    English Español P ortuguês Deutch Italiano Français INSTRUCTION MANUAL FOR DIGIT AL BLOOD PRESSURE MONIT OR MODEL CH-432B - Eng 1 - CH-432B SYSTOLIC mmHg DIASTOLIC mmHg PULSE /min P O W E R S T A R T ...

  • Citizen CH-432B - page 2

    After cleaning the cuff with a neutral detergent, lightly rinse it with water and let it dry in the air . Hard rubbing or wash- ing in a washing machine will cause air leakage. Also, be careful not to get water into the air hose. CLEANING METHOD OF CUFF GENERAL REMARKS General Remarks on blood pressure measurement • If the cuff is to be deflated ...

  • Citizen CH-432B - page 3

    English Español P ortuguês Deutch Italiano Français • Putting on the cuff is one of the most important tasks for ensuring proper measurement of blood pressure. Wind the cuff around the arm and tighten it so that one finger may be inserted between the cuff and arm. • Do NOT measure blood pressure after bathing or drink- ing. • When you feel ...

  • Citizen CH-432B - page 4

    • When the monitor is very dirty, wipe it clean with a cloth moistened with Sterilizing alcohol or a neutral detergent, and then wipe it with a dry cloth. Do NOT use thinner or benzene. Nature and frequency of maintenance: This products is designed for use over an extended period of time; however , it is generally recommended that it be inspected ...

  • Citizen CH-432B - page 5

    English Español P ortuguês Deutch Italiano Français - Eng 5 - IDENTIFICA TION OF P ARTS C H - 4 3 2 B S Y S T O L IC m m H g D IA S T O L IC m m H g P U L S E /m in POWER ST ART BT T ube socket Systolic blood pressure display section Diastolic blood pressure/ Pulse display section Cuff Cuff tube Air connector Power/Start switch Battry cover ...

  • Citizen CH-432B - page 6

    - Eng 6 - MEASUREMENTS 1. Attaching of Arm Cuff and P osture During Measurement Unfasten and open the cuff as shown in the figure. Wind the arm cuff around the left upper arm tightly so that bottom edge of the cuff is positioned about 1 – 2cm above the elbow joint. • When you will wind the cuff, please wind the cuff next to the skin of possible ...

  • Citizen CH-432B - page 7

    English Español P ortuguês Deutch Italiano Français - Eng 7 - Rest the elbow on a table so that the section of the upper arm is at the height of the heart. Relax the lower arm across the table and remain still, since movement - artifacts may falsify the measuring result. Make measurements in either a seated or reclining posture with the palm tur ...

  • Citizen CH-432B - page 8

    - Eng 8 - The pressure is automatically heightened to the level for measurement of the blood pressure based on the last-mea- sured systolic blood pressure. At the first measurement after battery replacement the pres- sure is heightened to 160mmHg. If the level of the pressure is not enough, the pressure is automatically heightened to the level for ...

  • Citizen CH-432B - page 9

    English Español P ortuguês Deutch Italiano Français - Eng 9 - SYSTOLIC mmHg DIASTOLIC mmHg PULSE /min SYSTOLIC mmHg DIASTOLIC mmHg PULSE /min When the measurement has been completed, the systolic blood pressure, the diastolic blood pressure and the pulse rate are alternately displayed and the air is discharged. The systolic blood pressure and th ...

  • Citizen CH-432B - page 10

    - Eng 10 - 3. T urn P ower OFF Press the “ POWER / ST ART ” switch to turn off. 4. Subsequent Measurement When a measurement is need again, 10 minutes, interval is necessary between measurements. 5. Automatic P ower OFF Function If the unit is left without any operation after measure- ment, an “ Automatic Power -OFF Function ” runs to turn ...

  • Citizen CH-432B - page 11

    English Español P ortuguês Deutch Italiano Français - Eng 11 - DESCRIPTION OF DISPLA Y MARKS DISPLA Y MARK CONDITION / CA USE CORRECTIVE ACTION Displayed when the blood pressure could not be measured accurately . (Some noises were detected by the movement of arm during measurement.) Displayed when the pulse rate could not be measured. Displayed ...

  • Citizen CH-432B - page 12

    - Eng 12 - SPECIFICA TIONS Model No. CH-432B Measuring Principle Oscillometric Method Measurement Localization Left Upper Arm Cuff Soft Cuff Arm Circumference Range 22.0 to 32.0cm Measurement Range Pressure 0 to 280 mmHg Pulse 40 to 180 Pulse/min. Accuracy Pressure ± 3 mmHg Pulse ± 5% of Reading Pressure Systolic blood pressure: 3 Digits Diastoli ...

  • Citizen CH-432B - page 13

    ● CITIZEN is a registered trademark of Citizen W atch Co., Japan. Consumer Electronics Division CBM Bldg. 5F , 5-68-10, Nakano, Nakano-ku, T okyo 164-0001, Japan Phone: (03)5345-7430 Fax: (03)5345-7431 E-mail: info-con@jcbm.co .jp ...

Manufacturer Citizen Category Blood Pressure Monitor

Documents that we receive from a manufacturer of a Citizen CH-432B can be divided into several groups. They are, among others:
- Citizen technical drawings
- CH-432B manuals
- Citizen product data sheets
- information booklets
- or energy labels Citizen CH-432B
All of them are important, but the most important information from the point of view of use of the device are in the user manual Citizen CH-432B.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Citizen CH-432B, service manual, brief instructions and user manuals Citizen CH-432B. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Citizen CH-432B.

Similar manuals

A complete manual for the device Citizen CH-432B, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Citizen CH-432B by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Citizen CH-432B.

A complete Citizen manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Citizen CH-432B - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Citizen CH-432B, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Citizen CH-432B, that we can find in the current document
3. Tips how to use the basic functions of the device Citizen CH-432B - which should help us in our first steps of using Citizen CH-432B
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Citizen CH-432B
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Citizen CH-432B in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Citizen CH-432B?

Use the form below

If you did not solve your problem by using a manual Citizen CH-432B, ask a question using the form below. If a user had a similar problem with Citizen CH-432B it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (1)

нургали

как можно проверить показания тонометра