    RealScan 7883 Inst allation and Owner Guide 12623 497-0424789 Release F April 2004 Information Products RSD-Atlanta ...

  • NCR 7883 - page 2

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 2 of 75 The program products described in th is book ar e licensed prod ucts of NCR Corporation. It is the policy of NCR to improve pr oducts as ne w technol ogy, com ponents, soft ware, and firm ware become available. Therefore , NCR reserves the right to cha nge specificat ...

  • NCR 7883 - page 3

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 3 of 75 NCR Compone nts ........................................................................................................ 39 METTLER TOLEDO Com ponents ............................................................................. 40 Sensormatic Com ponents ........... ...

  • NCR 7883 - page 4

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 4 of 75 Hex E .......................................................................................................................... .7 5 Hex F .......................................................................................................................... .7 5 ...

  • NCR 7883 - page 5

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 5 of 75 Obt aining Additional Information Other Information Pro ducts Order Number Title B005-0000-1436 NCR RealScan 7883 User Gui de B005-0000-1437 NCR RealScan 7883 R epair Guide BST0-2121-74 NCR Scanner Progra mming Tags BD20-1074-A NCR Scanner/Scal e Interface Programmer ...

  • NCR 7883 - page 6

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 6 of 75 NCR RealScan 7883 Mountings The NCR RealScan 7883 Scanne r is a small, compact laser s canner availabl e in two model s . The RealScan 7883-1000 has many of the same features fou nd in larger scanners. The RealScan 7883-1200 has the same capabilities as the 788 3-100 ...

  • NCR 7883 - page 7

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 7 of 75 Inst allation Instructions When installing a RealScan 7883 , it is recommended that you first mount the Power Supply an d run all the cables. After connecting the unit to the host terminal, make any necessary program ming changes and scan som e good tags to verify th ...

  • NCR 7883 - page 8

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 8 of 75 S tep 1 - Inst alling Power Supply and Interface Cables Connecting the Cables to an NCR RealScan 7883 The NCR RealScan 7883 is po wered through an extern al Power Supply. An interface cable connects the RealScan 7883 to the host term inal. Two RS- 232 peripheral port ...

  • NCR 7883 - page 9

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 9 of 75 7883-1000 USB Interface Connection Connecting a RealScan 7883-1000 Scan ner to a USB port on a host terminal requires a special cab le. One end of the Dongle Adapter Cable connec ts to the host term inal. The other end has an Interf ace Box that contains a printed ci ...

  • NCR 7883 - page 10

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 10 of 75 J3 in the Interface Box on the end of the Dongle Adapte r Cable contains a shunt th at must be correctly installed for the host term inal. The cable is shipped from the factory with a shunt on pins 3 and 4. The following four posi tions are available. • Pins 1 &am ...

  • NCR 7883 - page 11

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 11 of 75 For connecting to IBM and NCR terminals a latchin g or USB Plus Power cable should be used. 1416-C895-0050 - Cab le - USB IBM, Latching For connecting to PC’s, non -NCR/IBM terminals and N CR term inals without the USB Plus Power connector use cable below. 1416-C8 ...

  • NCR 7883 - page 12

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 12 of 75 Special Installations RS-232 Peripherals The RealScan 7883 includes two auxiliary RS-232 ports. This permits other peripheral dev ices to connect to the host terminal through th e RealScan 7883, eliminating the need of the host terminal h aving additional RS-23 2 po ...

  • NCR 7883 - page 13

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 13 of 75 the RealScan 7883. Programming the RealScan 7892 Set the RealScan 7892 commun ication parameters to match th e requirements of the RealScan 7883 auxiliary port. 7892 Programmin g requirements ar e provided below: From standar d R S-2 3 2 protocol 2 0 5 4 1 5 9600 ba ...

  • NCR 7883 - page 14

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 14 of 75 1. FACTORY DEFAULT 2. RS232, 7 DATA, 1 STOP, SPACE PARITY 3. Prefixes / Code 39 - a, Code 128 - f, Code I 2of 5 - b 1. Default Data Format 2. UPC-A Prefix A 3. UPC-E Prefix E 4. EAN 13 Prefix F 5. EAN 8 Prefix FF ...

