

    XSCF> showstatus XSCF> showhardconf XSCF> showdate XSCF> setdate -s 102016592013.00 If there is n o pro blem, nothin g is displayed. 14. Execute the sh owhard conf command to confirm the hardware configuration and the status of each CPU memory unit. Confir m that n o asterisk ( *) is displayed in front of each co mponent. 15. Execute th ...

  • Fujitsu M10-4S - page 182

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 158 ...

  • Fujitsu M10-4S - page 183

    Chapter 8 Maintaining the Memory This chapt er desc ribes the p rocedure for mainta ining the memory mount ed on the SPARC M10-4/M10-4S. Memory can be r eplaced, expanded, a nd reduced. ■ Memory Configurat ion ■ Memory Configuration Rul es ■ Before Ma intaining M emory ■ Enabling the Remova l of Memory ■ Removing Memory ■ Installing Mem ...

  • Fujitsu M10-4S - page 184

    CPU#0 CMUL Front CPU#1 (2) (1) (4) (3) (10) (9) (12) (1 1) (22) (21) (24) (23) (30) (29) (32) (31) (15) (16) (13) (14) (7) (8) (5) (6) (27) (28) (25) (26) (19) (20) (17) (18) Location numbe r Component Group 1 Memory (CMUL/MEM#00A) A 2 Memory (CMUL/MEM#00B) B 3 Memory (CMUL/MEM#01A) A 4 Memory (CMUL/MEM#01B) B 5 Memory (CMUL/MEM#02A) A 6 Memory (CM ...

  • Fujitsu M10-4S - page 185

    Location n umber Com ponent Group 7 Memory (CMUL/MEM#03A) A 8 Memory (CMUL/MEM#03B) B 9 Memory (CMUL/MEM#04A) A 10 Memory (CMUL/MEM#04B) B 11 Memory (CMUL/MEM#05A) A 12 Memory (CMUL/MEM#05B) B 13 Memory (CMUL/MEM#06A) A 14 Memory (CMUL/MEM#06B) B 15 Memory (CMUL/MEM#07A) A 16 Memory (CMUL/MEM#07B) B 17 Memory (CMUL/MEM#10A) A 18 Memory (CMUL/MEM#10 ...

  • Fujitsu M10-4S - page 186

    CPU#0 CMUU CPU#1 (34) (33) (36) (35) (42) (41) (44) (43) (54) (53) (56) (55) (62) (61) (64) (63) (47) (48) (45) (46) (39) (40) (37) (38) (59) (60) (57) (58) (51) (52) (49) (50) Front Location numbe r Component Gro up 33 Memor y (CMUU/ MEM#00A ) A 34 Memor y (CMUU/ MEM#00B ) B 35 Memor y (CMUU/ MEM#01A ) A 36 Memor y (CMUU/ MEM#01B ) B 37 Memor y (C ...

  • Fujitsu M10-4S - page 187

    Location n umber Componen t Group 40 Memory ( CMUU/MEM#03B) B 41 Memory ( CMUU/MEM#04A) A 42 Memory ( CMUU/MEM#04B) B 43 Memory ( CMUU/MEM#05A) A 44 Memory ( CMUU/MEM#05B) B 45 Memory ( CMUU/MEM#06A) A 46 Memory ( CMUU/MEM#06B) B 47 Memory ( CMUU/MEM#07A) A 48 Memory ( CMUU/MEM#07B) B 49 Memory ( CMUU/MEM#10A) A 50 Memory ( CMUU/MEM#10B) B 51 Memor ...

  • Fujitsu M10-4S - page 188

    8.2.1 Memory mounting rules Install the memory in accordanc e with the fo llowing rules : ■ Mount memory in un its of e ight modul es. ■ Within a unit of e ight modules , all the memory modules must be of t he same capacity and rank. ■ For memory for one CPU, use only R-DIMM (R egiste red DIMM: 8 GB/ 16 GB/32 GB) or o nly LR-DI MM (Loa d Redu ...

  • Fujitsu M10-4S - page 189

    g c h d e a f b CPU#0 MEM#00B MEM#00A MEM#01B MEM#01A MEM#04B MEM#04A MEM#05B MEM#05A MEM#07A MEM#07B MEM#06A MEM#06B MEM#03A MEM#03B MEM#02A MEM#02B CPU#1 MEM#12A MEM#13A MEM#16A MEM#17A MEM#12B MEM#13B MEM#16B MEM#17B MEM#15A MEM#14A MEM#1 1A MEM#10A MEM#15B MEM#14B MEM#1 1B MEM#10B CPU#0 CPU#1 MEM#00B MEM#00A MEM#01B MEM#01A MEM#04B MEM#04A MEM# ...

  • Fujitsu M10-4S - page 190

    Table 8-1 Memory mounting configura tions (CMUL only) Number of memo ry modules Mounted memor y 8a i n Figure 8-3 --- 16 a in Figure 8-3 bi n Figure 8-3 -- 24 a in Figure 8-3 bi n Figure 8-3 ei n Figur e 8-3 - 32 a in Figure 8-3 bi n Figure 8-3 ei n Figur e 8-3 fi n Figure 8-3 Table 8-2 Memory m ountin g patterns (C MUL and C MUU) Number of memory ...

  • Fujitsu M10-4S - page 191

    Table 8-3 Memory mounting configura tions (CMUL and expanded CMUU) Number of memory modules Mounted memor y 8a i n Figur e 8-3 - 16 a in Figur e 8-3 bi n Figur e 8-3 ------ 24 a in Figur e 8-3 bi n Figur e 8-3 ei n Figur e 8-3 ----- 32 a in Figur e 8-3 bi n Figur e 8-3 ei n Figur e 8-3 fi n Figure 8-3 ---- 40 a in Figur e 8-3 bi n Figur e 8-3 ei n ...

  • Fujitsu M10-4S - page 192

    + Code:ce8002 M393B5270DH0 -YH9 0000-85A8EF57; + Type:01; Size :4 GB; MEM#02A Status :Normal; + Code:ce8002 M393B5270DH0 -YH9 0000-85A8EF65; + Type:01; Size :4 GB; MEM#03A Status :Normal; + Code:ce8002 M393B5270DH0 -YH9 0000-85A8EE2C; + Type:01; Size :4 GB; MEM#00A Status:Normal; + Code:ce8002M393B5270DHO-YH9 0000-83AE9A65; + Type:04; Size:8 GB; Me ...

  • Fujitsu M10-4S - page 193

    Table 8-4 Types of m aintenan ce for mem ory (c o ntinu e d ) Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) S ystem stopped Build ing bloc k config uration Unsupported S upported (*2) Unsu pported Supporte d Supported *1: For a single-cha ssis configur ation, the inactive/ cold maintena nce procedure is the sa me as that for ...

  • Fujitsu M10-4S - page 194

    Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. Note - Use the DR of the system board on a phys ical par ti ...

  • Fujitsu M10-4S - page 195

    Note - When y ou add or remo ve CPU memor y units, confirm th at no error has occurred. XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. Note - In active/cold maint enance can be perfo ...

  • Fujitsu M10-4S - page 196

    XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . XSCF> showlogs error Note - When you add or remove CPU memory units, confirm that no error has occur red. Note - In the c ase of a dual power feed, m ake a ...

  • Fujitsu M10-4S - page 197

    Caution - Before you handle any compone nts, wea r a wrist strap to ground any static electricity. If you per form this pr ocedure witho ut a wrist strap, individ ual components or the ov erall sys tem may be damaged. For d etails , see " 1.5 Notes Regardin g Static Electricity ." Note - Place th e removed me mory on a gro unded stat ic-r ...

  • Fujitsu M10-4S - page 198

    Note - C onfirm th at the clip o f the mem ory slo t has retur ned to its origin al positio n. Figure 8-5 Removin g memory 8.6 Installi ng Memory This section describes the procedure f or installing a memory module. Perform expansion using the sa me procedure. 8.6.1 Installing memory 1. Place the memory modu le by aligni ng the no tched secti on w ...

  • Fujitsu M10-4S - page 199

    Note - See the pro cedure for system -stopped m aintenan ce for inactive/cold ma intenance in a single-cha ssis confi guration. Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Product Notes . Note - ...

  • Fujitsu M10-4S - page 200

    XSCF> diagxbu -y -b 00 - p 02 XSCF> showlogs error Note - In active/cold m aintenance can b e performed o nly for a b uilding b lock config urati on. See the procedure f or system -stopped main tenance for in active/cold m aintenance in a single-ch assis config uration . Note - In t he case of a dual power feed, co nnect the power cord s in t ...

  • Fujitsu M10-4S - page 201

    XSCF> diagxbu -y -b 00 -t 01 XSCF> showlogs error XSCF> showstatus XSCF> showhardconf For details, see " 6.1 Inc orpor ating an FR U into the System with the repl acefru Comman d ." 3. Execute the di agxbu comma nd to dia gnose the c rossba r cables . Diagnosis is pe rformed when the syst em board of the chassis conne cted wi ...

  • Fujitsu M10-4S - page 202

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. XSCF> testsb -a 8.7.3 System-stopped maintenance 1. Connect all the power co rds to the PSU bac kplane u nit of the cha ssis requiring maintenance. For details, see " ...

  • Fujitsu M10-4S - page 203

    Chapter 9 Maintaining the Crossbar Units This chapter descri bes the procedure fo r maint aining the cro ssbar units m ounted on a SPARC M10-4S. ■ Configuration of the Crossbar Uni ts ■ Before Ma intaining a Crossbar Unit ■ Enabling the Remova l of a Crossbar Uni t ■ Removing a Crossbar Unit ■ Installing a Cr ossbar U nit ■ Restoring t ...

  • Fujitsu M10-4S - page 204

    㩿㪈㪀 㩿㪉㪀 Location numbe r Component 1 Crossbar u nit (XBU#0) 2 Crossbar u nit (XBU#1) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 9-1 Location of crossbar units 9.2 Before Maintaining ...

  • Fujitsu M10-4S - page 205

    Table 9-1 Types of m ainten ance for the crossb ar unit Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Unsupported S upported (*) Uns upported Supp orted Supported *: It is necessa ry to use d ynamic re configurati on (DR) t o discon nect a cha ssis requiring maintenance from th e phys ...

  • Fujitsu M10-4S - page 206

    Note - Use the DR of the system board on a phys ical par tition for ac tive/col d maintenance . For the XC P and Oracle VM Serve r for SPAR C/SRU versio ns that correspon d to the DR, see the latest Prod uct Note s . XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power co ...

  • Fujitsu M10-4S - page 207

    XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. XSCF> showlogs error XSCF> replacefru For details, see " 3.3.5 C hecking log i nform ation ." 4 ...

  • Fujitsu M10-4S - page 208

    Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, individu al component ...

  • Fujitsu M10-4S - page 209

    Figure 9-2 Locat ion of scre ws secur ing crossbar un its 2. Open th e ej ect le v er s (A i n th e fi gu re) upwa rds a nd do wnwar ds, re spe ct iv e ly, and then pu ll t he crossba r uni t out o f the CPU memo ry uni t. Chapter 9 Maintaining the Crossbar Units 185 ...

  • Fujitsu M10-4S - page 210

    A Note - P lace the removed crossb ar unit o n a groun ded antistatic ES D mat. Note - When mounting a crossbar un it, ch eck the connectors on bot h of the chas sis and crossb ar unit befor ehand to con firm that no pin is bent and all the pin s are neatly arrange d in lines. If a crossba r unit is mou nted with a bent pin in a co nnector, the cha ...

  • Fujitsu M10-4S - page 211

    Note - Con nect the crossb ar cables in their orig inal positio ns by referrin g to the no tes that you m ade before the start o f mainten ance. Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Produ ...

  • Fujitsu M10-4S - page 212

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. XSCF> diagxbu -y -b 00 - p 02 XSCF> showlogs error Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o t ...

  • Fujitsu M10-4S - page 213

    XSCF> diagxbu -y -b 00 -t 01 XSCF> showlogs error XSCF> showstatus XSCF> showhardconf For details, see " 6.1 Inc orpor ating an FR U into the System with the repl acefru Comman d ." 3. Execute the di agxbu comma nd to dia gnose the c rossba r cables . Diagnosis is pe rformed when the syst em board of the chassis conne cted wi ...

  • Fujitsu M10-4S - page 214

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. XSCF> diagxbu -y -b 00 - t 01 XSCF> showlogs error 9.6.3 System-stopped maintenance 1. Connect all the power cords to the PSU backp lane unit. For details, see " ...

  • Fujitsu M10-4S - page 215

    Chapter 10 Maintaining the Power Supply Units This chapt er describes the p rocedure for mainta ining the power suppl y units mounted in the SPARC M10-4/M10-4S . ■ Configu ration of the Power Su pply Units ■ Before Ma intaining a Power Supply U nit ■ Enabling t he Removal of a Power Supp ly Unit ■ R e m o v i n gaP o w e rS u p p l yU n i t ...

  • Fujitsu M10-4S - page 216

    (1) (2) Location numbe r Component 1 Power sup ply unit (PSU #0) 2 Power sup ply unit (PSU #1) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 10-1 Location of powe r supply unit 10.2 Before Maintai ...

  • Fujitsu M10-4S - page 217

    Table 10-1 Types of ma intenan ce for the power supply un it Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) S ystem stopped Sing le-c hass is co nfig ura tio n Supporte d Unsupport ed Supporte d Supported Su pported Build ing bloc k config uration Supporte d (*2) Support ed (*3) Support ed Support ed Supporte d *1: For a singl ...

  • Fujitsu M10-4S - page 218

    Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. Note - Active/hot maintena nce is sup ported only for a re ...

  • Fujitsu M10-4S - page 219

    Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Product Notes . Note - Active/cold m aintenan ce can be performed on ly for a build ing block con figur ation. XSCF> showlogs error XSCF> replac ...

  • Fujitsu M10-4S - page 220

    XSCF> showlogs error XSCF> showpparstatus -a XSCF> replacefru XSCF> showlogs error 10.3.3 Inactive /Hot maintenance For a single-chassis configurati on 1. Open the rack do or. 2. Log in to the XSCF s hell . 3. Execute the sho wlogs command to identify the co mponent requiring maintenance. For details, see " 3.3.5 C hecking lo g inf ...

  • Fujitsu M10-4S - page 221

    XSCF> replacefru Note - In active/cold maint enance can be perform ed only for a buildin g block conf iguratio n. The inactive/c old main tenance proced ure for a single -chassis config uration is the s ame as that fo r stopping the system . XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean ...

