Manual Black Box IEEE 1284

15 pages 0.41 mb
Download

Go to site of 15

Summary
  • Black Box IEEE 1284 - page 1

    AUGUST 1999 PI049A IEEE 1284 Serial to Parallel Con verter IEEE 1284 Serial to Parallel Converter CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500 ) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: Black Box Corporation , 1000 Park ...

  • Black Box IEEE 1284 - page 2

    1 IEEE 1284 SERIAL TO P ARALLEL CONVER TER TRADEMARKS USED IN THIS MANUAL Centronics is a registered trademark of Centronics Corporation. DEC is a trademark of Digital Equipment Corporation. Hewlett-Packard and LaserJet are registered trademarks of Hewlett-Packard. Any other trademarks used in this manual are acknowledged to be the property of the ...

  • Black Box IEEE 1284 - page 3

    2 IEEE 1284 SERIAL TO P ARALLEL CONVER TER FEDERAL COMMUNICA TIONS COMMISSION AND CANADIAN DEP AR TMENT OF COMMUNICA TIONS RADIO FREQUENCY INTERFERENCE ST A TEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may ...

  • Black Box IEEE 1284 - page 4

    3 IEEE 1284 SERIAL TO P ARALLEL CONVER TER NORMAS OFICIALES MEXICANAS (NOM) ELECTRICAL SAFETY ST A TEMENT INSTRUCCIONES DE SEGURIDAD 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3 ...

  • Black Box IEEE 1284 - page 5

    4 IEEE 1284 SERIAL TO P ARALLEL CONVER TER 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contacto ...

  • Black Box IEEE 1284 - page 6

    5 IEEE 1284 SERIAL TO P ARALLEL CONVER TER CE Notice The CE symbol on your IEEE 1284 Serial to Parallel Converter indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). ...

  • Black Box IEEE 1284 - page 7

    6 IEEE 1284 SERIAL TO P ARALLEL CONVER TER Contents Chapter Page 1. Specifications ......................................................................................................7 2. Introduction ........................................................................................................8 2.1 Description ......................... ...

  • Black Box IEEE 1284 - page 8

    7 IEEE 1284 SERIAL TO P ARALLEL CONVER TER 1. Specifications Transmission Format— Serial side: Asynchronous, full duplex; Parallel side: IEEE 1284 BiTronics, supporting Compatibility and Nibble Modes (switchable) Data Rates— 9.6, 19.2, 38.4, and 115.2 kbps Range— Meets capacitive and resistive load requirements of RS-232 and RS-423 ESD Protec ...

  • Black Box IEEE 1284 - page 9

    8 IEEE 1284 SERIAL TO P ARALLEL CONVER TER 2. Introduction 2.1 Description The IEEE 1284 Serial to Parallel Converter lets you connect RS-232/423 serial hardware to a printer or other device equipped with a BiTronics parallel interface. Able to work in either Level 1 Compatible or Nibble modes (according to the IEEE 1284 standard), the Converter su ...

  • Black Box IEEE 1284 - page 10

    9 IEEE 1284 SERIAL TO P ARALLEL CONVER TER 3. Configuration 3.1 Configuration Switches The Converter uses a set of eight external DIP switches that allow configuration to a wide range of applications. Because all eight switches are in one externally accessible DIP-switch package, there is no need to open the case for configuration. The configuratio ...

  • Black Box IEEE 1284 - page 11

    10 IEEE 1284 SERIAL TO P ARALLEL CONVER TER S WITCH 2: R EVERSE F LOW C ONTROL The setting for Switch 2 determines whether the serial device receives reverse flow control information from the printer (see IEEE 1284 specification for details on reverse flow control). Reverse Flow Control SW2 Hardware (Nibble) OFF (factory default) None (Compatible) ...

  • Black Box IEEE 1284 - page 12

    11 IEEE 1284 SERIAL TO P ARALLEL CONVER TER 4. Installation Once you have configured the Converter, follow these installation instructions. 1. Plug the Converter directly into the 36-pin Centronics ® interface. Where necessary, a short (no more than 6 ft. or 1.8 m) parallel printer cable may be used. 2. The RS-232 interface is wired as a DCE (see ...

  • Black Box IEEE 1284 - page 13

    12 IEEE 1284 SERIAL TO P ARALLEL CONVER TER 5. Operation Once the Converter is properly configured and installed, it should operate transparently—as if it were a standard cable connection. There is no ON/OFF switch. LED Status Monitors The Converter features two easy-to-read status LEDs. The green LED glows when optional AC power (from the option ...

  • Black Box IEEE 1284 - page 14

    13 IEEE 1284 SERIAL TO P ARALLEL CONVER TER Appendix: Inter face Connections 36-Pin Centronics Parallel Port Connections Pin Description Direction 1 Strobe Output 2 Data bit 0 3 Data bit 1 4 Data bit 2 5 Data bit 3 6 Data bit 4 7 Data bit 5 8 Data bit 6 9 Data bit 7 10 Acknowledge Input (active low) 11 Busy Input (active high) 12 Paper end 13 Selec ...

  • Black Box IEEE 1284 - page 15

    1000 Park Drive • Lawrence, PA 15055-1018 • 724-746-5500 • Fax 724-746-0746 © Copyright 1999. Black Box Corporation. All rights reserved. ...

Manufacturer Black Box Category Network Card

Documents that we receive from a manufacturer of a Black Box IEEE 1284 can be divided into several groups. They are, among others:
- Black Box technical drawings
- IEEE 1284 manuals
- Black Box product data sheets
- information booklets
- or energy labels Black Box IEEE 1284
All of them are important, but the most important information from the point of view of use of the device are in the user manual Black Box IEEE 1284.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Black Box IEEE 1284, service manual, brief instructions and user manuals Black Box IEEE 1284. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Black Box IEEE 1284.

Similar manuals

A complete manual for the device Black Box IEEE 1284, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Black Box IEEE 1284 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Black Box IEEE 1284.

A complete Black Box manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Black Box IEEE 1284 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Black Box IEEE 1284, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Black Box IEEE 1284, that we can find in the current document
3. Tips how to use the basic functions of the device Black Box IEEE 1284 - which should help us in our first steps of using Black Box IEEE 1284
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Black Box IEEE 1284
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Black Box IEEE 1284 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Black Box IEEE 1284?

Use the form below

If you did not solve your problem by using a manual Black Box IEEE 1284, ask a question using the form below. If a user had a similar problem with Black Box IEEE 1284 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)