  • NCR 7883 - page 15

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 15 of 75 S tep 2 - Setting Program Parameters and V e rifying Host Connection Now you need to tu rn on the NCR RealS can 7 883. First loa d new firmwar e if needed t hen make any necessary prog ram changes. Next scan a fe w tags to verify that t he R ealScan 7883 is communic ...

  • NCR 7883 - page 16

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 16 of 75 Programming Defaults Scanning the Default pr ogramm ing tag sets m ost program param eters to the default program med at the factory . The original define d default value s are shown in the cha rt bel o w. However, som e paramete rs do not have default values so the ...

  • NCR 7883 - page 17

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 17 of 75 18 Bar Codes – 5 RSS Enable Disable Scans Required On RSS 14 1 Scans Required On RSS E 1 UCC1128 Emulation Mode Normal Mode 16 Label Identifiers Identifier Type Default Prefix Common Byte 1 5D Common Byte 2 42 Bar Code Type No Default value – remain s as program ...

  • NCR 7883 - page 18

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 18 of 75 Programming for USB Connection The RealScan 788 3 Scanner m ust be properly programm ed for USB. Program ming and cabl ing depends on whether t he unit is a 7883-1000 or 788 3-1200. The 7883-1000 uses the U SB Dongle connection to the host terminal while the 788 3- ...

  • NCR 7883 - page 19

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 19 of 75 3. Hex 1 , Hex 0 , Hex D - sets the communication protocol to IBM USB. 4. Hex 4 , Hex 8 , Hex 5 – turns off configuration me ssage processing. 5. Change any o ther parameters as required by the host terminal. 6. Save and Res et – saves the parameters just entere ...

  • NCR 7883 - page 20

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 20 of 75 19257 0192 1234 5698 7457 3202 0000 9939 0200 296 Enabling RSS 1. Turn on the circuit breaker to the RealScan 7883. 2. Enable the Reduced Space Symbology fe ature by scanning the following sequence of programming tags. These must be the fi rst tags scanned after app ...

  • NCR 7883 - page 21

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 21 of 75 Scan Sample Tags Now you should scan some sample tags to verify that the RealScan 7883 is communicating with the host terminal. Following are four good tag s that you can use. After verifying that the RealScan 7883 is communicating properly with the host terminal, c ...

  • NCR 7883 - page 22

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 22 of 75 Determining Label Quality Many labels in a typical retail environ ment are unreadab le. The following illustratio n shows some of the common problem s. Vendors and printers re gularly s upply pro ducts to the market wi th bar codes that are ove rprinted, u nderprint ...

  • NCR 7883 - page 23

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 23 of 75 S tep 3 - Setting RealScan 7883 Scan Zone The scan zone on a NCR RealScan 7883 Scanner ca n be set to horizo ntal or vertical . Changi ng the scan zone changes t he angle of the scan lines coming from the scanner. 16011 Horizontal Scanning Vertical Scanning You chan ...

  • NCR 7883 - page 24

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 24 of 75 Horizontal - Pass-by Scanning This installation provides the most efficient way to scan items. It is typically used in checkouts where speed is extremely important. In this installation, the op erator slides items from the input area on the check stand, across the s ...

  • NCR 7883 - page 25

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 25 of 75 Vertical - Presentation Scanning from Top This installat ion is use d on small checkout cou nt ers that do not have enoug h r oom for pass-by scannin g. He re the operator picks up the item, presents it toward th e top of the scanner, and then bags the item all in o ...

  • NCR 7883 - page 26

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 26 of 75 S tep 4 - Mounting the RealScan 7883 The RealScan 788 3 can sit vert ically on the checkstand, be m ounted vertic ally in a Verti cal Mounting B racket, or be mounted ho rizontally i n the checkstand. If it is m ounted horizonta lly in the chec kstand, it must be fa ...

  • NCR 7883 - page 27

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 27 of 75 3. Install two L atch Clips – horizontal installation only . These clips secure the RealScan 7883 to the Plastic Top Plate in case something falls on the assembled unit. D C Plastic Top Plate Latch Clip 19771 Scanner Mounting Screw ...