  • Fujitsu M10-4S - page 222

    XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . 10.3.5 System-stopped maintenance 1. Open the rack do or. 2. Log in to the XSCF s hell . 3. Execute the sho wlogs command to identify t ...

  • Fujitsu M10-4S - page 223

    Caution - Before you handle any compone nts, wea r a wrist strap to ground any static electricity. If you per form this pr ocedure witho ut a wrist strap, individ ual components or the ov erall sys tem may be damaged. For d etails , see " 1.5 Notes Regardin g Static Electricity ." 10.4.1 Accessing a power supply unit 1. Remove the front c ...

  • Fujitsu M10-4S - page 224

    Note - P lace the removed power supply un it on a grounded ant istatic ESD mat. Note - D o not for cibly push the p ower supply un it into its slot. Usin g excessive force may damage the component or the chassi s. Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . 10.5 I ...

  • Fujitsu M10-4S - page 225

    XSCF> showstatus XSCF> showhardconf Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Product Notes . Note - Active/cold m aintenan ce can be performed on ly for a build ing block con figur atio ...

  • Fujitsu M10-4S - page 226

    Note - In active/cold m aintenance can b e performed o nly for a b uilding b lock config urati on. The inacti ve/cold main tenance pro cedure for a s ingle-chas sis configura tion is the same as that for sto pping the s ystem. For details, see " 6.1 Inc orpor ating an FRU int o the System with the replace fru Comman d ." 3. Incorporate th ...

  • Fujitsu M10-4S - page 227

    Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce ...

  • Fujitsu M10-4S - page 228

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 204 ...

  • Fujitsu M10-4S - page 229

    Chapter 11 Maintaining the Fan Units This chapt er describes the p rocedure for mainta ining the fa n units mounted in the SPARC M10-4/M10-4 S. ■ Configu ration o f the Fan Units ■ Before Ma intaining a Fan Unit ■ Enabling the Remova l of a Fan Unit ■ R e m o v i n gaF a nU n i t ■ Installing a Fan Unit ■ Restoring t he Syst em 11.1 Con ...

  • Fujitsu M10-4S - page 230

    (1) (2) (3) (4) (5) Location numbe r Component 1F a n u n i t ( F A N U # 0 ) 2F a n u n i t ( F A N U # 1 ) 3F a n u n i t ( F A N U # 2 ) 4F a n u n i t ( F A N U # 3 ) 5F a n u n i t ( F A N U # 4 ) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 ...

  • Fujitsu M10-4S - page 231

    Table 11-1 Types of mainte nance for fan unit Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) S ystem stopped Sing le-c hass is co nfig ura tio n Supporte d Unsupport ed Supporte d Supported Su pported Build ing bloc k config uration Supporte d Supported (*2) Supported Sup ported Supp orted *1: For a single-cha ssis configur at ...

  • Fujitsu M10-4S - page 232

    Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. XSCF> showlogs error XSCF> replacefru 11.3 Enabling t ...

  • Fujitsu M10-4S - page 233

    Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Product Notes . Note - Active/cold m aintenan ce can be performed on ly for a build ing block con figur ation. XSCF> showlogs error XSCF> replac ...

  • Fujitsu M10-4S - page 234

    XSCF> showlogs error XSCF> showpparstatus -a XSCF> replacefru XSCF> showlogs error XSCF> replacefru 2. Log in to the XSCF s hell . 3. Execute the sho wlogs command to identify the co mponent requiring maintenance. For details, see " 3.3.5 C hecking lo g infor mation ." 4. Confirm the hardware and softw are configurations. F ...

  • Fujitsu M10-4S - page 235

    Note - In active/cold maint enance can be perform ed only for a buildin g block conf iguratio n. The inactive/c old main tenance proced ure for a single -chassis config uration is the s ame as that fo r stopping the system . XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a ...

  • Fujitsu M10-4S - page 236

    XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure w ...

  • Fujitsu M10-4S - page 237

    Note - Place the removed f an unit on a groun ded antistatic ESD mat. 11.4.1 Accessing a fan unit 1. Remove the front cov er. For details, see " 5.5.3 Re moving the front c over ." 11.4.2 Removing a fan unit 1. Pull out the fan unit w hile raising its lev er. Figure 11-2 Lever o f fan un it 2. Carefully remove the fan unit from its sl ot. ...

  • Fujitsu M10-4S - page 238

    Note - D o not force th e fan un it into t he slot. Usin g excessive for ce may d amag e the component or the chassi s. Note - C heck that th e fan unit is fu lly inserted and sec ured. Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . 11.5 Installing a Fan Unit This se ...

  • Fujitsu M10-4S - page 239

    XSCF> showstatus XSCF> showhardconf Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Product Notes . Note - Active/cold m aintenan ce can be performed on ly for a build ing block con figur atio ...

  • Fujitsu M10-4S - page 240

    Note - In active/cold m aintenance can b e performed o nly for a b uilding b lock config urati on. The inacti ve/cold main tenance pro cedure for a s ingle-chas sis configura tion is the same as that for sto pping the s ystem. Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the reco ...

  • Fujitsu M10-4S - page 241

    Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. 3. Power o n the physical partition requiring maintenance. For details, see " 6.3 Powering On the Physical Pa rtition Requiring Maintenance ." 4. Close the rack doo ...

  • Fujitsu M10-4S - page 242

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 218 ...

  • Fujitsu M10-4S - page 243

    Chapter 12 Maintaining the Internal Disks This chapter descri bes the procedure fo r maint aining the intern al disks mounte d in the SPARC M10-4/M10-4 S. An inte rnal disk can be r eplaced , expand ed, or reduce d. ■ Configuration of the Int ernal Disks ■ Before Ma intaining a n Interna l Disk ■ Enabling the Re moval of an Intern al Disk ■ ...

  • Fujitsu M10-4S - page 244

    (1) (6) (2) (5) (3) (4) (7) (8) Location numbe r Component 1I n t e r n a l d i s k ( H D D # 0 ) 2I n t e r n a l d i s k ( H D D # 1 ) 3I n t e r n a l d i s k ( H D D # 2 ) 4I n t e r n a l d i s k ( H D D # 3 ) 5I n t e r n a l d i s k ( H D D # 4 ) 6I n t e r n a l d i s k ( H D D # 5 ) 7I n t e r n a l d i s k ( H D D # 6 ) 8I n t e r n a l d ...

  • Fujitsu M10-4S - page 245

    XSCF> showhardcon f SPARC M10-4S; + Serial:20812 38017; Operator _Panel_Switc h:Service; + System_Power :Off; System_Ph ase:Cabinet Po wer Off; Partition#0 PP AR_Status:Po wered Off; Partition#1 PP AR_Status:Po wered Off; BB#00 Status:N ormal; Role:Mas ter; Ver:2044h ; Serial:208123 8017; + FRU-Part-Nu mber:CA07361 -D202 A1 ; + Power_Suppl y_Sys ...

  • Fujitsu M10-4S - page 246

    # format Searching for d isks...done AVAILABLE DIS K SELECTIONS: 0. c2t50000394 281B5312d0 <TO SHIBA-MBF260 0RC-3706 cyl 6498 6 alt 2 hd 27 sec 668> <-- (1) /pci@8800/p ci@4/pci@0/p ci@0/scsi@0/ iport@f/disk @w5000039428 1b5312,0 /dev/chassi s/FUJITSU-BB EXP.500000e0 e06d31bf/03N 0 _HDD00/disk <-- (2) (*1) 1. c2t50000394 281B59D6d0 < ...

  • Fujitsu M10-4S - page 247

    * BB#00 CMUL seria l + FRU-Part-Num ber:CA07361- D941 C3 /7060911 ; + Memory_Size: 128 GB; CPU#0 Status:N ormal; Ver:414 2h; Serial:003 21144; + Freq:3.000 GHz; T ype:0x10; + Core:16; Strand :2; CPU#1 Status:N ormal; Ver:414 2h; Serial:003 22957; + Freq:3.000 GHz; T ype:0x10; + Core:16; Strand :2; ----------- ------------ - Ommitted ------- ------- ...

  • Fujitsu M10-4S - page 248

    /dev/chass is/SYS/BB1/C MUL/HDD0 - /dev/chass is/SYS/BB1/C MUL/HDD1 - /dev/chass is/SYS/BB1/C MUL/HDD2 - /dev/chass is/SYS/BB1/C MUL/HDD3 - /dev/chass is/SYS/BB1/C MUL/HDD4 - /dev/chass is/SYS/BB1/C MUL/HDD5 - /dev/chass is/SYS/BB1/C MUL/HDD6 - /dev/chass is/SYS/BB1/C MUL/HDD7 - /dev/chass is/FUJITSU-B BEXP.500000e 0e06d31bf/03 N0 _HDD00/dis k c4t5 ...

  • Fujitsu M10-4S - page 249

    Label Disk name Vendor Product Vers -------- ----- ------------ ----- -------- -------- ------ ---- HDD_0 c0t50000393D 8289180d0 TOSHI BA MBF2600RC 3706 <-- (1) Physical path ------------ ------------ -------- 0: /pci@8000 /p ci@4/pci@0/p ci@0/scsi@0/ iport@f/disk @w50000393D8 289180,0<-- (2) * LSB#0 HDD_1 c0t50000393D 82891D0d0 TOSHI BA MBF2 ...

  • Fujitsu M10-4S - page 250

    XSCF> showboards -a PSB PPAR-ID(L SB) Assignment Pwr Conn Conf Test Fault ---- ------- ----- ------- ---- ---- ---- - --- ------- --- ----- 00 -0 00(00) Assigned y y y Passed Normal *B B # 0 *L S B # 0 01-0 00(01) Assigned y y y Passed Normal Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. ...

  • Fujitsu M10-4S - page 251

    Table 12-3 Maintenanc e flow Detail s of update pro cess Replacement Expa nsion Reducti on 1 Preparation 12.3 12 .3 12.3 2 Removin g an intern al disk 12.4 - 12.4 3 Installing an intern al disk 12.5 12.5 - 4 Restoring th e system 12.6 12.6 12. 6 Note - See the pro cedure for system -stopped m aintenan ce for inactive/cold ma intenance in a single-c ...

  • Fujitsu M10-4S - page 252

    Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. Note - Un less the system h as a redundan t config uration, d ata on the hard d isk drive will be lost. Thus, per form this operati on only after back ing up the data on the hard disk drive ...

  • Fujitsu M10-4S - page 253

    # cfgadm -c unconfigure Ap_ID # cfgadm -x led=fault,mode =blink Ap_ID # cfgadm -a Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Product Notes . Note - Active/cold m aintenan ce can be performed on ...

  • Fujitsu M10-4S - page 254

    Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Note - In active/cold m aintenance can b e performed o nly for a b uilding b lock config urati on. The inacti ve/cold main tenance pro cedure for a s ingle-chas sis configura tion ...

  • Fujitsu M10-4S - page 255

    Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon nec ...

  • Fujitsu M10-4S - page 256

    Note - When performing active/ hot maintenance, a t this point wait until the m otor sto ps rotating (about 1 minut e). 12.4.1 Accessing an internal disk 1. Remove the front cove r. For details, see " 5.5.3 Removing the front cover ." 12.4.2 Removing an internal disk 1. Push the knob on the internal disk to unlock it and then raise the le ...

  • Fujitsu M10-4S - page 257

    Note - Place the removed inte rnal disk on the grounded antistati c ESD mat. Figure 12-3 Removing an in ternal dis k 3. Care fully re move the in tern al disk fr om its s lot. 4. When redu cing an internal disk, install the the internal disk filler unit in the slot from which the disk wa s removed. 12.5 Installing an Internal Disk This section desc ...

  • Fujitsu M10-4S - page 258

    Note - D o not force th e internal d isk into the sl ot. Using e xcessive force m ay dam age the component or the chassi s. Note - Ensure that the inte rnal disks ar e firmly inser ted and secu red. Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . 2. With the l ev er o ...

  • Fujitsu M10-4S - page 259

    # cfgadm -a # cfgadm -c configure Ap_I D # cfgadm -a Note - Use the DR of th e system b oard on a ph ysical partit ion for active/cold ma intenance. For the XC P and Ora cle VM Server for SPA RC/SRU vers ions that corres pond to the DR , see the latest Product Notes . Note - Active/cold m aintenan ce can be performed on ly for a build ing block con ...

  • Fujitsu M10-4S - page 260

    XSCF> testsb -y -p 00-0 Note - In active/cold m aintenance can b e performed o nly for a b uilding b lock config urati on. The inacti ve/cold main tenance pro cedure for a s ingle-chas sis configura tion is the same as that for sto pping the s ystem. 2. Return to the operation of the XSCF firmware replacefru command to confirm that the chassis h ...

  • Fujitsu M10-4S - page 261

    Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. XSCF> testsb -y -p 00-0 Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before ...

  • Fujitsu M10-4S - page 262

    XSCF> testsb -y -p 00-0 During the d iagnosis proce ssing, the probe-scs i-all command of the OpenBoot PROM is exec uted, and the re sult is displayed. 4. Start the entire system. For details, see " 6.4 Starti ng the Entire System ." 5. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ Decemb ...

  • Fujitsu M10-4S - page 263

    Chapter 13 Maintaining the PCI Express Cards This chapt er describes the p rocedure for mainta ining a PCI Expre ss (PCIe) car d mounted in a SPARC M10-4/ M10-4S. A PCIe card can be replaced , expand ed, and reduced. ■ Configuration of the PCI Expr ess Cards ■ Before Main taining a PCI E xpress Card ■ Checkin g If PCI Hot Plug ( PHP) Can Be U ...

  • Fujitsu M10-4S - page 264

    (1) (2) (3) (9) (10) (4) (5) (6) (7) (8) (1 1) Location number Componen t 1 PCIe card (PCI# 0) 2 PCIe card (PCI# 1) 3 PCIe card (PCI# 2) 4 PCIe card (PCI# 3) 5 PCIe card (PCI# 4) 6 PCIe card (PCI# 5) 7 PCIe card (PCI# 6) 8 PCIe card (PCI# 7) 9 PCIe card (PCI# 8) (*) 10 PCIe car d (PCI#9) (*) 11 PCIe card ( PCI#10) (*) *: Can be mounted on ly on a S ...

  • Fujitsu M10-4S - page 265

    Note - Read an d underst and the instr uctions in this ch apter before startin g the main tenance work. Also se e the content s of " Chapter 1 Before St arting M aintenance W ork ." Table 13-1 Types of mainte nance for PCIe c ards Configuration Active/hot (with PHP) Active/h ot (wit h DR) Inacti ve/h ot System s topped Single-ch assis con ...

