    FPDM1000 SERIES Positive Displacement Mechanical Flowmeters ...

  • Omega FPDM1000 - page 2

    ...

  • Omega FPDM1000 - page 3

    Please read this information carefully befor e use! Before use, confirm the fluid to be used is compatible with the meter or consult with OMEGA for advice. To prevent damage fr om dirt or foreign matter , OMEGA recommends a Y or bas- ket type 60 mesh strainer be installed as close as possible to the inlet side of the meter . (If requir ed, contact ...

  • Omega FPDM1000 - page 4

    1. OMEGA recommends that when set- ting up pipework for meter installations, a bypass line be included in the de- sign. This provides the facility for a meter to be removed for maintenance without interrupting production. (See Figure 1) 2 NOTE: Incorrect installation can cause pr e- mature wear of meter components 7. Do not overtighten meter connec ...

  • Omega FPDM1000 - page 5

    3 OPERA TION SERVICE INSTRUCTIONS When fluid passes through the meter , the ro tors tur n. The gear located on top of one of the rotors drives the mechanical r egis- ters gear train which provides an accurate r eadout. Figure 3 Rotor #2 Rotor #1 Rotors must be at 90 ° to each other Disassembly: Ensure that the fluid supply to the meter is disconne ...

  • Omega FPDM1000 - page 6

    4 Check rotor operation by turning either of the rotors. If the r otors are not in mesh correctly or do not move fr eely , remove one of the rotors and r eplace it correctly at 90 degrees to the other r otor . Recheck the operation of the rotors. 4. Inspect the gears in the meter cap for wear . Replace if requir ed - refer to spar e parts on page 6 ...

  • Omega FPDM1000 - page 7

    5 Symptom Probable Cause Corrective Action FLUID WILL NOT 1. Foreign matter blocking Dismantle meter , clean rotors. Strainer must FLOW THROUGH rotors be fitted in-line. THE METER 2. Line strainer blocked Clean strainer . 3. Damaged rotors Replace rotors. Strainer must be fitted in-line. 4. Meter connections over - Re-adjust connections. tightened ...

  • Omega FPDM1000 - page 8

    6 4 3 2 1 20 * 21 * 7 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 6 METER P ARTS LISTING Model: FPDM1004 Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS298N Meter Body 1/2 in. NPT (Aluminum) 11 MS337N Meter Body 1/2 in. NPT (Stainless Steel) 21 u BS145TES O-Ring (T eflon ® ) 21 u BS145VS O-Ring ( ...

  • Omega FPDM1000 - page 9

    7 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 1 to 30 / 0.26 to 8 Below 5 centipoise 3 to 25 / 0.8 to 6.6 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.5 Bar Operating T emperature Range -10 ° C to 80 ° C (+14 ° F to +176 ° F) * Unless hi ...

  • Omega FPDM1000 - page 10

    8 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS188N Meter Body 1 in. NPT (Aluminum) 11 MS186N Meter Body 1 in. NPT (Stainless Steel) 11 MS188F Meter Body 1 in. ANSI 150 lb. Flange (Aluminum) 11 MS186F Meter Body 1 in. ANSI 150 lb. Flange (S/Steel) 21 u BS235TES O-Ring (T eflon ® ) ...

  • Omega FPDM1000 - page 11

    9 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 6 to 120 / 1.6 to 32 Below 5 centipoise 10 to 100 / 2.6 to 26 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e 3450 kPa / 500 PSI / 34.5 Bar or Flange Rule Maximum Operating T emperature 80 ° C / 176 ° F (Stainless Steel ...

  • Omega FPDM1000 - page 12

    10 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS192N Meter Body 1 1 / 2 in. NPT (Aluminum) 11 MS190N Meter Body 1 1 / 2 in. NPT (Stainless Steel) 11 MS192F Meter Body 1 1 / 2 in. ANSI 150 lb. Flange (Aluminum) 11 MS190F Meter Body 1 1 / 2 in. ANSI 150 lb. Flange (S/Steel) 21 u BS243 ...

  • Omega FPDM1000 - page 13

    11 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 10 to 250 / 2.6 to 66 Below 5 centipoise 15 to 235 / 4 to 62 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e ** 1800 kPa / 260 PSI / 18 Bar or Flange Rule Maximum Operating T emperature -10 ° C to +80 ° C (+14 ° F to + ...

  • Omega FPDM1000 - page 14

    6 2 10 11 13 12 14 15 16 17 8 / 9 8A / 9A O-Ring Only 5 4 3 1 1 10 20 * * 7 5 12 METER P ARTS LISTING Item Rec. Part or Set No. Qty . Parts (Order fr om this column only) Part Description 11 MS520N Meter Body 2 in. NPT (Aluminum) 11 MS520-1N Meter Body 2 in. NPT (Stainless Steel) 11 MS483F Meter Body 2 in. ANSI 150 lb. Flange (Aluminum) 11 MS481F M ...

  • Omega FPDM1000 - page 15

    13 SPECIFICA TIONS Mechanical Meter Models Flow Ranges (LPM or GPM) Above 5 centipoise 15 to 350 / 3.96 to 92.46 Below 5 centipoise 30 to 300 / 7.93 to 79.25 Accuracy of Reading ± 1% Maximum Viscosity * 1000 Centipoise Maximum Operating Pressur e ** 1800 kPa / 260 PSI / 18 Bar Operating T emperature Range -10 ° C to +80 ° C (+14 ° F to +176 ° ...

  • Omega FPDM1000 - page 16

    ...

  • Omega FPDM1000 - page 17

    ...

  • Omega FPDM1000 - page 18

    ...

  • Omega FPDM1000 - page 19

    ...

  • Omega FPDM1000 - page 20

    M- 4103/ 04 05 ...

Manufacturer Omega Category Automobile Parts

Documents that we receive from a manufacturer of a Omega FPDM1000 can be divided into several groups. They are, among others:
- Omega technical drawings
- FPDM1000 manuals
- Omega product data sheets
- information booklets
- or energy labels Omega FPDM1000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega FPDM1000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega FPDM1000, service manual, brief instructions and user manuals Omega FPDM1000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega FPDM1000.

Similar manuals

A complete manual for the device Omega FPDM1000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega FPDM1000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega FPDM1000.

A complete Omega manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega FPDM1000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega FPDM1000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega FPDM1000, that we can find in the current document
3. Tips how to use the basic functions of the device Omega FPDM1000 - which should help us in our first steps of using Omega FPDM1000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega FPDM1000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega FPDM1000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega FPDM1000?

Use the form below

If you did not solve your problem by using a manual Omega FPDM1000, ask a question using the form below. If a user had a similar problem with Omega FPDM1000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)