  • NCR 7883 - page 28

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 28 of 75 Vertical Mounting Bracket Laser Scan Direction Laser Scan Direction Laser Scan Direction Vertical Moun t Brac ke t Scanner Interface Cable Power Cable Mounting Screws (Three) Ground Wire 16016 RS-232 Periph eral Cable ...

  • NCR 7883 - page 29

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 29 of 75 Checkstand Cutout 1. Put the RealScan 7883 i nto the hole in the checkstand. Diagrams in NCR RealScan 7883 Specifications show the various dime nsions of the hole. 2. Align the RealScan 7883 to the Checkstand . The leading edge of the Top Plate must be flush or up t ...

  • NCR 7883 - page 30

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 30 of 75 Operating the Scanner The NCR RealScan 7883 is a fixed position device that is not handled or moved by the operator during operation. It is maintained and serviced by trai ned se rvice personnel only. The ope rator has no access to a ny laser module components. The ...

  • NCR 7883 - page 31

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 31 of 75 Cleaning the Scanner Keeping the scan window s clean helps keep the r ead rate exception a lly high . During normal oper ation the scan windows get dirty, an d if you perm it the dirt t o accumulat e, perform a nce degrades to the point wher e the scanner cannot rea ...

  • NCR 7883 - page 32

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 32 of 75 Correcting Scanner Problems When the Real Scan 7883 is fi rst turned o n, several diagn ostic tests are r un to check t he status of va rious com ponents. If a failure occurs, a series of beeps an d flas hes of the Gree n St at us Indi cat or identi fy it . The num ...

  • NCR 7883 - page 33

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 33 of 75 There are other conditions that are not iden tified by the diag nostics when you turn on the RealScan 7883. The following chart identifies some of th e more comm on problem s. Problem Status Indicators Tone Possible Cause Corrective Action Scanner does not operate R ...

  • NCR 7883 - page 34

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 34 of 75 Interface Information Interface Connector 20151 10 1 1 2 3 4 5 6 7 8 9 10 NC NC NC NC NC NC TMPWR TRA TRB GND DSR (IN) DTR (OUT) TXD (OUT) RTS (OUT) CTS (IN) RXD (IN) NC NC NC GND NC KBCLK/ NC NC NC NC PCCLK/ PCDATA/ Pin IBM RS-232 WEDGE Ground Lug Complies with FD ...

  • NCR 7883 - page 35

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 35 of 75 Communications Protocol The Comm unications Protoc ol function identifies the communi cations protoc ol the RealScan 7 883 is using. Sca n the Diagnostics Mode and Hex 3 pro gramming t ags (must be first tags sca nned afte r applyin g power). T hree beeps so und aft ...

  • NCR 7883 - page 36

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 36 of 75 NCR RealScan 7883 Specif ications Checkstand Hole – RealScan 7883 Horizontal Mount 11981 E SIDE VIEW C Item Flow D C D E A BC D E 8 5/8 in. 21.91 cm 8 5/8 in. 21.91 cm 1/16 in. 0.16 cm 1 1/16 in. 2.70 cm 1/2 in. 1.27 cm Features F062 9 5/8 in. 24.45 cm 11 5/16 in. ...

  • NCR 7883 - page 37

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 37 of 75 Checkstand Hole – RealScan 7883 Flat Mount 11993 SIDE VIEW AB C D Features 8 3/4 in. 22.22 cm 8 3/4 in. 22.22 cm 1/16 in. 0.16 cm 1/16 in. 0.16 cm K012 A B C Item Flow D C B D Ventilation Requirements The NCR RealScan 7883 is designed to operate without an exhaust ...

  • NCR 7883 - page 38

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 38 of 75 Electrical Wiring Feeder wiring and insulated ground from main service panel to distribution panel to be run in metal conduit. The electrical wiring must meet all electrical codes, laws, and regulations. Note: Circuit Breakers NCR circuits should be run in separate ...