  • Fujitsu M10-4S - page 266

    Table 13-2 Maintena nce flow Detail s of updat e process Repl acement Expansi on Reduction 1P r e - c h e c k 13.3 13 .3 13.3 2 Prepa ration 13.4 13.4 13 .4 3 Remov ing a PCIe card o r the filler for a PCIe car d 13.5 13.5 13 .5 4 Installing a PCIe card or the f iller for a PCIe car d 13.6 13.6 13 .6 5 Restorin g the system 13.7 13 .7 13.7 13.2.3 P ...

  • Fujitsu M10-4S - page 267

    XSCF> showlogs error # ldm list-io -l NAME TYPE BUS DOMAIN STATUS ---- ---- --- ------ ------ PCIE0 BUS PCIE0 primar y [pci@8000] PCIE1 BUS PCIE1 primar y < --(*1 ) [pci@8100] PCIE2 BUS PCIE2 primary IOV < --(*2) [pci@8200] PCIE3 BUS PCIE3 rootdom < --(*3) [pci@8300] PCIE4 BUS PCIE4 primar y [pci@8400] PCIE5 BUS PCIE5 primar y IOV [pci@ ...

  • Fujitsu M10-4S - page 268

    [pci@8700] /BB0/CMUL/ NET0 PCIE PCIE0 primary OCC [pci@8000/ pci@4/pci@0/ pci@9] network@0 network@0, 1 /BB0/CMUL/ SASHBA PCIE PCIE0 primary OCC [pci@8000/ pci@4/pci@0/ pci@0] scsi@0/ipo rt@f/disk@w5 0000393a8236 8b2,0 scsi@0/ipo rt@f/smp@w50 0000e0e06d03 bf scsi@0/ipo rt@f/enclosu re@w500000e0 e06d03bd,0 scsi@0/ipo rt@v0 /BB0/PCI0 PCIE PCIE1 prima ...

  • Fujitsu M10-4S - page 269

    *6 *8 *5 *7 *5 to *8 in the figure correspond to the above ldm list-io -l command execution example. Assign a PCIe endpoint device to I/O domain Table 13-3 Whether PH P can be used Root Complex PCIe slot Can PHP be used? Remarks Refe rence Control domain Control domain Yes See *5 in the example of executing th e ldm list-io -l c o m m a n da n d* 5 ...

  • Fujitsu M10-4S - page 270

    Table 13-3 Whether PH P can be used (c o ntinu e d ) Root Complex PCIe slot Can PHP be used? Remarks Refer ence Control domain I/O domain No See *6 in th e example of executing t he ldm list- io -l comma nd and *6 in Figure 13-2 . " Table 13-4 Operations when PH P cannot b e used or you do n ot use PHP " Root do main R oot dom ain Yes See ...

  • Fujitsu M10-4S - page 271

    # ldm list-bindings rootdom ----------- ------------ - Ommitted ------- ------------ ----- VSW NAME MAC NET-DEV ID DEVICE LINKPROP DEFAULT-VLA N-ID PVID ...... vsw0 xx:xx: xx:xx:xx:xx net4 (*1) 0 switch@0 1 1 PEER MAC PVID VID MTU MAXBW .. ... vnet0@gues t1 (*2) x x:xx:xx:xx:x x:xx 1 1500 ----------- ------------ - Ommitted ------- ------------ --- ...

  • Fujitsu M10-4S - page 272

    # grep " 0 "ixgbe"" /e tc/path_to_inst "/pci@8100/p ci@4/pci@0/p ci@0/network @0" 0 "ixgbe" # ldm list-bindings rootdom ---------- ------------ -- Ommitte d ------------------- ----- VDS NAME VOLUME OPTIO NS MPGROUP DEVICE vds0 vol0 /export/ vdisks/vdi sk.img (*1) vol1 /dev/z vol/ dsk/rpool/ zvdisk1 vol2 /d ...

  • Fujitsu M10-4S - page 273

    # ldm remove-vnet < virtual network >< guest domain > # ldm remove-vswitch < virtual networ k switch > # ldm remove-vdisk < virtual disk >< guest domain > # ldm remove-vdiskserver < virtual di sk service > # svcadm enable hotplug If MPxIO performs manageme nt, use t he mpathadm command to d isplay the devic e pat ...

  • Fujitsu M10-4S - page 274

    # cfgadm -a Ap_Id Type Receptacl e Occupant Condition BB#0-PCI#0 pci-pci/hp connected configured ok # cfgadm -c unconfigure Ap_Id # cfgadm -c disconnect Ap_Id # cfgadm -a Ap_Id Type Receptacl e Occupant Condition BB#0-PCI#0 pci-pci/hp disconnec ted unconfigur ed ok # cfgadm -x led=attn,mode=blink Ap_Id Note - T o perfor m active/h ot main tenance w ...

  • Fujitsu M10-4S - page 275

    # ldm list-bindings rootdom ----------- ------------ - Ommitted ------- ------------ ----- VSW NAME MAC NET-DEV ID DEVICE LINKPROP DEFAULT-VLA N-ID PVID ...... vsw0 xx:xx: xx:xx:xx:xx net4 0 switch@0 1 1 PEER MAC PVID VID MTU MAXBW .. ... vnet0@gues t1 (*1) x x:xx:xx:xx:x x:xx 1 1500 ----------- ------------ - Ommitted ------- ------------ ----- VD ...

  • Fujitsu M10-4S - page 276

    # ldm stop iodomain # ldm remove-io /BB1/PCI 0 iodomain XSCF> replacefru Note - In active/hot m aintenan ce can be performed on ly for a build ing block co nfigur ation. For a sin gle-chassis co nfigur ation, s ystem-sto pped maint enance sho uld be perf ormed. e. Release from the physical partition the chassis in which the PCIe card requiring m ...

  • Fujitsu M10-4S - page 277

    Caution - Before you handle any compone nts, wea r a wrist strap to ground any static electricity. If you per form this pr ocedure witho ut a wrist strap, individ ual components or the ov erall sys tem may be damaged. For d etails , see " 1.5 Notes Regardin g Static Electricity ." Note - If the cr ossbar cables are fixed t o the cable sup ...

  • Fujitsu M10-4S - page 278

    B A B A Ty p e - 1 Ty p e - 2 B A Figure 13-3 Types of PCIe car d cassettes 1. Low er the lever (B in the figure) of the PCIe card cassette while pu shing the l a t c h( Ai nt h ef i g u r e ) . Figure 13-4 Lever of PCIe card c assette 2. Hold the lever and carefully pull the PCIe card cassette out of the P CI slot to remove it. Fujitsu M10-4/Fujit ...

  • Fujitsu M10-4S - page 279

    Note - Place the rem oved PCIe card cassette o n a groun ded antist atic ESD mat. Figure 13-5 Removing the PCIe card cas set te 13.5.3 Removing a PCI Express card 1. Remove the cover while pushing the clip (A in the figure) at the rear of th e cover. Chapter 13 Maintaining the PCI Express Cards 255 ...

  • Fujitsu M10-4S - page 280

    A Figure 13-6 Clip at rear of cover 2. Remove the screw securing the PCIe card cassette. Figure 13-7 Removin g the screw Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 256 ...

  • Fujitsu M10-4S - page 281

    A Note - Do n ot forcibly rem ove the PCIe card fr om the PCIe card cassette . If excessive force is used to remove th e PCIe card, it m ay be dam aged. Note - Place the remov ed PCIe card on a grounde d antistat ic ESD mat. 3. Remove the bracket (A in the figure) from the PCIe card. Figure 13-8 Removing t he bracket 4. Remove the PCIe card from th ...

  • Fujitsu M10-4S - page 282

    Note - C onfirm that t he tab o f the PC Ie card or th e tab of the fi ller for the PCIe car d is inserted in the n otch of the PC Ie card cassette. Figure 13-9 Removin g the PCIe ca rd 13.6 Installing a PCI Express Card This section describes the pr ocedure for i nstalling a PC Ie card. Perfo rm expansio n using the same pr ocedure. When remo ving ...

  • Fujitsu M10-4S - page 283

    Figure 13-10 Installing a PC Ie card 2. Install the bracket for the PCIe card, and secure it with the screw. Figure 13-11 Installing the brac ket Chapter 13 Maintaining the PCI Express Cards 259 ...

  • Fujitsu M10-4S - page 284

    Note - When mounting a PCIe card cassett e, ch eck the connectors on both of the chassis and PCI e card cassette b eforehand to conf irm that no pin is be nt and all th e pins are neatly arran ged in lines. If a PCIe car d cassette is mounted with a bent pin in a connecto r, the chassis or PC Ie card cassette may be damaged. Also , carefully procee ...

  • Fujitsu M10-4S - page 285

    Note - See the pro cedure for system -stopped m aintenan ce for inactive/cold ma intenance in a single-cha ssis confi guration. # cfgadm -c connect A p_Id # cfgadm -c configure Ap_I d # cfgadm -a Ap_Id Type Receptacle Occupant Condition BB#0-PCI#0 pci-pci/hp connected configured ok # svcadm disable hotplug ■ Active/Hot mai ntenance (with P HP) ? ...

  • Fujitsu M10-4S - page 286

    XSCF> testsb -v -y -s 00 -0 XSCF> testsb -v -y -s 00 -0 7. Close the rack door. 13.7.2 Active/Hot maintenance (with DR) 1. Return to the operation of the XSCF firmware replacefru command to confirm that the chassis ha s been incorporated into the system. For details, see " 6.1 Inc orpor ating an FRU int o the System with the replace fru ...

  • Fujitsu M10-4S - page 287

    XSCF> testsb -v -y -s 00-0 13.7.4 System-stopped maintenance 1. L o gi nt ot h eX S C Fs h e l l . 2. Execute the testsb co mmand to confirm that the P CIe card requiring maintenance is recognized. When yo u input option al "-y" for the testsb co mmand, the syste m autom atically answers "y" (yes) in re sponse to an inq uiry. ...

  • Fujitsu M10-4S - page 288

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 264 ...

  • Fujitsu M10-4S - page 289

    Caution - Do not replace a PSU backpla ne unit at th e same time as a CPU memory unit. If you re place a PSU backp lane unit at t he same time as a CPU memory uni t, the system may fai l to operate normal ly. Repla ce a PSU backplan e unit or CPU memory unit, and confir m that the newly in stalled part is nor mal by using th e showhar dconf or show ...

  • Fujitsu M10-4S - page 290

    (1) Location number Componen t 1 PSU backpla ne unit (PSUB P) Figure 14-1 Location of PSU bac kplane unit 14.2 Before Maintaining the PSU Backplane Unit This section describes the types and the flow of m aintenance o f the PSU back plane unit. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 266 ...

  • Fujitsu M10-4S - page 291

    Note - Read an d underst and the instr uctions in this ch apter before startin g the main tenance work. Also se e the content s of " Chapter 1 Before St arting M aintenance W ork ." Table 14-1 Types of ma intenan ce for PSU back plane unit Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) S ystem stopped Sing le-c hass ...

  • Fujitsu M10-4S - page 292

    Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. Note - Use the DR of the system board on a phys ical par ti ...

  • Fujitsu M10-4S - page 293

    Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. Note - In active/cold maint enance can be perform ed only for a buildin g block conf iguratio n. The inactive/c old main tenance proced ure for a single -c ...

  • Fujitsu M10-4S - page 294

    XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure w ...

  • Fujitsu M10-4S - page 295

    Note - Mak e a note of the p ositions of the cab les connected to the e xternal interf ace before disconnectin g them to ens ure that they are rein stalled correctly . Note - Mak e a note of t he positions of t he PCIe card cassettes bef ore remov ing them to e nsure that they are reinst alled correctly. Note - If n o crossbar un it is mounte d, pr ...

  • Fujitsu M10-4S - page 296

    Note - M ake a note o f the positions of the p ower supply un its before remov ing them t o ensure that the y are reinstalled cor rectly. Note - Make a n ote of the l ocations of th e fan units befor e removing them to ensu re that they are reinstalled c orrectly. Note - M ake a note o f the positions of the in ternal disks be fore removin g them t ...

  • Fujitsu M10-4S - page 297

    Note - Place the removed PS U backplane unit on a gr ounded antist atic ESD mat. Figure 14-4 Screws in the f an slot 14.4.2 Removing the PSU backplane unit 1. Loosen the two screws securing the PSU b ackplane unit and then partially pull out the PSU ba ckplane unit. Figure 14-5 Screws securing the PSU back plane unit 2. Pull th e PSU b ackplan e un ...

  • Fujitsu M10-4S - page 298

    Figure 14-6 Handle of PSU backp lane unit 3. Remov e the ope rati on panel. For details, see step 2 and later i n " 15.4.2 Removing the op eration panel ." 14.5 Installing the PSU Backplane Unit This section describes the pr ocedure for i nstalling the PSU b ackplane u nit. 14.5.1 Installing the PSU backplane unit 1. Install the operation ...

  • Fujitsu M10-4S - page 299

    Note - Inst all the power sup ply units in the ir origin al position s by referr ing to t he notes th at you m ade prior to the star t of mainte nance. Note - Rein stall the fan un its in their orig inal locatio ns by referrin g to the notes y ou m ade prior to the start o f mainten ance. Note - Reinst all the intern al disks in their or iginal loc ...

  • Fujitsu M10-4S - page 300

    Note - Re connect the cab les of the external in terface in their ori ginal positi ons by referrin g to the notes tha t you made prior to the s tart of maintenanc e. Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . Note - Use the DR of the system board on a phys ical p ...

  • Fujitsu M10-4S - page 301

    XSCF> diagxbu -y -b 00 -p 02 XSCF> showlogs error Note - In active/cold maint enance can be perform ed only for a buildin g block conf iguratio n. The inactive/c old main tenance proced ure for a single -chassis config uration is the s ame as that fo r stopping the system . Note - In the case of a dual powe r feed, conn ect the pow er cords i ...

  • Fujitsu M10-4S - page 302

    XSCF> diagxbu -y -b 00 - t 01 XSCF> showlogs error Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. 3. Execute the diagxb u command to diagnose the crossbar cab les. Diagno sis is perfor med when the system bo ard of ...

