Manual Dayton 3E359B

24 pages 0.51 mb
Download

Go to site of 24

Summary
  • Dayton 3E359B - page 1

    Operating Instructions & Parts Manual Dayton Portable Oil-Fir ed Heaters ® Form 5S2514 Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the pr oduct described. Protect yourself and others by observing all safety information. Failur e to comply with instructions could result in ...

  • Dayton 3E359B - page 2

    Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Upper Shell Fuel Cap Thermostat Fuel T ank Power Cord Lower Shell Motor and Pump Assembly Hot Air Outlet Lower Shell Fuel Cap Thermostat Upper Shell Fuel T ank Power Cord Flame-Out Control Reset Button Motor and Pump Assembly Flame-Out Control R ...

  • Dayton 3E359B - page 3

    Dayton Operating Instructions and Parts Manual 3 ® Models 3E358B and 3E359B General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater . Safety information appears throughout these instructions. Pay close attention to them. Bel ...

  • Dayton 3E359B - page 4

    Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B General Safety Information (Continued) THEOR Y OF OPERA TION THE FUEL SYSTEM The motor turns the fuel pump. The fuel pump pulls fuel from the fuel tank. The fuel pump pushes fuel through a filter and a solenoid valve and out the burner head nozz ...

  • Dayton 3E359B - page 5

    Dayton Operating Instructions and Parts Manual 5 ® Models 3E358B and 3E359B Follow the mini- mum fresh, outside air ventilation requir ements. If proper fresh, outside air ventilation is not provided, carbon monoxide poisoning can occur . Provide proper fr esh, outside air ventilation before running heater . FRESH AIR OPENING REQUIREMENTS Square F ...

  • Dayton 3E359B - page 6

    Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Operation (Continued) TO STOP HEA TER Never unplug heater while heater is running. Heater must go through purge cycle. The purge cycle cools the combustion chamber . Damage to heater can occur if combustion chamber is not cooled. Do not restart ...

  • Dayton 3E359B - page 7

    Dayton Operating Instructions and Parts Manual 7 ® Models 3E358B and 3E359B Figure 8 - Upper Shell Removal, Model 3E359B Upper Shell Maintenance Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur . UPPER SHELL REMOV AL 1. Remove screws along each side and top of heater using 5/16" nut-d ...

  • Dayton 3E359B - page 8

    Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Fuel Filter Pump Cover Figure 13 - Fuel Pump and Filter Figure 15 - Location of Screw on Flange Clamp PUMP (Procedure if pump is binding) 1. Remove upper shell (See Figure 8, page 7). 2. Loosen hex screw on flange clamp at rear of motor with 5/1 ...

  • Dayton 3E359B - page 9

    Dayton Operating Instructions and Parts Manual 9 ® Models 3E358B and 3E359B Maintenance (Continued) Fuel Pump/ Filter 8. Inspect nozzle for damage. If damaged or clogged, replace nozzle. 9. Make sure plug is in place on burner head. 10. Replace nozzle into burner head and tighten firmly (175-200 inch- pounds). 11. Attach burner head to combustion ...

  • Dayton 3E359B - page 10

    Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B PUMP PRESSURE ADJUSTMENT FOR HEA TERS WITH FUEL FIL TER INTER- NAL TO PUMP 1. Remove pressure gauge plug from fuel pump port marked “GAUGE.” 2. Install accessory pressure gauge (part number 110380-01) to fuel pump port marked “GAUGE” (S ...

  • Dayton 3E359B - page 11

    Dayton Operating Instructions and Parts Manual 11 ® Models 3E358B and 3E359B Flush every 150-200 hours of operation or as needed Check for trash when filling fuel tank. Clean when dirty Clean twice a heating season or replace as needed Check and tighten loose connections occasionally Clean fuel filter element every 250 hours Clean and regap every ...

  • Dayton 3E359B - page 12

    Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Wiring Diagram 1 3 2 FAN SWITCH 75 BA MOTOR RELAY WHITE RED ORANGE ORANGE RED BLACK WHITE BLACK WHITE BLUE BLUE WHITE BLACK BLACK THERMOSTAT B R FLAME-OUT CONTROL RESET BUTTON RED YELLOW YELLOW RED WHITE SOLENOID VALVE WHITE TERMINAL BOARD TERM ...

  • Dayton 3E359B - page 13

    Dayton Operating Instructions and Parts Manual 13 ® Models 3E358B and 3E359B T roubleshooting Chart Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur . Possible Cause(s) Corrective Action Symptom Motor does not start when heater is plugged in and thermostat setting is higher than surroundin ...

  • Dayton 3E359B - page 14

    Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B T roubleshooting Chart (Continued) Possible Cause(s) Corrective Action Symptom Heater will not ignite, but motor runs for a short period of time (Continued) 1. Adjust pump pressure (See Pump Pressure Adjustment section, page 10) 2. Clean fuel f ...