  • NCR 7883 - page 39

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 39 of 75 NCR RealScan 7883, METTLER T OLEDO ® Scale, & Sensormatic ScanMax TM HS 20203 The NCR RealScan 7883, METTLER T OLEDO ® 8217AS, & Sensormatic ScanMax TM HS system is composed of components fr om three companies. NCR m anufactures the scanner, METTLER T OLED ...

  • NCR 7883 - page 40

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 40 of 75 METTLER TOLEDO Components 20206 Bridge Plate Top Plate Mounting Bracket With Scale Attached Sensormatic Components 20207 Controll er Box Deac tiva tion Brick Key Switch Alarm Box AC Pow er Cord ...

  • NCR 7883 - page 41

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 41 of 75 System Construction The NCR RealScan 7883, METTLER T OLEDO ® Scale, & ScanMax TM HS system can be constructed for right-to-left scanning or for left-to-right scanni ng. This is accomplished th rough the orientation of the Br idge Plate within the scale unit. Ri ...

  • NCR 7883 - page 42

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 42 of 75 Configuring the Scale First determine if the system needs to be configured for scann ing from right -to-left or from le ft-to-right. Install the Bridge Plate on the scale unit inside t he Mounting Bracket accordingly. Right-To-Left 20210 Left-To-Right 20211 ...

  • NCR 7883 - page 43

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 43 of 75 Installing the Scanner 1. Using the Velcro Strips provided by NCR, attach the Key Switch Alarm Box to the RealScan 7883 as shown. Note: The top of the Key Switch Alarm Box must be below the top of the RealScan 7883. Refer to the illustrations under Configuring the S ...

  • NCR 7883 - page 44

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 44 of 75 Connecting Sensormatic Components 1. Position the Deactivation Brick on top of the Bridge Plate as shown under Configuring the Scale . The cable from the Deactivation Brick must be routed from the bottom of the brick toward the center of the Bridge Plate. 20214 Deac ...

  • NCR 7883 - page 45

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 45 of 75 Routing the Cables How the cabl es are routed depends on t he configurati on, right -to- left or left-to-rig ht scanning. In either case the cables are held in place with a cable clam p attached to the Bridge Plate. Right-To-Left Scanning Customer End 20216 Checkout ...

  • NCR 7883 - page 46

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 46 of 75 Left-To-Right Scanning Customer End 20218 Checkout System End 20219 Completing the Installation Position the unit insid e th e cutout in the self-checkout termin al. Th en install the Top Plate. The To p Plate must positioned correctly for the type o f scanning. Ref ...

  • NCR 7883 - page 47

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 47 of 75 Calibrating the METTLER TOLEDO ® Scale Before proceeding make sure t he scanner is c onfigured for a scale. The programm ing tag sequence below. If speech is enabled, the 7883-1200 will sp eak that the Scale Failed if the scale is not connected or not calibrated an ...

  • NCR 7883 - page 48

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 48 of 75 5. Depress the Zero Scale button or scan th e Reset Sc ale tag. Two short beeps per second start to sound . 6. Place 20 p ounds (or 10kg) on the Top Plate. 7. Depress the Zero Scale button or scan the Re set Scale tag. One long beep per second starts to sound. 8. Re ...

  • NCR 7883 - page 49

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 49 of 75 Sensormatic Deactivation Indicators The Key Switch Alarm Box t hat is fastened to the RealScan 7 883 with V elcro strips, contains two i ndicators to indi cate the status of the unit. • Solid Green – Unit h as received an interl ock signal. • Flashing Green ? ...

  • NCR 7883 - page 50

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 50 of 75 Troubleshooting For the most part, the functi on of each of the three units; scanner, scale, and deactivation unit; work independently from each other. Howeve r, there are some inter actions. Following a re some basic things to che ck if the system is not working pr ...

  • NCR 7883 - page 51

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 51 of 75 Position 1 Down Position 2 – 8 Up for 30.00 l b, Only position 3 Down for 15.000 kg Sensormatic Deac tivation If the Sensormatic deactivation is not work ing , check the follo wing. • Controller Box Power Cable connections. • Scanner Power Cable connections. ? ...