  • Fujitsu M10-4S - page 303

    XSCF> diagxbu -y -b 00 -t 01 XSCF> showlogs error The example belo w specifies the following: 00: BB-ID of t he chassis to start the diag nosis 01: BB-ID of the destination w here the chassis to start the di agnosis is con nected (You can specify on e or more of these.) To specify multiple connectio n destination BB-IDs, enter a comm and like ...

  • Fujitsu M10-4S - page 304

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 280 ...

  • Fujitsu M10-4S - page 305

    Chapter 15 Maintaining the Operation Panel This chapt er describes the p rocedure for mainta ining the op eration pane l mounted on the SPARC M10-4/M10-4 S. ■ Location o f the Oper ation P anel ■ Before Main taining th e Operation Pane l ■ Enabling the Remova l of the Operation Panel ■ Removin g the Operatio n Panel ■ Installing the Oper ...

  • Fujitsu M10-4S - page 306

    (1) Location numbe r Component 1 Operatio n panel (OP NL) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 15-1 Location of the operat ion panel 15.2 Before Maintaining the Operation Panel This secti ...

  • Fujitsu M10-4S - page 307

    Table 15-1 Types of mainte nance for ope ration pane l Configuration Active/hot Active/cold Inactive/hot Inactive/cold (*1) S ystem stopped Sing le-c hass is co nfig ura tio n Unsupported U nsupported Un supported Su pported Supported Build ing bloc k config uration Unsupported S upported (*2) Unsu pported Supporte d Supported *1: For a single-cha ...

  • Fujitsu M10-4S - page 308

    Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. Note - Use the DR of the system board on a phys ical par tition for ac tive/col d maintenance . For the XC P and Oracle VM Serve r for SPAR C/SRU versio ns that correspon d to the DR, see t ...

  • Fujitsu M10-4S - page 309

    Note - In active/cold maint enance can be perform ed only for a buildin g block conf iguratio n. The inactive/c old main tenance proced ure for a single -chassis config uration is the s ame as that fo r stopping the system . XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a ...

  • Fujitsu M10-4S - page 310

    XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure w ...

  • Fujitsu M10-4S - page 311

    Note - Mak e a note of the p ositions of the cab les connected to the e xternal interf ace before disconnectin g them to ens ure that they are rein stalled correctly . Note - Mak e a note of t he positions of t he PCIe card cassettes bef ore remov ing them to e nsure that they are reinst alled correctly. Note - If n o crossbar un it is mounte d, pr ...

  • Fujitsu M10-4S - page 312

    Figure 15-2 Screws secu ring the mounting frame 7. Loosen the screw securing the CPU memory unit and low er the ri ght and left levers to the horizontal position. Figure 15-3 Screw se curing CPU memory unit 8. Pull out the CPU memory unit by about 10 cm (3.9 in.) 9. Remove the front cove r. For details, see " 5.5.3 Removing the front cover .&q ...

  • Fujitsu M10-4S - page 313

    Note - Mak e a note of the locat ions of the fa n units before re moving t hem to ensure t hat they are reinstalled correctl y. 12. Loosen the tw o screws in the fan slot and then remove the fan shelf. Figure 15-4 Screws in the f an slot 15.4.2 Removing the operation panel 1. Loosen the two screws securing the PSU b ackplane unit and partially pull ...

  • Fujitsu M10-4S - page 314

    A Note - Place the removed op eration pa nel on a grounded antis tatic ESD mat. Figure 15-6 Cables a nd screws o f the operatio n panel 3. Pull the operation panel forward to remove i t. 15.5 Installing the Operation Panel This section describes the pr ocedure for i nstalling the oper ation panel. 15.5.1 Installing the operation panel 1. Set the BB ...

  • Fujitsu M10-4S - page 315

    Note - Reinst all the fan un its in their orig inal positio ns by referrin g to the notes y ou made prior to the start o f mainten ance. Note - Check that the front co ver is firmly a ttached and s ecured. Note - If n o crossbar un it is mounte d, proceed to step 11. Note - Rein stall the PCIe card cassettes in t heir origin al positions by referr ...

  • Fujitsu M10-4S - page 316

    Note - Re connect the cab les of the external in terface in their ori ginal positi ons by referrin g to the notes tha t you made prior to the s tart of maintenanc e. Note - See the procedur e for system-s topped maint enance for inac tive/col d maintenance i n a single-ch assis config uration . Note - Use the DR of the system board on a phys ical p ...

  • Fujitsu M10-4S - page 317

    XSCF> diagxbu -y -b 00 -p 02 XSCF> showlogs error Note - In active/cold maint enance can be perform ed only for a buildin g block conf iguratio n. The inactive/c old main tenance proced ure for a single -chassis config uration is the s ame as that fo r stopping the system . Note - In the case of a dual powe r feed, conn ect the pow er cords i ...

  • Fujitsu M10-4S - page 318

    XSCF> diagxbu -y -b 00 - t 01 XSCF> showlogs error Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. physical p artition into which the ch assis is inco rporated is powered of f. The example bel ow specifies the follo ...

  • Fujitsu M10-4S - page 319

    XSCF> diagxbu -y -b 00 -t 01 XSCF> showlogs error 00: BB-ID of t he chassis to start the diag nosis 01: BB-ID of the destination w here the chassis to start the di agnosis is con nected (You can specify on e or more of these.) To specify multiple connectio n destination BB-IDs, enter a comm and like "diagxbu -y -b 00 -t 01 -t 0 2". ...

  • Fujitsu M10-4S - page 320

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 296 ...

  • Fujitsu M10-4S - page 321

    Chapter 16 Maintaining the Crossbar Units of the Crossbar Box This chapter descri bes the procedure fo r maint aining the cro ssbar units m ounted on the crossbar box. ■ Configuration of the Crossbar Uni ts ■ Before Ma intaining a Crossbar Unit ■ Enabling the Remova l of a Crossbar Uni t ■ Removing a Crossbar Unit ■ Installing a Cr ossbar ...

  • Fujitsu M10-4S - page 322

    (3) (2) (1) Location number Componen t 1 Crossbar unit (XB UX#0) 2 Crossbar unit (XB UX#1) 3 Crossbar unit (XB UX#2) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 16-1 Location of crossbar units 1 ...

  • Fujitsu M10-4S - page 323

    Table 16-1 Types of ma intenan ce for the crossbar un it Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Unsupported S upported (*1) Unsu pported Supporte d Supported (* 2) *1: If any physical partiti on mounte d on two or m ore chassis is cur rently operating, the cr ossbar bo x cannot ...

  • Fujitsu M10-4S - page 324

    XSCF> showlogs error Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . XSCF> showlogs error Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure ...

  • Fujitsu M10-4S - page 325

    XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. 16.3.3 System-stopped maintenance 1. Open the rack do or. 2. L o gi nt ot h eX S C Fs h e l l . 3. Execute the ...

  • Fujitsu M10-4S - page 326

    Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, individu al components or th e overall sys tem may be damaged. For d etails , see " 1.5 Notes Regarding Static Electricity ." Note - M ake a note o f the positions of the cr ossbar c ...

  • Fujitsu M10-4S - page 327

    Note - Place the remov ed crossba r unit on a grounded antis tatic ESD mat. Note - When mo unting a crossb ar unit, check the connector s on both of the chassis and crossb ar unit befo rehand to con firm that no pin is bent and all the pi ns are neatly arranged in l ines. If a cros sbar unit is mount ed with a ben t pin in a connector, the chassis ...

  • Fujitsu M10-4S - page 328

    Note - Re install the crossb ar cables (optical) in their orig inal positio ns by referrin g to the notes that y ou ma de prior to the start o f mainten ance. Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. XSCF> diagx ...

  • Fujitsu M10-4S - page 329

    Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. XSCF> diagxbu -y -b 00 -t 01 Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made b ...

  • Fujitsu M10-4S - page 330

    XSCF> diagxbu -y -b 00 - t 01 XSCF> showlogs error Diagno sis is perfor med when the system bo ard of the chassis con nected with the crossbar cables is n ot incor porated into the physical partition, o r when th e physical p artition into which the ch assis is inco rporated is powered of f. The example bel ow specifies the followin g: 00: BB ...

  • Fujitsu M10-4S - page 331

    Chapter 17 Maintaining the XSCF Unit of the Crossbar Box This chapt er describes the p rocedure for mainta ining the XS CF unit mounted in the crossbar box. ■ Location o f the XSCF Unit ■ Before Ma intaining the XSCF Uni t ■ Enabling the Remova l of the XSCF Unit ■ Removing the XSCF Un it ■ Installing the XSC F Unit ■ Restoring t he Sys ...

  • Fujitsu M10-4S - page 332

    (1) Location number Componen t 1 XSCF unit (XSCFU) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 17-1 Location of XSCF unit 17.2 Before Maintaining the XSCF Unit This se ction des cribes t he type ...

  • Fujitsu M10-4S - page 333

    Table 17-1 Type of maintenanc e for XSCF unit Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Supporte d (*1) Unsupported (*2) Supporte d Unsupport ed (*2) Supporte d (*3) *1: The XS CF must be config ured as a sla ve before mai ntenance is s tarted. I f the XSCF is o perating as th e m ...

  • Fujitsu M10-4S - page 334

    XSCF> showlogs error XSCF> switchscf -t Standby XSCF> replacefru XSCF> showlogs error 17.3.1 Active/Hot maintenance 1. Open the rack do or. 2. Log in to the XSCF s hell . 3. Execute the sho wlogs command to identify the co mponent requiring maintenance. For details, see " 3.3.5 C hecking lo g infor mation ." 4. Confirm the har ...

  • Fujitsu M10-4S - page 335

    XSCF> replacefru XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. For details, see " 5.3 Powering Off the Physical Partition Requiring Maintenance .&quo ...

  • Fujitsu M10-4S - page 336

    Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, individu al components or th e overall sys tem may be damaged. For d etails , see " 1.5 Notes Regarding Static Electricity ." Note - The cables connec ted to the rea r of the cross b ...

  • Fujitsu M10-4S - page 337

    A Figure 17-2 Posit ions of screws and leve rs 3. Hold the levers and parti ally pull out the XSCF unit. Chapter 17 Maintaining the XSCF Unit of t he Crossbar Box 313 ...

  • Fujitsu M10-4S - page 338

    Note - P lace the removed XS CF unit o n a groun ded antistat ic ESD mat. Note - When mounting a XSCF unit , chec k the conn ectors on both of the chass is and XSCF unit befo rehand to co nfirm th at no pin is bent and all the pin s are neatly arrange d in lines. If an XSCF u nit is mounte d with a bent pin in a con nector, the chassis or XSCF un i ...

  • Fujitsu M10-4S - page 339

    Note - Reinst all the cables in their orig inal positio ns by referrin g to the notes th at you m ade prior to the start o f mainten ance. Note - After co nnecting t he cables, use the ho ok-and -loop fastener t o bundle an d fix the cables to the cable suppor t at the rear. XSCF> switchscf -t Active T h ec a b l e st ob er e c o n n e c t e da ...

  • Fujitsu M10-4S - page 340

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. that the XSCF unit has been incorporated into the system. For details, see " 6.1 Inc orpor ating an FRU int o the System with the replace fru Comman d ." 2. Pow er ...

  • Fujitsu M10-4S - page 341

    Chapter 18 Maintaining the Power Supply Units of the Crossbar Box This chapt er describes the p rocedure for mainta ining the power suppl y units mounted in a crossb ar box. ■ Configu ration of the Power Su pply Units ■ Before Ma intaining a Power Supply U nit ■ Enabling t he Removal of a Power Supp ly Unit ■ R e m o v i n gaP o w e rS u p ...

  • Fujitsu M10-4S - page 342

    (1) (2) Location number Componen t 1 Power suppl y unit (PSU#0 ) 2 Power suppl y unit (PSU#1 ) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 18-1 Locations o f power supply units 18.2 Before Maint ...

  • Fujitsu M10-4S - page 343

    Table 18-1 Types of ma intenan ce for the power supply un it Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Supporte d (*1) Unsupported (*2) Supporte d Unsupport ed (*2) Supporte d (*3) *1: Active/hot repla cement can b e performed onl y with a redundant co nfiguration . *2: If any phy ...

  • Fujitsu M10-4S - page 344

    Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. Note - Active/hot maintena nce is sup ported only for a re dundant configurati on. XSCF> showlogs error XSCF> replacefru of a power s upply unit. The pre paration pr ocedure differs d ...

  • Fujitsu M10-4S - page 345

    XSCF> showlogs error XSCF> replacefru XSCF> showlogs error XSCF> replacefru maintenance. For details, see " 3.3.5 C hecking log i nform ation ." 4. Confirm the hardware and softw are confi gurations. For details, see " 4.2 Confirming the S ystem Configura tion ." 5. Power off the physical partit ion requiring mainten ...

  • Fujitsu M10-4S - page 346

    Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, individu al component ...

  • Fujitsu M10-4S - page 347

    A B Note - Place the remov ed power supp ly unit on the grounded ESD mat to groun d any static elect ricity. Note - Do n ot forcibly push t he power supply unit in to its slot. Using e xcessive force may damage th e compone nt or the chassis . Figure 18-2 R e m o v i n gap o w e rs u p p l yu n i t 2. Support the po wer supply unit w i th one hand ...

  • Fujitsu M10-4S - page 348

    Note - C heck that th e power supply u nit is fully inserte d and that the lever is fi xed. XSCF> showstatus XSCF> showhardconf 18.6 Restoring the System This section describes the pr ocedure for restoring th e system after installin g a power supply unit. The r estoration procedure di ffers depending on the maintena nce type as follows: ■ ...

  • Fujitsu M10-4S - page 349

    Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. 3. Return to the operation of the XSCF firmware replacefru command to confirm that the power supp ly unit has been incorporated into the system. For details, see " 6.1 I ...

  • Fujitsu M10-4S - page 350

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 326 ...

  • Fujitsu M10-4S - page 351

    Chapter 19 Maintaining the Fan Units of the Crossbar Box This chapt er describes the p rocedure for mainta ining the fa n units mounted in a crossbar box. ■ Configu ration o f the Fan Units ■ Before Ma intaining a Fan Unit ■ Enabling the Remova l of a Fan Unit ■ R e m o v i n gaF a nU n i t ■ Installing a Fan Unit ■ Restoring t he Syst ...

  • Fujitsu M10-4S - page 352

    (1) (2) (3) (4) Location number Componen t 1 Fan unit ( FANU# 0) 2 Fan unit ( FANU# 1) 3 Fan unit ( FANU# 2) 4 Fan unit ( FANU# 3) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 19-1 Location of fa ...