  • Dayton 3E359B - page 15

    Dayton Operating Instructions and Parts Manual 15 ® Models 3E358B and 3E359B T roubleshooting Chart (Continued) Possible Cause(s) Corrective Action Symptom Heater ignites, but flameout control shuts off heater after a short period of time (Continued) 4. Clean photocell lens with clean, cotton swab 5. Replace photocell 6. Replace flameout control 7 ...

  • Dayton 3E359B - page 16

    Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B For Repair Parts, call 1-800-323-0620 24 hours a day – 365 days a year 8 11 9 (10 inside) 7 14 16 19 18 17 (3) 13 12 15 21 22 (2) 6 2 3 5 4 1 20 Figure 23 - Repair Parts Illustration for Motor And Pump Assembly for Heaters with Fuel Filter In ...

  • Dayton 3E359B - page 17

    Dayton Operating Instructions and Parts Manual 17 ® Models 3E358B and 3E359B Repair Parts List Reference Number Description Part Number Qty . 1 Wiring cover 097492-03 1 2 5/16-24 x 5/16" Screw *HF5-5C 4 3 5/16" External lockwasher *WLE-5 4 4 #10-16 x 3/8" Screw *M11084-26 3 5 Motor (Model 3E358B) 099562-01 1 Motor (Model 3E359B) 099 ...

  • Dayton 3E359B - page 18

    Dayton Operating Instructions and Parts Manual 18 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B For Repair Parts, call 1-800-323-0620 24 hours a day – 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger P ...

  • Dayton 3E359B - page 19

    Dayton Operating Instructions and Parts Manual 19 ® Models 3E358B and 3E359B Repair Parts List 3E358B and 3E359B Reference Number Description Part Number Qty . Burner Head Assembly - Figure 25 1 #6-32 x 3/8" Screw (Model 3E358B only) *M10908-2 2 2 Photocell bracket (Model 3E358B only) 099229-01 1 3 Spark plug HA3012 1 4 Nozzle (Model 3E358B) ...

  • Dayton 3E359B - page 20

    Dayton Operating Instructions and Parts Manual 20 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B For Repair Parts, call 1-800-323-0620 24 hours a day – 365 days a year 3E358B Figure 27 - Repair Parts Illustration for Model 3E358B 1 2 2 4 5 21 2 7 8 9 10 13 11 12 14 15 16 19 20 21 4 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 37 38 34 ...

  • Dayton 3E359B - page 21

    Dayton Operating Instructions and Parts Manual 21 ® Models 3E358B and 3E359B 3E358B Repair Parts List Reference Number Description Part Number Quantity 1 Upper shell 108436-03 1 2 #10-16 x 1/2" Screw *M11084-27 15 3 Combustion chamber and shield M50542-01 1 4 Bushing M30865-02 7 5 Air deflector M50086 5 6 Burner head assembly † 1 7 Photocel ...

  • Dayton 3E359B - page 22

    Dayton Operating Instructions and Parts Manual 22 Dayton Portable Oil-Fir ed Heaters ® 3E358B and 3E359B Figure 28 - Repair Parts Illustration for Model 3E359B 1 2 2 3 4 5 13 6 7 45 46 8 9 10 11 13 14 21 18 17 15 16 23 22 24 25 33 2 4 28 30 26 27 34 25 16 2 35 36 41 42 15 43 43 44 39 38 37 15 29 12 40 2 19 20 2 4 31 32 47 For Repair Parts, call 1- ...

  • Dayton 3E359B - page 23

    Dayton Operating Instructions and Parts Manual 23 ® Models 3E358B and 3E359B 3E359B Repair Parts List (*) Standard hardware item, available locally . (†) Not available as complete assembly . ( ) Not shown. Reference Number Description Part Number Quantity 1 Upper shell 108396-03 1 2 #10-16 x 1/2" Screw *M11084-27 28 3 Combustion chamber and ...

  • Dayton 3E359B - page 24

    Dayton Operating Instructions and Parts Manual 3E358B and 3E359B Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A. 101422-01 Rev . G 07/02 ® LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Dayton ® Portable Oil-Fired heaters, Models covered in this manual, are warranted by Dayton Electric Mfg. Co. (Dayton) to the original ...

Manufacturer Dayton Category Electric Heater

Documents that we receive from a manufacturer of a Dayton 3E359B can be divided into several groups. They are, among others:
- Dayton technical drawings
- 3E359B manuals
- Dayton product data sheets
- information booklets
- or energy labels Dayton 3E359B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Dayton 3E359B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Dayton 3E359B, service manual, brief instructions and user manuals Dayton 3E359B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Dayton 3E359B.

Similar manuals

A complete manual for the device Dayton 3E359B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Dayton 3E359B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Dayton 3E359B.

A complete Dayton manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Dayton 3E359B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Dayton 3E359B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Dayton 3E359B, that we can find in the current document
3. Tips how to use the basic functions of the device Dayton 3E359B - which should help us in our first steps of using Dayton 3E359B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Dayton 3E359B