Manual Lincoln Electric 4R90

8 pages 0.83 mb
Download

Go to site of 8

Summary
  • Lincoln Electric 4R90 - page 1

    Power W ave ® i400 R obotic Welding Power Wave ® i400 Power Source & A utoDrive™ 4R90 W ire Feeder Th e Pow er Wa ve ® i400 & AutoDrive™ 4R90 solution delivers Lincoln’ s best performance technologies and welding processes all rolled into one highly efficient inverter power source paired with a compact, durable wire feeder designed ...

  • Lincoln Electric 4R90 - page 2

    [2] Publication E10.1 1 www .lincolnelectric.com A CLOSER LOOK A DV ANT AGE LINCOLN • Flexible Design - Designed for simple, seamless integration with the F ANUC ® Robotics R-30iA Controller , or use as a separated configuration to meet your weld cell requirements. • Quality and Consistent Welding Results - Lincoln’ s Waveform Control T echn ...

  • Lincoln Electric 4R90 - page 3

    [3] Publication E10.1 1 www .lincolnelectric.com A CLOSER LOOK A new unique robotic wir e feeder package focused on .035-.045 wire applications. High performance wire drive system featuring: • Compact package • Lightweight • T ool-less design • Durable and rugged ADV ANT AGE LINCOLN • Integrated Design - Designed to “nest” in the uppe ...

  • Lincoln Electric 4R90 - page 4

    [4] Publication E10.1 1 www .lincolnelectric.com LINCOLN NEXTWELD ® INNOV A TIONS FOR CHALLENGING APPLICA TIONS Waveform Control T echnology ® makes it possible to take advanta ge of Lincoln Nextweld ® innovations like these pa tented processes using the Power Wave ® i400 and the AutoDrive ™ 4R90 wire feeder: W AVEFORM CONTROL TECHNOLOGY ® D ...

  • Lincoln Electric 4R90 - page 5

    HIGH SPEED DIGIT AL CONTROL TECHNOLOGY & FEA TURES: Lincoln Electric emerges as an industry leader with a distributed control architecture desi gn in t he Po wer Wave ® i 400 sys tem crea ted wi th a flexi ble desi gn tha t ensure s future expansion capabilities and features. The state-of-the-art technology used in this system is designed with ...

  • Lincoln Electric 4R90 - page 6

    [6] Publication E10.1 1 www .lincolnelectric.com A CLOSER LOOK SYSTEM DIAGRAMS Easy connection and installation provides for a stress-fr ee commissioning stage. The ease of use and servicing ensur es users are ef ficient and productive with their time. New F ANUC ® Robotics/Lincoln Electric solution providing the latest technology and features tog ...

  • Lincoln Electric 4R90 - page 7

    [7] Publication E10.1 1 www .lincolnelectric.com A CLOSER LOOK SYSTEM DIAGRAMS Backward compatibility is supported to ensure existing r obotic cells can be integrated with Power W ave ® i400 (shown here is a Power W ave ® F355i replacement). Flexible solution for integrated or separated installations. The system accommodates to your needs. Dual A ...

  • Lincoln Electric 4R90 - page 8

    POWER WA VE ® i400 Input Power 200/230/380-415/460/575 3 Phase Input 50/60 Hz * Single pr oduct number - CE compliance is pro v ided with a CE Filt er Kit. Input voltage is limit ed to 380-415/3/50/60 with kit instal led. Duty Cycle 350A/34V/100% 400A/36V/60% 420A/37V/40% * No derating for CV versus Pulse modes. Output Current Range 5-420 ADC * Be ...

Manufacturer Lincoln Electric Category Welder

Documents that we receive from a manufacturer of a Lincoln Electric 4R90 can be divided into several groups. They are, among others:
- Lincoln Electric technical drawings
- 4R90 manuals
- Lincoln Electric product data sheets
- information booklets
- or energy labels Lincoln Electric 4R90
All of them are important, but the most important information from the point of view of use of the device are in the user manual Lincoln Electric 4R90.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Lincoln Electric 4R90, service manual, brief instructions and user manuals Lincoln Electric 4R90. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Lincoln Electric 4R90.

A complete manual for the device Lincoln Electric 4R90, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Lincoln Electric 4R90 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Lincoln Electric 4R90.

A complete Lincoln Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Lincoln Electric 4R90 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Lincoln Electric 4R90, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Lincoln Electric 4R90, that we can find in the current document
3. Tips how to use the basic functions of the device Lincoln Electric 4R90 - which should help us in our first steps of using Lincoln Electric 4R90
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Lincoln Electric 4R90
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Lincoln Electric 4R90 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Lincoln Electric 4R90?

Use the form below

If you did not solve your problem by using a manual Lincoln Electric 4R90, ask a question using the form below. If a user had a similar problem with Lincoln Electric 4R90 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)