  • Fujitsu M10-4S - page 353

    Table 19-1 Types of mainte nance for fan unit Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Supporte d Unsupport ed (*1) Supporte d Unsupport ed (*1) Supporte d (*2) *1: If any physical partiti on is currently oper ating, the cros sbar box ca nnot be powered o ff. *2: All the physical ...

  • Fujitsu M10-4S - page 354

    Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. XSCF> showlogs error XSCF> replacefru XSCF> showlogs error fan unit. The p reparation proc edure dif fers de pending on th e maintenanc e type as follows: ■ Active/Hot mainten an ...

  • Fujitsu M10-4S - page 355

    XSCF> replacefru XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. 4. Confirm the hardware and softw are confi gurations. For details, see " 4.2 Confirmi ...

  • Fujitsu M10-4S - page 356

    Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, individu al components or th e overall sys tem may be damaged. For d etails , see " 1.5 Notes Regarding Static Electricity ." A 19.4 Removing a Fan Unit This section describes the pr ...

  • Fujitsu M10-4S - page 357

    Note - Place the removed f an unit on a groun ded antistatic ESD mat. Note - Do n ot force the fan un it into the slot. Usin g excessive force ma y damag e the compone nt or the chassis . Note - Check that the fan unit i s fully inser ted and secu red. 19.5 Installing a F an Unit This section describes the pr ocedure fo r installing a fa n unit. 19 ...

  • Fujitsu M10-4S - page 358

    XSCF> showstatus XSCF> showhardconf Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. 19.6.1 Active/Hot maintenance 1. Return to the operation of the XSCF firmware replacefru command to confirm that the fan unit has b ...

  • Fujitsu M10-4S - page 359

    For details, see " 6.1 Inc orpor ating an FR U into the System with the repl acefru Comman d ." 3. Power on all the physical partitions. For details, see " 6.3 Powering On the Physical Pa rtition Requiring Maintenance ." 4. Close the rack door. Chapter 19 Maintaining the Fan Units of t he Crossbar Box 335 ...

  • Fujitsu M10-4S - page 360

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 336 ...

  • Fujitsu M10-4S - page 361

    Chapter 20 Maintaining the XSCF Interface U nit of the Crossbar Box This chapt er describes the p rocedure for mainta ining the XS CF interfac e unit mounted in a crossb ar box. ■ Location o f the XSCF Interface Unit ■ Before Mainta ining the XSCF Interface Unit ■ Enabling the Remova l of the XSCF Interface Uni t ■ Removing the XSCF I nterf ...

  • Fujitsu M10-4S - page 362

    (1) Location number Componen t 1 XSCF inter face unit (XS CFIFU) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 20-1 Location of XSCF i nterface un it 20.2 Before Maintaining the XSCF I nterface Un ...

  • Fujitsu M10-4S - page 363

    Table 20-1 Type of maintenanc e for XSCF interface unit Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Unsupported U nsupported (*1) Unsupported U nsupported (*1) Supporte d (*2) *1: If any physical partiti on is currently oper ating, the cros sbar box ca nnot be powered o ff. *2: All ...

  • Fujitsu M10-4S - page 364

    Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, individu al component ...

  • Fujitsu M10-4S - page 365

    A Figure 20-2 Posit ions of screws and leve rs 3. Hold the levers and parti ally pull out the XSCF interface unit. Figure 20-3 Pulling o ut the XSCF interface unit 4. Support the XSCF interface unit from below w ith one hand and then carefully remove it from the chassis. Chapter 20 Maintaining the XSCF Interface Unit of the Crossbar Box 341 ...

  • Fujitsu M10-4S - page 366

    Note - P lace the removed XS CF interface u nit on a gr ounded ant istatic ESD m at. Note - Wh en mountin g an XSCF interface unit, check the conne ctors on both of the chassis and XSC F interface un it beforehan d to confirm th at no pin is bent a nd all the pins are neatly arran ged in lines. If an XSCF in terface unit is mo unted with a bent pin ...

  • Fujitsu M10-4S - page 367

    Chapter 21 Maintaining the Crossbar Backplane Unit of the Crossbar Box This chapter descri bes the procedure fo r maint aining the cro ssbar back plane unit mounted in a crossb ar box. ■ Location o f the Crossba r Backplane Un it ■ Before Main taining th e Crossbar Backpla ne Unit ■ Enabling the Remova l of the Crossbar Backplane Uni t ■ Re ...

  • Fujitsu M10-4S - page 368

    (1) Location number Componen t 1 Crossbar bac kplane un it (XBBPU ) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 21-1 Location of crossbar backplan e unit 21.2 Before Maintaining the Crossbar Bac ...

  • Fujitsu M10-4S - page 369

    Table 21-1 Types of mainte nance for cro ssbar backpl ane unit Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Unsupported U nsupported (*1) Unsupported U nsupported (*1) Supporte d (*2) *1: If any physical partiti on is currently oper ating, the cros sbar box ca nnot be powered o ff. * ...

  • Fujitsu M10-4S - page 370

    XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, i ...

  • Fujitsu M10-4S - page 371

    A A BC B 2. Remove the front cov er. For details, see " 5.5.3 Re moving the front c over ." 3. Remove all the fan uni ts. For details, see " 19.4 Removing a Fan Unit ." 4. Loosen the t wo screw s (A in the figure) securing the u pper cover and slide the right and left stoppers (B in the figure) inw a rds. Then, remove the upper ...

  • Fujitsu M10-4S - page 372

    A Figure 21-3 Removin g the lower co ver 6. Disconnect the tw o cables from the fan shelf. Arrange the remov ed cables in the cent er. Figure 21-4 Removin g the cables 7. Loosen the three screws securing the fan shelf and partially pull out the fan shelf. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 348 ...

  • Fujitsu M10-4S - page 373

    Note - Rem ove the fan shelf w hile paying caref ul attention t o the two cables arran ged in the cente r. Note - Place t he removed fan shelf on a gr ounded a ntistatic ESD mat . Figure 21-5 Removing the fa n shelf 8. Place a hand u nder the fan shelf to sup port it and then carefully remove it from t he chassis . 9. Loosen the t wo screw s and re ...

  • Fujitsu M10-4S - page 374

    A B Figure 21-6 Removin g the bracket 10. Slide the guide plate (A in the figure) to the front to remove it . Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 350 ...

  • Fujitsu M10-4S - page 375

    A Note - Move t he clamps back t o their orig inal positions s o that they do not fou l the removal of the crossb ar back plane un it. Figure 21-7 Removing g uide plate 11. Remove the cable from the clamp s. Chapter 21 Maintaining the Crossbar Backplane Unit of t he Crossbar Box 351 ...

  • Fujitsu M10-4S - page 376

    Note - Remove the unit careful ly so as to not damage any cabl es. Note - P lace the removed crossb ar backp lane unit on a gr ounde d antistatic ESD m at. Figure 21-8 Removin g the cables 12. Loosen the fi v e screws secu rin g the cr ossbar bac kplane u nit and then pul l the crossbar backplane unit straight out by holding the center handle (A in ...

  • Fujitsu M10-4S - page 377

    A Figure 21-9 Removing the cros sbar backplane unit 21.5 Installing the Crossbar Backplane Unit This section describes the pr ocedure fo r installing the cro ssbar bac kplane unit. 1. Insert the crossbar backplane unit into the chassis and then tighten the fiv e screws. 2. Fix the cables of the cro ssbar backplane un it with the clamps. 3. Install ...

  • Fujitsu M10-4S - page 378

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. Check the guide pl ate latch to ensure that the pl ate is securely installed. 4. Suppor t the fa n shelf from be low with one hand a nd then i nsert i t care full y into the ...

  • Fujitsu M10-4S - page 379

    XSCF> diagxbu -y -b 00 -t 01 XSCF> diagxbu -y -b 00 -p 02 XSCF> showlogs error 3. Execute the di agxbu comma nd to dia gnose the c rossba r cables . - When the system board of the chassis con nected with the crossbar cables is not incorporated into the ph ysical partition, or when the incorporated physical partition is powered off: The exa ...

  • Fujitsu M10-4S - page 380

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 356 ...

  • Fujitsu M10-4S - page 381

    Chapter 22 Maintaining the Fan Backplane of the Crossbar Box This chapt er describes the p rocedure for mainta ining the fa n backplane mounted in the crossbar box. ■ Configu ration o f the Fan Backpla ne ■ Before Main taining th e Fan Backplane ■ Enabling the Remova l of the Fan Backplane ■ Removing the Fan Ba ckplane ■ Installing the Fa ...

  • Fujitsu M10-4S - page 382

    (1) Location number Componen t 1 Fan backplan e (FANBP) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 22-1 Location of fan backplane 22.2 Before Maintaining the Fan Backplane This section describe ...

  • Fujitsu M10-4S - page 383

    Table 22-1 Types of mainte nance for fan backp lane Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Unsupported U nsupported (*1) Unsupported U nsupported (*1) Supporte d (*2) *1: If any physical partiti on is currently oper ating, the cros sbar box ca nnot be powered o ff. *2: All of t ...

  • Fujitsu M10-4S - page 384

    XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure w ...

  • Fujitsu M10-4S - page 385

    A A BC B 2. Remove all the fan uni ts. For details, see " 19.4 Removing a Fan Unit ." 22.4.2 Removing the fan backplane 1. Loosen the t wo screw s (A in the figure) securing the u pper cover and then slide the right and left stoppers (B in the figure) inw ards. Then, remove the upper cover (C in the figure). Figure 22-2 Removing t he uppe ...

  • Fujitsu M10-4S - page 386

    A Figure 22-3 Removin g the lower co ver 3. Disconnect the tw o cables from the fan shelf. Arrange the remov ed cables in the cent er. Figure 22-4 Removin g the cables 4. Loosen the three screws securing the fan shelf and partially pull out the fan shelf. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 362 ...

  • Fujitsu M10-4S - page 387

    Note - Rem ove the fan shelf w hile paying caref ul attention t o the two cables arran ged in the cente r. Note - Place t he removed fan shelf on a gr ounded a ntistatic ESD mat . Figure 22-5 Removing the fa n shelf 5. Place a hand u nder the fan shelf to sup port it and then carefully remove it from t he chassis . 6. Disconnect the tw o cables fro ...

  • Fujitsu M10-4S - page 388

    Figure 22-6 Removin g the cables 7. Remove the two screw s securing the fan backplane to remove the bracket (A in the figure). Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 364 ...

  • Fujitsu M10-4S - page 389

    A Note - Place th e removed fan back plane on a gr ounded antistat ic ESD m at. Figure 22-7 Removing t he screws and b racket 8. Remove the fan backplane. 22.5 Installing the F an Backplane This section describes the pr ocedure fo r installing the fan backpla ne. 22.5.1 Installing the fan backplane 1. Fit the fan backplane into the right- and left ...

  • Fujitsu M10-4S - page 390

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. 6. Connect the two cable s to the fan shel f. 7. Install the lower cover and then secure it with the one scre w. 8. Insta ll t he upper co ve r. 9. Slide the right and left ...

  • Fujitsu M10-4S - page 391

    Chapter 23 Maintaining the Operation Panel of the Crossbar Box This chapt er describes the p rocedure for mainta ining the op eration pane l mounted on the crossbar box . ■ Location o f the Oper ation P anel ■ Before Main taining th e Operation Pane l ■ Enabling the Remova l of the Operation Panel ■ Removin g the Operatio n Panel ■ Instal ...

  • Fujitsu M10-4S - page 392

    (1) Location number Componen t 1 Operation panel ( OPNL) Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Figure 23-1 Location of the operat ion panel 23.2 Before Maintaining the Operation Panel This sectio ...

  • Fujitsu M10-4S - page 393

    Table 23-1 Types of mainte nance for ope ration pane l Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Unsupported U nsupported (*1) Unsupported U nsupported (*1) Supporte d (*2) *1: If any physical partiti on is currently oper ating, the cros sbar box ca nnot be powered o ff. *2: All t ...

  • Fujitsu M10-4S - page 394

    XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure w ...

  • Fujitsu M10-4S - page 395

    A A BC B crossbar box requiring maintenance. 2. Remove the front cover of the crossbar box. For details, see " 5.5.3 Re moving the front c over ." 3. Remove all the fan uni ts. For details, see " 19.4.2 Removing a fan unit ." 4. Loosen the t wo screw s (A in the figure) securing the u pper cover and then slide the right and left ...

  • Fujitsu M10-4S - page 396

    A Figure 23-3 Removin g the lower co ver 6. Disconnect the tw o cables from the fan shelf. Arrange the remov ed cables in the cent er. Figure 23-4 Removin g the cables 7. Loosen the three screws securing the fan shelf and partially pull out the fan shelf. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 372 ...

  • Fujitsu M10-4S - page 397

    Note - Rem ove the fan shelf w hile paying caref ul attention t o the two cables arran ged in the cente r. Note - Place t he removed fan shelf on a gr ounded a ntistatic ESD mat . Figure 23-5 Removing the fa n shelf 8. Place a hand u nder the fan shelf to sup port it and then carefully remove it from t he chassis . 23.4.2 Removing the operation pan ...

  • Fujitsu M10-4S - page 398

    Front Figure 23-6 Operation panel cable 2. Loosen the one scre w securing the operation panel and then remove it. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 374 ...

  • Fujitsu M10-4S - page 399

    Front Note - Place th e removed oper ation pane l on a g rounded antist atic ESD m at. Figure 23-7 Removing the o peration pa nel 23.5 Installing the Operation Panel This section describes the pr ocedure fo r installing the oper ation panel. Chapter 23 Maintaining the Operation Panel of the Crossbar B ox 375 ...

  • Fujitsu M10-4S - page 400

    Front 23.5.1 Installing the operation panel 1. Set the BB- ID of the ope rati on panel to t he va lue pri or to the st art of maintenance. 2. Inser t the ope rati on panel int o the fan s helf a nd then sec ure i t with the sc rew. Figure 23-8 Installing the o peration panel 3. Reinstall the cable betw een the fan shelf and the o peration panel. Fu ...

  • Fujitsu M10-4S - page 401

    Front Figure 23-9 Operat ion panel cable 23.5.2 Restoring the chassis 1. Suppor t the fa n shelf from below with one ha nd and inse rt i t int o the chass is. Then, tighten the three screws. 2. Connect t he two cables to t he fan shel f. 3. Install the lower cove r and then secure it with the one screw . 4. Install the upper cove r and slide the ri ...