  • NCR 7883 - page 52

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 52 of 75 Programming W orksheet s 10 Communications Protocol 20552 Protoc ol IBM Slot Scanner 3 IBM Hand-Held Bar Code Reader 4 RS-232 5 IBM 1520 Bar Code Reader B IBM USB D NCR (RS-232) USB E 0 7883-1200 only 11 Good Read Tone Tone On/Off A Off Tone Frequency (Hertz) Tone V ...

  • NCR 7883 - page 53

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 53 of 75 12 Timers R0136 NOTE: NCR suggests that you do not set the Active Time parameter to 0. Leaving the laser light on all the time reduces its life expectancy. Lockout Time (Milliseconds) A 350 8 450 0 600 1 750 2 900 3 1050 4 1200 5 1350 6 1500 7 Restart Lockout Time r ...

  • NCR 7883 - page 54

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 54 of 75 14 Bar Codes - 2 Code 39 A 0 Disable 1 Enable Minimum Characters Allowed B 8 2 - F De fault Full ASCII C 0 Disable 1 Enable Check Digit Present D 0 Disable 1 Enable Transmit Check Digit E 0 Disable 1 Enable Allow 1- or 2-Charac ter Tags F 0 Disable 1 Enable 20241-A ...

  • NCR 7883 - page 55

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 55 of 75 15 Bar Codes - 3 Interleaved 2 of 5 Bar Code Length Check Digit Present Transmit Check Digit Value 1 Characters Minimum Default: Value 2 Characters Maximum A B C D 0 8 Default: 1 6 0 Disable 1 Enable 0 Range Check Specif ic Check 0 - 3 Character 1 0 - 9 Character 2 ...

  • NCR 7883 - page 56

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 56 of 75 18 Bar Codes – 5 20596 RSS Enable Scans Required On RS S 14 B A Disable 0 Enable RSS 14 Only 1 1 Scan 1 2 Scans 2 3 Scans 3 4 Scans 4 Enable RSS E Only 2 Enable RSS 14 & RSS E 3 Scans Required On RS S E C 1 Scan 1 2 Scans 2 3 Scans 3 4 Scans 4 UCC-128 Emulatio ...

  • NCR 7883 - page 57

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 57 of 75 20 RS-232 Parameters - 1 Baud Rate A 0 300 1 600 2 1200 3 2400 4 4800 5 9600 6 19200 Parity B Stop Bit s And Character Length C Handshake D 0 Odd 1 Even 4 None 0 1 Stop Bit 7-Bit Character 1 1 Stop Bit 8-Bit Character 2 2 Stop Bits 7-Bit Character 3 2 Stop Bits 8-Bi ...

  • NCR 7883 - page 58

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 58 of 75 22 RS-232 Prefix Byte Prefix Byt e A ASCII Code B 0 Disable 1 Enable 0 - 7 Hex Charac te r (ASCII Code Chart) 0 - F Hex Character (ASCII Code Chart) 0 Default 2 20247-A 23 RS-232 Terminator Byte Terminator Byte A ASCII Code B 0 Disable 1 Enable 0 - 7 Hex Charac te r ...

  • NCR 7883 - page 59

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 59 of 75 32 Miscellaneous Parameters – RealScan 7883-1000 IBM Tone Control (Good Read Tone Control) IBM Rexmit Control IBM Tag Data For mat Disable 3 Enable 4 3 Times 7 Forever 8 Hex E ASCII F 20250A 32 Miscellaneous Parameters – RealScan 7883-1200 20557 IBM Tone Control ...

  • NCR 7883 - page 60

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 60 of 75 ASCII Code Chart 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F p q r s t u v w x y z { | } DEL 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F a b c d e f g h i j k l m n o 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F P Q R S T U V W X Y Z [ ] ^ _ 40 41 42 43 ...

  • NCR 7883 - page 61

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 61 of 75 Regulatory Information Federal Communications Commission (FCC) Radio Frequency Interference Statement Note: This equipment has been tested and found to comply with the limits for a Class A digital dev ice, pursuant to Part 15 of the FCC Rul es. These lim its are des ...

