  • Sharp AY-AP09DJ - page 3

    1 ENGLISH Thank you for purchasing a SHARP air conditioner. Please read this manual carefully before operating the product. • PRECAUTIONS .............................................. 1 • ADDITIONAL NOTES ON OPERATION ........ 3 • TIPS ON SAVING ENERGY ........................... 3 • PART NAMES ............................................. ...

  • Sharp AY-AP09DJ - page 4

    PRECAUTIONS CAUTIONS FOR USE 1 If a gas appliance is used in the same room as the air conditioner, ventilate the room periodically to prevent oxygen depletion. 2 For safety, do not touch the unit with wet hands, it may cause an electric shock. 3 For safety, turn the circuit breaker off when not using the unit for an extended period of time. 4 For s ...

  • Sharp AY-AP09DJ - page 5

    INDOOR TEMP. OUTDOOR TEMP. COOLING upper limit 32 ˚ C D.B. 46 ˚ C D.B. 23 ˚ C W.B. - lower limit 21 ˚ C D.B. 21 ˚ C D.B. 15 ˚ C W.B. - HEATING upper limit 27 ˚ C D.B. 24 ˚ C D.B. - 18 ˚ C W.B. lower limit 20 ˚ C D.B. -8.5 ˚ C D.B. - -9.5 ˚ C W.B. ADDITIONAL NOTES ON OPERA TION OPERATING TEMPERATURE RANGE • The built-in protective devi ...

  • Sharp AY-AP09DJ - page 6

    4 P ART NAMES 1 Inlet (Air) 2 Open Panel 3 Air Filters 4 AUX. Button 5 RECEIVER Window 6 Power Supply Cord 7 Indicator Panel 8 Vertical Adjustment Louvres 9 Horizontal Adjustment Louvres 0 Outlet (Air) q Remote Control w AUTO FAN SPEED Lamp (green ) e FAN SPEED Lamp (green ) r PLASMACLUSTER Lamp (blue, green) t TIMER Lamp (orange ) y OPERATION Lamp ...

  • Sharp AY-AP09DJ - page 7

    REMOTE CONTROL 1 TRANSMITTER 2 DISPLAY (Liquid Crystal Display) 3 ON/OFF Button 4 THERMO. (Thermostat) Button 5 DISPLAY Button 6 MODE Button 7 TIMER ON Button (for setting the timer) 8 ONE-HOUR OFF TIMER Button 9 TIMER OFF Button (for setting the timer) 0 FAN Button q TIMER CANCEL Button w SWING Button e PLASMACLUSTER Button 5 r MODE SYMBOLS : AUTO ...

  • Sharp AY-AP09DJ - page 8

    CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal. • The ...

  • Sharp AY-AP09DJ - page 9

    7 TIPS ABOUT PLASMACLUSTER OPERA TION AIR CLEAN OPERATION Cluster ions released into the air will reduce airborne mold fungus. ION BALANCE OPERATION It is said that plenty of negative ions exist in places such as waterfalls or watreside in natural environment. In this operation mode, negative ions will be released in an increased rate, in order to ...

  • Sharp AY-AP09DJ - page 10

    Press the THERMO. button to set the desired temperature. AUTO/DRY MODE The temperature can be changed in 1°C in- crements within the range of 2°C higher to 2°C lower from the tem- perature automatically determined by the air conditioner. COOL/HEAT MODE The temperature can be set within the range of 18 to 32°C. FAN ONLY MODE The temperature set- ...

  • Sharp AY-AP09DJ - page 11

    9 Automatic Operation Mode Thermostat Setting Below 21°C HEAT 23°C 21°C-24°C DRY Room Temp. at start-up 24°C-26°C COOL 24°C 26°C-28°C COOL 25°C Above 28°C COOL 26°C TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature when the unit is turned on. Modes and Te ...

  • Sharp AY-AP09DJ - page 12

    COOL and DRY mode Horizontal air flow HEAT and FAN ONLY mode Diagonal air flow 10 ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION The air flow direction is automatically preset in each mode as follows for optimum comfort: HOW TO ADJUST THE AIR FLOW DIRECTION COOL and DRY mode HEAT and FAN ONLY mode The adjustment range is narrow in ord ...