  • Fujitsu M10-4S - page 402

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. For details, see " 19.5.1 Installing a fan unit ." 6. Install the front cove r of the crossbar b ox. For details, see " 6.5.3 In stalling the fr ont cover .&q ...

  • Fujitsu M10-4S - page 403

    Chapter 24 Maintaining the Crossbar Cables (Electrical) This chapter descri bes the procedure fo r maint aining the cro ssbar cables (electric al). ■ Configuration of t he Ports for the Crossbar Cables (E lectri cal) ■ Before Main taining a Crossbar Cabl e (Elec trical) ■ Enabling t he Removal of a Crossbar Cable ( Elect rical) ■ Removin g ...

  • Fujitsu M10-4S - page 404

    1R 2L 2R 0R 0L 1L 1R 2L 2R 0R 0L 1L 1R 2L 2R 0R 0L 1L 1R 2L 2R 0R 0L 1L XBU#0 XBU#1 Figure 24-1 Connectio n ports for c rossbar c ables (electrical) Figure 24-2 Crossbar cables ( elec trical) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 380 ...

  • Fujitsu M10-4S - page 405

    Location number Component 1 Crossbar cab les (electrical) (CBL ) Note - Read an d underst and the instr uctions in this ch apter before startin g the main tenance work. Also se e the content s of " Chapter 1 Before St arting M aintenance W ork ." Table 24-1 Types of mainte nance for cro ssbar cabl es (electric al) Configuration Active/hot ...

  • Fujitsu M10-4S - page 406

    Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. XSCF> showlogs error XSCF> replacefru 24.2.3 Precautions for replacement Note the following point s when replacing a cross bar cable (electrical): ■ Replace cro ssbar ca bles (elect ...

  • Fujitsu M10-4S - page 407

    Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o ...

  • Fujitsu M10-4S - page 408

    Cauti on - Before yo u handle any c ompone nts, wear a wrist strap to grou nd any static electricity. If you per form this pr ocedure witho ut a wrist strap, individu al components or th e overall sys tem may be damaged. For d etails , see " 1.5 Notes Regarding Static Electricity ." 24.4 Removing a Crossbar Cable (Electrical) This section ...

  • Fujitsu M10-4S - page 409

    A Figure 24-3 Removing the cr ossbar ca bles (electrical) 2. Remove the two crossb ar cables (electrical) from the other chassis. Remove th e crossb ar cable (electrical) by holding the t ab of the cable an d pulling it strai ght out in the d irect ion of the arrow. At this time, do not hold the cab le part when pulli ng the crossb ar cable. Pulli ...

  • Fujitsu M10-4S - page 410

    Note - If you insert a connecto r with the tab pul led, the co nnector may be damaged. Note - C heck that th e crossbar cables (electrical ) are correctly con nected and secure. Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ...

  • Fujitsu M10-4S - page 411

    XSCF> showlogs error Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. XSCF> diagxbu -y -b 00 -t 01 XSCF> showlogs error 4. Execute the show logs command to confirm that the system is operating normally. For details ...

  • Fujitsu M10-4S - page 412

    For details, see " 3.3.5 C hecking lo g infor mation ." 5. Pow er on all the physical partitions. For detai ls, see " 6.3 Pow erin g On th e Physi cal Par tition R equi ring M ainte nan ce ." 6. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 388 ...

  • Fujitsu M10-4S - page 413

    Chapter 25 Maintaining the Crossbar Cables (Optical) This chapter descri bes the procedure fo r maint aining the cro ssbar cables (o ptical). ■ Configuration of t he Ports for the Crossbar Cables (Op tical) ■ Before Main taining a Crossbar Cab le (Optica l) ■ Enabling t he Removal of a Crossbar Cable ( Optical) ■ Removing a Crossbar Cable ( ...

  • Fujitsu M10-4S - page 414

    1R 2L 2R 0R 0L 1L 1R 2L 2R 0R 0L 1L 1R 2L 2R 0R 0L 1L 1R 2L 2R 0R 0L 1L XBU#0 XBU#1 L0 L2 L3 L1 L0 L2 L3 L1 L4 L6 L7 L5 L4 L6 L7 L5 R0 R2 R3 R1 R0 R2 R3 R1 R4 R6 R7 R5 R4 R6 R7 R5 #2 #1 #0 L0 L2 L3 L1 L0 L2 L3 L1 L4 L6 L7 L5 L4 L6 L7 L5 R0 R2 R3 R1 R0 R2 R3 R1 R4 R6 R7 R5 R4 R6 R7 R5 L0 L2 L3 L1 L0 L2 L3 L1 L4 L6 L7 L5 L4 L6 L7 L5 R0 R2 R3 R1 R0 R2 ...

  • Fujitsu M10-4S - page 415

    Location number Component 1 Crossbar cab les (optical) (CB L) Figure 25-3 Crossbar cables (op tical) (SPARC M10-4S) Figure 25-4 Crossbar cables (op tical) (crossbar box) Chapter 25 Maintaining the Crossbar Cables (Optical) 391 ...

  • Fujitsu M10-4S - page 416

    Note - Re ad and un derstand the in structions in t his chapter before st arting the m aintenan ce work. A lso see the con tents of " Chapter 1 Before Star ting M aintenan ce Work ." Table 25-1 Types of ma intenance f or crossbar cables (o ptical) Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped With a crossb ...

  • Fujitsu M10-4S - page 417

    Caution - To co mpletely shut dow n the system, all the power c ords must be removed. If the powe r cords are n ot removed, an electr ical failure may occu r. XSCF> showlogs error XSCF> replacefru ■ Do not bend the cr ossbar ca bles (optical) un duly. If you u nduly bend a cr ossbar cable (optic al), it may be dam aged. Ensure that the stat ...

  • Fujitsu M10-4S - page 418

    Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th a ...

  • Fujitsu M10-4S - page 419

    Caution - Before you handle any compone nts, wea r a wrist strap to ground any static electricity. If you per form this pr ocedure witho ut a wrist strap, individ ual components or the ov erall sys tem may be damaged. For d etails , see " 1.5 Notes Regardin g Static Electricity ." Enable the re moval of the cro ssbar ca bles (optical) bef ...

  • Fujitsu M10-4S - page 420

    Note - There is no problem if you remove t he crossba r cables a t the cros sbar box while electricity is su pplied. Note - T he cables at the rear o f the crossbar bo x are bundled to gether and f astened to the right-h and cable supp ort with a hoo k-and -loop fastener . To remove th e crossbar cables (optical), th erefore, rem ove the h ook- and ...

  • Fujitsu M10-4S - page 421

    (1) (1) Number in figure Description 1T a b Note - Confirm that the cros sbar cable s (optical ) are corr ectly connec ted and se cure. Note - After inst alling the cr ossbar cables (optic al), use the hoo k-and -loop fastener t o bundle the cables toge ther and secure them to the rea r cable suppor t. Figure 25-7 Crossbar cabl e (optica l) shapes ...

  • Fujitsu M10-4S - page 422

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. XSCF> diagxbu -y -b 00 - t 01 XSCF> showlogs error Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o t ...

  • Fujitsu M10-4S - page 423

    XSCF> diagxbu -y -b 00 -t 01 XSCF> showlogs error For details, see " 6.1 Inc orpor ating an FR U into the System with the repl acefru Comman d ." 3. Execute the di agxbu comma nd to dia gnose the c rossba r cables . Diagnosis is pe rformed when the syst em board of the chassis conne cted wi th the crossba r cables is not inc orporat ...

  • Fujitsu M10-4S - page 424

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 400 ...

  • Fujitsu M10-4S - page 425

    Chapter 26 Maintaining the XSCF BB Control Cables This chapt er describes the p rocedure for mainta ining the XS CF BB control cab les. ■ Configuration of t he Ports for the XS CF BB Control Cable s ■ Before Ma intaining a n XSCF BB Control Cable ■ Enabling t he Removal of an XSCF BB Cont rol Cable ■ Removing an XSCF B B Control Cable ■ I ...

  • Fujitsu M10-4S - page 426

    (1) (1) Location number Componen t 1 XSCF BB co ntrol cables (S CF_CBL ) Figure 26-1 Locations of XSCF BB contro l cables (SPARC M10-4S) Figure 26-2 Locations of XSCF BB contro l cables (crossbar box) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 402 ...

  • Fujitsu M10-4S - page 427

    Note - Read an d underst and the instr uctions in this ch apter before startin g the main tenance work. Also se e the content s of " Chapter 1 Before St arting M aintenance W ork ." Table 26-1 Types of mainte nance for XSCF BB cont rol cable Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k co ...

  • Fujitsu M10-4S - page 428

    Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. XSCF> showlogs error XSCF> switchscf -t Standby 26.3 Enabling the Removal of an XSCF BB Control Cable This section describes pre paration s that must be co mpleted prior to re moving ...

  • Fujitsu M10-4S - page 429

    XSCF> replacefru XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. XSCF> showlogs error For details, see " 5.1 Relea sing an FRU fr om the System wit ...

  • Fujitsu M10-4S - page 430

    XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . For details, see " 3.3.5 C hecking lo g infor mation ." 4. Confirm the hardware and softw are configurations. For details, se ...

  • Fujitsu M10-4S - page 431

    XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. Caution - Before you handle any compone nts, wea r a wrist strap to ground any static electricity. If you per f ...

  • Fujitsu M10-4S - page 432

    Note - T he cables on the rear of th e crossbar box are b undled tog ether and faste ned to the right-h and cable supp ort with a hoo k-and -loop fastener . When rem oving the XS CF BB control cab les, remove the ho ok-a nd-loo p fastener from t he cable support. A A Figure 26-3 Removin g the XSCF BB contro l cables (S PARC M 10-4S) Fujitsu M10-4/F ...

  • Fujitsu M10-4S - page 433

    Figure 26-4 Removing t he XSCF BB cont rol cables (c rossbar box) 2. Remove the XSCF BB co ntrol cables from the other chas sis. Pull out an XSCF BB contr ol cable while pu shing the lock rele ase buttons (A in the figure) on the both sid es of the cable. 26.5 Installing an XSCF BB Control Cable This section describes the pr ocedure fo r installing ...

  • Fujitsu M10-4S - page 434

    Note - C heck that th e XSCF BB co ntrol cables are correct ly connected an d secure. Note - Afte r connecting th e XSCF BB cont rol cable, use the h ook- and-loo p fastener to bun dle the cables to gether an d secure the m to the rear cab le support. XSCF> switchscf -t Active Note - In t he case of a dual power feed, co nnect the power cord s i ...

  • Fujitsu M10-4S - page 435

    Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. 2. Return to the operation of the XSCF firmware replacefru command to confirm that the chassis has been incorporated into the system. For details, see " 6.1 Inc orpor at ...

  • Fujitsu M10-4S - page 436

    Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. 2. Return to the operation of the XSCF firmware replacefru command to confirm that the chassis ha s been incorporated into the system. For details, see " 6.1 Inc orpor ...

  • Fujitsu M10-4S - page 437

    Chapter 27 Maintaining the X SCF DUAL Cont rol Cables This chapter descri bes the procedure fo r maint aining the XSCF D UAL contro l cables. ■ Configuration of the XSCF DUAL Control Ports ■ Before Ma intaining a n XSCF DUAL Control Cable ■ Enabling t he Removal of an XSCF DUAL Cont rol Cable ■ Removing an XSCF DUAL Control Cable ■ Instal ...

  • Fujitsu M10-4S - page 438

    (1) (1) Location numbe r Component 1 XSCF DUAL control cable s (SCF_DUAL) Figure 27-1 Location of XSCF DUA L control port ( SPARC M10-4S) Figure 27-2 Location of XSCF DUA L control port ( crossbar box) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 414 ...

  • Fujitsu M10-4S - page 439

    Note - Read an d underst and the instr uctions in this ch apter before startin g the main tenance work. Also se e the content s of " Chapter 1 Before St arting M aintenance W ork ." Table 27-1 Types of mainte nance for the X SCF DUAL control cabl es Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing b ...

  • Fujitsu M10-4S - page 440

    Cauti on - To co mpletely shut down the sy stem, all the power cor ds must be removed. If the po wer cords are n ot remo ved, an electrical failur e may occ ur. XSCF> showlogs error XSCF> switchscf -t Standby 27.3 Enabling the Removal of an XSCF DUAL Control Cable This se ction des cribes the preparat ion that must be comp leted p rior to rem ...

  • Fujitsu M10-4S - page 441

    XSCF> replacefru XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. XSCF> showlogs error For details, see " 5.1 Relea sing an FRU fr om the System wit ...

  • Fujitsu M10-4S - page 442

    XSCF> showlogs error XSCF> replacefru Note - In the c ase of a dual power feed, m ake a note o f the locations o f the power cords before discon necting the m to ensure th at they are reinsta lled correctly . For details, see " 3.3.5 C hecking lo g infor mation ." 4. Confirm the hardware and softw are configurations. For details, se ...

  • Fujitsu M10-4S - page 443

    XSCF> showlogs error XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. Caution - Before you handle any compone nts, wea r a wrist strap to ground any static electricity. If you per f ...

  • Fujitsu M10-4S - page 444

    Note - T he cables on the rear of th e crossbar box are b undled tog ether and faste ned to the right-h and cable supp ort with a hoo k-and -loop fastener . To remove th e XSCF DUA L contro l cables, therefore , remove the h ook-an d-loo p fastener from t he cable support. Figure 27-3 Removin g the XSCF DUAL co ntrol ca bles (SPARC M10-4S ) Figure ...

  • Fujitsu M10-4S - page 445

    Note - Check that XSCF DUAL control c able is c orrectl y connected a nd secure. Note - After c onnecting the X SCF DUAL control cabl e, use the hook-a nd-loop faste ner to bundle the cabl es together and fast en them to rear cable suppor t. 2. Remove the XSCF DUAL control cables from the other chassis. Pull out the XSC F DUAL contr ol cable while ...

  • Fujitsu M10-4S - page 446

    XSCF> showstatus XSCF> showhardconf Note - In t he case of a dual power feed, co nnect the power cord s in their orig inal positions b y referring t o the record that y ou made be fore the start of m aintenan ce. XSCF> showstatus XSCF> showhardconf normally after the completion of maintenance. 3. Execute the show hardconf command to che ...

  • Fujitsu M10-4S - page 447

    Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce ...

  • Fujitsu M10-4S - page 448

    Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 424 ...

