    MAGNESIUM 4-1/2” ANGLE GRINDER 98107 SET UP AND OPERA TING INSTRUCTIONS Distributed exclusively by Harbor Freight T ools ® . 3491 Mission Oaks Blvd., Camarillo, CA 9301 1 Visit our website at: http://www .harborfreight.com Read this material before using this product. Failure to do so can result in serious injury . SA VE THIS MANUAL. Copyright ? ...

  • Chicago Electric 98107 - page 2

    Page 2 For technical questions, please call 1-800-444-3353. SKU 98107 CONTENTS IMPORT ANT SAFETY INFORMA TION ............................ 3 GENERAL POWER T OOL SAFETY W ARNINGS....................... 3 GRINDING, SANDING OR WIRE BRUSHING OPERA TION SAFETY W ARNINGS....................... 5 KICKBACK AND RELA TED W ARNINGS ........................... ...

  • Chicago Electric 98107 - page 3

    Page 3 For technical questions, please call 1-800-444-3353. SKU 98107 SA VE THIS MANUAL Keep this manual for the safety warn- ings and precautions, assembly , operat- ing, inspection, maintenance and cleaning procedures. Write the product’ s serial number in the back of the manual near the assembly diagram (or month and year of purchase if produc ...

  • Chicago Electric 98107 - page 4

    Page 4 For technical questions, please call 1-800-444-3353. SKU 98107 plugs with grounded power tools. Unmodied plugs and matching out - lets will reduce risk of electric shock. A void body contact with grounded b. surfaces such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is grounded. ...

  • Chicago Electric 98107 - page 5

    Page 5 For technical questions, please call 1-800-444-3353. SKU 98107 proved for the specic hazards in the work area. Power tool use and care 4. Do not force the power tool. Use a. the correct power tool for your ap- plication. The correct power tool will do the job better and safer at the rate for which it was designed. Do not use the power too ...

  • Chicago Electric 98107 - page 6

    Page 6 For technical questions, please call 1-800-444-3353. SKU 98107 mum speed marked on the power tool. Accessories running faster than their RA TED SPEED can break and  The outside diameter and the 5. thickness of your accessory must be within the capacity rating of your power tool. Incorrectly sized accessories can ...

  • Chicago Electric 98107 - page 7

    Page 7 For technical questions, please call 1-800-444-3353. SKU 98107 could snag your clothing, pulling the accessory into your body . Regularly clean the power tool’ s 14. air vents. The motor ’s fan will draw the dust inside the housing and ex - cessive accumulation of powdered metal may cause electrical hazards. Do not operate the power tool ...

  • Chicago Electric 98107 - page 8

    Page 8 For technical questions, please call 1-800-444-3353. SKU 98107 manual cannot cover all possible con- ditions and situations that may occur . It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator . Kickback and Related W arnings Kickback is ...

  • Chicago Electric 98107 - page 9

    Page 9 For technical questions, please call 1-800-444-3353. SKU 98107 side of cut-off wheel. Abrasive cut- off wheels are intended for peripheral grinding, side forces applied to these wheels may cause them to shatter . Always use undamaged wheel 4. anges that are of correct size and shape for your selected wheel. Proper wheel anges support t ...

  • Chicago Electric 98107 - page 10

    Page 10 For technical questions, please call 1-800-444-3353. SKU 98107 Grip tool as lightly as possible (while 6.  the tool do the work. T o reduce vibration, maintain the tool 7. as explained in this manual. If any abnormal vibra ...

  • Chicago Electric 98107 - page 11

    Page 1 1 For technical questions, please call 1-800-444-3353. SKU 98107 ample, a 14 gauge cord can carry a higher current than a 16 gauge cord. (See T able A.) When using more than one exten- 3. sion cord to make up the total length, make sure each cord contains at least the minimum wire size required. (See T able A.) If you are using one extension ...