  • Sharp AY-AP09DJ - page 13

    11 1 Press the ONE-HOUR OFF TIMER button. • The remote control displays “ ”. • The orange TIMER lamp ( ) on the unit will light up. • The unit will stop operating after one hour. TO CANCEL Press the CANCEL button. • The orange TIMER lamp ( ) on the unit will turn off. Or, turn the unit off by pressing the ON/OFF button. • The red OPER ...

  • Sharp AY-AP09DJ - page 14

    12 The unit will turn off automatically according to your setting. Timer duration can be set from minimum 0.5 hours (30 minutes) to maximum 12 hours. Up to 9.5 hours, you can set by 0.5 hours (30 minutes) increments and from 10 to 12 hours, by 1 hour increment. TIMER OPERA TION TIMER OFF When the TIMER OFF is set, the temperature setting is automat ...

  • Sharp AY-AP09DJ - page 15

    13 1 TIMER ON NOTES FOR TIMER SETTING AND OPERATION • The latest time setting will be memorized and will appear on the remote control display the next time you set the TIMER OFF or TIMER ON. • TIMER OFF and TIMER ON can not be set together. The latest set TIMER will be active. • When ONE-HOUR OFF TIMER is set, TIMER OFF and TIMER ON will not ...

  • Sharp AY-AP09DJ - page 16

    AUXILIAR Y MODE Use this mode when the remote control is not available. TO TURN ON Lift the front panel of the indoor unit and press the AUX. button on the operation panel. • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode. • The fan speed and temperature setting are set to AUTO. TO TURN OFF ...

  • Sharp AY-AP09DJ - page 17

    15 CLEANING THE UNIT AND THE REMOTE CONTROL • Wipe them with a soft cloth. • Do not directly splash or pour water on them. It can cause electrical shock or damage. • Do not use hot water, thinner, abrasive powders or strong solvents. CLEANING THE FIL TERS MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Operate the unit in the FAN ONLY mode for abo ...

  • Sharp AY-AP09DJ - page 18

    IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL Check whether the remote control batteries have be- come old and weak. Try to send the signal again with the remote control pointed properly towards the unit’s signal receiver window. Check whether the remote control batteries are in- stalled with the polarities properly aligned. 16 BEFORE CA ...

  • Sharp AY-AP09DJ - page 19

    17 SPECIFICA TIONS Indoor unit AY-AP09DJ Outdoor unit AE-A09DJ Rated A.C. voltage (V) 230-240 Rated freuency (Hz) 50 Cooling capacity (kW)* 2.5 Heating capacity (kW)* 3.0 *When tested in accordance with AS/NZS3823.1.1. ...

  • Sharp AY-AP09DJ - page 20

    SHARP CORPORA TION OSAKA, JAPAN TINSEA359JBRZ 03HO TH 1 Printed in Thailand ...

Manufacturer Sharp Category Air Conditioner

Documents that we receive from a manufacturer of a Sharp AY-AP09DJ can be divided into several groups. They are, among others:
- Sharp technical drawings
- AY-AP09DJ manuals
- Sharp product data sheets
- information booklets
- or energy labels Sharp AY-AP09DJ
All of them are important, but the most important information from the point of view of use of the device are in the user manual Sharp AY-AP09DJ.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Sharp AY-AP09DJ, service manual, brief instructions and user manuals Sharp AY-AP09DJ. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Sharp AY-AP09DJ.

Similar manuals

A complete manual for the device Sharp AY-AP09DJ, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Sharp AY-AP09DJ by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Sharp AY-AP09DJ.

A complete Sharp manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Sharp AY-AP09DJ - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Sharp AY-AP09DJ, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Sharp AY-AP09DJ, that we can find in the current document
3. Tips how to use the basic functions of the device Sharp AY-AP09DJ - which should help us in our first steps of using Sharp AY-AP09DJ
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Sharp AY-AP09DJ
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Sharp AY-AP09DJ in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Sharp AY-AP09DJ?

Use the form below

If you did not solve your problem by using a manual Sharp AY-AP09DJ, ask a question using the form below. If a user had a similar problem with Sharp AY-AP09DJ it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)