  • NCR 7883 - page 62

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 62 of 75 19763 NCR Corporation Duluth , Ga. 30096 Complies w ith FDA radi ation Performance standards 21 CFR Subcha pter J. One or more of the U.S. Patents listed below apply: 4,868,375 4,797,551 4,851,667 4,235,018 4,272,675 4,282,426, 4,679,154 5,194,722 5,276,316 5,334,82 ...

  • NCR 7883 - page 63

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 63 of 75 Declaration of Conformity We, NCR Corporat ion , Retail Solutions Division Atlanta, 2 651 Satellite Bou levard, Duluth, Geo rgia, 30096-5810, U.S.A., declare under our sole responsibility that the product NCR RealScan 7883 Bar Code Scanner to which this declaration ...

  • NCR 7883 - page 64

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 64 of 75 Laser Safety The NCR RealScan 7883 is not in tend ed for long-term viewing of the direct la ser light. However, the unit is safe if used as it was intended. Note: The NCR RealScan 7883 is a CDRH Class IIa and IEC Class 1 Laser Produc t Laser Safety Label 18546 (IEC ...

  • NCR 7883 - page 65

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 65 of 75 Laser Power The NCR RealScan 7883 meets the following laser power requ irements. • Class 1 EN 608 25-1: 1994 (Europäische Norm) • Class 1 IEC 825-1 : 1993 (Interna tional Electrotechnical Commissi on) • Class IIA CDRH (Center for Devices an d Radiological Hea ...

  • NCR 7883 - page 66

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 66 of 75 Programming T ags Volume Adjustment 11817 Reset 11818 Default R0046 ...

  • NCR 7883 - page 67

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 67 of 75 Programming Mode R0042 End R0043 Save and Reset R0044 ...

  • NCR 7883 - page 68

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 68 of 75 Abort R0045 Diagnostic Mode R0041 RS-232 Temporary Service Mode 16576 ...

  • NCR 7883 - page 69

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 69 of 75 Mode 1 11500 Mode 2 11501 Reset Tallies 11502 ...

  • NCR 7883 - page 70

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 70 of 75 Firmware Flashing Super ASIC Mo d el s 20600 Hex 0 R0048 Hex 1 R0049 ...

  • NCR 7883 - page 71

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 71 of 75 Hex 2 R0050 Hex 3 R0051 Hex 4 R0052 ...

  • NCR 7883 - page 72

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 72 of 75 Hex 5 R0053 Hex 6 R0054 Hex 7 R0055 ...

  • NCR 7883 - page 73

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 73 of 75 Hex 8 R0056 Hex 9 R0057 Hex A R0058 ...

  • NCR 7883 - page 74

    NCR RealScan 7883 Installation and Owner Guide 04/04 497-0424789 Release F 74 of 75 Hex B R0059 Hex C R0060 Hex D R0061 ...

  • NCR 7883 - page 75

    NCR RealScan 7883 Installation and Owner Guide 497-0424789 Release F 04/04 75 of 75 Hex E R0062 Hex F R0063 Copyright © 2003 by NCR Corporation ...

Manufacturer NCR Category All in One Printer

Documents that we receive from a manufacturer of a NCR 7883 can be divided into several groups. They are, among others:
- NCR technical drawings
- 7883 manuals
- NCR product data sheets
- information booklets
- or energy labels NCR 7883
All of them are important, but the most important information from the point of view of use of the device are in the user manual NCR 7883.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals NCR 7883, service manual, brief instructions and user manuals NCR 7883. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product NCR 7883.

Similar manuals

A complete manual for the device NCR 7883, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use NCR 7883 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of NCR 7883.

A complete NCR manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual NCR 7883 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the NCR 7883, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the NCR 7883, that we can find in the current document
3. Tips how to use the basic functions of the device NCR 7883 - which should help us in our first steps of using NCR 7883
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with NCR 7883
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of NCR 7883 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning NCR 7883?

Use the form below

If you did not solve your problem by using a manual NCR 7883, ask a question using the form below. If a user had a similar problem with NCR 7883 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)