  • Chicago Electric 98107 - page 12

    Page 12 For technical questions, please call 1-800-444-3353. SKU 98107 SPECIFICA TIONS Electrical Requirements    10,500 RPM Wheel Diameter  Arbor Diameter  Spindle Th ...

  • Chicago Electric 98107 - page 13

    Page 13 For technical questions, please call 1-800-444-3353. SKU 98107 Installing the Auxiliary Handle TO PREVENT SERIOUS INJUR Y : Do not operate this tool with one hand only or without the Auxiliary Handle properly installed. The Auxiliary Handle (27) may be 7. installed in one of three positions, on either side or on top of the Gear Housing (28) ...

  • Chicago Electric 98107 - page 14

    Page 14 For technical questions, please call 1-800-444-3353. SKU 98107 Closely inspect the Grinding Wheel 4. before mounting. Perform a ring-test on the wheel (unless wheel is smaller than 4” or is an unusual shape) as follows:  a. through the ...

  • Chicago Electric 98107 - page 15

    Page 15 For technical questions, please call 1-800-444-3353. SKU 98107 W ork Piece and Work Area Set Up Designate a work area that is clean 1. and well-lit. The work area must not allow access by children or pets to prevent injury and distraction. Route the power cord along a safe 2. route to reach the work area without creating a tripping hazard o ...

  • Chicago Electric 98107 - page 16

    Page 16 For technical questions, please call 1-800-444-3353. SKU 98107 MAINTENANCE AND SER VICING Procedures not specically explained in this manual must be performed only by a qualied technician. TO PREVENT SERIOUS INJUR Y FROM ACCIDENT AL OPERA TION: T urn the Power Switch of the tool to its “OFF” position and unplug the tool from its e ...

  • Chicago Electric 98107 - page 17

    Page 17 For technical questions, please call 1-800-444-3353. SKU 98107 T roubleshooting Problem Possible Causes Likely Solutions T ool will not start No power at outlet. 1. Cord not connected. 2. Carbon Brushes may be worn or 3. damaged. Check power at outlet. 1. Check that cord is plugged in. 2. Inspect Carbon Brushes and replace if 3. necessary . ...

  • Chicago Electric 98107 - page 18

    Page 18 For technical questions, please call 1-800-444-3353. SKU 98107 PLEASE READ THE FOLLOWING CAREFULL Y          ...

  • Chicago Electric 98107 - page 19

    Page 19 For technical questions, please call 1-800-444-3353. SKU 98107 ASSEMBL Y DIAGRAM Record Product’ s Serial Number Here: Note: If product has no serial number , record month and year of purchase instead. Note: Some parts are listed and shown for illustration purposes only , and are not avail- able individually as replacement parts. ...

  • Chicago Electric 98107 - page 20

    Page 20 For technical questions, please call 1-800-444-3353. SKU 98107 90 DA Y W ARRANTY Harbor Freight T ools Co. makes every ef fort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the d ...

Manufacturer Chicago Electric Category Grinder

Documents that we receive from a manufacturer of a Chicago Electric 98107 can be divided into several groups. They are, among others:
- Chicago Electric technical drawings
- 98107 manuals
- Chicago Electric product data sheets
- information booklets
- or energy labels Chicago Electric 98107
All of them are important, but the most important information from the point of view of use of the device are in the user manual Chicago Electric 98107.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Chicago Electric 98107, service manual, brief instructions and user manuals Chicago Electric 98107. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Chicago Electric 98107.

A complete manual for the device Chicago Electric 98107, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Chicago Electric 98107 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Chicago Electric 98107.

A complete Chicago Electric manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Chicago Electric 98107 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Chicago Electric 98107, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Chicago Electric 98107, that we can find in the current document
3. Tips how to use the basic functions of the device Chicago Electric 98107 - which should help us in our first steps of using Chicago Electric 98107
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Chicago Electric 98107
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Chicago Electric 98107 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Chicago Electric 98107?

Use the form below

If you did not solve your problem by using a manual Chicago Electric 98107, ask a question using the form below. If a user had a similar problem with Chicago Electric 98107 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)