  • Fujitsu M10-4S - page 449

    Chapter 28 Maintaining the Cable Kit of the Crossbar Box This chapter descri bes the procedure fo r maint aining the cable kit mounted o n the crossbar box. ■ Configuration of t he Cable Kit ■ Before Main taining th e Cable Kit ■ Enabling t he Removal of the Cabl e Kit ■ Removing the Cabl e Kit ■ Installing the Ca ble Kit ■ Restoring t ...

  • Fujitsu M10-4S - page 450

    (1) (2) Location numbe r Component 1 Conn ector (term inal bo ard (SIG) side ) 2 Conn ector (crossb ar backplane unit side ) (1) (2) Location numbe r Component 1 Connector (termi nal board (PWR) side) 2 Conn ector (crossb ar backplane unit side ) Figure 28-1 Cable (SIG) (between the cros sbar backplane unit and terminal board) ■ Cable (PWR) Cable ...

  • Fujitsu M10-4S - page 451

    (1) (2) Location n umber Com ponent 1 Conne ctor (termin al board side) 2 Conne ctor (fan back plane (PW R) side) 28.1.2 Cables for the connec tion between the terminal board and fan backplane ■ Cable (PWR) Cable for the con nection be tween th e terminal board and f an backplane (PWR) Figure 28-3 Cable (PWR) (b etwee n the termina l board and fa ...

  • Fujitsu M10-4S - page 452

    (1) (2) (3) Location numbe r Component 1 Connector (termi nal board side) 2 Conn ector (fan back plane (SIG) s ide) 3 Conn ector (oper ation pa nel side) Figure 28-4 Cable (SIG) (fo r the terminal board a nd fan back plane to the operation pa nel) 28.1.3 Locations for the cable kit T h el o c a t i o n so fc a b l ek i tc o n n e c t i o n sa r ea ...

  • Fujitsu M10-4S - page 453

    (1) (2) (3) (5) (4) Location number Component C onnecti on 1 Cable (SIG) Cross bar backpla ne unit and ter minal boar d (SIG) 2 Cable (PWR ) Crossb ar backplane u nit and term inal board ( PWR) 3T e r m i n a l b o a r d 4 Cable (SIG) Term inal boar d (SIG) and fan back plane 5 Cable (PWR ) Term inal board (PW R) and fan b ackplane Note - Read an d ...

  • Fujitsu M10-4S - page 454

    Table 28-1 Types of main tenance f or cable kit Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Building block c onfiguration Unsuppor ted Unsupported (*1) Unsuppor ted Unsupported (*1) Supported (*2 ) *1: If any physical partiti on is currently opera ting, the crossb ar box can not be powered o ff. *2: Al l the physi ...

  • Fujitsu M10-4S - page 455

    XSCF> replacefru Note - I nt h ec a s eo fad u a lp o w e rf e e d ,m a k ean o t eo ft h el o c a t i o n so ft h ep o w e rc o r d s before discon necting the m to ensure that t hey are reinstalled c orrectly. Caution - Before you handle any compone nts, wea r a wrist strap to ground any static electricity. If you per form this pr ocedure with ...

  • Fujitsu M10-4S - page 456

    A A BC B A 3. Loosen the t wo screw s (A in the figure) securing the upper cover and then slide the right and left stoppers (B in the figure) inw ards. Then, remove the upp er cover (C in t he fig ure). Figure 28-6 Removin g the upper cove r 4. Loosen the o ne screw (A in the figure) securing the low er cover and then slide th e lower cover t o the ...

  • Fujitsu M10-4S - page 457

    Note - Rem ove the fan shelf w hile paying caref ul attention t o the two cables arran ged in the cente r. Note - Place t he removed fan shelf on a gr ounded a ntistatic ESD mat . Figure 28-8 Removing the cab les 6. Loosen the three screw s securing the fan shelf and partially pull out the fan shelf. Figure 28-9 Removing the fa n shelf 7. Place a h ...

  • Fujitsu M10-4S - page 458

    Figure 28-10 Removin g the cable (cable (S IG)) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 434 ...

  • Fujitsu M10-4S - page 459

    Figure 28-11 Removing the cab le (cable (PWR)) 9. Remove the cable from the clamps. Chapter 28 Maintaining the Cable Kit of t he Crossbar Box 435 ...

  • Fujitsu M10-4S - page 460

    Figure 28-12 Removin g the cables 28.4.2 Removing the cables for the connection between the terminal board and fan backplane Remove th e cable (SIG) or ca ble (PWR) c onnecting th e terminal board and fan backplane. 1. Remove the front cove r. For details, see " 5.5.3 Removing the front cover ." 2. Remove all the fan units. For details, s ...

  • Fujitsu M10-4S - page 461

    A A BC B A Figure 28-13 Removing t he upper cover 4. Loosen the one scre w (A in the figure) securing the lower cove r and then slide the lower cover to the left to remov e it. Figure 28-14 R e m o v i n gt h el o w e rc o v e r 5. Disconne ct the two cable s from the f an shelf . Arrange t he remo ved cables in th e center. Chapter 28 Maintaining ...

  • Fujitsu M10-4S - page 462

    Note - Re move the fan sh elf while payi ng careful atten tion to the tw o cables arran ged in the center. Note - P lace the removed fan sh elf on a gro unded ant istatic ESD mat. Figure 28-15 Removin g the cables 6. Loosen the three screws securing the fan shelf and partially pull out the fan shelf. Figure 28-16 Removin g the fan shelf 7. Place a ...

  • Fujitsu M10-4S - page 463

    Figure 28-17 Removing the cab le (cable (PWR)) Figure 28-18 Removing th e cable (ca ble (SIG)) 9. Remove the cable connecting the fan shelf and operation panel from the Chapter 28 Maintaining the Cable Kit of t he Crossbar Box 439 ...

  • Fujitsu M10-4S - page 464

    Front connec tor on t he opera tion pane l. Perform this s tep only wh en removing the cab le (SIG). To remove the cabl e (PWR), proce ed to st ep 10. Figure 28-19 Operation panel cable 10. Remove the cable from the terminal bo ard. ■ For the cable (PWR) , push the connector toward the back while p ushing up the lower latch (A in the figure) with ...

  • Fujitsu M10-4S - page 465

    A B Figure 28-20 Removing the cab le (cable (PWR)) ■ For the ca ble (SIG), remove the two c able connecto r screws with a Ph illips screwdriver ( bit No. 1), and then re move the cable fr om the termi nal boar d. Chapter 28 Maintaining the Cable Kit of t he Crossbar Box 441 ...

  • Fujitsu M10-4S - page 466

    Figure 28-21 Removin g the cable (cable (S IG)) 11. Remove the cable from the clamps. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 442 ...

  • Fujitsu M10-4S - page 467

    Figure 28-22 Removing the cab le (cable (PWR)) Chapter 28 Maintaining the Cable Kit of t he Crossbar Box 443 ...

  • Fujitsu M10-4S - page 468

    Figure 28-23 Removin g the cable (cable (S IG)) 28.5 Installing the Cable Kit This section describes the pr ocedure for i nstalling the cable k it at each cable connection destin ation. For the cable conn ection de stinat ions, se e " 28.1 Configuration of the Cabl e Kit ." Install a cab le that has the same shape as t he removed cab le. ...

  • Fujitsu M10-4S - page 469

    Figure 28-24 Connector sh ape (cable (SIG)) 2. Secure the cable with a clamp. 3. Suppor t the fan shel f from be low with one hand and then inse rt it ca reful ly into the chassis. Arrangin g the cables in the center makes it easier to in stall the fan shelf. 4. Tighten the three screws securing the fan shelf. 5. Connect t he two cables to t he fan ...

  • Fujitsu M10-4S - page 470

    C B A Figure 28-25 Installing the cable (cable (PWR)) - For the ca ble (SIG), install the connecto r that has a thre aded hole to the terminal b oard. U s et h e s c r e wt h a tw a sr e m o v e df r o mt h es a m el o c a t i o nb e f o r e .T i g h t e nt h e screw with a Philli ps screwdriver (bit N o. 1). When installi ng the connecto r, orient ...

  • Fujitsu M10-4S - page 471

    A Figure 28-26 Installing the cable (ca ble (SIG)) 2. Connect the cable to the connector of the fan backplane. 3. Connect the cable conne cting the fan shelf and operation panel to the connect or on the opera tion pane l. Perfor m this step only when inst alling the cable (SIG). To install th e cable (PWR), proce ed to step 4. Chapter 28 Maintainin ...

  • Fujitsu M10-4S - page 472

    Front Figure 28-27 Operation panel cable 4. Secure the cable with a clamp. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 448 ...

  • Fujitsu M10-4S - page 473

    Figure 28-28 Secur ing the cable ( cable (PWR)) Chapter 28 Maintaining the Cable Kit of t he Crossbar Box 449 ...

  • Fujitsu M10-4S - page 474

    Figure 28-29 Securing the cable (cabl e (SIG)) 5. Suppor t the fa n shelf from be low with one hand a nd then i nsert i t care full y into the chassis. Arrang ing the cables in the center makes it easier to in stall the fan shelf. 6. Tighten the three screws securing the fan sh elf. 7. Connect the two cable s to the fan shel f. 8. Install the lower ...

  • Fujitsu M10-4S - page 475

    Note - In the case of a dual powe r feed, conn ect the pow er cords in th eir original po sitions by referring to t he record tha t you made before the s tart of maintena nce. XSCF> diagxbu -y -b 00 -t 01 XSCF> diagxbu -y -b 00 -p 02 XSCF> showlogs error 28.6 Restoring the System This section describes the pr ocedure fo r restoring the sy ...

  • Fujitsu M10-4S - page 476

    For details, see " 3.3.5 C hecking lo g infor mation ." 5. Pow er on all the physical partitions. For detai ls, see " 6.3 Pow erin g On th e Physi cal Par tition R equi ring M ainte nan ce ." 6. Close the rack door. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 452 ...

  • Fujitsu M10-4S - page 477

    Chapter 29 Maintaining the Dedicated Power Distribution Unit Mounted on the Rack for Expanded Connection This chapt er describes the p rocedure for mainta ining the d edica ted power dist ribution unit (P DU) mounted on the rac k for expanded connection. ■ Configuration of the Ded icated Power Distribut ion Unit ■ Before Main taining th e Dedic ...

  • Fujitsu M10-4S - page 478

    (4) (3) (2) (1) Rear Location numbe r Component 1 Dedicated pow er distribut ion unit (P DU#0) 2 Dedicated pow er distribut ion unit (P DU#1) 3 Dedicat ed power di stribution uni t (PDU#2) (*) 4 Dedicat ed power di stribution uni t (PDU#3) (*) *: This is m ounted when the two exp anded conn ection ra cks have been i nstalled. Figure 29-1 Location o ...

  • Fujitsu M10-4S - page 479

    Note - Read an d underst and the instr uctions in this ch apter before startin g the main tenance work. Also se e the content s of " Chapter 1 Before St arting M aintenance W ork ." Table 29-1 Types of PDU m aintenan ce Configuration Active/hot Active/cold Inactive/hot Inactive/cold System stopped Build ing bloc k config uration Unsupport ...

  • Fujitsu M10-4S - page 480

    Caution - Act ive/cold m aintenance can be per formed o nly when th e power supply u nit has a redunda nt config uration. Note - M ake a note o f the locations of the p ower cords before d isconnecting the m, to ensure that they are re connected cor rectly. Note - M ake a note o f the locations of the p ower cords before d isconnecting the m, to en ...

  • Fujitsu M10-4S - page 481

    Caution - Before you handle any compone nts, wea r a wrist strap to ground any static electricity. If you per form this pr ocedure witho ut a wrist strap, individ ual components or the ov erall sys tem may be damaged. For d etails , see " 1.5 Notes Regardin g Static Electricity ." Caution - Two pe ople must be present w hen the power ca b ...

  • Fujitsu M10-4S - page 482

    Figure 29-2 PDU screws 2. Grasp the top and bottom of the PDU, and th en pull it out. Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 458 ...

  • Fujitsu M10-4S - page 483

    Note - H old the plugs o f the power cables, and t hen pull them s traight o ut. Figure 29-3 Pulling out the PDU 3. Disconnect all the po wer cables from the re ar of the PDU. Chapter 29 Maintaining the Dedicated Power Distribution Unit Mounted on the Rack for Expanded Connection 459 ...

  • Fujitsu M10-4S - page 484

    A A Figure 29-4 PDU power c ables The number of power cabl es and the p lug type may vary dep ending on the power envir onment, as foll ows: - For a single-phase pow er feed: Four power cables are connected to the PDU. To pull t hem out, push th e upper and lower l atches (A in t he figure). Figure 29-5 Power cable co nnector for single -phase powe ...

  • Fujitsu M10-4S - page 485

    A Note - H old each power cable pl ug, and the n insert it straigh t into the socket . Note - Ensure t hat the power cab les are correctly con nected and secure. (A in the fig ure) co unterclockwi se. Figure 29-6 Power cabl e connector for thr ee-phas e power feed 29.5 Installing the Dedicated Power Distribution Unit This section describes the pr o ...

  • Fujitsu M10-4S - page 486

    Note - Reconnect the powe r cords at the ir original loc ations by ref erring to the note s you made prior to t he start of maint enance. Note - Reconnect the powe r cords at the ir original loc ations by ref erring to the note s you made prior to t he start of maint enance. ■ System-stopped m aintenance 29.6.1 Active/Cold maintenance 1. Connect ...

  • Fujitsu M10-4S - page 487

    (4) (13) (1) (2) (14) (3) (7) (8) (6) (9) (10) (5) (12) (1 1) (2) (15) Appendix A Component List This append ix describ es components tha t constitut e the SPARC M10-4/M10-4S, t he crossbar box, and the expand ed connection rack. Figure A-1 Locat ions of components of SPARC M10-4/M10-4S 463 ...

  • Fujitsu M10-4S - page 488

    Location numbe r Component 1 CPU me mory un it upper 2 Side cover 3 Memory 4 PSU back plane unit 5F a n s h e l f 6F a n u n i t 7 Front cove r 8 Internal d isk 9 Power sup ply unit 10 Operation pa nel 11 PCI Expres s card ca ssette 12 PCI Express ca rd 13 Crossb ar unit mo unting fra me (*) 14 Crossb ar unit (*) 15 CPU memory unit lower *: Not mou ...

  • Fujitsu M10-4S - page 489

    (4) (1) (2) (14) (3) (7) (6) (9) (5) (13) (12) (8) (1 1) (10) Location n umber Com ponent 1 XSCF inter face unit 2 Crossbar b ackplane u nit 3 Fan backpla ne 4F a n s h e l f 5F a n u n i t 6 Upper cover 7 Lower cover 8 Front cove r 9 Guide plate fixin g brack et 10 Guide plate 11 Operatio n panel 12 Power su pply unit 13 Crossbar uni t Figure A-2 ...

  • Fujitsu M10-4S - page 490

    Location numbe r Component 14 XSCF un it (2) (3) (1) Rear Location numbe r Component 1 Dedicated pow er distribut ion unit 2 Expande d connection rack 3 Crossbar b ox Figure A-3 Locations of com ponents of e xpanded con nection r ack Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 466 ...

  • Fujitsu M10-4S - page 491

    Appendix B Component Specifications This appendix pro vides the specifications o f the compon ents. The com ponents that c onstitute the SP ARC M 10-4/M1 0-4S and the crossba r box are as follows. Components that constitut e the SPARC M10-4/M10-4S ■ CPU Memory Unit ■ Crossba r Unit ■ Power Sup ply Unit ■ Fan Unit ■ Internal Disk D rive ? ...

  • Fujitsu M10-4S - page 492

    Table B-1 Specif ications of CPU memory uni t (SPARC M10-4/M10-4S) Item Descr ipti on Maximum number of CPU memo ry unit s 2 Location Insid e of chassis Type of m ainten ance Active/cold, in active/cold, a nd system sto pped Maintenan ce categor y Replacement , expansio n, and re duction Table B-2 Specifications o f crossbar un it (SPARC M1 0-4/M10 ...

  • Fujitsu M10-4S - page 493

    Table B-2 Specifications of cr ossbar un it (SPARC M10 -4/M10- 4S) (c o ntinu e d ) Item Descr iptio n Type of m aintenan ce Inactive/cold and sy stem-stop ped Maintenan ce category R eplacement Table B-3 Specifications of cr ossbar un it (crossbar box ) Item Descr iptio n Number o f crossbar un its 3 Location Re ar of chassis Type of m ainten ance ...

  • Fujitsu M10-4S - page 494

    Table B-4 Specifications o f XSCF un it (crossbar b ox) (c o ntinu e d ) Item Descr ipti on Maintenanc e category Replac ement Table B-5 Specifications of th e power suppl y un it (SPARC M 10-4/M10 -4S) Item Descr ipti on Number o f power supply units 2 Location Fro nt of chassi s Type o f mainten ance Active/h ot, active/co ld, inactive/h ot, inac ...

  • Fujitsu M10-4S - page 495

    Table B-7 Specifications of f an unit (SP ARC M1 0-4/M10- 4S) Item Descr iptio n Number of fan units 5 Location Fron t of chassis Type of m aintenan ce Active/hot , active/cold, inact ive/hot, inact ive/cold, and sy stem stopped Maintenan ce category R eplacement Table B-8 Specifications of f an unit (cro ssbar box) Item Descr iptio n Number of fan ...

  • Fujitsu M10-4S - page 496

    Table B-9 Specifications o f the internal dis k drive (SPA RC M10- 4/M10-4S ) (c o ntinu e d ) Item Descr ipti on Location Fro nt of chassi s Type o f mainten ance Active/h ot, active/co ld, inactive/h ot, inactive /cold, and system stopped Maintenan ce categor y Replacement , expansio n, and re duction Table B-10 Specifications of P CIe card (SPAR ...

  • Fujitsu M10-4S - page 497

    Table B-11 Specifications of XS CF interf ace unit (crossbar b ox) (c o ntinu e d ) Item Descr iptio n Location Re ar of chassis Type of m ainten ance System st opped Maintenan ce category R eplacement For the maintena nce procedure, see " Chapter 20 Maintaini ng the XSCF Inter face Unit of the Cro ssbar Box ." B.9 Backplanes The backplan ...

  • Fujitsu M10-4S - page 498

    A Table B-12 Specifications of PS U backplane u nit (SPAR C M10- 4/M10-4S ) Item Descr ipti on Number of PSU backplane u nits 1 Location Insid e of chassis Type of m ainten ance Active/cold, in active/cold, a nd system sto pped Maintenanc e category Replac ement Figure B-1 Location of backp lane of SPARC M10-4/M10-4S Table B-12 lists the specific a ...

  • Fujitsu M10-4S - page 499

    B A Table B-13 Specifications of cr ossbar backpla ne unit (cross bar box) Item Descr iptio n Number of cross bar backplane un its 1 Location Inside of cha ssis Type of m ainten ance System st opped Maintenan ce category R eplacement Table B-14 Specifications of f an backp lane (crossbar b ox) Item Descr iptio n Number of fan backpla nes 1 Figure B ...

  • Fujitsu M10-4S - page 500

    Table B-14 Specifications of fa n backplane (cr ossbar box) (c o ntinu e d ) Item Descr ipti on Location Insid e of chassis Type of m ainten ance System sto pped Maintenanc e category Replac ement Table B-15 Specifications o f operation panel (SPA RC M10- 4/M10-4S ) Item Descr ipti on Number of opera tion panels 1 Location Front of chassi s Type of ...

  • Fujitsu M10-4S - page 501

    Table C-1 iostat(1M) co mman d options Optio n Des crip tion Applic ation No options Reports the sta tus of the local I/O device. Allows you to vie w the devic e status concisely in 3 lines. -c Reports the rates of period s during which the system has been in user mode, syst em mo de, I/O wait ing, and idling . Allows you to vie w the CPU statu s a ...

  • Fujitsu M10-4S - page 502

    Table C-1 iostat(1M ) comma nd options (con t i nued) Option Description Application -e Displays a summ ary of stat istics on the device errors . Displayed items are the total number of error s, hardware err ors, softw are errors, and transfer err ors. Allows you to vi ew the accumulate d numbe r of er rors a s a conci se ta ble and to ide ntify po ...

  • Fujitsu M10-4S - page 503

    Table C-2 prtdiag(1M) c ommand option Optio n Des crip tion Applic ation No option s Disp lays a list of com ponents. Allows y ou to check t he CPU information, the memory config uration , the moun ted PCI Express (PC Ie) cards, the OpenBootPROM vers ion, the mode switch status, an d the CPU operation m ode. -v Displays in form ation in det ailed ( ...

  • Fujitsu M10-4S - page 504

    11 30 00 MHz SPARC64-X on-line ---------- ------------ --Ommitted-- ------------ ---------- 59 30 00 MHz SPARC64-X on-line 60 30 00 MHz SPARC64-X on-line 61 30 00 MHz SPARC64-X on-line 62 30 00 MHz SPARC64-X on-line 63 30 00 MHz SPARC64-X on-line ========== ============ = Physical Memory Co nfiguration == ============ ========== Segment Table : --- ...

  • Fujitsu M10-4S - page 505

    pci@0/pci@0 /QLGC,qlc@0, 2 /BB0/PCI0 PCIE QLGC,qlc- pciex1077,80 01 QLE8152 5.0GTx4 /pci@8100/p ci@4/pci@0/p ci@0/pci@0/p ci@0/pci@0/p ci@1/ pci@0/pci@0 /QLGC,qlc@0, 3 /BB0/PCI0 PCIE emlx-pcie x10df,f100 LPe12002-M8-FJ2. 5GTx8 /pci@8100/p ci@4/pci@0/p ci@0/pci@0/p ci@0/pci@0/p ci@1/ pci@0/pci@1 0/pci@0/pci@ 0/emlx@0 /BB0/PCI0 PCIE emlx-pcie x10df,f ...

  • Fujitsu M10-4S - page 506

    Table C-3 prtconf( 1M) command options Option Description Application No options Disp lays a devic e tree fo r the devices recognize d by Oracle Solaris. A hardware device is reg arded as operating n ormal ly if it is recognized . If the message "(dr iver not attached )" is displayed f or a devic e or a sub-devi ce, the dri ver for the de ...

  • Fujitsu M10-4S - page 507

    obp-tftp (dr iver not att ached) zfs-file-sys tem (driver not attached ) hsfs-file-sy stem (driver not at tached) chosen (driver n ot attached) openprom (driv er not attached) client-servi ces (driver not attached ) options, insta nce #0 aliases (dr iver not att ached) memory (driver n ot attached) virtual-mem ory (driver not att ached) iscsi-hba ( ...

  • Fujitsu M10-4S - page 508

    network, insta nce #2 network, insta nce #3 pci, instan ce #1 pci, instance #7 pci, instance #8 pci, instan ce #9 pci, instan ce #10 pci, instan ce #11 pci, instan ce #2 pci, instance #1 2 pci, instance #13 pci, instan ce #14 pci, instan ce #15 pci, instan ce #16 pci, instan ce #17 pci, instan ce #3 pci, instance #1 8 pci, instance #19 pci, instan ...

  • Fujitsu M10-4S - page 509

    pci, instance #1 09 pci-perform ance-counter s, instance #0 pci-perform ance-counter s, instance #1 pci-perform ance-counter s, instance #2 pci-perform ance-counter s, instance #3 pci-perform ance-counter s, instance #4 pci-perform ance-counter s, instance #5 pci-perform ance-counter s, instance #6 pci-perform ance-counter s, instance #7 pci-perfor ...

  • Fujitsu M10-4S - page 510

    Table C-4 netsta t(1M) command options Option Description Application -i Displays the interfac e status. The displayed con tent includes information on i ncoming and outgoing packet s, incoming an d outgo ing errors, co llisions, and queues. Allows y ou to v iew a concise overview of t he netw ork status . -i interval Spe cifying a numeric value af ...

  • Fujitsu M10-4S - page 511

    Table C-5 ping(1M) command opti ons Optio n Des crip tion Applic ation hostname Wh en you send a probe pac ket to hostname , a message is retur ned. A l l o w sy o ut oc o n f i r m t h a tah o s ti s activ e on the network. -g hostname F orces the prob e packet to go throug h the specif ied gateway . Allows yo u to test the quality o f individual ...

  • Fujitsu M10-4S - page 512

    Table C-6 ps(1M) command option s Option Description Application -e Displays inform ation on var ious processes. Allows y ou to v iew the process IDs and files th at can be e xecuted. -f Generates a com plete list. Allows yo u to view process inform ation such as t he user ID, t he parent process I D, the executi on time, and the p aths to the exec ...

  • Fujitsu M10-4S - page 513

    0.0 470 /usr/lib/ autofs/autom ountd 0.0 468 /usr/lib/ inet/inetd 0.0 458 hald-runn er 0.0 453 /usr/lib/ hal/hald 0.0 450 /usr/sbin /rpcbind 0.0 421 /usr/lib/ inet/proftpd 0.0 413 /usr/sbin /cron 0.0 382 /lib/svc/ method/iscsi d 0.0 369 /usr/lib/ efcode/sparc v9/efdaemon 0.0 332 /usr/sbin /nscd 0.0 297 /usr/lib/ picl/picld 0.0 272 /lib/inet /nwamd ...

  • Fujitsu M10-4S - page 514

    Table C-7 prstat(1M) co mman d option s Option Description Application No options Displays a list of pr ocesses sorted in descending order of C PU resource consum ption. T he list is restr icted by the height of the terminal window and the number of processes. The outp ut is automatically updated every 5 seco nds, and is stopped by press ing the [C ...

  • Fujitsu M10-4S - page 515

    Appendix D External Interface Specifications This appendix descri bes the specifications of the exter nal interface co nnectors an d the switch for the XSCF provided on the SPAR C M10-4/ M10-4S and the cross bar box. The externa l interface conn ectors provided on the SPAR C M 10-4/M1 0-4S are as follo ws. ■ Serial Port ■ USB Port ■ SAS Port ...

  • Fujitsu M10-4S - page 516

    Table D-1 Serial port Pin arrangement Pin number Signal name Input/Output Description 1 RTS Out put Trans mission request 2 DTR Output Data terminal ready 3 TXD Output Tr ansmitted d ata 4 GND --- Ground 5 GND --- Ground 6 RXD Input Receiv ed data 7 DSR In put Data set ready 8 CTS Input Transmission poss ible D.1.1 Wire connection chart for serial ...

  • Fujitsu M10-4S - page 517

    Table D-2 USB port Pin arrangement Pin number Signal name Input /Outpu t Descrip tion 1 VBUS Output Powe r supply 2 -DATA Input/ Output Data 3 +DATA In put/ Output Data 4 GND --- G round D.3 SAS Port The SAS po rt of the S PARC M 10-4/M1 0-4S is used to connect exter nal devices with an SAS interface, suc h as a tape drive. The ch assis has one SAS ...

  • Fujitsu M10-4S - page 518

    A A Figure D-2 RESET s witch loca tion (SPARC M10-4) Figure D-3 RESET s witch loca tion (SPARC M10-4S) Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual ・ December 2013 494 ...

  • Fujitsu M10-4S - page 519

    Index C cable kit , 425 cable, types of , 29 component list , 463 component specifications , 46 7 component s, names and loc ations o f , 11 CPU memory unit , 83 crossbar backplane unit , 343 crossbar cable (electrical) , 379 crossbar cable (optical) , 389 crossbar unit , 179 , 297 D dedicated power distribution u nit , 453 E emergenc y power off , ...

  • Fujitsu M10-4S - page 520

    X XSCF BB contro l cable , 401 XSCF DUAL con trol cable , 413 XSCF interf ace unit , 337 XSCF unit , 307 Fujitsu M10-4/Fujitsu M10-4S/SPARC M10-4/SPARC M10-4S Service Manual • December 2013 496 ...

Manufacturer Fujitsu Category Server

Documents that we receive from a manufacturer of a Fujitsu M10-4S can be divided into several groups. They are, among others:
- Fujitsu technical drawings
- M10-4S manuals
- Fujitsu product data sheets
- information booklets
- or energy labels Fujitsu M10-4S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Fujitsu M10-4S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Fujitsu M10-4S, service manual, brief instructions and user manuals Fujitsu M10-4S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Fujitsu M10-4S.

Similar manuals

A complete manual for the device Fujitsu M10-4S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Fujitsu M10-4S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Fujitsu M10-4S.

A complete Fujitsu manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Fujitsu M10-4S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Fujitsu M10-4S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Fujitsu M10-4S, that we can find in the current document
3. Tips how to use the basic functions of the device Fujitsu M10-4S - which should help us in our first steps of using Fujitsu M10-4S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Fujitsu M10-4S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Fujitsu M10-4S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Fujitsu M10-4S?

Use the form below

If you did not solve your problem by using a manual Fujitsu M10-4S, ask a question using the form below. If a user had a similar problem with Fujitsu M10-4S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)